GreenPrima
Filter
Showing 361–390 of 480 results
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON5000 |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PROCON6000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Photometric Colorimetry (Molybdenum Blue Method) |
| Detection Range | 0–200 µg/L SiO₂ (configurable sub-ranges available) |
| Accuracy | ±2% of reading or ±1 µg/L (whichever is greater) |
| Repeatability | <1.5% RSD |
| Sample Temperature Range | 5–40 °C |
| Sample Pressure | 0.1–0.6 bar |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | IP65 |
| Communication Interfaces | RS485 (Modbus RTU), 0/4–20 mA (programmable), USB (optional data export) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON6000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Photometric Detection of Reduced β-Molybdo-Silicic Acid Complex |
| Measuring Range | 1–100 ppb |
| Resolution | 0.1 ppb |
| Accuracy | ±2% of full scale |
| Repeatability | ±0.5 ppb |
| Zero Stability | Auto-zero compensation |
| Dimensions (H×W×D) | 640 × 315 × 190 mm |
| Display | 240 × 128 pixel monochrome touchscreen |
| Output | 0/4–20 mA (max. load 500 Ω) |
| Cycle Time | 13 min (including rinse) |
| Operating Temperature | 5–45 °C |
| Power Supply | 110–230 V AC, 50/60 Hz |
| Electrical Interface | 1.5 mm² ring terminals |
| Relay Outputs | 1 alarm (dry contact, 230 V AC / 3 A), 1 limit (dry contact, 230 V AC / 3 A), 1 analysis cycle (dry contact, 230 V AC / 3 A), 1 remote start/stop (dry contact, 18 V DC / ~4 mA) |
| Enclosure Rating | IP65 |
| Power Consumption | ~16 VA |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON6000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Photometric Determination of Soluble Silica via Molybdenum Blue Reduction Method |
| Measurement Ranges | 1–100 ppb, 4–999 ppb, 0.02–3 ppm SiO₂ |
| Resolution | 0.1 ppb / 1 ppb / 0.01 ppm |
| Accuracy | ±2% of full scale |
| Repeatability | ±0.5 ppb / ±4 ppb / ±0.02 ppm |
| Zero Stability | Auto-zero compensation |
| Analysis Cycle | 13 min (standard), adjustable from 1–99 min or externally triggered |
| Dimensions (H×W×D) | 640 × 315 × 190 mm |
| Display | 240 × 128 pixel monochrome touchscreen |
| Analog Output | 0/4–20 mA (max. load 500 Ω) |
| Digital Interface | USB data logging (optional) |
| Relay Outputs | 3× SPDT zero-potential relays (alarm, limit, analysis), rated 230 V AC / 3 A |
| Environmental Operating Range | 5–45 °C |
| Power Supply | 110–230 V AC, 50/60 Hz |
| Enclosure Rating | IP65 |
| Power Consumption | ~16 VA |
| [Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Product Type | Online Analyzer |
| Model | PROCON6000 |
| Measurement Principle | Photometric detection of reduced β-molybdo-silicic acid complex |
| Range Options | 1–100 ppb, 4–999 ppb, 0.02–3 ppm SiO₂ |
| Resolution | 0.1 ppb / 1 ppb / 0.01 ppm |
| Accuracy | ±2% of full scale |
| Repeatability | ±0.5 ppb / ±4 ppb / ±0.02 ppm |
| Zero Stability | Automatic zero drift compensation |
| Cycle Time | 13 min (standard), adjustable 1–99 min or externally triggered |
| Display | 240×128 pixel touchscreen |
| Output | 0/4–20 mA (max. 500 Ω load) |
| Relay Outputs | 3 × SPDT, dry contact, 230 V AC / 3 A |
| Remote Control Input | Dry contact, 18 V DC, ~4 mA |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 640×315×190 mm |
| Operating Temperature | 5–45 °C |
| Power Supply | 110–230 V AC, 50/60 Hz |
| Power Consumption | ~16 VA |
| Compliance | Designed for ISO/IEC 17025-aligned operation |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON7000 |
| Instrument Type | Online |
| Measurement Principle | Fluorescence-based optical detection (non-extractive, in-situ) |
| Measurement Range | 0–99 ppm |
| Accuracy | ±2 ppm |
| Alarm Setpoint Range | 1–98 ppm (adjustable) |
| Alarm 1 Delay | 0–60 s (adjustable) |
| Alarm 2 Delay | 10–240 s (adjustable) |
| Display | 240 × 128 pixel touchscreen |
| Analog Outputs | 0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ) |
| Sample Temp. | 1–40 °C |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Pressure | 0.1–10 bar |
| Ambient Temp. | 1–60 °C |
| Humidity | ≤90% RH at 55 °C |
| Enclosure Rating | IP55 |
| Electrical Safety | EN 61010-1 / IEC 61000-4 (Overvoltage Category II) |
| Weight | 2.25 kg |
| Dimensions (H×W×D) | 215 × 242 × 73 mm |
| Power Supply | 230 V / 115 V AC or 24 V AC |
| Max. Power Consumption | 10 VA |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON7000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Infrared Spectrophotometry (IR) |
| Measurement Range | 1–99 ppm |
| Detection Limit | 1 ppm |
| Accuracy | ±2 ppm |
| Resolution | 1 ppm |
| Measurement Frequency | Real-time |
| Display | 240 × 128 pixel touchscreen |
| Output Signals | 0–20 mA, 4–20 mA (min. load 820 Ω), 0–5 V DC, 1–5 V DC (min. load 50 kΩ) |
| Ambient Temperature Range | 1–60 °C |
| Relative Humidity | ≤90 % RH at 55 °C |
| Sample Temperature Range | 1–40 °C |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Pressure Range | 0.1–10 bar |
| Weight | 2.25 kg |
| Dimensions (W × H × D) | 215 × 242 × 73 mm |
| Power Supply | 230 V / 115 V AC or 24 V AC |
| Max. Power Consumption | 10 VA |
| Enclosure Rating | IP55 |
| Electrical Safety Compliance | EN 61010-1 / IEC 61000-4 (Overvoltage Category II) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON7000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Fluorescence-based Optical Detection (Non-Extractive, Solvent-Free) |
| Measurement Range | 0–99 ppm |
| Accuracy | ±2 ppm |
| Alarm Setpoint Range | 1–98 ppm (adjustable) |
| Alarm Delay | Alarm 1: 0–60 s |
| Alarm 2 | 10–240 s (both adjustable) |
| Display | 240 × 128 pixel TFT touchscreen |
| Output Signals | 0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ) |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Temperature | 1–40 °C |
| Sample Pressure | 0.1–10 bar |
| Ambient Operating Temperature | 1–60 °C |
| Relative Humidity | ≤90% RH at 55 °C |
| Enclosure Rating | IP55 |
| Electrical Safety | EN 61010-1 / IEC 61000-6-2 & -6-3, Overvoltage Category II |
| Power Supply | 230 V / 115 V AC or 24 V AC, Max. 10 VA |
| Weight | 2.25 kg |
| Dimensions (H×W×D) | 215 × 242 × 73 mm |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON7000 |
| Instrument Type | Online |
| Measurement Principle | Fluorescence-based Optical Detection |
| Measurement Range | 0–99 ppm |
| Accuracy | ±2 ppm |
| Alarm Setpoint Range | 1–98 ppm (adjustable) |
| Alarm Delay 1 | 0–60 s (adjustable) |
| Alarm Delay 2 | 10–240 s (adjustable) |
| Display | 240×128 pixel touchscreen |
| Output Signals | 0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ) |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Temperature | 1–40 °C |
| Sample Pressure | 0.1–10 bar |
| Ambient Operating Temperature | 1–60 °C |
| Relative Humidity | ≤90% RH at 55 °C |
| Enclosure Rating | IP55 |
| Electrical Safety | EN 61010-1 / IEC 61000-4 (Overvoltage Category II) |
| Power Supply | 230 V / 115 V AC or 24 V AC |
| Max. Power Consumption | 10 VA |
| Dimensions (H×W×D) | 215 × 242 × 73 mm |
| Weight | 2.25 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON7000 |
| Instrument Type | Online |
| Measurement Principle | Fluorescence-based Optical Detection (Non-Extractive, Solvent-Free) |
| Measurement Range | 0–99 ppm |
| Accuracy | ±2 ppm |
| Alarm Setpoint Range | 1–98 ppm (Adjustable) |
| Alarm Delay 1 | 0–60 s (Adjustable) |
| Alarm Delay 2 | 10–240 s (Adjustable) |
| Display | 240×128 Pixel Touchscreen |
| Output Signals | 0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ) |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Temperature | 1–40 °C |
| Sample Pressure | 0.1–10 bar |
| Ambient Operating Temperature | 1–60 °C |
| Relative Humidity | ≤90% RH at 55 °C |
| Enclosure Rating | IP55 |
| Electrical Safety | EN 61010-1 / IEC 61010-1, Overvoltage Category II |
| Power Supply | 230 V / 115 V AC or 24 V AC |
| Max. Power Consumption | 10 VA |
| Weight | 2.25 kg |
| Dimensions (H×W×D) | 215 × 242 × 73 mm |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON7000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Fluorescence-based Optical Detection (Non-Extractive, Solvent-Free) |
| Measurement Range | 0–99 ppm |
| Accuracy | ±2 ppm |
| Alarm Setpoint Range | 1–98 ppm (adjustable) |
| Alarm Delay | Alarm 1: 0–60 s |
| Alarm 2 | 10–240 s (both adjustable) |
| Display | 240 × 128 pixel resistive touchscreen |
| Analog Outputs | 0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ) |
| Environmental Operating Temperature | 1–60 °C |
| Relative Humidity | ≤90% RH at 55 °C |
| Sample Temperature | 1–40 °C |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Pressure | 0.1–10 bar |
| Weight | 2.25 kg |
| Dimensions (H×W×D) | 215 × 242 × 73 mm |
| Power Supply | 230 V / 115 V AC or 24 V AC |
| Max. Power Consumption | 10 VA |
| Enclosure Rating | IP55 |
| Electrical Safety | Complies with EN 61010-1 and IEC 61000-6-2/6-4 (Overvoltage Category II) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON7000 |
| Instrument Type | Online |
| Measurement Principle | Fluorescence-based Optical Detection (Non-Extractive) |
| Measurement Range | 0–99 ppm |
| Accuracy | ±2 ppm |
| Alarm Setpoint Range | 1–98 ppm (adjustable) |
| Alarm Delay | Alarm 1: 0–60 s |
| Alarm 2 | 10–240 s (both adjustable) |
| Display | 240 × 128 pixel resistive touchscreen |
| Analog Outputs | 0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ) |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Temperature | 1–40 °C |
| Sample Pressure | 0.1–10 bar |
| Ambient Operating Temperature | 1–60 °C |
| Relative Humidity | ≤90% RH at 55 °C |
| Enclosure Rating | IP55 |
| Electrical Safety | EN 61010-1, IEC 664 Category II |
| Power Supply | 230 V / 115 V AC or 24 V AC |
| Max. Power Consumption | 10 VA |
| Dimensions (H×W×D) | 215 × 242 × 73 mm |
| Weight | 2.25 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROCON7000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Fluorescence-based Optical Detection (Non-Extractive, Solvent-Free) |
| Measurement Range | 0–99 ppm |
| Accuracy | ±2 ppm |
| Alarm Setpoint Range | 1–98 ppm (adjustable) |
| Alarm Delay | Alarm 1: 0–60 s |
| Alarm 2 | 10–240 s (both adjustable) |
| Display | 240 × 128 pixel resistive touchscreen |
| Analog Outputs | 0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ) |
| Environmental Operating Temperature | 1–60 °C |
| Relative Humidity | ≤90% RH at 55 °C |
| Sample Temperature Range | 1–40 °C |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Pressure | 0.1–10 bar |
| Weight | 2.25 kg |
| Dimensions (H×W×D) | 215 × 242 × 73 mm |
| Power Supply | 230 V / 115 V AC or 24 V AC |
| Max. Power Consumption | 10 VA |
| Enclosure Rating | IP55 |
| Electrical Safety | Compliant with EN 61010-1 and IEC 664 Category II |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON7000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Fluorescence-based Optical Detection (Non-Extractive, Solvent-Free) |
| Measurement Range | 0–99 ppm |
| Accuracy | ±2 ppm |
| Alarm Setpoint Range | 1–98 ppm (adjustable) |
| Alarm Delay | Alarm 1: 0–60 s |
| Alarm 2 | 10–240 s (both adjustable) |
| Display | 240 × 128 pixel resistive touchscreen |
| Analog Outputs | 0/4–20 mA (min. load 820 Ω), 0–5 V / 1–5 V DC (min. load 50 kΩ) |
| Sample Flow Rate | 0.1–2 L/min |
| Sample Temperature | 1–40 °C |
| Sample Pressure | 0.1–10 bar |
| Ambient Operating Temperature | 1–60 °C |
| Relative Humidity | ≤90% RH at 55 °C |
| Enclosure Rating | IP55 |
| Electrical Safety | EN 61010-1 / IEC 61010-1, Overvoltage Category II |
| Power Supply | 230 V AC / 115 V AC or 24 V AC, max. 10 VA |
| Weight | 2.25 kg |
| Dimensions (H×W×D) | 215 × 242 × 73 mm |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON8000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Output Signals | 4–20 mA, RS485 |
| Measurement Principle | Automated Potentiometric Titration with Colorimetric Endpoint Detection |
| Reagent Consumption | Low |
| Enclosure Rating | IP65 |
| Wetted Materials | PTFE, PVDF, EPDM, Borosilicate Glass |
| Operating Mode | Continuous or Interval Measurement |
| Display | 7-inch TFT Touchscreen with Multilingual UI (English/Chinese) |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Imported |
| Model | PROCON 8000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Calcium and Magnesium Hardness (as CaCO₃) |
| Detection Principle | Automated Potentiometric Titration with Colorimetric Endpoint Detection |
| Output Signals | 4–20 mA analog output, RS485 Modbus RTU |
| Measurement Mode | Continuous or Programmable Interval Sampling |
| Enclosure Rating | IP65 |
| Wetted Materials | PTFE, PVDF, Borosilicate Glass, EPDM |
| Reagent Consumption | ≤1.2 mL per measurement cycle |
| Power Supply | 230 VAC ±10%, 50/60 Hz |
| Operating Temperature | 5–45 °C |
| Storage Temperature | –20–60 °C |
| Dimensions (W×H×D) | 400 × 500 × 220 mm |
| Weight | 18 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | PROL E V200 |
| Product Type | Ultrasonic Level Transmitter |
| Measurement Principle | Non-contact ultrasonic time-of-flight (ToF) |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Display | LCD with 1 mm resolution |
| Accuracy | ±0.2% FS |
| Measuring Range | 6 m / 10 m (configurable) |
| Blind Zone | 0.25 m / 0.5 m |
| Operating Temperature | –30 to +70 °C |
| Maximum Process Pressure | 1.5 bar |
| Housing Material | PC/PP |
| Sensor Material | ETFE or PVDF |
| Ingress Protection | IP67 |
| Electrical Interface | G2" |
| Media Compatibility | Liquids and bulk solids |
| Environmental Compliance | ATEX II 1/2G Ex ia II C T6 (optional variant) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProL e v800 |
| Measurement Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent transducers |
| Accuracy | ±1 cm |
| Response Time | 1 s |
| Operating Temperature | −20 °C to +60 °C |
| Display | Large-backlit LCD with graphical interface (numeric readout, trend plot, echo waveform) |
| Output | 4–20 mA analog signal |
| Alarms | Dual programmable Hi/Low relay outputs |
| Communication | RS232C (cable length ≤10 m) |
| Power Supply | 85–264 VAC, 10 VA |
| Ingress Protection | IP68 |
| Cable Length | 20 m |
| Weight | 3.6 kg (transmitter), 3.0 kg (per transducer) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | PROL EV200 |
| Product Type | Ultrasonic Level Transmitter |
| Measurement Principle | Non-contact ultrasonic time-of-flight (ToF) |
| Max. Range | 10 m |
| Blind Zone | 0.5 m |
| Accuracy | ±0.2% FS |
| Display | Backlit LCD |
| Resolution | 1 mm |
| Operating Temperature | −30 to +70 °C |
| Enclosure Material | PC/PP |
| Sensor Material | ETFE or PVDF |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Power Supply | 24 VDC |
| Ingress Protection | IP67 |
| Explosion Protection | ATEX II 1/2G Ex ia II C T6 |
| Process Connection | G2" |
| Maximum Process Pressure | 1.5 bar |
| Application Scope | Liquids and bulk solids in industrial process control |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROL EV200 |
| Product Type | Ultrasonic Level Transmitter |
| Measuring Range | 6 m / 10 m |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% FS |
| Display | LCD |
| Resolution | 1 mm |
| Max. Process Pressure | 1.5 bar |
| Operating Temperature | −30 to +70 °C |
| Housing Material | PC/PP |
| Sensor Material | ETFE or PVDF |
| Output | 2-wire 4–20 mA (max. 750 Ω) |
| Power Supply | 24 VDC |
| Protection Rating | IP67 |
| Explosion Protection | None |
| Process Connection | G2" |
| Media Compatibility | Liquids and solids |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Level Meter |
| Model | PROL EV200 / PROL EV300 |
| Measurement Principle | Non-contact ultrasonic time-of-flight (ToF) |
| Range | 6 m / 10 m (selectable per variant) |
| Blind Zone | 0.25 m / 0.5 m |
| Accuracy | ±0.2% FS |
| Resolution | 1 mm |
| Max Process Pressure | 1.5 bar |
| Operating Temperature | −30 to +70 °C |
| Housing Material | PC/PP (EV200), Aluminum/PVDF (EV300) |
| Sensor Diaphragm Material | ETFE or PVDF |
| Output Options | 2-wire 4–20 mA (max 750 Ω), 4-wire 4–20 mA + Modbus RTU + dual relay, or 2-wire HART-enabled variants |
| Power Supply | 24 VDC |
| Ingress Protection | IP67 (EV200), IP68 (EV300) |
| Explosion Protection | ATEX II 1/2G Ex ia II C T6 |
| Process Connection | G2" |
| Media Compatibility | Liquids and bulk solids |
| Display | Backlit LCD |
| Brand | GreenPrima |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | ProL ev800 |
| Price Range | USD 2,800 – 7,000 |
| Measurement Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent probes |
| Accuracy | ±1 cm |
| Response Time | 1 s |
| Operating Ambient Temperature | −20 to +60 °C |
| Display | Large LCD with digital readout, trend graph, and real-time echo waveform |
| Enclosure Rating | IP68 |
| Weight | 3.6 kg (transmitter), 3 kg (probe) |
| Output | 4–20 mA analog output |
| Alarms | Dual programmable high/low level relays |
| Communication | RS-232C (≤10 m cable length) |
| Power Supply | 85–264 VAC, 10 VA |
| Cable Length | 20 m |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProLe v600 |
| Pricing | Available Upon Request |
| Measurement Principle | Non-contact ultrasonic level sensing with hydraulic algorithm-based flow calculation |
| Range | 5 m |
| Resolution | 1 mm |
| Blind Zone | 0.25 m |
| Accuracy | ±0.2% of Full Scale |
| Output Signals | 4–20 mA analog output, RS485 serial interface (Modbus RTU protocol) |
| Power Supply | 24 VDC |
| Operating Temperature | –30 to +70 °C |
| Maximum Pressure Rating | 1.0 bar |
| Process Connection | G2" (ISO 228-1) |
| Housing Material | Polycarbonate (PC) / Polypropylene (PP) blend |
| Ingress Protection | IP67 |
| Dimensions (L×W×H) | 138 × 246 × 134 mm |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROLEV 500D |
| Product Type | Level Meter |
| Controller Housing Material | ABS |
| Display | 320×240 matrix color LCD with backlight |
| Operating Temperature (Controller) | −20 to +60.0 °C |
| Output | 2 × 4–20 mA + Modbus RTU (RS-485) + 2 relays |
| Output Variant | 2 × 4–20 mA + Modbus RTU (RS-485) + 5 relays |
| Power Supply | 85–230 V AC or 24 V DC |
| Enclosure Rating (Controller) | IP66 |
| Mounting | Wall, pipe, or DIN rail |
| Dimensions (Controller) | 184 × 223 × 130 mm |
| Sensor Model | PSU06 / PSU12 |
| Measuring Range | 0.3–6 m / 0.5–12 m |
| Accuracy | ±0.2 % FS |
| Resolution | 1 mm |
| Max. Process Pressure | 1.0 bar |
| Operating Temperature (Sensor) | −30 to +70.0 °C |
| Sensor Housing Material | PC/PP |
| Cable Length | 10 m |
| Sensor IP Rating | IP68 |
| Process Connection | G1" |
| Sensor Diaphragm Material | ETFE or PVDF |
| Application Scope | Solids and liquids |
| Brand | GreenPrima |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROLEV 800 |
| Measurement Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent ultrasonic transducers |
| Accuracy | ±1 cm |
| Response Time | 1 s |
| Operating Temperature | −20 to +60 °C |
| Display | Large-backlit LCD with graphical interface (level profile, echo waveform, trend plot) |
| Protection Rating | IP68 |
| Weight | 3.6 kg (transmitter), 3.0 kg (per probe) |
| Output | 4–20 mA analog output |
| Alarms | Dual programmable high/low level relay outputs |
| Communication | RS-232C (cable length ≤10 m) |
| Power Supply | 85–264 VAC, 10 VA |
| Cable Length | 20 m |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProLev 800 |
| Measurement Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent ultrasonic transducers |
| Accuracy | ±1 cm |
| Response Time | 1 s |
| Operating Ambient Temperature | −20 to +60 °C |
| Display | Large-backlit LCD with graphical interface (numeric readout, trend plot, echo waveform) |
| Enclosure Rating | IP68 |
| Weight | 3.6 kg (transmitter), 3 kg per sensor |
| Output Signal | 4–20 mA analog (isolated), dual high/low level alarms |
| Communication Interface | RS-232C (cable length ≤ 10 m) |
| Power Supply | 85–264 VAC, 10 VA |
| Cable Length | 20 m standard |
| Processor | Embedded microcontroller with real-time signal processing and statistical averaging |
| Trend Logging | On-screen display of historical level data from 5 minutes to 48 hours |
| Brightness Adjustment | User-configurable LCD backlight intensity |
| Sensor Configuration | Single transmitter supports dual-sensor parallel operation |
| Brand | GreenPrima |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProLev 800 |
| Price Range | USD 1,400 – 2,800 |
| Measurement Principle | Ultrasonic Time-of-Flight (ToF) |
| Measuring Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent transducers |
| Accuracy | ±1 cm |
| Response Time | 1 s |
| Operating Ambient Temperature | −20 to +60 °C |
| Display | Large Backlit LCD with Graphical Interface (Digital Readout, Trend Plot, Echo Waveform Visualization) |
| Enclosure Rating | IP68 |
| Host Weight | 3.6 kg |
| Transducer Weight | 3.0 kg each |
| Output Signal | 4–20 mA (HART-compatible), Dual High/Low Alarm Relay Outputs |
| Communication Interface | RS-232C (cable length ≤10 m) |
| Power Supply | 85–264 VAC, 10 VA |
| Cable Length | 20 m standard |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROLEV 800 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PROLEV 800 |
| Measurement Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent ultrasonic transducers |
| Accuracy | ±1 cm |
| Response Time | 1 s |
| Operating Temperature | –20 to +60 °C |
| Display | Large-backlit LCD with graphical interface (numeric, trend plot, echo waveform) |
| Enclosure Rating | IP68 |
| Weight | 3.6 kg (transmitter), 3 kg (probe) |
| Output Signal | 4–20 mA analog output |
| Alarm Outputs | 2 programmable high/low level relays |
| Communication Interface | RS-232C (cable length ≤10 m) |
| Power Supply | 85–264 VAC, 10 VA |
| Cable Length | 20 m |
| Brand | GreenPrima |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ProLev 800 |
| Measurement Range | 0.4–10 m |
| Sensor Capacity | Up to 2 independent transducers |
| Accuracy | ±1 cm |
| Response Time | 1 s |
| Operating Ambient Temperature | −20 to +60 °C |
| Display | Large Backlit LCD with Graphical Interface (digital level, trend plot, echo waveform) |
| Enclosure Rating | IP68 |
| Weight | 3.6 kg (transmitter), 3 kg per probe |
| Output Signal | 4–20 mA (isolated), dual high/low alarm relays |
| Communication | RS-232C (cable length ≤ 10 m) |
| Power Supply | 85–264 VAC, 10 VA |
| Cable Length | 20 m |
| Trend Logging | 5 min to 48 h on display |