C. Gerhardt
Filter
Showing all 21 results
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | CSB 8s |
| Digestion Method | Reflux Digestion |
| Heating Module | Single Aluminum Block |
| Batch Capacity | 8 samples |
| Temperature Range | 0–430 °C |
| Temperature Accuracy | ±0.5 °C |
| Digestion Vessel Volume | 300 mL |
| Timer Resolution | 0.0001 h (0.36 s) |
| Programmable Methods | 99 user-defined methods (up to 40 heating steps per method) |
| Preloaded Methods | 30 standard protocols |
| Power Control | Continuously adjustable heating power |
| Controller | Detachable, password-protected unit with audit trail and user access levels |
| Footprint | 51.5 × 48.3 cm |
| Safety Features | Motorized lift mechanism for sample rack, preheating function, thermal insulation, overtemperature protection |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | CSB-L 20s |
| Digestion Method | Reflux Digestion |
| Heating Module | Single Aluminum Block |
| Batch Capacity | 20 samples |
| Temperature Range | 0–430 °C |
| Temperature Accuracy | ±0.5 °C |
| Digestion Vessel Capacity | 300 mL |
| Timer Accuracy | ±0.00 min |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | FBS6 |
| Price Range | USD 2,700 – 6,800 (FOB Hamburg) |
| Heating Capacity | 1 position |
| Sample Throughput | 6 samples per run |
| Max Temperature | 425 °C |
| Power Supply | 230 V AC, 50–60 Hz |
| Power Consumption | 450 W |
| Dimensions (W×D×H) | 250 × 230 × 600 mm |
| Net Weight | 12 kg |
| Method Principle | Filter Bag-Based Acid-Base Digestion per AOAC 962.09 and ISO 6865 |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | FT12 |
| Price Range | USD 25,000 – 50,000 |
| Sample Capacity | 1–12 samples per batch |
| Heating System | Crystalline ceramic heater |
| Programmable Methods | 10 |
| Reagent Dispensing | Automated acid/alkali/water/waste handling |
| Filtration | Pneumatically controlled FibreBag® filtration |
| Safety Features | Closed-system operation, audible/visual error alerts |
| Cooling Water Requirement | 5 L/min (on-demand) |
| Power Supply | 230 V AC, 50 Hz |
| Power Consumption | 1900 W |
| Dimensions | 330 × 650 × 860 mm |
| Weight | 42 kg |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | KI 11/26 |
| Max Temperature | 650 °C |
| Number of Heating Positions | 6 |
| Flask Capacity | 500 mL (standard), 750 mL (expanded neck) |
| Voltage | 400 V, 3P+N |
| Frequency | 50–60 Hz |
| Power Consumption | 3480 W |
| Dimensions (L×W×H) | 900 × 250 × 300 mm |
| Net Weight | 15 kg |
| Exhaust Configuration | Centralized waste gas duct with minimized overflow |
| Digestion Time (Typical) | ~2 h |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | KT-L 20s |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 20 |
| Max. Heating Temperature | 430 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Electric Flat-Plate Heater |
| Reagent Channels | 20 |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Product Type | Imported |
| Model | KT-L 40s |
| Instrument Category | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 40 |
| Max. Heating Temperature | 430 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Aluminum Block with Drilled Wells |
| Reagent Channels | 8–40 |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | RF16/4 / RF16/6 |
| Max Temperature | 425 °C |
| Heating Positions | 4 / 6 |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power | 1800 W / 2700 W |
| Dimensions (W×D×H) | 600×225×340 mm / 900×225×340 mm |
| Weight | 12 kg / ~18 kg |
| Order Codes | 10-0017 / 10-0018 |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TTs SO2 |
| Product Type | Intelligent Automated System |
| Detection Limit | 0.1 mg/L (as SO₂) |
| Measurement Range | 0–100% (w/w or w/v, sample-dependent) |
| Distillation Positions | 4 |
| Distillation Flask Capacity | 800 mL |
| Max Heating Temperature | 650 °C |
| Programmable Methods | 99 |
| Magnetic Stirring | Integrated |
| Rated Power | 2000 W |
| Order No. | 12-0640 |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | TTs625 |
| Max Temperature | 650 °C |
| Heating Method | Direct infrared radiation onto digestion tubes |
| Rated Power | 2000 W |
| Voltage | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 636 × 354 × 740 mm |
| Weight | 21 kg |
| Digestion Tube Capacity | 6 × 250 mL (up to 800 mL with compatible racks) |
| Programmable Steps | Up to 40 segments per method, 99 methods storable |
| Tube Volume Range | 100–800 mL |
| Compliance | CE-marked, designed for GLP/GMP-aligned laboratories |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | VAP 550 |
| Detection Limit | 0.1234 mg/L |
| Measurement Range | 0.1234–500 mg/L |
| Instrument Class | Intelligent, Fully Automated Distillation-Titration System |
| Compliance | ISO 9001, ISO/IEC 17025, GLP, FDA 21 CFR Part 11 (via GERHARDT MasterControl Software) |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Range | 0.1–200 mg N |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% RSD |
| Sample Mass | 1 g |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Linear Range | 0.1–200 mg N |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Imported Instrument |
| Model | VAPODEST 550 |
| Distillation Time | 12 min |
| Compliance | ISO 9001, ISO/IEC 17025, GLP |
| Connectivity | LAN, LIMS, Barcode Scanners, Balances, Printers |
| Software | Gerhardt MasterLab Suite |
| Safety Features | Real-time Coolant Flow Monitoring, Reagent Level Sensors, Steam Generator Status, Sample Tube Position Detection |
| Optional | Liquid Level Sensors for 5 L / 10 L / 20 L Reagent Carboys |
| Maintenance | Maintenance-free Steam Generator, Chemically Resistant Components |
| Operation Mode | Simultaneous Distillation and Titration, Standby Mode with Instant Restart |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | VAPODEST 550C |
| Price | USD 92,000 (approx.) |
| Distillation Time | 12 min per sample |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Kjeldahl Nitrogen Determinator |
| Model | VAPODEST® 200 |
| Automation Level | Semi-Automatic |
| Nitrogen Range | 0.1–200 mg |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% |
| Sample Weight (solid) | ≤5 g |
| Recovery Rate | 99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 mm × 390 mm × 697 mm |
| Compatible Acid Titration Range | Universal (any standard acid concentration) |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | KI 12/24 / KI 9/16 |
| Max. Heating Temperature | 650 °C / 600 °C |
| Heating Block Capacity | 4 × 500–750 mL flasks / 6 × 50–250 mL flasks |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power | 2320 W / 1800 W |
| Dimensions (W×D×H) | 650 × 380 × 950 mm |
| Weight | 35 kg / 25 kg |
| Compliance | Designed for ASTM D1142, ISO 5983-1, AOAC 984.13, and USP <467> residual solvent workflows |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Product Type | Imported Manual Single-Channel Volumetric Pipettes |
| Models | 4201 (0.25–2.50 mL), 4202 (0.50–5.00 mL), 4203 (1.00–10.00 mL), 4204 (2.50–25.00 mL), 4205 (5.00–50.00 mL) |
| Max Capacity | 2.5 mL / 5 mL / 10 mL / 25 mL / 50 mL |
| Accuracy Tolerance | ±0.025 mL |
| Operation Mode | Manual |
| Channel Count | Single |
| Compliance | ISO 8655-2:2022 (Volumetric pipettes – Part 2: Piston-operated volumetric apparatus) |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | SMA 8s |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 8 |
| Max Heating Temperature | 240 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Heating Principle | Electrical Resistance Heating |
| Reagent Dispensing Channels | 0 (No reagent addition) |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 200 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg N |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤±1% RSD |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 300 |
| Water Consumption | ~3 L/min |
| Distillation Time | ~3 min 30 s (standard Kjeldahl method) |
| Power | 2200 W |
| Frequency | 50/60 Hz |
| Weight | 34 kg |
| Dimensions | 527 × 390 × 697 mm |
| Repeatability | ±1% |
| Detection Limit | 0.1 mg |
| Supply Voltage | 230 V AC |
| Nitrogen Recovery Rate | >99.5% |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | TUR/K |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power Consumption | 205 W |
| Weight | 19 kg |
| Dimensions (W × D × H) | 330 × 450 × 420 mm |
| Exhaust Gas Removal Efficiency | >90% |
| Maintenance Requirement | Minimal |