Generic
Filter
Showing 1381–1410 of 5725 results
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ES-20 |
| Quotation | Available Upon Request |
| Speed Range | 50–250 rpm |
| Orbit Diameter | 10 mm |
| Temperature Range | 25–42 °C |
| Temperature Resolution | 0.1 °C |
| Timer Range | 1 min – 96 h |
| Max Load Capacity | 2.5 kg |
| Display | 2-line × 16-character LCD |
| Power Supply | 230 V, 50–60 Hz |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ES14 |
| Price | Upon Request |
| Temperature Range | 100–950 °C |
| Temperature Accuracy | ±10 °C |
| Thermocouple Type | Type K (max. 1200 °C), Type N (max. 1300 °C) |
| Furnace Tube Material | Fused quartz (Ø25 × 500 mm ID) |
| Reaction Vessel Material | Borosilicate glass |
| Furnace Housing & Structural Plate | Stainless steel (AISI 304) |
| Air Flow Control Range | 0.1–2.0 L/min (adjustable via needle valve and rotameter, calibrated 60–600 cm³/min) |
| Over-Temperature Protection | Independent dual-stage cutoff controller |
| Power Supply | 230 V AC, 50 Hz, 500 W |
| Net Weight | 22 kg |
| External Dimensions (W×D×H) | 1350 × 275 × 355 mm |
| Origin | United Kingdom |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ES-80 |
| Price | Upon Request |
| Oscillation Speed | 50–250 rpm |
| Orbit Diameter | 20 mm |
| Temperature Set Range | 25–80 °C |
| Temperature Control Range | Ambient +5 to 80 °C |
| Temperature Setting Resolution | 0.1 °C |
| Max Load Capacity | 8 kg |
| Timer Range | 1 min – 96 h |
| Continuous Operation | Up to 168 h |
| Display | 2-line × 16-character LCD |
| Internal Height | 270 mm |
| External Dimensions (W×L×H) | 590 × 525 × 510 mm |
| Net Weight | 43 kg |
| Power Supply | 230 V, 50–60 Hz |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Pricing | Available Upon Request |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ET-1151M |
| Price Range | USD 1,400–2,800 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Wavelengths | 420 nm, 610 nm |
| COD Range (Standard Method) | 15–150 mg/L |
| COD Range (Rapid Method) | 100–1,000 mg/L |
| TN Range | 0–150 mg/L |
| TP Range | 0.05–20 mg/L |
| NH₃-N Range | 0.10–60.0 mg/L |
| Accuracy | ±8% |
| Repeatability | RSD ≤3% |
| LOD (COD) | 0.1 mg/L |
| Measurement Time (Rapid COD) | 20 min total (incl. digestion & photometry) |
| Batch Capacity | 1 or 20 samples per run |
| Light Source | High-Stability LED |
| Wavelength Accuracy | ±2 nm |
| Photometric Stability | ΔA < 0.005 in 20 min |
| Display Modes | Absorbance, Transmittance, Concentration |
| Auto-Wavelength Selection | Yes |
| Power Supply | 220 V AC, 50 Hz |
| Operating Temp. | 5–50 °C |
| Relative Humidity | 20–85% RH |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | ET1020A |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET1200 |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Infrared Absorption Spectrophotometry (Triple-Wavelength Method at 3030 cm⁻¹, 2960 cm⁻¹, 2930 cm⁻¹) |
| Measurement Range | 0–1000 mg/L (as oil in water) |
| Detection Limit | 0.2 mg/L (in CCl₄ extract) |
| Accuracy | ±5% of reading |
| Resolution | 0.1 ppm |
| Measurement Frequency | 10 measurements per minute |
| Wavenumber Range | 3400–2400 cm⁻¹ |
| Wavenumber Accuracy | ±2 cm⁻¹ |
| Repeatability | RSD < 3% |
| Output Interface | RS-232 |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 500 × 380 × 220 mm |
| Weight | 15 kg |
| Operating Temperature | 5–35 °C |
| Compliance | GB/T 16488–1996 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET1200 |
| Price Range | USD 1,400–7,200 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Infrared Absorption Spectrophotometry (Triple-Wavelength IR at 3030 cm⁻¹, 2960 cm⁻¹, 2930 cm⁻¹) |
| Measurement Range | 0–1000 mg/L (as oil in water) |
| Detection Limit | 0.2 mg/L (in C₂Cl₄ extract) |
| Accuracy | ±0.4 mg/L (C < 10 mg/L) |
| Repeatability | RSD < 3% (typical) |
| Resolution | 0.2 mg/L (in tetrachloroethylene matrix) |
| Wavenumber Range | 3400–2400 cm⁻¹ |
| Wavenumber Accuracy | ±2 cm⁻¹ |
| Measurement Cycle Time | ≤25 s per sample |
| Operating Temperature | 5–35 °C |
| Power Supply | 220 V ±10%, 50 Hz |
| Dimensions | 500 × 380 × 220 mm |
| Weight | 15 kg |
| Data Interface | RS-232 serial port |
| Compliance | GB/T 16488–1996 (China National Standard for Petroleum & Animal/Vegetable Oil in Water) |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ET1500 |
| Price | Upon Request |
| Dynamic Range | ≥10⁶ |
| Sample Tube Dimensions | Ø12 mm, Height 47–75 mm |
| Communication Interface | RS232C |
| Measurement Duration | 0–99 s (1 s increments) |
| Data Storage Capacity | ≥2000 test records |
| Operating Temperature | 15–40 °C |
| Display | Backlit LCD |
| Power Supply | 220 V ±10 %, 50 Hz, 35 W |
| Rechargeable Battery | 3.7 V, 5000 mAh |
| Operating Humidity | 10–90 % RH (non-condensing) |
| Dimensions (L×W×H) | 320 × 170 × 180 mm |
| Weight | 2 kg (including battery) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | ET3150B/ET1150M |
| Instrument Type | Benchtop Laboratory Analyzer |
| Power Supply | 220 V AC, 50 Hz |
| Operating Temperature | 5–50 °C |
| Relative Humidity | 20–85 % RH |
| Wavelength Accuracy | ±2 nm |
| Wavelength Selection | 420 nm and 610 nm (LED-based optical system) |
| Photometric Accuracy | ±8 % of full scale |
| Repeatability | RSD ≤ 3 % |
| Photometric Stability | ΔA < 0.005 A within 20 min |
| Measurement Modes | Absorbance, Transmittance, Concentration |
| Built-in Test Programs | COD, TN, TP, NH₃-N, F⁻ |
| Preloaded Calibration Curves | 6 |
| User-defined Curve Storage | Supported |
| ET3150B Digestion Block Capacity | 24 × Φ16 × 100 mm tubes |
| Digestion Temperature Accuracy | ±1 °C |
| COD Digestion Temp | 165 °C ±1 °C |
| TN/TP Digestion Temp | 105 °C |
| Timer Range | 1–1860 min (31 h) |
| Display | LCD with full Chinese interface |
| Heating Rate | 20 → 165 °C in ≤10 min |
| Safety Features | Auto-shutdown, over-temperature alarm, timer alert |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET5101 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Compliant Portable Analyzer |
| Indication Error | ±0.2% FS |
| Repeatability | <2% RSD |
| Response Time | ≤15 s (T90) |
| Stability | <5% drift over 8 h |
| Measured Parameters | Particulate Matter (PM) concentration via gravimetric filtration + Flue Gas composition (O₂, SO₂, NO, NO₂, CO, CO₂) |
| Origin | Japan |
|---|---|
| Type | Upright Vertical Chamber |
| Application-Specific Configurations | PV Module Testing, Secondary Battery Safety Testing, Laminated Glass Testing per JIS Standards |
| Compliance | Designed for ASTM D4332, ISO 6270-2, IEC 61215-2, UL 1642, JIS R 3212 & JIS A 5759 |
| Control Precision | ±0.5 °C temperature uniformity, ±2 % RH stability (at 25 °C / 60 % RH steady state) |
| Airflow System | High-static-pressure axial fan with laminar flow distribution |
| Safety Systems | Pressure-relief venting, optical smoke detection, halocarbon-based automatic fire suppression (FM-200® compatible), forced exhaust interlock |
| Viewing Window | Triple-layer tempered safety glass with anti-fog heating element |
| Data Logging | Integrated real-time logging with audit trail and exportable CSV/TXT files |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ETCU Series Environmental Test Chambers |
| Pricing | Available Upon Request |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ETD-300 (system platform) |
| Detection Limit | 0.3 ppbv |
| Measurement Range | 0–5 ppmv |
| Response Time | 30 s (at 1 L/h flow) |
| Measurement Interval | 5 s |
| Zero Drift | ±1 ppbv |
| Accuracy | <1% FS or ±0.3 ppbv |
| Stability | <1% over 24 h |
| Flow Rate | 0.25–5 L/h (ETD-300 & VC-6) |
| Channel Capacity | 6 samples (expandable to 12/18 via additional VC-6 units) |
| Calibration | Certified gas mixture, annual recalibration recommended |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ETN9310 |
| Pricing | Available Upon Request |
| Instrument Type | Portable Water Sampler |
| Bottle Sampler Capacity | 1 L, 3 L |
| Rope Length | 20 m |
| Handheld Sampler Capacity | 0.5 L, 1 L |
| Telescopic Handle Length | 70–150 cm |
| Origin | Czech Republic |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ETran |
| Pricing | Upon Request |
| Origin | Belgium |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CD1200PLC |
| Power | 5 kW |
| Chamber Dimensions | 700 × 700 × 1200 mm |
| Chamber Volume | 490 L |
| Chamber Material | Anodized Aluminum |
| Process Gases | O₂, Ar, N₂, or gas mixtures |
| Control System | Fully Automated PLC-Based Interface |
| Instrument Type | Imported Industrial-Grade Low-Pressure RF Plasma System |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Eutech CON2700 |
| Price | Upon Request |
| Measured Parameter | Conductivity (Single-Parameter) |
| Form Factor | Benchtop |
| Conductivity Range | 0.050 μS/cm to 500.0 mS/cm |
| TDS Range | 0.050 ppm to 500 ppt (at TDS factor = 1.00) |
| Resistivity Range | 2.000 Ω to 20.0 MΩ |
| Salinity Range | 0–80 ppt |
| Temperature Range | 0.0–100.0 °C |
| Accuracy | ±1% of full scale |
| Minimum Resolution | 0.01 / 0.1 μS/cm |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PCD650 |
| Pricing | Upon Request |
| Instrument Type | Laboratory-Grade Portable Water Quality Analyzer |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TB 1000 |
| Product Type | Portable |
| Measurement Range | 0.00–9.99 NTU |
| Resolution | 0.01 NTU (0–9.99 NTU) |
| Operating Temperature | 0–40 °C |
| Accuracy | ±2% of reading |
| Repeatability | ≤±1% of reading |
| Response Time | <6 s |
| Sample Volume | 30 mL |
| Light Source | Tungsten lamp (white light), compliant with US EPA Method 180.1 |
| Calibration | 1–3-point automatic calibration (standard points: 0.02, 10.0, 1000 NTU) |
| Calibration Accuracy | ±0.02 NTU at 0.02 NTU point |
| Data Output | RS232C interface |
| GLP Compliance | Date/time stamping, calibration expiry alerts, audit-ready data logging |
| Enclosure | ABS plastic housing |
| Power Supply | UL/CSA-certified 12 VDC regulated adapter |
| Dimensions (instrument) | 25.4 × 23.7 × 12.1 cm |
| Weight (instrument) | 1550 g |
| Packaging Dimensions | 35.5 × 31.5 × 25 cm |
| Gross Weight | 2380 g |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech DO2700 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| Range Accuracy | ±0.5% of full scale |
| Resolution (DO) | 0.01 mg/L |
| Saturation Range | 0–600% |
| Temperature Range | 0.0–50.0 °C |
| Temp. Accuracy | ±0.3 °C |
| Salinity Compensation | 0–50 ppt |
| Barometric Pressure Compensation | 450–825 mmHg (auto) |
| Data Storage | 500 GLP-compliant records with timestamp |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Interface | RS232 (bidirectional), 8-pin probe connector, DC socket |
| Power | 9 V regulated adapter (100–240 VAC SMPS) |
| Dimensions (unit) | 17.5 × 15.5 × 6.9 cm |
| Weight (unit) | 650 g |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech Ion2700 |
| Instrument Type | Multi-Ion Analyzer |
| pH Range | –2.000 to 20.000 |
| pH Resolution | 0.1 / 0.01 / 0.001 |
| pH Accuracy | ±0.002 pH + 1 LSD |
| pH Calibration Points | Up to 6 |
| Buffer Standards | USA, NIST, DIN, User 1, User 2, Custom |
| Ion Concentration Range | 0.001–19999 ppm (±2000.0 mV) |
| Ion Resolution | 2- or 3-digit |
| Ion Accuracy | ±0.5% of full scale (monovalent), ±1.0% of full scale (divalent) |
| Ion Calibration Points | 2–8 |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| ORP/mV Range | ±2000.0 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.2 mV |
| Temperature Compensation | Automatic or Manual (0–100 °C, pH only) |
| GLP Compliance | Yes |
| Slope/Offset Display | Yes |
| Data Storage | 500 records with timestamp |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Input Interfaces | BNC (pH/ORP/ion), Phono (ATC probe), Phono (reference electrode), DC socket |
| Output Interface | RS232C |
| Power Supply | 9 V DC regulated adapter (100–240 VAC SMPS, 1.3 A) |
| Operating Temperature | 5–45 °C |
| Dimensions (H×W×D) | 17.5 × 15.5 × 6.9 cm |
| Weight (unit) | 650 g |
| Packaging Dimensions | 30.8 × 23.5 × 12.4 cm |
| Shipping Weight | 1800 g |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech Ion700 |
| Pricing | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech PH2700 |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH + ORP) |
| pH Measurement Range | -2.000 to 20.000 pH |
| pH Resolution | 0.1 / 0.01 / 0.001 pH |
| pH Accuracy | ±0.002 pH + 1 LSD |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.3 °C |
| ORP/mV Range | ±2000.0 mV |
| ORP/mV Resolution | 0.1 mV |
| ORP/mV Accuracy | ±0.2 mV |
| Calibration Points | Up to 6-point, auto-buffer recognition (USA, NIST, DIN, User 1, User 2, Custom) |
| Electrode Diagnostics | Slope & Offset Display |
| Data Storage | 500 GLP-compliant entries with timestamp |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Display | Backlit LCD (5.9 × 7.8 cm) |
| Connectivity | BNC (pH/ORP), Phono (ATC probe), Phono (Reference), RS232C output |
| Power | 9 V DC regulated adapter (100–240 VAC SMPS) |
| Dimensions (W×D×H) | 17.5 × 15.5 × 6.9 cm |
| Weight | 650 g (unit only) |
| Origin | Singapore |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Eutech pH700 |
| Instrument Type | Benchtop |
| Parameter Channels | Dual (pH + ORP) |
| pH Range | -2.00 to 16.00 pH |
| pH Resolution | 0.01 pH |
| pH Accuracy | ±0.01 pH + 1 LSD |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| ORP/mV Range | ±2000 mV |
| ORP Resolution | 0.1 mV (within ±199.9 mV), 1 mV (elsewhere) |
| ORP Accuracy | 0.1 mV (within ±199.9 mV), 1 mV (elsewhere) |
| Calibration Points | Up to 5-point pH calibration |
| Buffer Standards | USA and NIST traceable |
| Temperature Compensation | Automatic or Manual (0–100 °C, pH only) |
| Data Storage | 100 measurement records |
| GLP Compliance | Yes (slope/offset display, timestamped calibration logs) |
| Display | Dual-line LCD (5.6 × 7.5 cm) |
| Input Interfaces | BNC (pH/ORP), Phono (ATC probe), Phono (reference electrode), DC socket |
| Power Supply | 9 V DC regulated adapter (100–240 VAC SMPS) |
| Dimensions (W×D×H) | 17.5 × 15.5 × 6.9 cm |
| Weight | 650 g (instrument only) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EV Series |
| Pricing | Available Upon Request |
| Heating Temperature Range | Ambient to 350 °C |
|---|---|
| Heater Type | Cartridge Heater |
| Max. Sample Volume | <10 mL |
| Carrier Gas | Nitrogen or Dry Air (dry air compressor optional) |
| Gas Flow Rate | 30–300 L/min |
| Inlet Pressure | ≤0.8 MPa |
| Desiccant | Molecular Sieve |
| Power Supply | AC 100–240 V, 50/60 Hz, 100 VA |
| Dimensions (W×D×H) | 220 × 430 × 200 mm |
| Weight | Approx. 8 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | EV-2000L |
| Pricing | Available Upon Request |
| Moisture Evaporation Method | Azeotropic Distillation with Inert Carrier Gas |
| Heating Range | Ambient to 200 °C |
| Heater Type | Band Heater |
| Max Sample Volume | ≤10 mL |
| Azeotropic Solvent | Toluene or Xylene (5–10 mL per analysis) |
| Carrier Gas | Nitrogen or Dry Compressed Air (optional integrated air dryer/pump available) |
| Gas Flow Rate | 30–300 L/min |
| Inlet Pressure | ≤0.8 MPa |
| Desiccant | Molecular Sieve (4 Å) |
| Power Supply | AC 100–240 V, 50/60 Hz, 150 VA |
| Dimensions (W×D×H) | 220 × 370 × 265 mm |
| Net Weight | ~7 kg |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EX-TE |
| Pricing | Available Upon Request |
| Vessel Capacities | 3 L, 5 L, 10 L, 30 L, 50 L, 100 L |
| Heating Power | 3–15 kW |
| Agitation Power | 0.09–0.5 kW |
| Design Pressure (Inner Vessel) | 0.09 MPa |
| Design Pressure (Jacket) | 0.3–0.4 MPa |
| Temperature Control | Dual-point (Extraction & Jacket) |
| Safety Features | Low-level liquid protection, real-time temperature monitoring |
| Optional Ultrasound Module | Frequency range 15–60 kHz (focused transducer array, frame-type agitator integration) |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | EX-TE-03 / EX-TE-05 / EX-TE-10 / EX-TE-30 / EX-TE-50 / EX-TE-100 |
| Capacity | 3–100 L |
| Design Pressure (Vessel) | 0.09 MPa |
| Design Pressure (Jacket) | 0.3–0.4 MPa |
| Heating Power | 3–15 kW |
| Stirring Power | 0.09–0.5 kW |
| Temperature Control | Integrated PID with Digital Display |
| Optional Ultrasonic Frequency Range | 15–60 kHz |
| Safety Features | Low-Level Liquid Protection, Dual-Temperature Monitoring, Expandable Multi-Unit Synchronization |