GreenPrima
Filter
Showing 121–150 of 480 results
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM820 2CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm (low range), 0.01 ppm (high range) |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor support) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output Signals | Dual isolated 4–20 mA (0.1% FS accuracy, max loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM820 2CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS), RS485 Modbus RTU |
| Relay Outputs | Two programmable SPDT relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Process Instrument |
| Model | PM820 2P |
| Measurement Range | -2 to 16 pH, -2000 to +2000 mV, 0 to 130 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±0.1 mV, ±0.1 °C |
| Temperature Compensation Range | -10 to 130 °C (manual/automatic |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online pH Meter |
| Model | PM820 2P |
| Measurement Range | –2.00 to 16.00 pH |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH ±1 digit, ±1 mV ±1 digit, ±0.2 °C ±1 digit |
| Calibration | Two-point auto-calibration (standard buffers: 1.68, 4.01, 6.86, 7.00, 9.18, 10.01, 12.45 pH) |
| Temperature Compensation | Automatic Pt1000 or manual |
| Output | Dual isolated 4–20 mA (600 Ω max load) |
| Relay Outputs | Two programmable Hi/Lo contacts (230 VAC, 5 A) |
| Display | Backlit dot-matrix LCD |
| Enclosure Rating | IP65 |
| Operating Temperature | –10.0 to +70.0 °C |
| Storage Temperature | –20.0 to +70.0 °C |
| Relative Humidity | ≤90 % RH (non-condensing) |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Dimensions | 144 H × 144 W × 108 D mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online pH Meter |
| Model | PM820-2P |
| Measurement Range | -2 to 16 pH, -2000 to +2000 mV, 0 to 130 °C |
| Resolution | 0.01 pH, 1 mV, 0.1 °C |
| Accuracy | ±0.01 pH, ±0.1 mV, ±0.1 °C |
| Temperature Compensation Range | -10 to 130 °C (manual/automatic |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | PM8200 S |
| Instrument Type | Online |
| Measurement Principle | 90° Near-Infrared Light Scattering |
| Compliance | EN ISO 7027 |
| Sensor Type | Bsens580 High-Turbidity Sensor |
| Measuring Range | 5–4000 NTU / 0–4500 mg/L (as SS) |
| Resolution | 0.01–1 NTU (or mg/L) |
| Accuracy | < ±5% of reading |
| Temperature Compensation | NTC10K or PT1000, -10 to 130 °C (manual/automatic) |
| Operating Temperature (Controller) | 0–70 °C |
| Operating Temperature (Sensor) | 0–50 °C |
| Storage Temperature | -20 to 70 °C |
| Max. Pressure (Sensor) | 5 bar |
| Sensor Housing | IP68 |
| Controller Enclosure | IP65 |
| Display | Backlit dot-matrix LCD with Chinese/English menu |
| Output | Dual isolated 4–20 mA (0.1% FS, max. 500 Ω), RS485 Modbus RTU (HART optional) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Mounting Options | Wall-mounted, pipe-mounted, panel-mounted |
| Dimensions (Controller) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight (Controller) | 0.86 kg |
| Sensor Dimensions | Ø27 × 170 mm |
| Standard Cable Length | 7 m |
| Brand | GreenPrima |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | PM8200C |
| Conductivity Range | 0.00–2000 mS/cm |
| Salinity Range | 0.00–78.00 ppt |
| TDS Range | 0–120,000 ppm |
| Conductivity Resolution | 0.01 mS/cm (varies by sensor) |
| Salinity/TDS Resolution | 0.01 ppt / 1 ppm |
| Accuracy | ±1% F.S. |
| Temperature Compensation | -10–130 °C (NTC30k or PT1000, manual/automatic) |
| Operating Temperature | -10–70 °C |
| Storage Temperature | -20–70 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Calibration Codes | 1100 (calibration), 1200 (setup) |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. 500 Ω, 0.1% F.S.) |
| Communication | RS485 Modbus RTU (HART optional) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relays (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Compatibility | Bsens310 (K=0.01), Bsens320 (K=0.1), Bsens330 (K=1), Bsens340 (K=0.5), Bsens350 (K=10) |
| Sensor Materials | 316L stainless steel, titanium, graphite |
| Sensor Pressure Rating | Up to 5 bar |
| Sensor Thread | 3/4" NPT |
| Sensor IP Rating | IP68 |
| Brand | GreenPrima |
|---|---|
| Model | PM8200C |
| Measurement Parameters | Conductivity (0.00–2000 mS/cm), Salinity (0.00–78.00 ppt), TDS (0–120,000 ppm) |
| Accuracy | ±1% F.S. for all parameters |
| Temperature Compensation Range | −10 to 130 °C (NTC10K or PT1000 sensor support) |
| Display | Backlit graphical LCD with adjustable contrast |
| Data Storage | 600,000 records with timestamped query capability |
| Output | Dual isolated 4–20 mA (max. 500 Ω, 0.1% F.S.), RS485 Modbus RTU |
| Relay | One multifunction relay (cleaning control, periodic alarm, fault alarm) |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 106 mm (panel cutout: 138 × 138 mm) |
| Weight | 0.86 kg |
| Electrode Compatibility | Bsens310–350 series (K = 0.01 to 10 cm⁻¹, IP68, Ti alloy or graphite body, 3/4″ NPT or 1/2″ NPT) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer | GreenPrima Ltd. |
| Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0–2.000 ppm / 0–20.00 ppm (dual-range auto-scaling) |
| Accuracy | ±0.001 ppm or ±0.01 ppm (full-scale dependent) |
| Repeatability | ±0.001 ppm or ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| LOD | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000, manual/automatic) |
| Operating Temp. | 0–70 °C |
| Storage Temp. | –20 to 70 °C |
| Display | Backlit graphical LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Enclosure Rating | IP65 |
| Communications | RS485, MODBUS-RTU compliant |
| Analog Outputs | Dual isolated 4–20 mA (max. 500 Ω, ±0.1% FS) |
| Cleaning Output | Programmable interval (0.1–1000 h) and duration (1–1000 s) |
| Housing Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Range | 0–2.000 / 0–20.00 ppm |
| Sensor Accuracy | ±2% FS |
| Sensor Electrode Material | Glass body with dual-platinum ring working electrode |
| Max. Pressure Rating | 5 bar |
| Connection | PG13.5 fixed thread |
| Cable Length | 3 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer | GreenPrima AG |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Voltage Mode) |
| Measured Parameter | Chlorine Dioxide (ClO₂) |
| Range | 0–2.000 mg/L and 0–20.00 mg/L |
| Accuracy | ±2% of reading |
| Repeatability | ±0.01 mg/L |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Temperature Compensation | Automatic or Manual (NTC10K / PT1000) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | −20–70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Output Signals | Dual isolated 4–20 mA (0.1% FS), RS485 Modbus RTU (HART optional) |
| Relay Outputs | 2 programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions (Controller) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 (Ag/AgCl reference, gel electrolyte, dual Pt working electrodes, Φ12 × 120 mm, max. pressure 6 bar, PG13.5 or M12 connector, 3 m cable standard) |
| Optional Sensor | Bsens660 (dual gold-ring ClO₂ sensor for enhanced low-concentration stability) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Voltage Mode) |
| Measured Parameter | Chlorine Dioxide (ClO₂) |
| Range Options | 0–2.000 ppm and 0–20.00 ppm |
| Accuracy | ≤2% of Full Scale (F.S.) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Operating Temperature | 0–70 °C |
| Storage Temperature | −20–70 °C |
| Temperature Compensation | −10–130 °C (Manual/Automatic |
| Display | Backlit Graphic LCD |
| Languages | Simplified Chinese, Traditional Chinese, English |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz (24 VDC optional) |
| Analog Outputs | Two isolated 4–20 mA channels (ClO₂ and temperature, max. load 500 Ω) |
| Communication | RS485 Modbus RTU (HART optional) |
| Relay Outputs | Three programmable relays (5 A / 250 VAC / 30 VDC), with independent Hi/Lo alarm points and hysteresis |
| Cleaning Control | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mounted, panel-mounted, or pipe-mounted (controller) |
| Dimensions (W×H×D) | 144 × 144 × 106 mm |
| Cutout Size | 138 × 138 mm |
| Weight | 0.86 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameter | Dissolved Ozone (O₃) |
| Range | 0–2.000 ppm / 0–20.00 ppm |
| Accuracy | ≤ ±2% of Full Scale |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Limit of Detection | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (Manual/Automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit Graphic LCD |
| Languages | English, Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Analog Outputs | Dual 4–20 mA (O₃ concentration & temperature), max. loop resistance 500 Ω, accuracy 0.1% FS |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Controller Dimensions | 144 × 144 × 106 mm |
| Electrode Dimensions | Ø12 × 120 mm |
| Controller Mounting | Wall-mount, panel-mount, or pole-mount |
| Electrode Mounting | PG13.5 thread with BAF615 constant-flow cell |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Amperometric Sensor (Three-Electrode System with Dual Platinum Working Electrodes) |
| Measured Parameters | Residual Chlorine, Chlorine Dioxide, Dissolved Ozone (O₃) |
| Measurement Ranges | 0–2.000 ppm and 0–20.00 ppm (switchable) |
| Accuracy | ±0.001 ppm / ±0.01 ppm (depending on range) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Limit of Detection (LOD) | 0.001 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000 selectable, manual/automatic) |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit dot-matrix LCD |
| Language Interface | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communication | RS485 Modbus RTU protocol |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Cleaning Control Output | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 Ozone Electrode |
| Electrode Material | Borosilicate glass body |
| Sensing Element | Triple-ceramic-pore membrane with dual platinum ring working electrodes and Ag/AgCl reference system |
| Electrolyte | Solid-state gel electrolyte |
| Max. Operating Pressure | 6 bar |
| Temp. Range (Electrode) | –5 to 100 °C |
| Immersion Depth (min.) | 25 mm |
| Cable Length | 3 m |
| Connection | PG13.5 threaded fitting |
| Flow Stabilization Module | BAF615 constant-flow cell |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor |
| Measured Parameter | Free Residual Chlorine (Cl₂) |
| Range | 0–2.000 ppm / 0–20.00 ppm |
| Accuracy | ±0.001 ppm / ±0.01 ppm |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| LOD | 0.001 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000, manual/auto) |
| Operating Temp. | 0–70.0 °C |
| Storage Temp. | –20 to 70.0 °C |
| Display | Backlit dot-matrix LCD |
| Language | English & Chinese selectable |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Enclosure Rating | IP65 |
| Communications | RS485 Modbus RTU |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor | Bsens650 amperometric chlorine electrode (dual Pt ring working electrodes, Ag/AgCl reference, ceramic frit membrane, gel electrolyte, glass body, PG13.5 connector, 3 m cable, Ø12 mm × 120 mm, min. immersion depth 25 mm, max. pressure 6 bar, temp. range –5 to 100 °C) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Voltage Technique) |
| Measured Parameter | Residual Chlorine Dioxide (ClO₂) |
| Range | 0–2.000 ppm / 0–20.00 ppm |
| Accuracy | ≤ ±2% of Full Scale |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (Manual/Automatic) |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit Graphic LCD |
| Languages | English, Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or Optional 24 VDC |
| Analog Outputs | Dual 4–20 mA (ClO₂ concentration & temperature |
| Cleaning Output | Adjustable interval (0.1–1000 h), duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Controller Dimensions | 144 × 144 × 106 mm |
| Electrode Dimensions | Ø12 × 120 mm |
| Mounting Options | Wall-mount, panel-mount, pole-mount |
| Electrode Connection | PG13.5 thread |
| Flow Cell | BAF615 constant-flow chamber |
| Sensor Element | Bsens660 gold-ring amperometric electrode |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Sensor (Constant Voltage Polarography) |
| Measured Parameters | Free Chlorine, Chlorine Dioxide, Ozone |
| Measurement Range | 0–2.000 ppm and 0–20.00 ppm (dual-range auto-scaling) |
| Accuracy | ±0.001 ppm / ±0.01 ppm (depending on range) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 selectable, manual/automatic) |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit graphical LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communication | RS485, MODBUS-RTU compliant |
| Analog Outputs | Two isolated 4–20 mA outputs (max. 500 Ω, accuracy ±0.1% FS) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Electrode Material | Glass body with dual-platinum ring working electrode |
| Max. Pressure Rating | 5 bar |
| Cable Length | 3 m |
| Sensor Operating Temp. | 0–70.0 °C |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Imported |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric (Constant Potential) Electrochemical Sensor |
| Measured Parameters | Chlorine Dioxide (ClO₂), Free Chlorine (Cl₂), Ozone (O₃) |
| Range | 0–2.000 ppm / 0–20.00 ppm (dual-range auto-scaling) |
| Accuracy | ±0.001 ppm / ±0.01 ppm |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| LOD | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000, manual/auto) |
| Operating Temp. | 0–70.0 °C |
| Storage Temp. | –20 to 70.0 °C |
| Display | Backlit dot-matrix LCD with bilingual (English/Chinese) menu |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communications | RS485, MODBUS-RTU compliant |
| Analog Outputs | Two isolated 4–20 mA outputs (max. 500 Ω, ±0.1% FS) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Electrode Model | Bsens650 |
| Electrode Range | 0–2.000 / 0–20.00 ppm |
| Electrode Accuracy | ±2% FS |
| Electrode Material | Glass body with dual-platinum ring sensing element |
| Max. Pressure Rating | 5 bar |
| Connection | PG13.5 threaded fitting |
| Cable Length | 3 m |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant-Potential Method) |
| Measured Parameter | Dissolved Ozone (O₃) |
| Range | 0–2.000 ppm and 0–20.00 ppm |
| Accuracy | ≤ ±2% of Full Scale |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit Graphic LCD |
| Language Support | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Analog Outputs | Dual 4–20 mA (O₃ concentration + temperature), max. loop resistance 500 Ω, accuracy 0.1% FS |
| Cleaning Output | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Controller Dimensions | 144 × 144 × 106 mm |
| Electrode Dimensions | Ø12 × 120 mm |
| Controller Mounting | Wall-mount, panel-mount, or pole-mount |
| Electrode Mounting | PG13.5 thread, compatible with BAF615 flow cell |
| Brand | GreenPrima |
|---|---|
| Model | PM 8200CL |
| Measurement Range | 0–2.000 ppm / 0–20.00 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Accuracy | ±0.001 ppm / ±0.01 ppm |
| Temperature Compensation | Pt1000 & NTC10K |
| Temp. Compensation Range | −10.0–130.0 °C |
| Operating Temp. | 0–70.0 °C |
| Storage Temp. | −20–70.0 °C |
| Display | Backlit Graphic LCD |
| Data Storage | 600,000 records |
| Output | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS) & RS485 Modbus RTU |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Mounting | Wall, panel, or pipe |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Temperature |
| Measurement Range | 0.00–2.000 ppm / 0.00–20.00 ppm |
| Accuracy | ±2% of Full Scale |
| Repeatability | ±0.01 ppm |
| Resolution | 0.001 ppm (low range), 0.01 ppm (high range) |
| Detection Limit | 0.01 ppm |
| Temperature Compensation | Automatic (Pt1000 sensor, ±10.0 °C offset adjustable) or Manual |
| Operating Temperature | –10.0 to +60.0 °C |
| Relative Humidity | 10–90% RH (non-condensing) |
| Display | Backlit LCD (44 × 65 mm, yellow backlight) |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Output Signals | Two isolated 4–20 mA outputs (configurable, max. 600 Ω load) |
| Relay Outputs | Two independent SPDT relays (Hi/Lo alarm with hysteresis, 5 A / 250 VAC or 5 A / 30 VDC) |
| Enclosure Rating | IP65 |
| Mounting | Panel mount |
| Dimensions (H×W×D) | 144 × 144 × 110 mm |
| Cutout Size | 136 × 136 mm |
| Weight | 0.8 kg |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Voltage Method) |
| Measured Parameter | Free Residual Chlorine |
| Range | 0–2.000 ppm and 0–20.00 ppm |
| Accuracy | ≤ ±2% of Full Scale |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic) |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit Graphic LCD |
| Languages | English, Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Analog Outputs | Dual 4–20 mA (residual chlorine & temperature), max. loop resistance 500 Ω, accuracy 0.1% FS |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Controller Dimensions | 144 × 144 × 106 mm |
| Electrode Dimensions | Ø12 × 120 mm |
| Controller Mounting | Wall-mount, panel-mount, or pole-mount |
| Electrode Connection | PG13.5 thread, compatible with BAF615 flow cell |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameter | Free Residual Chlorine |
| Range | 0–2.000 ppm and 0–20.00 ppm |
| Accuracy | ≤ ±2% of Full Scale |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (Manual/Automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70 °C |
| Display | Backlit Graphic LCD |
| Language Support | English, Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or Optional 24 VDC |
| Analog Outputs | Dual 4–20 mA (Residual Chlorine & Temperature), Max. Loop Resistance 500 Ω, Accuracy 0.1% FS |
| Cleaning Output | Adjustable Interval (0.1–1000 h) and Duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Controller Dimensions | 144 × 144 × 106 mm |
| Electrode Dimensions | Ø12 × 120 mm |
| Controller Mounting | Wall-mount, Panel-mount, Pole-mount |
| Electrode Mounting | PG13.5 thread or Flow Cell (BAF615) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM 8200Cl |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameter | Free Chlorine (Cl₂) |
| Measurement Ranges | 0–2.000 ppm and 0–20.00 ppm |
| Accuracy | ±0.001 ppm / ±0.01 ppm |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000, manual/automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Enclosure Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Communication | RS485 with standard MODBUS RTU protocol |
| Relay Output | 1 multifunctional relay (cleaning control, periodic alarm, fault alarm) |
| Data Logging | 600,000 records with timestamped query capability |
| Display | Backlit graphical LCD with adjustable contrast |
| User Interface | Bilingual (English/Chinese), password-protected, keyless operation with auto-backlight timeout |
| Mounting Options | Wall-mounted, panel-mounted, or pipe-mounted |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Range | 0–2.000 ppm / 0–20.00 ppm |
| Sensor Accuracy | ±2% FS |
| Sensor Electrode Material | Glass body with dual platinum ring working electrode |
| Sensor Operating Temperature | 0–70.0 °C |
| Max. Pressure Rating | 5 bar |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0–2.000 ppm and 0–20.00 ppm (dual-range auto-scaling) |
| Accuracy | ±0.001 ppm / ±0.01 ppm (depending on range) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 selectable, manual/automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD with bilingual (English/Chinese) menu |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communication | RS485, MODBUS-RTU compliant |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Cleaning Control Output | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Material | Glass body with dual-platinum ring electrode |
| Max. Pressure Rating | 5 bar |
| Cable Length | 3 m |
| Electrode Accuracy | ±2% FS |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Voltage Polarography) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0–2.000 ppm and 0–20.00 ppm (dual-range auto-scaling) |
| Accuracy | ±0.001 ppm / ±0.01 ppm (depending on range) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| LOD | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000, manual/automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communication | RS485, MODBUS-RTU compliant |
| Analog Outputs | Two isolated 4–20 mA outputs (max. 500 Ω, ±0.1% FS) |
| Cleaning Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Range | 0–2.000 / 0–20.00 ppm |
| Sensor Accuracy | ±2% FS |
| Sensor Electrode Material | Glass body with dual-platinum ring working electrode |
| Max. Pressure Rating | 5 bar |
| Cable Length | 3 m |
| Connection | PG13.5 threaded gland |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Electrochemical Sensor |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Measurement Range | 0–2.000 ppm and 0–20.00 ppm (dual-range auto-switching) |
| Accuracy | ±0.001 ppm / ±0.01 ppm (depending on range) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 selectable, manual/automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit dot-matrix LCD with bilingual (English/Chinese) menu |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communication | RS485, MODBUS-RTU compliant |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mounted, pipe-mounted (rod), or panel-mounted |
| Dimensions (H×W×D) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Electrode Material | Glass body with dual-platinum ring working electrode |
| Max. Pressure Rating | 5 bar |
| Cable Length | 3 m |
| Sensor Operating Temperature | 0–70.0 °C |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer | GreenPrima Ltd. |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Voltage Polarography) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0–2.000 ppm / 0–20.00 ppm (dual-range auto-scaling) |
| Accuracy | ±0.001 ppm / ±0.01 ppm (depending on range) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| LOD | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10k or PT1000 selectable, manual/automatic) |
| Operating Temp. | 0–70 °C |
| Storage Temp. | -20 to 70 °C |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Enclosure Rating | IP65 |
| Display | Backlit graphical LCD |
| Language | English / Chinese menu |
| Data Storage | 600,000 records |
| Outputs | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS), RS485 Modbus RTU |
| Cleaning Control | Programmable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor | Bsens650 amperometric electrode (glass body, dual-platinum ring working electrode) |
| Flow Cell | BAF615 flow-through cell (PG13.5 thread, max. 5 bar, 3 m cable) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Voltage Polarography) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0–2.000 ppm and 0–20.00 ppm (dual-range auto-scaling) |
| Accuracy | ±0.001 ppm / ±0.01 ppm (depending on range) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 selectable, manual/automatic) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD with bilingual (English/Chinese) menu |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Communication | RS485, MODBUS-RTU compliant |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS) |
| Cleaning Control Output | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pole-mount, panel-mount |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Material | Glass body with dual-platinum ring electrode |
| Max. Pressure Rating | 5 bar |
| Cable Length | 3 m |
| Electrode Accuracy | ±2% FS |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0–2.000 ppm / 0–20.00 ppm (dual-range auto-switching) |
| Accuracy | ±0.001 ppm / ±0.01 ppm (depending on range) |
| Repeatability | ±0.001 ppm / ±0.01 ppm |
| Resolution | 0.001 ppm / 0.01 ppm |
| Detection Limit | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000 selectable) |
| Operating Temperature | 0–70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit Graphic LCD |
| Language | English & Chinese (configurable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Enclosure Rating | IP65 |
| Communication | RS485, MODBUS-RTU compliant |
| Analog Outputs | Two isolated 4–20 mA outputs (max. 500 Ω, ±0.1% FS) |
| Cleaning Control | Programmable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (H×W×D) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Sensor Model | Bsens650 |
| Sensor Electrode Material | Glass body with dual-platinum ring working electrode |
| Max. Pressure Rating | 5 bar |
| Cable Length | 3 m |
| Sensor Operating Temp. | 0–70.0 °C |