| Model | PM8200P |
| Measurement Range | −2000 to +2000 mV, 0 to 130 °C |
| Resolution | 1 mV, 0.1 °C |
| Accuracy | ±0.1 mV, ±0.1 °C |
| Temperature Compensation | −10 to 130 °C (manual/automatic |
| Operating Temperature | −10 to 70.0 °C |
| Storage Temperature | −20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English/Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S.) |
| Communication | RS485 Modbus RTU (HART optional) |
| Cleaning Control | Adjustable interval (0.1–1000 h), duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay outputs (5 A / 250 VAC / 30 VDC) |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Compatible Sensors | Bsens series pH/ORP electrodes (e.g., Bsens 210 ORP sensor: range ±2000 mV, operating temp −5 to 100 °C, polymer electrolyte, dual-pore diaphragm, platinum ring sensing element) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Process Analyzer |
| Model | PM 8200P |
| Output Signals | Dual 4–20 mA, RS485 Modbus RTU |
| Enclosure Rating | IP67 |
| Display | Backlit Graphic LCD with Multilingual UI (English & Chinese) |
| Sensor Interface | Dedicated BSENS140T pH Electrode |
| Compliance | CE, RoHS, ISO 9001 Certified |
| Operating Temperature | -10 to 60°C (electronics), -5 to 100°C (sensor) |
| Max. Process Pressure | 6 bar |
| Minimum Sample Conductivity | 0.1 µS/cm |
| Response Time (pH 4–7) | <30 s |
| Electrode Material | S-Glass Membrane |
| Reference System | Ag/AgCl Cartridge |
| Temperature Sensor | PT1000 Integrated |
| Junction | Triple Ceramic Diaphragm |
| Electrolyte | Polymer-Gel Filled |
| Submersion Depth | ≥20 mm |
| Zero Point | 0 ±20 mV |
| Sensitivity | 57–59 mV/pH @ 25°C |
| Cable Length | 5 m (shielded, PVC jacket) |
| Brand | GreenPrima |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | PM8200P |
| Measurement Range | pH: −2.00–16.00 |
| ORP | −2000–+2000 mV |
| Resolution | pH: 0.01 pH |
| ORP | 1 mV |
| Accuracy | pH: ±0.01 pH |
| ORP | ±1 mV |
| Temperature Compensation | −10–130 °C (NTC10k or PT1000, auto/manual) |
| Display | Backlit dot-matrix LCD |
| Data Storage | 600,000 records |
| Output | Dual isolated 4–20 mA (max. 500 Ω, 0.1% FS) |
| Communication | RS485, MODBUS RTU compliant |
| Relay Control | Dual programmable relays with adjustable hysteresis |
| Cleaning Function | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Enclosure Rating | IP65 |
| Operating Temperature | 0–70 °C |
| Storage Temperature | −20–70 °C |
| Dimensions | 144 × 144 × 106 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.86 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8200S |
| Instrument Type | Online |
| Measurement Principle | 90° Near-Infrared Light Scattering |
| Compliance | EN ISO 7027 |
| Sensor Type | Bsens580L Low-Turbidity Sensor |
| Range | 0–10 NTU / 0–100 NTU |
| Resolution | 0.01 NTU (0–10 NTU), 0.1 NTU (0–100 NTU) |
| Accuracy | ±1% FS (0–10 NTU), ±2% FS (0–50 NTU), ±5% FS (0–100 NTU) |
| Operating Temp. | 0–50 °C (sensor), –10–70.0 °C (controller) |
| Max. Pressure | 4 bar |
| Output | Dual isolated 4–20 mA, RS485 Modbus RTU, optional HART |
| Enclosure Rating | IP65 (controller), IP68 (sensor) |
| Display | Backlit dot-matrix LCD with Chinese/English menu |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC option |
| Dimensions (controller) | 144 × 144 × 106 mm |
| Mounting | Wall, pipe, or panel mount |
| Weight | 0.86 kg |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8200S+BSens550 |
| Instrument Type | Online |
| Measurement Principle | 90° Light Scattering (EN ISO 7027 Compliant) |
| Controller Display | Sludge Concentration, Relay Status, Sensor Model |
| Language | English/Chinese |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Analog Outputs | Two 4–20 mA (Concentration & Temperature), Max. Load 600 Ω |
| Digital Output | RS485 Modbus RTU |
| Alarm Outputs | Two Independent Hi/Lo Setpoints with Hysteresis, 5 A / 250 VAC |
| Cleaning Interval | Field-Configurable (1–999 hours) |
| Operating Temperature (Controller) | −10 to +60 °C |
| Enclosure Rating (Controller) | IP65 / NEMA 4X |
| Mounting | Wall-Mount |
| Dimensions (Controller) | 144 × 144 × 108 mm |
| Sensor Model | innoSens 550 |
| Sensor Measurement Range | 0–50 g/L |
| Resolution | 0.1 NTU / 0.1 mg/L |
| Accuracy | ±2% of Full Scale |
| Sensor Housing Material | Delrin® |
| Cable Length | Standard 7 m |
| Max. Pressure Rating (Sensor) | 5 bar |
| Sensor Operating Temperature | 0–60 °C |
| Sensor Enclosure Rating | IP68 |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202 CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Electrochemistry |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor input) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English UI) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output Signals | Dual isolated 4–20 mA (0.1% FS, max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202 CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to +130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Output | Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | 2 programmable SPDT relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Logic | Dual independent Hi/Lo setpoints with user-defined hysteresis |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Mounting Options | Wall-mounted, Pipe-mounted, Panel-mounted |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202 I |
| Pricing | Available Upon Request |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) for Calcium²⁺ |
| Range | 0.00–20,000 ppm CaCO₃ equivalent |
| Resolution | 0.01 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 ppm (≤1 ppm), ±0.1 ppm (1–100 ppm), ±1 ppm (>100 ppm) |
| Temperature Compensation | –10 to +130 °C (NTC30k or PT1000 sensor, manual/automatic) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit dot-matrix LCD with real-time Ca²⁺ concentration, temperature, timestamp, and relay status |
| Data Storage | 600,000 records with timestamped logging |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1 % FS, configurable for Ca²⁺ or temperature) |
| Communication | RS485 Modbus RTU protocol |
| Cleaning Control | Programmable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Outputs | Two independent Hi/Lo relay alarms (5 A @ 250 VAC / 30 VDC, adjustable hysteresis) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202 O |
| Instrument Type | Online |
| Measurement Principle | Fluorescence Quenching |
| Measurement Range | 0.00–20.00 ppm |
| Accuracy | ±0.01 ppm |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202C |
| Price | Upon Request |
| Measurement Range (Conductivity) | 0.00–2000 mS/cm |
| Measurement Range (Salinity) | 0.00–78.00 ppt |
| Measurement Range (TDS) | 0–120,000 ppm |
| Resolution (Conductivity) | 0.01 mS/cm (varies by electrode) |
| Accuracy | ±1% of Full Scale |
| Temperature Compensation | –10 to 130 °C, manual or automatic (NTC10K / PT1000) |
| Operating Temperature | 0 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Power Supply | 90–260 VAC, 50/60 Hz |
| Analog Outputs | Two isolated 4–20 mA outputs, max loop resistance 500 Ω, accuracy 0.1% F.S. |
| Cleaning Output | Adjustable interval (0.1–1000 h), adjustable duration (1–1000 s) |
| Enclosure Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| IP Rating | IP68 (electrodes) |
| Electrode Options | Bsens310 (0–20.00 µS/cm, K=0.01), Bsens320 (0–200.0 µS/cm, K=0.1), Bsens330 (0–2000 µS/cm, K=1), Bsens340 (0–500 mS/cm, K=0.5), Bsens350 (0.1–2000.0 mS/cm, K=10) |
| Electrode Materials | 316L stainless steel (Bsens310–330), titanium alloy (Bsens340), graphite (Bsens350) |
| Process Connection | 3/4" NPT |
| Max Pressure Rating | 5 bar |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online Analyzer |
| Model | PM8202C |
| Application | Continuous Process Monitoring in Industrial Water, Wastewater, and Chemical Processing |
| Conductivity Range | 0.00–2000 mS/cm |
| Salinity Range | 0.00–78.00 ppt |
| TDS Range | 0–120,000 ppm |
| Conductivity Resolution | 0.01 mS/cm |
| Salinity Resolution | 0.01 ppt |
| TDS Resolution | 1 ppm |
| Accuracy | ±1% of Full Scale |
| Temperature Range | –10 to +130 °C (manual/automatic compensation |
| Operating Temperature | –10 to +70 °C |
| Storage Temperature | –20 to +70 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese (configurable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Digital Communication | RS485 Modbus RTU (HART optional) |
| Relay Outputs | One multifunction relay (programmable), two independent Hi/Lo alarm relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, panel-mount, pipe-mount |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Process Analyzer |
| Model | PM8202C |
| Conductivity Range | 0.00–2000 mS/cm |
| Salinity Range | 0.00–78.00 ppt |
| TDS Range | 0–120,000 ppm |
| Temperature Operating Range | −10 to +70.0 °C |
| Temperature Storage Range | −20 to +70.0 °C |
| Conductivity Resolution | 0.01 µS/cm (at low range), 0.1 mS/cm (at high range) |
| Salinity Resolution | 0.01 ppt |
| TDS Resolution | 1 ppm |
| Display | Backlit graphical LCD |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Dual isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% F.S.), RS485 Modbus RTU (HART optional) |
| Relay Outputs | Two programmable SPDT relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Temperature Compensation | Automatic or manual, supports NTC30k and PT1000 sensors (−10 to +130 °C) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-mount, panel-mount, in-line pipe installation |
| Cut-out Dimensions | 138 × 138 mm |
| External Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Industrial Process Instrument |
| Model | PM8202C |
| Conductivity Range | 0.00–2000 mS/cm |
| Salinity Range | 0.00–78.00 ppt |
| TDS Range | 0–120,000 ppm |
| Conductivity Resolution | 0.01 µS/cm (at low range), 0.1 mS/cm (at high range) |
| Salinity Resolution | 0.01 ppt |
| TDS Resolution | 1 ppm |
| Temperature Compensation | Automatic/manual, -10 to 130 °C (NTC30k or PT1000 sensor compatible) |
| Accuracy | ±1% of full scale |
| Display | Backlit graphical LCD |
| Data Storage | 600,000 records with timestamp |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Output | Two isolated 4–20 mA outputs (max. 500 Ω, 0.1% FS), configurable for conductivity, temperature, or derived parameters |
| Communication | RS485 Modbus RTU standard |
| Relay Outputs | Two programmable SPDT relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Logic | Dual independent Hi/Lo setpoints with user-defined hysteresis |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Online Conductivity Analyzer |
| Model | PM8202C |
| Conductivity Range | 0.00–2000 mS/cm |
| Salinity Range | 0.00–78.00 ppt |
| TDS Range | 0–120,000 ppm |
| Conductivity Resolution | 0.01 µS/cm (at low range), 0.1 mS/cm (at high range) |
| Salinity Resolution | 0.01 ppt |
| TDS Resolution | 1 ppm |
| Temperature Compensation | Automatic/manual, -10 to 130 °C (NTC30k or PT1000 sensor compatible) |
| Display | Backlit graphical LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Output | Dual isolated 4–20 mA (≤500 Ω load, 0.1% FS accuracy), RS485 Modbus RTU (HART optional) |
| Relay Outputs | 2 programmable SPDT relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Logic | Hi/Lo with adjustable hysteresis |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Installation | Wall-mount, panel-mount, or in-line pipe mounting |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Industrial Process Instrument |
| Model | PM8202C |
| Conductivity Range | 0.00–2000 mS/cm |
| Salinity Range | 0.00–78.00 ppt |
| TDS Range | 0–120,000 ppm |
| Temperature Operating Range | −10 to +70.0 °C |
| Storage Temperature Range | −20 to +70.0 °C |
| Conductivity Resolution | 0.01 µS/cm (at low range), 0.1 mS/cm (at high range) |
| Salinity Resolution | 0.01 ppt |
| TDS Resolution | 1 ppm |
| Display | Backlit graphic LCD |
| Temperature Compensation | Automatic/manual (NTC30k or PT1000 sensor input) |
| Accuracy | ±1% of full scale |
| Enclosure Dimensions | 144 × 144 × 108 mm |
| Weight | 0.87 kg |
| Protection Rating | IP65 |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC (optional) |
| Output | Dual isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% FS) |
| Communication | RS485 Modbus RTU (standard), HART (optional) |
| Relay Outputs | 2 programmable SPDT relays (5 A / 250 VAC / 30 VDC) |
| Data Logging | 600,000 records with timestamp |
| Cleaning Control Output | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Mounting Options | Wall-mount, panel-mount, in-line pipe mount |
| Password Protection | Yes |
| Factory Reset | One-button restore |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202C-L |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Detection |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202C-L |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Constant Potential (Fixed-Voltage Amperometry) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 selectable) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS, max. loop resistance 500 Ω) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202CL |
| Price | Upon Request |
| Measurement Principle | Amperometric (Constant Voltage Detection) |
| Measurable Parameters | Free Chlorine, Chlorine Dioxide, Ozone |
| Sensor Type | Dual Platinum Electrode (Membrane-Free, Reagent-Free) |
| Flow Cell | BAF615 Flow-Through Cell |
| Pipe Compatibility | DN50–DN100 |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 Records |
| Output | Dual Isolated 4–20 mA (0.1% FS), RS485 Modbus RTU, Relay Alarms (2× Hi/Lo, 5 A) |
| Cleaning Control | Programmable Interval (0.1–1000 h) & Duration (1–1000 s) |
| Temp. Compensation | Automatic/Manual (NTC10K or PT1000), Range: −10 to +130 °C |
| Operating Temp. | −10 to +70.0 °C |
| Storage Temp. | −20 to +70.0 °C |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Electrochemistry |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to +130 °C (NTC10K or PT1000 sensor support) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (≤500 Ω, 0.1% F.S.), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Detection |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Measurement Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or Optional 24 VDC |
| Output | Dual Isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω) |
| Alarm Outputs | Two Independent Hi/Lo Setpoints with Hysteresis |
| Cleaning Control | Adjustable Interval (0.1–1000 h) and Duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Mounting Options | Wall-Mount, Panel-Mount, In-Line Pipe Installation |
| Dimensions | 144 × 144 × 108 mm |
| Cutout Size | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric (Constant Voltage) |
| Measured Parameters | Residual Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% F.S. |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit Graphic LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | 2 programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Cycle | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric (Constant Voltage) |
| Measured Parameters | Residual Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% F.S. |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit Graphic LCD |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Outputs | Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | Two independent Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage (Three-Electrode System) |
| Measured Parameters | Free Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm (low range), 0.01 ppm (high range) |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 selectable) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS, max. loop resistance 500 Ω) |
| Cleaning Interval | 0.1–1000 h |
| Duration | 1–1000 s |
| Alarm | Two independent Hi/Lo setpoints with hysteresis |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Residual Chlorine, Combined Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (max. loop resistance 500 Ω, accuracy 0.1% F.S.), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC), one multifunction relay |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Installation Options | Wall-mount, pipe-mount, panel-mount |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (Constant Potential Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 selectable) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | 2 programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Detection |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm (low range), 0.01 ppm (high range) |
| Accuracy | ±2% of Full Scale |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor input) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Dual isolated 4–20 mA (≤500 Ω, 0.1% FS), RS485 Modbus RTU |
| Relay Outputs | Two programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Detection at Fixed Potential (Constant Voltage Method) |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Resolution | 0.001 ppm / 0.01 ppm |
| Accuracy | ±2% of Full Scale |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 selectable) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (≤500 Ω, 0.1% FS), RS485 Modbus RTU |
| Relay Outputs | 2 programmable SPDT relays (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Alarm Logic | Dual independent Hi/Lo setpoints with hysteresis |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Electrochemistry |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | -10 to 130 °C (NTC10K or PT1000 sensor input) |
| Operating Temperature | -10 to 70.0 °C |
| Storage Temperature | -20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or Optional 24 VDC |
| Output | Dual Isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω) |
| Cleaning Control Output (interval | 0.1–1000 h |
| duration | 1–1000 s) |
| Alarm Outputs | Two Independent Hi/Lo Setpoints with Adjustable Hysteresis |
| Enclosure Rating | IP65 |
| Dimensions | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Mounting Options | Wall-Mount, Pipe-Mount, Panel-Mount |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Electrochemistry |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale |
| Resolution | 0.001 ppm (low range), 0.01 ppm (high range) |
| Temperature Compensation | –10 to 130 °C (NTC10K or PT1000 sensor selectable) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or 24 VDC optional |
| Output | Dual isolated 4–20 mA (0.1% FS accuracy, max loop resistance 500 Ω) |
| Cleaning Control | Adjustable cleaning interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |
| Mounting Options | Wall-mount, pipe-mount, panel-mount |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PM8202CL |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Constant-Voltage Detection |
| Measured Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Ozone |
| Range | 0.00–20.00 ppm / 0.00–200.00 ppb |
| Accuracy | ±2% of Full Scale (F.S.) |
| Resolution | 0.001 ppm / 0.01 ppm |
| Temperature Compensation | –10 to +130 °C (NTC10K or PT1000 sensor compatible) |
| Operating Temperature | –10 to +70.0 °C |
| Storage Temperature | –20 to +70.0 °C |
| Display | Backlit Graphic LCD (Chinese/English Switchable) |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or Optional 24 VDC |
| Output | Dual Isolated 4–20 mA (0.1% F.S., max. loop resistance 500 Ω), RS485 Modbus RTU |
| Relay Outputs | 2 programmable Hi/Lo alarms (5 A / 250 VAC / 30 VDC) |
| Cleaning Control | Adjustable interval (0.1–1000 h) and duration (1–1000 s) |
| Enclosure Rating | IP65 |
| Dimensions (W×H×D) | 144 × 144 × 108 mm |
| Panel Cutout | 138 × 138 mm |
| Weight | 0.87 kg |