| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | W303 |
| Pricing | Upon Request |
| Test Principle | Gravimetric (Weight Gain/Loss Method) |
| Standards Compliance | GB/T 1037–1988, GB/T 16928–1997, ASTM E96/E96M–2016, ASTM D1653–2013, ISO 2528–1995, TAPPI T464, DIN 53122-1, JIS Z0208–1976, YBB00092003–2015 |
| Measurement Range | 0.1–10,000 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–55 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range (Desiccant Method) | ≤10 %RH |
| Humidity Accuracy | ±1 %RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ90 mm |
| Max Specimen Thickness | 3 mm |
| Specimen Capacity | 3 units per test cycle |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 450 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | W303 |
| Measurement Range | 0.02–10,000 g/(m²·24h) |
| Measurement Resolution | 0.001 g/(m²·24h) |
| Temperature Range | 15–45 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Humidity Range | 30–90 %RH (standard setpoint: 90 %RH, dual-airflow humidity control) |
| Humidity Control Accuracy | ±2 %RH |
| Sample Thickness Limit | ≤2 mm |
| Sample Diameter | Ø90 mm |
| Test Area | 50.24 cm² |
| Specimen Capacity | 3 chambers |
| Dimensions (W×D×H) | 520×420×340 mm |
| Power Supply | 220 V AC, 50 Hz |
| Compliance | GB/T 1037–1988, GB/T 16928, ASTM E96, ASTM D1653, TAPPI T464, ISO 2528, DIN 53122-1, JIS Z0208, YBB00092003 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W360 |
| Pricing | Upon Request |
| Measurement Range | 0.01–10,000 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Range | 10–50 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Range | 0–20 %RH (desiccant method) |
| Humidity Accuracy | ±2 %RH |
| Max Sample Thickness | ≤2 mm |
| Sample Quantity | 1–6 specimens |
| Sample Diameter | Φ60 mm |
| Test Area | 28.2744 cm² |
| Compliance Standards | GB 1037, GB/T 17146, GB/T 16928, ASTM E96, ASTM D1653, TAPPI T464, ISO 2528, DIN 53122-1, JIS Z0208, YBB 00092003 |
| Brand | GBPI |
|---|---|
| Model | W401 |
| Measurement Principle | Infrared Detection |
| Test Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C accuracy |
| Humidity Control | 30–90 %RH (up to 100 %RH), ±1 %RH accuracy |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Sample Size | Ø100 mm |
| Max Sample Thickness | ≤3 mm |
| Carrier Gas | Ultra-high-purity N₂ (99.999 %), 0.1 MPa min pressure, 5–120 mL/min flow rate |
| Power Supply | AC 220 V, 50 Hz, 750 W |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | W401-1 |
| Pricing | Upon Request |
| Brand | GBPI |
|---|---|
| Model | W401-i |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price Range | USD 14,000–28,000 |
| Test Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Accuracy | ±0.1 °C |
| Humidity Range | 30–90 %RH |
| RH Accuracy | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1 unit per test |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | W401-M |
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Category | Packaging Industry–Specific WVTR Tester |
| Standards Compliance | GB/T 26253-2010, YBB 00092003-2015, ISO 15106-2:2005, ASTM F1249-2013, JIS K7129:2008 |
| Measurement Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C accuracy |
| Humidity Control | 30–90 %RH, ±1 %RH accuracy |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Carrier Gas | 99.999 % N₂, 0.1 MPa min pressure, 5–120 mL/min flow |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | W401A |
| Measurement Principle | Infrared Detection |
| Test Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C accuracy |
| Humidity Control | 30–90% RH (up to 100% RH), ±1% RH accuracy |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Sample Diameter | Φ100 mm |
| Max Sample Thickness | ≤3 mm |
| Carrier Gas | Ultra-high-purity N₂ (99.999%), 0.1 MPa min pressure, 5–120 mL/min flow |
| Power | 750 W, AC 220 V / 50 Hz |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | W401C |
| Price Range | USD 14,000 – 28,000 |
| Test Principle | Infrared Moisture Detection |
| Standard Compliance | GB/T 26253 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| RH Accuracy | ±1 %RH |
| Permeation Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 1 test chamber |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| N₂ Pressure | ≥0.1 MPa |
| N₂ Flow Rate | 5–100 mL/min |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | W401P 2.0 |
| Price Range | USD 39,800 – 52,700 |
| Test Principle | Infrared Detection of Moisture Permeation |
| Standards Compliance | GB/T 31355-2014, GB/T 26253-2010, YBB 00092003, ChP IV <4010>, ASTM F1249, ISO 15106-2, JIS K7129 |
| Test Range (Packaged Goods) | 0.00001–0.5 g/(pkg·day) |
| Test Range (Film) | 0.002–100 g/(m²·24h) |
| Resolution (Packaged Goods) | 0.0001 g/(pkg·day) |
| Resolution (Film) | 0.0001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.5 °C |
| Humidity Control Range | 20–95 %RH |
| Humidity Accuracy | ±2 %RH |
| Sample Capacity | 1 packaged unit per test cycle |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Interface | 1/8″ stainless steel tubing |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | W401P 2.0B |
| Test Principle | Infrared Detection of Moisture via Carrier Gas (N₂) |
| Standards Compliance | GB/T 31355-2014, GB/T 26253-2010, YBB 00092003, ChP IV <4010>, ASTM F1249, ISO 15106-2, JIS K7129 |
| Temperature Control Range | 15–45 °C ±0.5 °C |
| Humidity Control Range | 20–95 %RH ±2 %RH |
| WVTR Range (Packaging) | 0.00001–0.5 g/(pkg·day) |
| WVTR Range (Film) | 0.002–100 g/(m²·24h) |
| Resolution (Packaging) | 0.0001 cc/(pkg·day) |
| Resolution (Film) | 0.0001 g/(m²·24h) |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Interface | 1/8″ stainless steel tubing |
| Sample Capacity | 1 packaging unit per test cycle |
| Integrated Water Reservoir | High-capacity for extended unattended operation |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | W401P |
| Price Range | USD 39,800 – 52,700 |
| Brand | GBPI |
|---|---|
| Model | W401R |
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instrument Co., Ltd. |
| Testing Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C accuracy |
| Humidity Control | 30–90 %RH, ±1 %RH accuracy |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Ø100 mm, ≤3 mm thickness |
| Carrier Gas | 99.999% N₂, 0.1 MPa min pressure, 5–120 mL/min flow |
| Power | AC 220 V, 50 Hz, 750 W |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Brand | GBPI |
|---|---|
| Model | W401U |
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instrument Co., Ltd. |
| Application | WVTR measurement of thin films and packaging materials for lithium-ion battery separators, flexible electronics, and pharmaceutical packaging |
| Standards Compliance | GB/T 26253-2010, YBB 00092003-2015, ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Measurement Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control | 15–45 °C (optional up to 60 °C), ±0.1 °C accuracy |
| Humidity Control | 30–90 %RH, ±1 %RH accuracy |
| Test Area | 50.24 cm² (configurable down to 0.785 cm² with optional fixtures) |
| Specimen Size | Ø100 mm, ≤3 mm thickness |
| Carrier Gas | Ultra-high-purity N₂ (≥99.999 %), 0.1 MPa minimum pressure, 5–120 mL/min flow rate |
| Power Supply | AC 220 V, 50 Hz, 750 W |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | W401X |
| Price Range | USD 28,000 – 42,500 |
| Test Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temp. Accuracy | ±0.1°C |
| Humidity Control Range | 30–90% RH |
| RH Accuracy | ±1% RH |
| Permeation Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 1 unit |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Dimensions | 600 × 400 × 330 mm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | W403 |
| Price Range | USD 150–15,000 (FOB Guangdong) |
| Measurement Principle | Infrared Sensor Method |
| Standards Compliance | ISO 15106-2, ASTM F1249, TAPPI T557, JIS K7129, GB/T 26253 |
| WVTR Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) (for films & sheets) |
| Temperature Control | 15–45 °C (optional 5–55 °C), ±0.1 °C accuracy |
| Humidity Control | 0%, 30–90% RH, 100% RH, ±1% RH accuracy |
| Test Chambers | 3 independent chambers |
| Sensor Count | 3 infrared hygrometric sensors |
| Specimen Size | Ø100 mm (50.24 cm² test area), thickness ≤2 mm |
| Carrier Gas | Ultra-high-purity nitrogen (99.999%), inlet pressure ≥0.1 MPa, flow rate 0–100 mL/min |
| Interface | 1/8″ stainless steel tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Power | 220 V, 50 Hz (110 V optional) |
| Power Consumption | 500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | W403-D |
| Test Range | 0.001–100 g/m²·24h (films & sheets) |
| Measurement Accuracy | 0.001 g/m²·24h |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temperature Stability | ±0.1°C |
| Humidity Control Range | 0% RH (dry), 30–90% RH, and 100% RH |
| Humidity Stability | ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max. Specimen Thickness | ≤2 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Carrier Gas Pressure | ≥0.1 MPa |
| Carrier Gas Flow Rate | 5–120 mL/min |
| Gas Inlet Port | 1/8″ metal tubing |
| Dimensions | 61 × 55 × 40 cm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Compliance | GB/T 26253-2010, YBB 00092003-2015, BS EN ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Brand | GBPI |
|---|---|
| Model | W403-F |
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Packaging Industry–Specific WVTR Tester |
| Compliance Standards | GB/T 26253-2010, YBB 00092003-2015, ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Test Range | 0.001–100 g/m²·24h |
| Test Accuracy | ±0.001 g/m²·24h |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temp. Stability | ±0.1°C |
| Humidity Control Range | 0% RH (dry), 30–90% RH, and 100% RH |
| Humidity Stability | ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Ø100 mm |
| Max. Specimen Thickness | ≤2 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | Ultra-high-purity N₂ (99.999%), pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Interface | 1/8″ stainless steel tubing |
| Dimensions | 61 × 55 × 40 cm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Model | W403-G |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Price Range | USD 1–9,999 |
| Testing Range | 0.001–100 g/m²·24h (films & sheets) |
| Test Accuracy | 0.001 g/m²·24h |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temp. Stability | ±0.1°C |
| Humidity Control Range | 0%RH (dry), 30–90%RH, 100%RH |
| Humidity Stability | ±1%RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max. Specimen Thickness | ≤2 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tube |
| Dimensions | 61 × 55 × 40 cm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Compliance | GB/T 26253-2010, YBB 00092003-2015, BS EN ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W403A |
| Moisture Permeation Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) (for films & sheets) |
| Temperature Control Range | 15–45°C (optional 5–55°C) |
| Temperature Accuracy | ±0.1°C |
| Humidity Control Range | 0% RH, 30–90% RH, 100% RH |
| Humidity Accuracy | ±1% RH |
| Specimen Quantity | 3 |
| Sensors | 3 infrared moisture sensors |
| Specimen Size | Φ100 mm (test area: 50.24 cm²) |
| Max. Specimen Thickness | ≤2 mm |
| Carrier Gas | Ultra-high-purity nitrogen (99.999%), ≥0.1 MPa pressure |
| Gas Flow Rate | 0–100 mL/min |
| Interface | 1/8″ stainless-steel tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Power | 220 V, 50 Hz (110 V optional) |
| Power Consumption | 500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | W403B |
| Measurement Principle | Infrared Sensor Method |
| Standards Compliance | ISO 15106-2, ASTM F1249, TAPPI T557, JIS K7129, GB/T 26253 |
| WVTR Range | 0.001–100 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) (for films & sheets) |
| Temperature Control Range | 15–45 °C (optional 5–55 °C) |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0 %RH, 30–90 %RH, 100 %RH |
| Humidity Accuracy | ±1 %RH |
| Sample Capacity | 3 test positions |
| Sensor Count | 3 infrared hygrometric sensors |
| Specimen Size | Ø100 mm (effective area: 50.24 cm²) |
| Max. Sample Thickness | ≤2 mm |
| Carrier Gas | Ultra-high-purity nitrogen (≥99.999 %), inlet pressure ≥0.1 MPa |
| Gas Flow Rate | 0–100 mL/min |
| Interface | 1/8″ stainless steel tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 80 kg |
| Power Supply | 220 V, 50 Hz (110 V optional) |
| Power Consumption | 500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W403C |
| Test Range | 0.001–100 g/m²·24h |
| Test Accuracy | 0.001 g/m²·24h |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 0% RH (dry), 30–90% RH, and 100% RH |
| Humidity Control Accuracy | ±1% RH |
| Permeation Area | 50.24 cm² (reducible to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Specimen Thickness | ≤2 mm |
| Sample Capacity | 2 independent test chambers |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Dimensions | 61 × 55 × 40 cm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Compliance Standards | GB/T 26253-2010, YBB 00092003-2015, BS EN ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | W405 |
| Test Range | 0.0005–500 g/(m²·24h) |
| Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH, 100 %RH |
| RH Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999 % N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Interface | 1/8″ metal tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V, 50 Hz (110 V optional) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | W405 |
| Price Range | USD 42,000 – 70,000 |
| Test Principle | Infrared Detection of Moisture |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Test Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temp. Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| RH Accuracy | ±1 %RH |
| Permeation Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per test cycle |
| Carrier Gas | Ultra-high-purity N₂ (99.999%, user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–100 mL/min |
| Power | 750 W, AC 220 V / 50 Hz |
| Brand | GBPI |
|---|---|
| Model | W405-A |
| Measurement Principle | Infrared Detection of Water Vapor |
| Test Range | 0.005–500 g/(m²·24h) |
| Accuracy | ±0.001 g/(m²·24h) |
| Temperature Control | 15–45°C (optional up to 60°C), ±0.1°C |
| Humidity Control | 0%, 30–90%, or 100% RH, ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Sample Size | Ø100 mm, ≤3 mm thickness |
| Sample Capacity | 1–3 specimens per run |
| Carrier Gas | High-purity nitrogen (99.999%), 5–120 mL/min, ≥0.1 MPa |
| Power | AC 220 V, 50 Hz, 1000 W |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W405-LP |
| Price Range | USD 42,000 – 70,000 |
| Test Range | 0.005–500 g/(m²·24h) |
| Test Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Stability | ±0.1 °C |
| Humidity Control Range | 0% RH (dry N₂), 30–90% RH, 100% RH |
| Humidity Stability | ±1% RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixture) |
| Specimen Size | Ø100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 specimens per test cycle |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Interface | 1/8″ metal tubing |
| Dimensions | 610 × 550 × 400 mm |
| Weight | 57.1 kg |
| Power | 1000 W, AC 220 V, 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W405A |
| Test Range | 0.0005–500 g/(m²·24h) |
| Measurement Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temperature Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH (and 100 %RH) |
| Humidity Stability | ±1 %RH |
| Test Area | 50.24 cm² (reducible to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999% N₂, pressure ≥0.1 MPa, flow rate 5–120 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz (110 V optional) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W405B |
| Test Range | 0.0005–500 g/(m²·24h) (films & sheets) |
| Measurement Accuracy | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temperature Stability | ±0.1 °C |
| Humidity Control Range | 30–90 %RH (and 100 %RH) |
| Humidity Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999 % N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz (110 V available on request) |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer | GBPI Packaging Instruments Co., Ltd. |
| Model | W405C |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Standard Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Test Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0–100 %RH (dual-stream dry/wet gas method) |
| Humidity Accuracy | ±1 %RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max. Specimen Thickness | ≤3 mm |
| Carrier Gas | High-purity N₂ (≥99.999%, 0.1–0.6 MPa, 5–100 mL/min) |
| Power Supply | AC 220 V, 50 Hz, 750 W |
| Sample Capacity | 3 positions |
| Data Integrity | Audit trail, electronic signatures, 21 CFR Part 11–compliant software architecture |
| Key | Brand: GBPI |
|---|---|
| Model | W405D |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | Domestic (China) |
| Test Range | 0.0005–500 g/(m²·24h) |
| Accuracy | ±0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C (optional up to 60 °C) |
| Temp. Stability | ±0.1 °C |
| Humidity Range | 30–90 %RH (including 100 %RH) |
| RH Stability | ±1 %RH |
| Test Area | 50.24 cm² (down to 0.785 cm² with optional fixtures) |
| Specimen Size | Φ100 mm |
| Max. Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas | ≥99.999% N₂, 0.1 MPa min. pressure, 5–120 mL/min flow |
| Interface | 1/8″ metal tubing |
| Dimensions | 700 × 560 × 370 mm |
| Weight | 80 kg |
| Power | 750 W, AC 220 V / 50 Hz (110 V available on request) |