Generic
Filter
Showing 5011–5040 of 5668 results
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3080 |
| Pricing | Available Upon Request |
| Particle Type | Solid or Non-Volatile Liquid |
| Size Range (3080L) | 10–1000 nm |
| Size Range (3080N) | 2–150 nm |
| Max Concentration | 1 × 10⁸ #/cm³ |
| Aerosol Flow Rate | 0.2–3 L/min (model-dependent) |
| Sheath Gas Flow Rate | 2–20 L/min (model-dependent) |
| Operating Temperature | 7–43 °C |
| Operating Pressure | 1 ± 0.2 atm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3089 |
| Pricing | Available Upon Request |
| Operating Principle | Electrostatic Deposition |
| Particle Type | Solid or Non-Volatile Liquid Aerosols |
| Size Range | 2–100 nm |
| Flow Rate | 0.2–2.5 L/min |
| Ambient Temperature | 10–50 °C |
| Relative Humidity | 0–90 % RH (non-condensing) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3160 |
| Price Range | USD 65,000–130,000 |
| Instrument Type | Aerosol Filter Tester |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3306 |
| Pricing | Available Upon Request |
| 50% Cut-Point | 2.5 µm or 4.7 µm |
| Collection Filter | 47 mm diameter |
| Maximum Particle Loss | ≤3% |
| Sampling Flow Rate | 28.3 L/min |
| Vacuum Requirement | 28.3 L/min at 460 mmHg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3787 / 3788 |
| Instrument Type | Aerosol Detector |
| Minimum Detectable Particle Size (D₅₀) | 5 nm |
| Maximum Counting Concentration | 250,000 cm⁻³ |
| Aerosol Flow Rate | 0.6 ± 0.06 L/min |
| High-Flow Mode | 1.5 ± 0.15 L/min |
| Response Time (10–90%) | < 300 ms |
| Time Constant | ~130 ms |
| Background Count | < 0.01 cm⁻³ (hourly average) |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Working Fluid | Deionized or Ultrapure Water |
| Water Reservoir | External 1 L (3-day operation) or optional 4 L (12-day operation) |
| Water Consumption | ~300 mL/day |
| Vacuum Source | Integrated diaphragm pump |
| Compliance | Manufactured per ISO 9001 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9535 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9515 |
| Price | Upon Request |
| Air Velocity Range | 0–4000 ft/min (0–20 m/s) |
| Accuracy | ±5% of reading or ±5 ft/min (±0.025 m/s), whichever is greater |
| Resolution | 1 ft/min (0.01 m/s) |
| Temperature Range | –18 to 93 °C (0 to 200 °F) |
| Temperature Accuracy | ±0.3 °C (±0.5 °F) |
| Temperature Resolution | 0.1 °C (0.1 °F) |
| Operating Temperature (Instrument) | 5–45 °C (40–113 °F) |
| Operating Temperature (Sensor, 9515) | –18–93 °C (0–200 °F) |
| Storage Temperature | –20–60 °C (–4–140 °F) |
| Dimensions (9515) | 8.4 × 17.8 × 4.4 cm (3.3 × 7.0 × 1.8 in) |
| Probe Length (9515) | 101.6 cm (40 in) |
| Probe Tip Diameter (9515) | 7.0 mm (0.28 in) |
| Probe Base Diameter (9515) | 13.0 mm (0.51 in) |
| Weight (with batteries) | 0.27 kg (0.6 lb) |
| Power Supply | 4 × AA batteries |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 9565 Series |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5725 |
| Instrument Type | Vane Anemometer |
| Velocity Range | 0.25–30 m/s (50–6000 ft/min) |
| Accuracy (Velocity) | ±1.0% of reading or ±0.02 m/s (±4 ft/min), whichever is greater |
| Temperature Range | 0–60 °C (32–140 °F) |
| Temperature Accuracy | ±0.5 °C (±2 °F) |
| Temperature Resolution | 0.1 °C (0.1 °F) |
| Duct Area Range | 0–16 m² (0–173.6 ft²) |
| Volume Flow Calculation | Enabled via user-input duct geometry/area |
| Operating Temp (Instrument) | 5–45 °C |
| Operating Temp (Probe) | 0–60 °C |
| Storage Temp | −20–60 °C |
| Data Memory | 12,700 readings + 100 data sets |
| Sampling Interval | 1 s – 1 h |
| User-Defined Time Constant | Yes |
| Display | Real-time velocity, temperature, min/max, and rolling average |
| Probe | 100 mm (4 in.) bidirectional vane |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with battery) | 270 g |
| Power | One 9V alkaline or NiCd battery |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | P4000 / AS3000 |
| Operational Age | 4–5 Years |
| Warranty | 6 Months |
| Product Category | Chromatography Systems |
| Compliance | Fully Refurbished & Factory-Tested |
| Origin | Liaoning, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | TSY Series |
| Pricing | Available Upon Request |
| X-ray Tube Voltage Range | 20–225 kV |
| Tube Current Range | 1–50 mA |
| High-Voltage Generator Weight | 210 kg |
| Cooling System | TZL-30 (integrated) or TZL-30F (split-type), temperature control range: 0–50 °C, accuracy: ±0.5 °C |
| Water Flow Rate | 1.6–3.0 L/min |
| Output Pressure | 2.5–4 kg/cm² |
| Control Interface | Color TFT touchscreen, Chinese-language UI |
| Safety Interlocks | Overcurrent, overvoltage, undervoltage, undercurrent, water flow loss, overheating, door interlock |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LT880 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TU-1810 |
| Quotation | Upon Request |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.3 nm (auto-calibrated at startup) |
| Wavelength Repeatability | 0.2 nm |
| Spectral Bandwidth | Fixed 2 nm |
| Stray Light | <0.3%T (220 nm, NaI |
| Photometric Modes | Transmittance (%T), Absorbance (Abs), Energy |
| Photometric Range | −0.3 to 3.0 Abs |
| Photometric Accuracy | ±0.002 Abs (0–0.5 Abs) |
| Photometric Repeatability | 0.001 Abs (0–0.5 Abs) |
| Baseline Flatness | ±0.002 Abs (190–1100 nm) |
| Baseline Drift | 0.001 Abs/h (500 nm, 0 Abs, after 2 h warm-up) |
| Photometric Noise | ±0.001 Abs (500 nm, 0 Abs, 2 nm SBW) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TURACO |
| Core Technology | Er/Yb-Doped Nanosecond Fiber Laser with Integrated Second-Harmonic Generation (SHG) |
| Pulse Energy | Up to 50 µJ |
| Peak Power | Up to 15 kW |
| Average Output Power | Up to 2 W |
| Repetition Rate | 10–200 kHz |
| Beam Quality | Diffraction-Limited (M² < 1.3) |
| Wavelength | 532 nm (frequency-doubled) |
| Operating Voltage | +24 V DC |
| Power Consumption | < 12 W |
| Weight | < 650 g |
| Cooling | Conductive, Fanless |
| Compliance | CE, RoHS, IEC 60825-1:2014 Class 4 Laser Product |
| Origin | Netherlands |
|---|---|
| Model | TV2000AKV |
| Temperature Range | Ambient +5 °C to 130 °C |
| Temperature Stability | ±0.01 °C |
| Temperature Uniformity | ±0.01 °C |
| Temperature Resolution | ±0.1 °C |
| Timing Accuracy | ±0.01 s |
| Max Timer Duration | 9999.99 s |
| Bath Capacity | 20 L |
| Heating Power | 200 / 1000 / 1500 W (triple-zone) |
| Construction Materials | AISI 304 stainless steel and PTFE |
| Safety Compliance | CE Directive |
| Dimensions (L×W×H) | 285 × 465 × 585 mm |
| Weight | 40 kg |
| Total Power Consumption | 2800 W |
| Optical Detection | Dual infrared sensors |
| Capillary Types Supported | Ubbelohde and Cannon-Fenske |
| Viscosity Range | 0.3 – 10,000 cSt |
| Calibration Storage | Up to 10 capillary constants |
| Optional Chiller Compatibility | TLC2 (enables 10 °C operation) |
| Standards Compliance | ASTM D445, ASTM D446, IP 71 |
| Key Features | Dual-chamber design (hot/cold) with pneumatic door switching |
|---|---|
| Temperature Range | Hot Zone RT to +200°C, Cold Zone RT to −70°C |
| Test Zone Range | +60°C to +150°C (heat shock), 0°C to −45/−55/−65°C (cold shock) |
| Temperature Uniformity | ±2.0°C |
| Temperature Control Accuracy | ±0.5°C |
| Recovery Time | <5 min |
| Preheating Time (RT→150°C) | ~30 min |
| Precooling Time (RT→−70°C) | ~85 min |
| Refrigeration System | Twin-stage cascade refrigeration using R404A/R23 |
| Construction | Interior – SUS#304 mirror-finish stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Optional Customization | Internal dimensions scalable per user requirements |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-assembled) |
| Model | TX-500C |
| Price Range | USD 14,000 – 28,500 |
| Surface/Interfacial Tension Range | 1×10⁻⁶ – 100 mN/m |
| Measurement Resolution | 0.001 mm |
| Measurement Accuracy | ±0.1% of reading |
| Temperature Control Range | 0–100 °C |
| Temperature Accuracy | ±0.1 °C |
| Measurement Method | Rotating Drop |
| Origin | Russia |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LPF |
| Component Category | Optical Element |
| Price | USD 1,120 (est.) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | TYS-3672A |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentine Phosphate Online Monitor |
| Instrument Type | Phosphate (Orthophosphate) Analyzer |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 mg/L |
| Repeatability | ±2% of reading or full scale |
| Measurement Cycle | 5 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature Range | 5–70 °C |
| Max. Suspended Solids | 2% w/w, max. particle size 1.27 mm |
| Sample Pressure Range | 0–345 kPa (0–50 psig) |
| Drain Outlet | 3/4" NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully configured) |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentine Sulfide Ion Online Monitor |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Principle | Colorimetric (with DMPD Oxalate Reagent) |
| Range | 0–5 ppm (customizable for higher ranges) |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±2% of reading or full scale |
| Measurement Wavelength | 650 nm |
| Reference Wavelength | 810 nm |
| Cycle Time | 15 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Volume per Analysis | 30 mL |
| Sample Temperature Range | 5–70 °C |
| Max. Suspended Solids | 2% w/v, max. particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Sample Interface | 1/4" compression fitting |
| Effluent Port | 3/4" NPT male, atmospheric vent |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted (hardware included) |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully configured) |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Amine Concentration and H₂S/CO₂ Acid Gas Online Analyzer |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Chromium Ion Online Monitor |
| Price | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Chromium Ion Online Monitor |
| Price | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Cu Ion Online Monitor |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Principle | Colorimetric Spectrophotometry (Bathocuproine or Neocuproine Method) |
| Range | 0–10 ppm (Low), 0–20 ppm (High) |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±2% of reading or full scale |
| Cycle Time | 5–15 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, particle size ≤1.27 mm |
| Sample Pressure | 0–50 psig |
| Sample Interface | 1/4" compression fitting |
| Waste Outlet | 3/4" NPT male, atmospheric discharge |
| Analog Output | 4–20 mA, user-configurable |
| Alarm Outputs | Programmable digital relays |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with integrated hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Fluoride Ion Online Monitor |
| Instrument Type | Fluoride Ion Analyzer |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) |
| Range | 0–20 ppm |
| Accuracy | ±5% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±5% of reading or full scale |
| Cycle Time | 2 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Max. Suspended Solids | 2% w/w, max. particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4" NPT male, open drain |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Dimensions (W×H×D) | 610 × 640 × 330 mm |
| Weight | ~36 kg (fully assembled) |
| Mounting | Wall-mounted with included hardware |
| Certifications | CE-compliant, designed to meet general requirements for industrial environmental monitoring installations |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Hydrochloric Acid Concentration Analyzer |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Nitrate Online Monitor |
| Instrument Type | Nitrate Ion (NO₃⁻) Analyzer |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range Options | 0–10 ppm, 0–50 ppm, 0–100 ppm |
| Accuracy | ±5% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±5% of reading or full scale |
| Cycle Time | 2 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Inlet | 1/4″ compression fitting |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, max particle size 1.27 mm (0.05″) |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4″ NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Dimensions (W×H×D) | 610 × 640 × 330 mm |
| Weight | ~36 kg (fully assembled) |
| Mounting | Wall-mounted with included hardware |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Silicon Online Analyzer |
| Instrument Type | Silica (Orthosilicic Acid) Analyzer |
| Measurement Principle | Colorimetric Spectrophotometry (Molybdenum Blue Method) |
| Detection Wavelengths | 810 nm (low-range), 312 nm (high-range) |
| Range Options | 0–100 ppb, 0–500 ppb, 0–1000 ppb, 0–2 ppm, 0–5 ppm, 0–10 ppm |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppb (at lowest range) |
| Repeatability | ±2% of reading or full scale |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, particle size ≤ 1.27 mm |
| Sample Pressure | 0–50 psig |
| Drain Outlet | 3/4" NPT male, atmospheric vent |
| Alarm Outputs | User-programmable digital relays |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with integrated hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully assembled) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Sodium Ion Online Monitor |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principle | Ion-Selective Electrode (ISE) with Single Standard Addition (SSA/SKA) Method |
| Range | High Range 0–200 ppm, Low Range 0–200 ppb |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppm/ppb |
| Repeatability | ±2% of reading or full scale |
| Sample Volume | 19 mL |
| Reagent Consumption | 2 mL per analysis |
| Sample Flow Rate | 50–900 mL/min |
| Sample Inlet | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Suspended Solids | ≤2% w/w, max particle size 0.05" (1.27 mm) |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4" NPT male, open drain |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted (hardware included) |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully assembled) |
