ELGA Veolia
Filter
Showing all 25 results
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Models | BIOPURE 7, 15, 60, 120, 200, 300, 600, 1000, 2500, 5000 (L/hr) |
| Water Grade | ASTM Type I / ISO 3696 Grade 1 / Pharmacopoeial Purified Water (PW) & Water for Injection (WFI)-compatible output |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb |
| Microbial Count | <0.25 EU/mL |
| Particulates (>0.1 µm) | <0.2 particles/mL |
| Conductivity (@25 °C) | <1 µS/cm (for BIOPURE 7–120), <5 µS/cm (for BIOPURE 200–600), <30 µS/cm (for BIOPURE 1000–5000) |
| Feed Water TDS Limit | ≤500 ppm |
| UV Wavelength | 254 nm (integrated low-pressure mercury lamp) |
| Sanitization | Fully automated, programmable hot-water or ozone-based online disinfection cycle |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | CENTRA R500-600 |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 1–18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | 10–20 ppb |
| Microbial Count / Endotoxin | <0.002 EU/mL |
| Particulates (>0.1 µm) | ≤0.2 particles/mL |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MEDICA |
| Water Grade | CLRW (Clinical Laboratory Reagent Water, per CLSI C37-A) |
| Resistivity | >10 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <1 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particulates (>0.1 µm) | <0.2 µm |
| Dissolved Oxygen (MEDICA-D only) | 6–8 ppm |
| Flow Rate | 7–15 L/hr |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MEDICA-Pro |
| Purified Water Grade | CLRW (Clinical Laboratory Reagent Water, per CLSI C3-A4) |
| Resistivity | >10 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <1 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <0.2 particles/mL |
| Flow Rate (to point-of-use network) | Up to 4 L/min |
| RO Output Capacity Options | 30 / 60 / 120 L/hr |
| Pre-treatment | Protek™ high-capacity adsorption cartridge |
| Polishing | Medpure™ long-life ion exchange cartridge |
| CO₂ Reduction | E-Column™ integrated on MEDICA Pro-RE variant |
| Microbial Control | Dual-stage UV (185/254 nm) + recirculating loop + automated sanitization cycle |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Chorus 1 Complete / Chorus 2+ |
| Pure Water Grade | Type I (Ultra-Pure) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count / Endotoxins | <0.001 EU/mL |
| Particulates (>0.1 µm) | ≤0.2 particles/mL |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | ELGA LabWater, Veolia |
| Product Type | Imported Laboratory Ultra-Pure Water System |
| Model | Chorus 1 Complete |
| Pure Water Grade | Type I (ASTM D1193-20, ISO 3696:1987 Class 1) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <1 CFU/100 mL |
| Endotoxins | <0.001 EU/mL |
| Particulates (>0.1 µm) | <0.2 particles/mL |
| Storage Tank Options | 15 L, 30 L, 60 L, or 100 L recirculating tanks with integrated CO₂ removal and sterile vent filters |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Ultra-Pure Water System |
| Model | PURELAB Classic |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | 1–3 ppb |
| Microbial Count | <0.1 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <0.2 particles/mL |
| Flow Rate | Up to 2 L/min |
| Purification Stages | DI + UV + UF (configurable) |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Model | Classic DI / UV / UF / UVF |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | 1–3 ppb (with RO pre-treatment) |
| Microbial Count | <1 CFU/mL |
| Endotoxin Level | <0.01 EU/mL |
| Particle Count (>0.1 µm) | <1 particle/mL (with ultrafiltration) |
| Flow Rate | Up to 2 L/min, continuously adjustable from dropwise to full flow |
| Control System | Microprocessor-based single-board controller with GLP-compliant data tracking |
| Sanitization | Integrated full-wet-path thermal or chemical sanitization protocol |
| Compliance | Meets ASTM D1193-23, ISO 3696:1987, CLSI EP21-A, and supports FDA 21 CFR Part 11 audit trail requirements for critical water systems |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Laboratory Water Purification System |
| Model | PURELAB Flex |
| Pure Water Grade | Type I (ASTM D1193-20, ISO 3696:1987 Class 1) |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particulates (>0.1 � | m): <1 particle/mL |
| RO Production Rate | up to 10 L/h |
| Dispense Flow Rate | 0.01–2 L/min |
| Integrated Touchscreen Display | Real-time resistivity, conductivity, TOC, temperature, and system status |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic |
| Model | PURELAB Micra |
| Pure Water Grade | Type II (ASTM D1193-20) |
| Resistivity | >2 MΩ·cm (typically >10 MΩ·cm at 25 °C) |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <50 ppb |
| Microbial/Endotoxin | Not Specified |
| Particulates (>0.1 µm) | RO-grade rejection ≥98% |
| Flow Rate | Up to 10 L/h |
| Feed Water Conductivity | <2000 µS/cm |
| Feed Temperature | 4–40 °C (optimal 15–25 °C) |
| Feed Pressure | 1–2 bar (15–30 psi) |
| Power Input | 100–240 VAC, 50–60 Hz |
| Noise Level | <40 dBA |
| Dimensions (W×D×H) | 505 × 230 × 335 mm |
| Weight (dry) | 15 kg |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Ultra-Pure Water System |
| Model | PURELAB Option-Q 7/15 |
| Output Flow Rate | 7 or 15 L/h |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | 1–3 ppb |
| Microbial Count | <1 CFU/mL (with optional Biofilter: <0.1 CFU/mL) |
| Endotoxin | <0.001 EU/mL |
| RNase | <0.002 ng/mL |
| DNase | <0.02 pg/μL |
| Particulates (>0.1 � | m): <0.2 particles/mL |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Laboratory Ultra-Pure Water System |
| Model | PURELAB Option-R |
| Pure Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | 10–15 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <20 ppb |
| Microbial Contamination | <1 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particulates (>0.1 µm) | <0.2 particles/mL |
| Flow Rate | 7–15 L/hr |
| Purification Technologies | Pre-treatment + Reverse Osmosis + Mixed-Bed Ion Exchange + UV Photo-oxidation (185/254 nm) + Optional 0.2 µm Final Filtration |
| Recirculation Loop | Integrated with Low-Adsorption Piping |
| Service Life Support | Genuine consumables and spare parts available until 2026 |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Laboratory Ultra-Pure Water System |
| Model | PURELAB Option-S |
| Pure Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | 5–15 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <20 ppb (typical range: 10–30 ppb) |
| Microbial Count | <0.1 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <0.2 particles/mL |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PURELAB Pharma Compliance |
| Pure Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Total Organic Carbon (TOC) | 1–3 ppb |
| Microbial Count | <0.001 CFU/mL |
| Endotoxin Level | <0.001 EU/mL |
| Particulates (>0.1 µm) | <0.01 particles/mL |
| Compliance | USP <643>, USP <645>, EP 2.2.44, ISO 13485, ISO 9001, GMP Annex 1, FDA 21 CFR Part 11 (audit trail enabled), GAMP 5, ISPE Good Practice Guides |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Category | Imported Laboratory Purification Equipment |
| Model | PURELAB Prima |
| Output Flow Rates | 7 / 15 / 30 L/hr |
| Resistivity | 0.2 MΩ·cm (Type III Water per ISO 3696 & ASTM D1193) |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | 20–50 ppb |
| Microbial Count | <5 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <0.2 particles/mL |
| RO Salt Rejection | ≥98% |
| Service Support | Genuine spare parts and consumables available until 2026 |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Ultra-Pure Water System |
| Model | PURELAB Pulse |
| Pure Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | 10–15 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <20 ppb |
| Microbial Count | <1 CFU/10 mL |
| Endotoxin | <0.001 EU/mL |
| Particles (>0.1 µm) | <0.2 particles/mL |
| Flow Rate | Pulse 1 — Max 10 L/hr |
| Technology | Integrated Recirculating Electrodeionization (EDI) with “Pulse Pure” Patented Control Architecture |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | PURELAB Quest |
| Purified Water Grade | ASTM Type I (Ultrapure), Type II (Pure), Type III (General Laboratory) |
| Resistivity | 18.2 MΩ·cm @ 25°C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <5 ppb |
| Microbial Count | <1 CFU/mL |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| RO Feed Rate | 10 L/h |
| Internal Reservoir | 7 L |
| External Reservoir Options | 15 L or 30 L |
| Dispense Flow Rate | Up to 1.2 L/min |
| Footprint | A4-sized (210 × 297 mm) |
| Wall-Mountable | Yes |
| Housing Material | >85% Recycled Polymer |
| Disinfection | Automated, Chemical-Free, <2 h Cycle |
| Data Interface | USB + AQUAVISTA Cloud Integration |
| Compliance | Meets ASTM D1193-20, ISO 3696:1987, CLSI EP21-A, USP <1231>, and supports GLP/GMP audit trails via AQUAVISTA |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Laboratory Ultra-Pure Water System |
| Model | PURELAB Ultra II |
| Purity Grade | ASTM Type I / ISO 3696 Grade 1 / CLSI EP28-A3c compliant |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | 1–10 ppb |
| Microbial Count | <0.1 CFU/mL (with optional 0.1 µm terminal filter) |
| Endotoxin | <0.001 EU/mL |
| Particulates (>0.1 µm) | <1 particle/mL |
| Flow Rate | Adjustable from dropwise to 2 L/min |
| Particle Filtration | 0.2 µm final filtration |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Model | PURELAB Ultra Genetic / Bioscience / Analytic / Ionic / Scientific |
| Purified Water Grade | Type I (ASTM D1193-20) |
| Resistivity | 18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | ≤0.1 ppm |
| Total Organic Carbon (TOC) | 1–3 ppb (Analytic), 1–2 ppb (Genetic), 3–10 ppb (Bioscience/Scientific/Ionic) |
| Microbial Count | <1 CFU/mL |
| Endotoxins | <0.001 EU/mL (Genetic & Bioscience only) |
| Particulates (>0.1 µm) | Removed via ultrafiltration |
| UV Wavelengths | 185 nm (photo-oxidation) and 254 nm (germicidal) |
| Flow Rate | Adjustable from dropwise to 2 L/min, programmable dispensing in 0.1 L increments |
| Data Logging | GLP-compliant column tracking, batch history, audit trail, PIN-secured operation |
| Compliance | Meets ISO 3696:1987, ASTM D1193-20, CLSI EP21-A, USP <1231>, and supports FDA 21 CFR Part 11 readiness |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Ultra-Pure Water System |
| Model | PURELAB Ultra |
| Purified Water Grade | ASTM Type I / ISO 3696 Grade 1 |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | 1–3 ppb (Genetic variant: real-time online TOC monitoring) |
| Microbial Count | <0.1 CFU/mL (with optional 0.2 µm terminal filter) |
| Endotoxins | <0.001 EU/mL |
| Particles (>0.1 µm) | <1 particle/mL |
| DNase | <0.02 pg/µL |
| RNase | <0.002 ng/mL |
| Flow Rate | Adjustable from single drop to 2 L/min |
| UV Lamps | Dual-wavelength (185 nm + 254 nm) |
| Brand | ELGA (Veolia) |
|---|---|
| Origin | Spain |
| Manufacturer | Veolia Water Technologies |
| Product Type | Imported Ultra-Pure Water System |
| Model | SIRION Advanced / Pro |
| Purified Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Particulate Removal (>0.1 µm) | ≥99% |
| Dissolved Inorganics Rejection | 97–98% |
| Dissolved Organics & Colloids Rejection | >99% |
| Feed Water TDS Tolerance | Up to 1000 mg/L (as NaCl) |
| Pre-filtration | Integrated 1 µm sediment filter |
| Control Interface | 7″ HMI touchscreen with real-time monitoring of pressure, flow rate, conductivity, and temperature |
| Compliance | EN 61000-6-2/-4, EN 61000-3-2/-3, CE-marked per EU Machinery Directive 2006/42/EC |
| CIP Compatibility | Forward-mounted hygienic CIP ports |
| System Architecture | Skid-mounted, container-ready, plug-and-play installation |
| Brand | ELGA VEOLIA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | PURENERGY 30 |
| Purified Water Grade | ASTM Type II |
| Resistivity | >1 MΩ·cm @ 25 °C |
| Total Organic Carbon (TOC) | <50 ppb |
| Brand | ELGA Veolia |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MEDICA–R 200 |
| Purified Water Grade | ASTM Type III / ISO 3696 Grade 3 |
| Resistivity | 10–18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <30 ppb |
| Microbial Count | <10 CFU/mL |
| Endotoxin | <0.001 EU/mL |
| Particulates (>0.1 µm) | <0.2 µm per mL |
| Flow Rate | 18–30 L/min (distribution network) |
| Brand | ELGA Veolia |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TERION™ S |
| Purified Water Grade | ASTM Type II / ISO 3696 Grade 2 |
| Resistivity | ≥10 MΩ·cm @ 25°C |
| Total Organic Carbon (TOC) | <100 ppb |
| Recovery Rate | ~70% |
| Desalination Efficiency | >99.5% |
| Membrane Technology | RO + Continuous Electrodeionization (CEDI) |
| System Architecture | Skid-mounted, Plug-and-Play |
| Control Interface | Hubgrade HMI/PLC Integrated Panel |
| Validation Support | FAT (Factory Acceptance Test) Wet Commissioning Protocol |
| Compliance | Meets ASTM D1193, ISO 3696, CLSI EP21-A, and EU GMP Annex 1 water system design principles |
| Brand | ELGA Veolia |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | TRITON |
| Pure Water Grade | ASTM Type II |
| Resistivity | 1–18.2 MΩ·cm at 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <10 ppb |
| Microbial Count | <0.25 EU/mL |
| Particulates (>0.1 µm) | <1 particle/mL |
| Flow Rate Options | 160, 240, 350, or 480 L/h |