GBPI
Filter
Showing 331–360 of 448 results
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W405G |
| Price Range | USD 14,000–28,000 |
| Test Range | 0.005–500 g/(m²·24h) |
| Measurement Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temp. Stability | ±0.1°C |
| Humidity Control Range | 30–90% RH (up to 100% RH optional) |
| Humidity Stability | ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | Ultra-high-purity N₂ (≥99.999%), inlet pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Fitting | 1/8″ stainless steel compression fitting |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | W405I |
| Pricing | Upon Request |
| Test Range | 0.005–500 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C |
| Humidity Control | 0% RH (dry), 30–90% RH, 100% RH, ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Power | 1000 W, AC 220 V / 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | W405WE |
| Price Range | USD 42,000 – 70,000 |
| Test Range | 0.005–500 g/(m²·24h) |
| Test Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temperature Stability | ±0.1 °C |
| Humidity Control Range | 0% RH (dry N₂), 30–90% RH, 100% RH |
| Humidity Stability | ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixture) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent test chambers |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Interface | 1/8″ stainless steel tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Power | 1000 W, AC 220 V, 50 Hz (110 V optional) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | W413 2.0 |
| Price | ¥368,000 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | W413 2.0M |
| Price Range | USD 42,000 – 70,000 |
| Measurement Principle | Infrared Detection of Water Vapor |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Test Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| RH Accuracy | ±1 %RH |
| Permeation Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 positions |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBPI W413 2.0 |
| Quotation | Upon Request |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per test cycle |
| Carrier Gas | Ultra-high-purity nitrogen (99.999%), ≥0.1 MPa supply pressure, 5–100 mL/min flow rate |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBPI W413 2.0B |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | GBPI W413 2.0C |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | W413 2.0K |
| Price Range | USD 42,000 – 70,000 |
| Test Principle | Infrared Detection of Moisture Permeation |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per cycle |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| N₂ Pressure | ≥0.1 MPa |
| N₂ Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | W413 2.0L |
| Price Range | USD 42,000–70,000 |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0%RH (dry), 30–90%RH, 100%RH |
| RH Accuracy | ±1%RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per run |
| Carrier Gas | ≥99.999% N₂ |
| Gas Pressure | ≥0.1 MPa |
| Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | W413 2.0R |
| Price Range | USD 42,000–70,000 |
| Measurement Principle | Infrared Detection of Moisture Permeation |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Test Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| Humidity Accuracy | ±1 %RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | 3 mm |
| Sample Capacity | 3 specimens per cycle |
| Carrier Gas | ≥99.999% N₂, 5–100 mL/min, ≥0.1 MPa pressure |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | W413 2.0S |
| Price Range | USD 42,000 – 70,000 |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0% (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per cycle |
| Carrier Gas | Ultra-high-purity N₂ (99.999%), ≥0.1 MPa supply pressure, 5–100 mL/min flow rate |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W413 2.0U |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, YBB 00092003-2015, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| Humidity Accuracy | ±1 %RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 positions |
| Carrier Gas | ≥99.999% N₂ |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W413D |
| Pricing | Upon Request |
| Test Range | 0.002–1000 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Temperature Control | 15–45°C (optional up to 60°C), ±0.1°C |
| Humidity Control | 0%, 30–90%, or 100% RH, ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Sample Diameter | Φ100 mm |
| Max Sample Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Power Supply | AC 220 V, 50 Hz (110 V optional) |
| Dimensions | 610 × 550 × 300 mm |
| Weight | 57.1 kg |
| Power Consumption | 1000 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W413Q |
| Test Range | 0.002–1000 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH |
| Humidity Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow 5–120 mL/min |
| Interface | 1/8″ metal tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz (110 V optional) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W413T |
| Price Range | USD 42,000 – 70,000 |
| Test Principle | Infrared Detection of Moisture Permeation |
| Standards Compliance | GB/T 26253-2010, YBB 00092003-2015, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per cycle |
| Carrier Gas | 99.999% high-purity N₂ (user-supplied) |
| Carrier Gas Pressure | ≥0.1 MPa |
| Carrier Gas Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Input Power | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | W413U |
| Price Range | USD 42,000–70,000 |
| Test Range | 0.002–1000 g/(m²·24h) |
| Test Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 30–90% RH |
| Humidity Control Accuracy | ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Carrier Gas Pressure | ≥0.1 MPa |
| Carrier Gas Flow Rate | 5–120 mL/min |
| Gas Inlet Port | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W413Z |
| Price Range | USD 42,000 – 70,000 |
| Test Range | 0.002–1000 g/(m²·24h) |
| Test Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temp. Control Accuracy | ±0.1°C |
| Humidity Control Range | 30–90% RH |
| Humidity Control Accuracy | ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | 99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W |
| Voltage | AC 220 V, 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W501 |
| Pricing | Upon Request |
| Measurement Principle | Gravimetric (Weight Gain) Method |
| Standards Compliance | GB/T 1037–1988, GB/T 16928–1997, ASTM E96/E96M–2016, ASTM D1653–2013, TAPPI T464, ISO 2528–1995, DIN 53122–1, JIS Z0208–1976, YBB00092003–2015 |
| Test Range | 0.1–10,000 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Weight Resolution | 0.1 mg |
| Temperature Control Range | 15–55 °C |
| Temp Stability | ±0.1 °C |
| Humidity Control Range | 30–90% RH and 100% RH |
| RH Accuracy | ±1% RH |
| Test Area | 86.54 cm² |
| Specimen Diameter | Φ125 mm |
| Max Thickness | ≤5 mm |
| Purge Air Velocity | 0.5–2.5 m/s |
| Interface | Φ4 mm polyurethane tubing |
| Air Supply Pressure | ≥0.2 MPa |
| Dimensions | 680 × 550 × 375 mm |
| Weight | 50 kg |
| Power | 500 W |
| Voltage/Frequency | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W533 |
| Measurement Principle | Gravimetric (Cup Method) |
| Test Range | 0.1–10,000 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Weight Resolution | 0.1 mg |
| Temperature Control Range | 15–55 °C |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 30–90% RH and 100% RH |
| Humidity Stability | ±1% RH |
| Test Area | 86.54 cm² |
| Specimen Diameter | Φ125 mm |
| Max. Specimen Thickness | ≤5 mm |
| Purge Air Velocity | 0.5–2.5 m/s |
| Interface | Φ4 mm polyurethane tubing |
| Supply Pressure | ≥0.2 MPa |
| Capacity | 3 test stations (expandable to 10) |
| Dimensions | 1680 × 500 × 375 mm |
| Weight | 160 kg |
| Power | 1000 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | W812 |
| Price | USD 55,000 (FOB Guangzhou) |
| Testing Principle | Gravimetric Cup Method (ASTM E96 / GB/T 1037) |
| Test Range | 0.05–10,000 g/(m²·24h) |
| Resolution | 0.0001 g/(m²·24h) |
| Test Stations | 12 |
| Balance Capacity | 220 g |
| Balance Readability | 0.1 mg (optional 0.01 mg) |
| Temperature Control Range | 10–50 °C ±0.1 °C |
| Humidity Control Range | 5–90 %RH ±2 %RH |
| Air Velocity | 0.3–2.5 m/s (optional low-flow 0.03–0.5 m/s) |
| Test Area | 33 cm² |
| Specimen Diameter | Φ74 mm |
| Max. Specimen Thickness | ≤3 mm |
| Test Modes | Gravimetric Gain & Loss Methods |
| Carrier Gas | Compressed Air ≥0.6 MPa |
| Dimensions | 830 × 670 × 440 mm |
| Weight | 75 kg |
| Power Supply | AC 220 V, 50 Hz |
| Compliance | ChP 2025 <4010>, ASTM E96, ASTM D1653, ISO 2528, GB/T 1037, GB/T 16928, GB/T 17146, GB/T 12704, GB/T 19082, GB/T 21332, TAPPI T464, DIN 53122-1, YBB00092003 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | W900 |
| Price Range | USD 70,000 – 140,000 |
| Measurement Principle | Gravimetric Cup Method (ASTM E96 / GB/T 1037) |
| Test Modes | Gain-Weight & Loss-Weight |
| Test Stations | 9 |
| WVTR Range (Film) | 0.05–10,000 g/m²·24h |
| WVTR Range (Container) | 0.0002–30 g/pkg·24h |
| Mass Resolution | 0.1 mg |
| Temperature Control | 10–50 ±0.1 °C |
| Humidity Control | 5–95% RH, up to 100% RH |
| Airflow Velocity | 0.5–2.5 m/s (optional low-flow: 0.03–0.5 m/s) |
| Sample Diameter | Φ74 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 33 cm² |
| Carrier Gas | Compressed air (≥0.6 MPa), Φ6 mm polyurethane tubing |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W900 |
| Price Range | USD 42,000 – 70,000 |
| Measurement Range (Film) | 0.05–10,000 g/(m²·24h) |
| Measurement Range (Container) | 0.0002–30 g/(pkg·24h) |
| Test Accuracy (Film) | ±0.05 g/(m²·24h) |
| Test Accuracy (Container) | ±0.0002 g/(pkg·24h) |
| Test Stations | 9 |
| Balance Capacity | 210 g |
| Balance Resolution | 0.1 mg |
| Temperature Range | 10–50 ±0.1 °C |
| Humidity Range | 5–95 %RH |
| Air Velocity | 0.5–2.5 m/s (optional low-flow mode: 0.03–0.5 m/s) |
| Sample Diameter | Φ74 mm |
| Max Sample Thickness | ≤3 mm |
| Standard Test Area | 33 cm² |
| Carrier Gas | Compressed air (≥0.6 MPa) |
| Tubing Interface | Φ6 mm polyurethane |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | W900e |
| Price | ¥900,000 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | WSB-L |
| Price | Upon Request |
| Measurement Range | 0–120% |
| Resolution | 0.1% |
| Illumination Geometry | 45°/0° |
| Peak Wavelength | 457 nm |
| Detector | Silicon Photodiode |
| Stability | ±0.2% |
| Repeatability | 0.3% |
| Accuracy (Indication Error) | ±1.5% |
| Compliance Standards | GB/T 5950, GB/T 2931, GB/T 8940.1 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | XDLLX |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | XF-10010Q |
| Instrument Category | Aerosol Detector |
| Sampling Flow Rate (A/B) | 28.3 L/min ±2.5% |
| Nebulizer Flow Rate | (8–10) L/min ±2.5% |
| Peristaltic Pump Flow Range | (0.006–3.0) mL/min ±2.5% |
| Pressure Measurement Accuracy | ±2.5% (except aerosol chamber: ±2.0%) |
| Aerosol MMAD | 3.0 ± 0.3 µm, GSD ≤1.5 |
| Andersen Cascade Impactor Stages | 6-stage (I–VI), cutpoints: >7, 4.7–7, 3.3–4.7, 2.1–3.3, 1.1–2.1, 0.6–1.1 µm |
| Aerosol Chamber Dimensions | 600 × 85 × 30 mm (Lר×T) |
| Cabinet Negative Pressure | –50 to –200 Pa |
| Aerosol Chamber Negative Pressure | –90 to –120 Pa |
| Temperature Range | –40 to 99 °C ±2.5% |
| Data Storage Capacity | >100,000 test records |
| HEPA Filter Efficiency | ≥99.99% @ ≥0.3 µm |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Net Weight | ~150 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | XF-10010 |
| Instrument Type | Aerosol Detector |
| A-Path Sampling Flow | 28.3 L/min ±2.5% (0.1 L/min resolution) |
| B-Path Sampling Flow | 28.3 L/min ±2.5% (0.1 L/min resolution) |
| Nebulizer Flow | (8–10) L/min ±2.5% (0.1 L/min resolution) |
| Peristaltic Pump Flow | (0.006–3.0) mL/min ±2.5% (0.001 mL/min resolution) |
| Pressure Before A/B Flowmeters | (−20–0) kPa ±2.5% (0.01 kPa resolution) |
| Pressure Before Nebulizer | (0–300) kPa ±2.5% (0.1 kPa resolution) |
| Ambient Temperature Range | (−40–99) °C ±2.5% (0.1 °C resolution) |
| Aerosol Chamber Negative Pressure | (−90–−120) Pa ±2.0% (0.1 Pa resolution) |
| Cabinet Negative Pressure | −50 to −200 Pa |
| Data Storage Capacity | >100,000 test records |
| Vortex Mixer | 8 × Φ16×150 mm tubes |
| HEPA Filter Efficiency | ≥99.99% for particles ≥0.3 µm |
| Aerosol Generator MMAD | 3.0 ± 0.3 µm, GSD ≤1.5 |
| Andersen Six-Stage Impactor Cut Points | Stage I >7 µm, II: 4.7–7 µm, III: 3.3–4.7 µm, IV: 2.1–3.3 µm, V: 1.1–2.1 µm, VI: 0.6–1.1 µm |
| Aerosol Chamber Dimensions | 60 cm (L) × 8.5 cm (Ø) × 3 cm (T) |
| Positive Control Target | 2200 ± 500 CFU |
| Cabinet Ventilation Flow Rate | ≥5 m³/min |
| Cabinet Door Size | W1000 × D730 mm |
| Main Unit Dimensions | W1180 × D650 × H1300 mm |
| Adjustable Stand Dimensions | W1180 × D650 × H600 mm (±10 cm height adjustment) |
| Noise Level | <65 dB(A) |
| Weight | ~150 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | <1500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic |
| Model | Y110 2.0 |
| Price | USD 39,500 (FOB Guangzhou) |
| Test Principle | Coulometric Sensor (ASTM D3985 / ISO 15105-2) |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1037, ISO 15105-2, JIS K-7126-B, DIN 53380-3, YBB00082003 |
| Measurement Range | 0.02–16,500 cm³/(m²·24 h) [up to 260,000 cm³/(m²·24 h) with optional mask fixture] |
| Resolution | 0.001 cm³/(m²·24 h) |
| Temperature Control | 15–45 °C ±0.1 °C |
| Humidity Control | 0% RH (dry), 30–90% RH, 100% RH ±1% RH |
| Test Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1 specimen per test cycle |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | Φ3 mm tubing / 1/8" NPT |
| Dimensions | 600 × 400 × 330 mm |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | Y110 |
| Price Range | USD 14,000 – 70,000 |
| Testing Principle | Coulometric Sensor-Based Oxygen Permeation Measurement |
| Standards Compliance | GB/T 19789–2005, YBB 00082003–2015, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K 7126-B |
| OTR Range | 0.02–16,500 cm³/(m²·24h) (up to 260,000 cm³/(m²·24h) with optional face mask adapter) |
| OTR Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45 °C, ±0.1 °C |
| Humidity Control | 30–90% RH (and 100% RH), ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with accessory kits) |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1 unit per test |
| Carrier Gas Pressure | ≥0.1 MPa |
| Gas Inlet | Φ3 mm tubing / 1/8″ NPT |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |