GreenPrima
Filter
Showing 31–60 of 480 results
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800PA |
| Measurement Principle | Acid-Base Titration with Photometric Endpoint Detection |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Protection Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 180 mm |
| Weight | 4 kg |
| Display | Color LCD with bilingual (English/Chinese) interface |
| Measurement Modes | Continuous or interval (1–360 min) |
| Output Interfaces | 4 programmable relay outputs (max. 250 V, 4 A) |
| Input Interfaces | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sample Pressure Range | 0.2–5 bar (recommended: 1–2 bar) |
| Sample Temperature Range | 5–40 °C |
| Ambient Operating Temperature | 10–40 °C |
| Sample Water Quality Requirements | pH 4–10 |
| Flush Duration | Configurable (15–1800 s) |
| Units | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | AquaLysis 800PA |
| Measurement Method | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±1% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Protection Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD with Chinese/English interface |
| Measurement Modes | Continuous or interval (1–360 min) |
| Output | 4 programmable relay outputs (250 V, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485 |
| Input | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sample Flow Pressure | 0.2–5 bar (recommended: 1–2 bar) |
| Sample Temperature | 5–40 °C |
| Ambient Temperature | 10–40 °C |
| Sample pH Range | 4–10 |
| Interference Limits | Fe < 3 ppm, Cu < 0.2 ppm, Al < 0.1 ppm, Mn < 0.2 ppm |
| Rinse Time Programmable | 15–1800 s |
| Units | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Aqualysis200SCD |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameter | Streaming Current |
| Measurement Range | −1000 to +1000 mV |
| Accuracy | ±0.1% of full scale |
| Display | LED |
| Flow Rate | 1 L/min |
| Inlet/Outlet Connections | 1/2″ inlet, 3/4″ outlet |
| Response Time | 1 second |
| Auto-zero Calibration | Yes |
| Sensor Materials | Delrin housing, 316 stainless steel wetted parts, PTFE seals |
| Output Signals | 4–20 mA, −10 to +10 V, 0–10 V |
| Communication Protocol | MODBUS RTU (optional) |
| Alarm Outputs | High/Low relay contacts |
| Enclosure Rating | IP65 |
| Dimensions | 230 × 330 mm (W × H) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Weight | 8 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis800 PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualysis800A |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis800PA |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | B sens140T |
| Measuring Range | 0–14 pH |
| Operating Temperature | −5 to 100 °C |
| Reference Electrode | Ag/AgCl Cartridge |
| Temperature Sensor | PT1000 |
| Max. Pressure | 6 bar |
| Electrode Body Material | Glass |
| Electrolyte | Gel-filled |
| Junction | Triple Ceramic Porous Diaphragm |
| Glass Membrane | S-glass |
| Minimum Immersion Depth | 20 mm |
| Zero Point | 0 ± 20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 0.1 µS/cm |
| Response Time (pH 4–7) | < 30 s |
| Thread Size | PG13.5 |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer | GreenPrima AG |
| Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measuring Parameter | Free Residual Chlorine |
| Range | 0–2.000 ppm / 0–20.00 ppm |
| Accuracy | ≤ ±2% of Full Scale |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (Automatic or Manual) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit Graphic LCD (Chinese & English) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Analog Outputs | Dual 4–20 mA (Residual Chlorine & Temperature), Max. Loop Resistance 500 Ω, Accuracy 0.1% FS |
| Cleaning Output | Adjustable Interval (0.1–1000 h) and Duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Controller Dimensions | 144 × 144 × 106 mm |
| Electrode Dimensions | Ø12 × 120 mm |
| Mounting | Wall-, Panel-, or Pole-Mounted Controller |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | Bs ens660 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameter | Free Residual Chlorine |
| Range | 0–2.000 ppm and 0–20.00 ppm |
| Accuracy | ≤ ±2% of Full Scale |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit Graphic LCD |
| Languages | English, Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Analog Outputs | Dual 4–20 mA (residual chlorine + temperature), max. loop resistance 500 Ω, accuracy 0.1% FS |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Controller Dimensions | 144 × 144 × 106 mm |
| Electrode Dimensions | Ø12 × 120 mm |
| Controller Mounting | Wall-mount, panel-mount, pole-mount |
| Electrode Mounting | PG13.5 thread, compatible with BAF615 flow cell |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Bsen s140T |
| Price Range | USD 1,400 – 4,200 |
| Measurement Range | 0–14 pH |
| Operating Temperature | −5 to 100 °C |
| Reference Electrode | Ag/AgCl Cartridge |
| Temperature Sensor | PT1000 |
| Max. Pressure | 6 bar |
| Electrode Body Material | Glass |
| Electrolyte | Gel-Filled |
| Junction | Triple Ceramic Porous Junction |
| Glass Membrane | S-Glass |
| Minimum Immersion Depth | 20 mm |
| Zero Point | ±20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 0.1 µS/cm |
| Response Time (pH 4–7) | <30 s |
| Process Connection | PG13.5 |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | BSens 140T |
| Measurement Range | 0–14 pH |
| Operating Temperature | −5 to 100 °C |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Max. Pressure Rating | 3.5 bar |
| Sensing Element | AH-Type Glass Bulb (Asymmetric Hydrogen-Responsive) |
| Reference System | Integrated Gel-Filled Ag/AgCl Reference |
| Body Material | Chemically Resistant Glass |
| Threaded Connection | PG13.5 (DIN 40430) |
| Cable Options | 5 m / 10 m / Custom Length |
| Electrolyte Type | Polymer-Gel Electrolyte (Maintenance-Free, Leakage-Resistant) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | BSens 210 |
| Measurement Range | −1500 to +1500 mV |
| Operating Temperature | −5 to 70 °C |
| Resolution | 1 mV |
| Accuracy | ±1 mV |
| Maximum Pressure Rating | 3.5 bar |
| Electrode Body Material | Borosilicate Glass / Platinum Sensing Element |
| Reference System | Gel-Filled Ag/AgCl |
| Junction Type | Ceramic Frit |
| Electrolyte | Polymer-Gel Electrolyte |
| Connection | Fixed PG13.5 Threaded Cable Port |
| Cable Length | 3 m |
| Electrode Tip Geometry | AH Glass Ball (Asymmetric Hydrophilic Bulb) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | Bsens 660 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameter | Free Residual Chlorine |
| Measurement Ranges | 0–2.000 ppm and 0–20.00 ppm |
| Accuracy | ≤ ±2% of Full Scale |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation Range | –10 to 130 °C |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70 °C |
| Output Signals | Dual 4–20 mA (residual chlorine & temperature), RS485 Modbus RTU |
| Cleaning Cycle | Adjustable from 0.1 to 1000 h |
| Duration | 1–1000 s |
| Enclosure Rating | IP65 |
| Controller Dimensions | 144 × 144 × 106 mm |
| Electrode Dimensions | Ø12 × 120 mm |
| Electrode Mounting | PG13.5 thread, compatible with BAF615 flow cell |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Bsens120/120T |
| Measurement Range | −2 to 16 pH |
| Operating Temperature | −5 to 70 °C |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Max. Pressure Rating | 3.5 bar |
| Sensing Element | AH-Type Glass Bulb |
| Reference System | Gel-Filled Dual-Junction |
| Body Material | Chemically Resistant Glass |
| Connection | Fixed PG13.5 Threaded Port |
| Cable Length | 3 m |
| Electrode Type | Combination (pH + Reference) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Imported |
| Model | Bsens120T |
| Measurement Range | pH 0–14 |
| Temperature Range | −5 to 100 °C |
| Max. Operating Pressure | 6 bar |
| Electrode Body Material | S-Glass |
| Reference System | Ag/AgCl Cartridge |
| Electrolyte | Polymer Gel |
| Electrical Impedance | ≤300 Ω at 25 °C |
| Electrode Length | 120 mm |
| Electrode Diameter | 12 mm |
| Connection Thread | PG13.5 |
| Membrane Type | S-Glass |
| Minimum Immersion Depth | 20 mm |
| Zero Point | 0 ±20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 150 μS/cm |
| Response Time (pH 4–7) | <30 s |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Bsens120T |
| Price Range | USD 850 – 1,420 |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | OEM Manufacturer |
| Product Origin | Imported |
| Model | Bsens130 |
| Operating Temperature Range | −5 °C to 135 °C |
| Pressure Rating | 6 bar |
| pH Measurement Range | 0–14 |
| Electrode Body Material | Glass |
| Reference System | Ag/AgCl Cartridge |
| Junction Type | Dual-Pore Polymer Diaphragm |
| Electrolyte | Solid-State Polymeric Gel |
| Electrode Resistance | ≤300 Ω at 25 °C |
| Zero Point | 0 ±20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 50 μS/cm |
| Response Time (pH 4.7) | <30 s |
| Immersion Depth | ≥20 mm |
| Connector | S8 (PG13.5) |
| Sensing Membrane | H-Glass |
| Cable | Not Included |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | BSens130 |
| Measuring Range | 0–14 pH |
| Operating Temperature | −5 to 135 °C |
| Resolution | 0.01 pH |
| Accuracy | ±0.01 pH |
| Max. Pressure Rating | 10 bar |
| Sensing Element | AH-Type Glass Bulb |
| Reference System | Integrated Gel-Filled Reference |
| Electrolyte | Polymer-Gel Electrolyte |
| Connector | S8 Plug |
| Thread Size | PG13.5 |
| Cable Length Options | 5 m, 10 m, or Custom |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online pH Sensor |
| Model | Bsens140T |
| Output Signals | Dual 4–20 mA, RS485 Modbus RTU |
| Operating Temperature | −5 to 100 °C |
| pH Measurement Range | 0–14 pH |
| Reference Electrode | Ag/AgCl Cartridge |
| Temperature Sensor | PT1000 |
| Max. Process Pressure | 6 bar |
| Electrode Body Material | Lab-Grade Glass |
| Electrolyte | Polymer-Gel Filled |
| Junction | Triple Ceramic Porous Diaphragm |
| pH Glass Membrane | S-Type Low-Drift Glass |
| Minimum Immersion Depth | 20 mm |
| Zero Point Offset | ±20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 0.1 µS/cm |
| Response Time (pH 4–7) | <30 s |
| Process Connection | PG13.5 Metric Thread |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Bsens 140T |
| Measurement Range | 0–14 pH |
| Operating Temperature | −5 to 100 °C |
| Reference Electrode | Ag/AgCl Cartridge |
| Electrode Body Material | Glass |
| Electrolyte | Polymer-Gel Electrolyte |
| Junction | Triple Ceramic Porous Junction |
| pH-Sensing Membrane | S-Type Low-Resistance Glass |
| Integrated Temperature Sensor | PT1000 |
| Maximum Process Pressure | 6 bar |
| Minimum Immersion Depth | 20 mm |
| Zero Potential | ±20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 0.1 µS/cm |
| Response Time (pH 4–7) | <30 s |
| Process Connection | PG13.5 |
| Standard Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial pH Sensor |
| Model | Bsens140T |
| Measuring Range | 0–14 pH |
| Operating Temperature | −5 to 100 °C |
| Reference Electrode | Ag/AgCl Cartridge System |
| Integrated Temperature Sensor | PT1000 |
| Max. Process Pressure | 6 bar |
| Electrode Body Material | Chemically Resistant Glass |
| Electrolyte | Polymer-Gel Electrolyte (Low-Flow, Maintenance-Free) |
| Junction | Triple Ceramic Porous Junction |
| pH-Sensing Membrane | S-Type High-Resistance Glass |
| Minimum Immersion Depth | 20 mm |
| Asymmetry Potential (Zero Point) | ±20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 0.1 µS/cm |
| Response Time (pH 4 → 7) | <30 s |
| Process Connection | PG13.5 Metric Thread |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Bsens140T |
| Measuring Range | 0–14 pH |
| Operating Temperature | −5 to 100 °C |
| Reference Electrode | Ag/AgCl Cartridge |
| Temperature Sensor | PT1000 |
| Max. Pressure | 6 bar |
| Electrode Body Material | Glass |
| Electrolyte | Gel Electrolyte |
| Junction | Triple Ceramic Porous Junction |
| Glass Membrane | S-Glass |
| Minimum Immersion Depth | 20 mm |
| Zero Point | 0 ± 20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 0.1 µS/cm |
| Response Time (pH 4–7) | < 30 s |
| Thread Size | PG13.5 |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Bsens140T |
| Measuring Range | 0–14 pH |
| Operating Temperature | −5 to 100 °C |
| Reference Electrode | Ag/AgCl Cartridge |
| Temperature Sensor | PT1000 |
| Max. Process Pressure | 6 bar |
| Electrode Body Material | Glass |
| Electrolyte | Polymer-Gel |
| Junction | Triple Ceramic Porous Diaphragm |
| Glass Membrane | S-Type High-Resistance Glass |
| Minimum Immersion Depth | 20 mm |
| Zero Potential | ±20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Sample Conductivity | 0.1 µS/cm |
| Response Time (pH 4–7) | <30 s |
| Process Connection | PG13.5 |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | OEM Producer |
| Origin Category | Imported |
| Model | BSENS150T |
| Electrode Body Material | HF-Resistant Glass |
| Reference System | Ag/AgCl Cartridge |
| Junction | Single Ceramic Porous Junction |
| Electrolyte | Polymer-Gel Filled |
| Connection | PG13.5 Threaded Process Connection |
| Max. Operating Pressure | 6 bar |
| Temp. Range | 0–80 °C |
| pH Range | 0–14 |
| Zero Point | ±20 mV |
| Sensitivity | 57–59 mV/pH at 25 °C |
| Impedance | ≤300 MΩ at 25 °C |
| Diameter | 12 mm |
| Length | 120 mm |
| Minimum Immersion Depth | 20 mm |
| Minimum Sample Conductivity | 50 μS/cm |
| Response Time (pH 4–7) | <30 s at 25 °C |
| HF Tolerance | Unrestricted up to 46 000 ppm F⁻ (i.e., ≥5 wt% HF) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Bsens180T |
| Pressure Rating | 6 bar |
| Operating Temperature | −5 to 100 °C |
| pH Range | 0–14 |
| Electrode Body Material | Chemically Resistant Glass |
| Reference System | Ag/AgCl Cartridge |
| Sensing Membrane | H-Type Glass |
| Junction | Triple Ceramic Porous Junction |
| Electrolyte | Polymer-Gel Filled |
| Temperature Sensor | Integrated PT1000 RTD |
| Diameter | 12 mm |
| Length | 120 mm |
| Electrical Resistance | ≤300 MΩ at 25 °C |
| Zero Potential | 0 ±20 mV |
| Slope Sensitivity | 57–59 mV/pH at 25 °C |
| Minimum Immersion Depth | 20 mm |
| Minimum Sample Conductivity | 50 µS/cm |
| Response Time (pH 4–7) | <30 s |
| Process Connection | PG13.5 Metric Thread |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Product Origin | Imported |
| Model | BSENS210 |
| Measurement Range | −2000 to +2000 mV |
| Resolution | 1 mV |
| Accuracy | ±1 mV |
| Electrode Material | Glass body with platinum sensing element |
| Operating Temperature | −5 to 70.0 °C |
| Maximum Pressure Rating | 3.5 bar |
| Electrolyte | Polymer-based gel electrolyte |
| Connection Type | Fixed PG13.5 threaded fitting |
| Cable Length | 5 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Bsens650 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential) |
| Measured Parameter | Chlorine Dioxide (ClO₂) |
| Range | 0–2 ppm and 0–20 ppm (switchable or dual-range configuration) |
| Accuracy | ≤ ±2% of reading |
| Repeatability | ±0.01 ppm |
| Resolution | 0.001 ppm |
| Limit of Detection (LOD) | 0.001 ppm |
| Operating Temperature | –5 to 100 °C |
| Max. Working Pressure | 6 bar |
| Electrode Body Material | Borosilicate Glass |
| Membrane | Triple-ceramic junction (3× porous ceramic frits) |
| Diameter | 12 mm |
| Length | 120 mm |
| Connection | PG13.5 threaded fitting |
| Cable Length | 3 m |
| Sensing Element | Dual platinum ring working electrode |
| Electrolyte | Polymer-based gel electrolyte |
| Reference System | Ag/AgCl internal reference |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | BSENS650 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensing (Constant Voltage Mode) |
| Measured Parameters | Free Chlorine, Ozone, Chlorine Dioxide |
| Measurement Ranges | 0–2.000 mg/L and 0–20.00 mg/L (dual-range auto-scaling) |
| Accuracy | ±0.01 mg/L (low range), ±0.1 mg/L (high range) |
| Repeatability | ±0.01 mg/L (low range), ±0.1 mg/L (high range) |
| Resolution | 0.01 mg/L (low range), 0.1 mg/L (high range) |
| Limit of Detection (LOD) | 0.01 mg/L (low range), 0.1 mg/L (high range) |
| Operating Temperature | –5 to 100 °C |
| Max. Working Pressure | 6 bar |
| Sensor Body Material | Chemically resistant polymer housing with borosilicate glass membrane |
| Membrane | Triple-ceramic-pore diffusion barrier |
| Diameter | 12 mm |
| Length | 120 mm |
| Electrical Connection | PG13.5 threaded gland |
| Cable Length | 3 m |
| Electrode Configuration | Dual platinum ring working electrodes |
| Minimum Immersion Depth | 25 mm |
| Electrolyte | Solid-state hydrogel |
| Reference System | Ag/AgCl quasi-reference electrode |