BUCHI
Filter
Showing 1–30 of 61 results
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI Labortechnik AG |
| Type | Benchtop Spray Dryer |
| Model | B-290 |
| Sample Compatibility | Aqueous, Organic, and Mixed Solvent Systems |
| Maximum Feed Rate | 1.5 L/h (water), 2.0 L/h (organic solvents) |
| Inlet Air Temperature Range | 40–220 °C (optional up to 250 °C) |
| Particle Size Range | 1–100 µm (typical output 2–60 µm, adjustable via nozzle selection and process parameters) |
| Air Flow Rate | 35–40 m³/h |
| Atomizing Gas Flow | 200–1000 L/h at 5–8 bar |
| Drying Residence Time | 1.0–1.5 s |
| Nozzle Options | Standard ruby nozzle tip (0.7 mm), multi-fluid nozzles, ultrasonic nozzles, acid-resistant configuration available |
| Anti-static Coating | Patented internal glass surface treatment |
| Optional Upgrades | Solvent-compatible mode, spray freeze-drying module |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Model | B-290 |
| Max. Water Evaporation Rate | 1.0 L/h |
| Inlet Air Temperature Range | Up to 220 °C |
| Air Flow Rate | 35 m³/h |
| Compressed Air Flow (std.) | 800 L/h |
| Minimum Sample Volume | 20 mL |
| Nozzle Orifice | 0.7 mm (standard, ruby material) |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Laboratory Equipment |
| Models | B-290 (Spray Dryer), B-295 (Inert Gas Recycling Unit) |
| Sample Compatibility | Aqueous, organic solvents, and mixed-phase solutions |
| Max Feed Rate | 1.5 L/h |
| Inlet Air Temperature Range | Ambient to 220 °C |
| Particle Size Output | 1–60 µm |
| B-295 Cooling Capacity | 800 W at −10 °C |
| B-295 Minimum Outlet Temperature | −25 °C |
| B-295 Power Rating | 1.4 kW |
| Voltage | 200/230 V, 50–60 Hz |
| Dimensions (L×W×H) | 60 × 70 × 77 cm |
| Weight | 95 kg |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | B-390 |
| Pricing | Upon Request |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Laboratory Instrument |
| Model | B-395 |
| Pricing | Available Upon Request |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Probe-type (rotor-stator) homogenizer |
| Model | B-400 |
| Dimensions (W×D×H) | 300 × 510 × 530 mm |
| Sample Capacity | 10–150 g |
| Maximum Cycle Time | 30 s |
| Sterilization Compatibility | Autoclavable components (glass, PEEK, PP, titanium, PVDF membrane) |
| Operating Temperature Range of PVDF Membrane | –40 °C to +150 °C |
| Final Particle Size | ≤2 mm (down to 0.3 mm typical under optimized conditions) |
| Compliance | GS-mark certified (German Safety Standard) |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Laboratory Instrument |
| Model | B-585 |
| Temperature Range | 40–300 °C |
| Sample Capacity | Up to 250 mL |
| Rotational Speed | 0–50 rpm |
| Optional Accessories | Desiccant Chamber, Kugelrohr Upgrade Kit, Freeze-Drying & Sublimation Modules |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | E-500 SOX / E-500 SOX LSV |
| Extraction Chamber Volume | 65–120 mL |
| Receiving Flask Volume | 150–250 mL |
| Temperature Range | 30–200 °C |
| Temperature Control Accuracy | ±1% of setpoint |
| Number of Parallel Channels | 6 |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | E-800 / E-800 LSV |
| Extraction Chamber Volume | 130–220 mL |
| Receiving Flask Volume | 150–250 mL |
| Temperature Range | 30–400 °C |
| Temperature Control Accuracy | ±1% of setpoint |
| Number of Parallel Channels | 6 |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Solid-Liquid Extraction System |
| Model | E-914 |
| Temperature Range | 50–200 °C |
| Pressure Range | 50–150 bar |
| Extraction Cell Volumes | 40, 60, 80, 120 mL |
| Extraction Time per Batch | 20–40 min |
| Sample Capacity | 4 positions |
| Dimensions (W × D × H) | 670 × 725 × 500 mm |
| Nitrogen Supply | 5–10 bar |
| Solvent Mixer | 4-port |
| Pump Flow Rate | 50 mL/min |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Solid-Liquid Extraction System |
| Model | E-916 |
| Temperature Range | 50–200 °C |
| Pressure Range | 50–150 bar |
| Extraction Cell Volumes | 10, 20, 40, 60 mL |
| Extraction Time per Batch (6 samples) | 20–40 min |
| Sample Capacity | 6 positions |
| Dimensions (W × D × H) | 670 × 725 × 500 mm |
| Nitrogen Supply Requirement | 5–10 bar |
| Solvent Mixer | 4-port |
| Pump Flow Rate | 50 mL/min |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 to 25 °C |
| Cooling Capacity | 850 W |
| Temperature Stability | ±1 °C |
| Circulation Pump Pressure | 0.6 bar |
| Flow Rate | 2.5 L/min |
| Reservoir Volume | 3 L |
| Operation Mode | Continuous |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | F-125 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | −10 °C to +25 °C |
| Refrigeration Capacity | 2500 W at 15 °C |
| Temperature Stability | ±1 K |
| Circulation Pump Pressure | 0.6 bar |
| Circulation Flow Rate | 11 L/min |
| Reservoir Volume | 11 L |
| Operating Mode | Continuous Duty |
| Power Consumption (Max) | 2850 W |
| Voltage | 230 VAC ±10% / 115 VAC ±10% |
| Frequency | 50/60 Hz |
| Display | Digital, 0.1 K Resolution |
| Refrigerant | R134a |
| Overvoltage Category | II |
| Dimensions (W×H×D) | 990 × 540 × 650 mm |
| Weight | 100 kg |
| Hose Connector | 13.5 mm ID |
| Brand | BUCHI |
|---|---|
| Origin | Germany |
| Manufacturer | BUCHI AG |
| Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 °C to +25 °C |
| Refrigeration Capacity | 800 W |
| Temperature Stability | ±0.1 °C |
| Pump Pressure | 0.6 bar |
| Flow Rate | 2.5 L/min |
| Reservoir Volume | 3.0 L |
| Operating Mode | Continuous |
| Refrigerant | R134a |
| Power Supply | 230 V ±10%, 50/60 Hz |
| Max. Power Consumption | 850 W |
| Display Resolution | 0.1 °C |
| Control Accuracy | ±1.0 °C |
| Hose Connector | 8 mm |
| Dimensions (W×H×D) | 280 × 500 × 400 mm |
| Weight | 31 kg |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 to 25 °C |
| Cooling Capacity | 1100 W |
| Temperature Stability | ±1 °C |
| Circulation Pump Pressure | 0.6 bar |
| Circulation Flow Rate | 3 L/min |
| Reservoir Volume | 4.5 L |
| Operation Mode | Continuous |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –10 to 25 °C |
| Cooling Capacity | 1850 W |
| Temperature Stability | ±1 °C |
| Circulation Pump Pressure | 1 bar |
| Circulation Flow Rate | 11 L/min |
| Reservoir Volume | 6.5 L |
| Operation Mode | Continuous |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported |
| Model | H-506 |
| Extraction Chamber Volume | 84–216 mL |
| Receiver Flask Capacity | up to 500 mL |
| Temperature Range | 70–495 °C |
| Temperature Control Accuracy | ±3 °C |
| Number of Channels | 6 |
| Dimensions (W × D × H) | 312 × 614 × 470 mm |
| Net Weight | 13 kg |
| Power Consumption | 1200 W |
| Voltage | 220–240 VAC (±10 %) |
| Frequency | 50/60 Hz |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | I-300 Pro |
| Measurement Principle | Capacitive Absolute Pressure Sensing |
| Pressure Range | 1400–0 mbar (hPa) / 1050–0 Torr |
| Control Range | 1100–1 mbar (hPa) / 825–1 Torr |
| Pressure Accuracy | ±2 mbar |
| Vacuum Port | GL14 |
| Display | 7.0-inch TFT touchscreen |
| Power Supply | 30 VDC ±5% |
| Power Consumption | 10 W |
| Data Storage | 1 GB SD card (removable) |
| Enclosure Rating | IP21 |
| Certifications | CE, CSA |
| Dimensions (W×H×D) | 122 × 221 × 50 mm |
| Weight | 600 g |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Instrument |
| Model | I-300 |
| Measurement Principle | Capacitive Absolute Pressure Sensing |
| Pressure Range | 1400–0 mbar (hPa) / 1050–0 Torr |
| Control Range | 1100–1 mbar (hPa) / 825–1 Torr |
| Pressure Accuracy | ±2 mbar |
| Vacuum Port | GL14 |
| Display | 4.3-inch TFT touchscreen |
| Power Supply | 30 VDC ±5% |
| Power Consumption | 3 W |
| IP Rating | IP21 |
| Certifications | CE, CSA |
| Dimensions (W×H×D) | 121 × 141 × 50 mm |
| Weight | 400 g |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | K-365 Dist Line |
| Instrument Type | Automated Steam Distillation System for Alcohol, pH, and Volatile Analyte Recovery |
| Application | Laboratory-Based Food & Beverage Quality Control |
| Distillation Time | 3.5 min/sample |
| Alcohol Content Range | 0–100 % v/v |
| pH Measurement Range | 0–14 |
| Dimensions (L×W×H) | 320 × 400 × 730 mm |
| Weight | 23 kg |
| Power Supply | 220–240 VAC ±10%, 50/60 Hz |
| Power Consumption | 2100 W |
| Recovery Rate | ≥99.5 % |
| Repeatability | RSD <0.8 % |
| Nitrogen Detection Range | 0.02–220 mg N |
| Compliance | CE, CSA |
| Cooling Water Management | Smart Flow-Controlled Condenser with Auto-Shutoff |
| Steam Power Control | 10–100 % adjustable, programmable steam ramping |
| Safety Features | Dual-interlocked transparent safety shield, real-time cooling water flow sensor, steam generator pressure monitoring, sample tube position verification, reagent/waste/water level sensing |
| Voltage Regulation | Integrated voltage stabilizer for consistent steam output under fluctuating mains conditions |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2100 W |
| Dimensions (L×W×H) | 320 × 400 × 730 mm |
| Weight | 23 kg |
| Electrical Supply | 220–240 VAC ±10%, 50/60 Hz |
| Safety Certifications | CE, CSA |
| Repeatability | RSD <0.8% |
| Nitrogen Detection Range | 0.02–220 mg N |
| Cooling Water Management | Intelligent Flow Control with Auto-Shutoff |
| Steam Power Control | Adjustable 10–100%, Programmable Steam Gradient |
| Safety Systems | Dual-flow cooling water sensor, steam generator pressure monitoring, sample tube presence detection, transparent safety shield with interlock, reagent/waste/water level sensing |
| Voltage Stabilization | Integrated line regulator for consistent steam output |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Automated Kjeldahl Nitrogen Determinator |
| Model | K-375 |
| Nitrogen Range | 0.02–200 mg N |
| Distillation Time | 1–9999 min (typical: 4 min/sample) |
| Repeatability | RSD ≤ 1% |
| Sample Weight Capacity | ≤ 5 g (solid), ≤ 200 mL (liquid) |
| Nitrogen Recovery Rate | ≥ 99.5% |
| Max Power Consumption | 2.4 kW |
| Dimensions (L×W×H) | 458 × 670 × 431 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Automated Sample Handler (KjelSampler) |
| Model | K-376 / K-377 |
| Instrument Category | Kjeldahl Nitrogen Analyzer Accessory |
| Nitrogen Determination Range | 0.02 – 200 mg N |
| Distillation Time per Sample | ≤240 s |
| Repeatability | RSD < 1 % |
| Sample Weight Capacity | Solids ≤ 5 g, Liquids ≤ 200 mL |
| Nitrogen Recovery Rate | >99.5 % (for 1–200 mg N) |
| Power Consumption | 150 W |
| Dimensions (L×W×H) | 505 × 750 × 655 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported |
| Model | K-415 |
| Pricing | Available Upon Request |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Imported Laboratory Instrument |
| Model | K-425 |
| Voltage | 220–240 VAC |
| Frequency | 50/60 Hz |
| Power | 1280 W |
| Weight | 12 kg |
| Dimensions (W × H × D) | 310 × 540 × 620 mm |
| Temperature Range | 70–580 °C |
| Temperature Accuracy | ±5 °C at 200 °C, ±10 °C at 550 °C |
| Max. Sample Capacity | 6 × 300 mL or 5 × 500 mL digestion tubes |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported |
| Model | K-436 |
| Power | 2550 W |
| Voltage | 220–240 VAC |
| Frequency | 50/60 Hz |
| Temperature Range | 70–580 °C |
| Temperature Accuracy | ±5 °C at 200 °C, ±10 °C at 550 °C |
| Sample Capacity | 12 × 300 mL or 10 × 500 mL digestion tubes |
| Dimensions (W × H × D) | 310 × 540 × 620 mm |
| Weight | 15.5 kg |
| Heating Principle | Infrared Radiant Heating |
| Exhaust Management | Integrated suction module with optional cold trap and H₂O₂-enhanced configuration |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported |
| Model | K-439 |
| Voltage | 220–240 VAC |
| Frequency | 50/60 Hz |
| Power | 2000 W |
| Weight | 15.5 kg |
| Dimensions (W × H × D) | 310 × 540 × 620 mm |
| Temperature Range | 70–580 °C |
| Temperature Accuracy | ±5 °C at 200 °C, ±10 °C at 550 °C |
| Max. Sample Capacity | 12 × 300 mL or 10 × 500 mL digestion tubes |
| Control Interface | Graphical LCD display with programmable method storage (50 user + 20 preloaded methods) |
| Compliance | Designed for IQ/OQ qualification per GLP/GMP guidelines |
| Exhaust Integration | Direct control interface for BUCHI SCRUBBER tail-gas absorption units |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Electric Heating Digestion Instrument |
| Automation Level | Semi-Automatic |
| Sample Capacity | 20 positions |
| Max. Heating Temperature | 420 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Block Material | Aluminum Alloy |
| Reagent Channels | 20 |
| Compliance | AOAC, ISO 8585, EN 13654-1 |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Max. Power Consumption | 2300 W |
| Weight | 18.5 kg |
| Dimensions (W×H×D) | 435 × 524 × 764 mm |
| Temperature Range | 30–450 °C |
| Temp. Uniformity | ≤±7 °C at 420 °C |
| Sample Tube Size | 300 mL |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Type | Imported Instrument |
| Model | K-446 / K-449 |
| Power | 2300 W |
| Heating Positions | 20 |
| Temperature Range | 30–450 °C |
| Temperature Accuracy | ±1 °C |
| Display | LCD |
| Automation Level | Semi-Automatic (K-446) / Fully Automatic (K-449) |
| Acid Vapor Containment | Integrated Sealed Block Design |
| Sample Tube Material | High-Purity Borosilicate Glass (BUCHI Certified) |
| Safety Features | Dual Temperature Limiting per Stage |
| User Interface | Programmable Multi-Stage Temperature Profiles with Countdown Timer and Real-Time Temperature Feedback |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Electric Heating Digestion Instrument |
| Automation Level | Fully Automatic |
| Sample Capacity | 20 positions |
| Max. Heating Temperature | 420 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Block Material | Aluminum Alloy Block |
| Reagent Channels | 20 |
| Compliance | AOAC, ISO 8585, EN 13656, ISO 14891 |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Max. Power Consumption | 2300 W |
| Dimensions (W × H × D) | 435 × 558 × 764 mm |
| Net Weight | 25.8 kg |
| Temperature Range | 30–450 °C |
| Temp. Uniformity | ≤±7 °C at 420 °C |
| Sample Tube Format | 300 mL digestion tubes |