Truelab
Filter
Showing 151–171 of 171 results
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | VFD-2000 |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Lyophilization Area | 0.2 m² |
| Ultimate Vacuum | < 13 Pa |
| Condenser Temperature | < −70 °C |
| Water Capture Capacity | 4 kg/24 h |
| Dimensions (W×D×H) | 652 × 700 × 1100 mm |
| Power Supply | 220 V, 50 Hz, 1800 W |
| Shelf Configuration | 2 Shelves, 77 mm Spacing, 390 × 275 mm Tray Size |
| Programmable Cycles | 20 Programs × 20 Steps Each |
| Data Interface | USB (Standard), RS-485 (Optional) |
| Refrigeration System | Dual-Compressor Cascade Cooling |
| Chamber Design | Vertical Front-Opening, In-Situ Freezing & Drying |
| Gas Inlet Valve | Imported Solenoid Valve for N₂ or Inert Gas Purging |
| Display | Large LCD with Real-Time Curve + Numeric Monitoring (Chamber Temp, Shelf Temp, Condenser Temp, Vacuum Level, Elapsed Time) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | Vortex-50 |
| Speed Range | 500–2500 ±50 rpm (at 2500 rpm) |
| Oscillation Mode | Vortex |
| Drive Mechanism | Adjustable Speed |
| Amplitude | 4 mm |
| Display | LED Digital |
| Timer Range | 1 s – 9999 min |
| Capacity | 50 tubes |
| Platform Dimensions | 312 × 185 mm |
| Overall Dimensions | 425 × 250 × 480 mm |
| Net Weight | 22 kg |
| Load Capacity | 5 kg |
| Power | 60 W |
| Voltage/Frequency | 220 V, 50 Hz |
| Housing Material | Aluminum Alloy |
| Standard Fixture | 12 mm foam tube holder with tray pad |
| Optional Fixtures | V50-A to V50-F & V50-H (for 10–50 mm tubes and centrifuge tubes) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model Series | WGZ-1 / WGZ-200 / WGZ-800 |
| Instrument Type | Portable turbidimeter |
| Measurement Principle | 90° scattered light detection (ISO 7027 compliant) |
| Measurement Range | WGZ-1: 0–100 NTU & 0–200 NTU |
| WGZ-200 | 0–20 NTU & 0–200 NTU |
| WGZ-800 | 0–200 NTU & 0–800 NTU |
| Minimum Readout | WGZ-1: 0.1 NTU |
| WGZ-200 | 0.01 NTU |
| WGZ-800 | 0.1 NTU |
| Basic Error | ±2.5% F.S. (WGZ-1) |
| Repeatability | ≤1% |
| Zero Drift | ±0.5% F.S. (equivalent to ±0.2 NTU for WGZ-1/WGZ-800 |
| Operating Temperature | 0–25 °C |
| Resolution | 0.2 NTU (typical display resolution across series) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | WGZ-2-XJ |
| Minimum Readout | 0.01 MCF |
| Measuring Range | 0–6 MCF |
| Basic Error | ±5% F.S. (McFarland Units) |
| Repeatability | ≤1.5% |
| Display | Backlit LCD with Microprocessor Control |
| Interface | RS232 Serial Port |
| Light Source | High-Intensity Stable LED (Rated Lifetime: 100,000 hours) |
| Data Storage | Internal Clock-Synchronized Memory for Calibration Values and Measurement Logs |
| Measurement Modes | Auto-Balanced Reading, Timed-Acquisition, Averaging Mode for Unstable Samples |
| Optical System | Precision Aligned Path with Chromatic Compensation |
| Compliance | Designed to support GLP-compliant workflows in microbiological water testing |
| Key | Brand: Truelab |
|---|---|
| Origin | Shanghai, China |
| Model Series | WGZ-200A, WGZ-2A, WGZ-2, WGZ-3, WGZ-3A, WGZ-100 |
| Type | Portable Turbidimeter |
| Measurement Principle | 90° Nephelometric Scattering |
| Range | 0–1000 NTU (model-dependent) |
| Resolution | 0.001–0.01 NTU |
| Accuracy | ±2% F.S. |
| Repeatability | ≤1% |
| Zero Drift | ±0.5% F.S. (at 0.02–0.1 NTU) |
| Operating Temperature | 25 °C ambient |
| Compliance | ISO 7027, ASTM D6508, USP <241>, GLP-ready architecture |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | WI22-0201 Octo-Configurable Kit |
| Price Range | USD 0.15 – 150.00 |
| Material | 316L Stainless Steel (Needles & Housing), Medical-Grade Polypropylene (Adapters) |
| Certifications | ISO 13485–compatible manufacturing environment |
| Pressure Test | Pre-shipped hydrostatic leak test at 0.6 MPa |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | WRS-1A |
| Melting Point Range | Ambient to 300 °C |
| Temperature Resolution | 0.1 °C |
| Linear Heating Rates | 0.2, 0.5, 1.0, 1.5, 2.0, 3.0, 4.0, 5.0 °C/min (8 selectable) |
| Accuracy | ±0.5 °C below 200 °C |
| Sample Capacity | 3 positions (simultaneous) |
| Display | Backlit LCD with real-time melting curve visualization |
| Interface | RS232 for data export |
| Dimensions | 398 × 280 × 170 mm |
| Weight | 11 kg |
| Brand | Truelab |
|---|---|
| Model | X2E-290 |
| Capacity | 202 L |
| Internal Dimensions (W×D×H) | 598 × 645 × 524 mm |
| External Dimensions (W×D×H) | 600 × 695 × 642 mm |
| Shelf Quantity | 2 pcs |
| Shelf Size | 555 × 580 × 20 mm |
| Humidity Control Range | ≤5% RH |
| Humidity Accuracy | ±3% RH |
| Temperature Accuracy | ±1°C |
| Control System | Humidity Manager V2 (fully automatic, with digital temperature/humidity curve logging) |
| Power Supply | 220 V |
| Avg. Power Consumption | 55 W |
| Max. Power Consumption | 155 W |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | XYN-10LMGC |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | 10 L/min (adjustable up to ≥10 L/min) |
| Output Pressure | ≥7.5 bar |
| Nitrogen Purity | >99.9% |
| Dew Point | <−45 °C |
| Air Intake Capacity | 150 L/min |
| Power Consumption | 720 W |
| Noise Level | ≤54 dB(A) @ 1 m |
| Dimensions (W×D×H) | 400 × 450 × 1280 mm |
| Net Weight | <35 kg |
| Pressure Stability | ≤0.03 MPa |
| Filtration Stages | 4-stage (coalescing, refrigerated drying, ultra-fine particulate <0.01 µm, oil-free & phthalate-free) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | Y70 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–10 °C/min |
| Temperature Repeatability | ±0.1 °C (at 0.1 °C/min) |
| Temperature Accuracy | ±0.3 °C (up to 100 °C) |
| Capillary Dimensions | OD 1.4 mm, ID 1.0 mm, L 100 mm (dual-open) |
| Sample Capacity | 2 samples per run |
| Temperature Resolution | 0.1 °C |
| Compliance | SNT 0801.5–1999, GB/T 24892–2010, GB/T 12766–2008 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | YC-015 / YC-1800 |
| Max Feed Rate | 2000 mL/h |
| Inlet Temperature Range | 30–300 °C |
| Outlet Temperature Range | 30–140 °C |
| Particle Size Distribution | Normal (Dv50 ≈ 1–10 µm) |
| Drying Time | 1.0–1.5 s |
| Temperature Control Accuracy | ±1 °C (PID) |
| Noise Level | <60 dB(A) |
| Power Supply | 3 kW / 220 V (YC-015) |
| Dimensions | 1200 × 650 × 500 mm (H×L×W) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-1 |
| Wavelengths | 254 nm and 365 nm |
| Type | Portable (handheld) |
| Wavelength Configuration | Dual-band UV |
| Compliance | CE-marked for laboratory use |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Safety Features | UV-blocking acrylic shield, automatic shutoff timer (optional), thermal protection circuit |
| Certifications | ISO 9001 manufacturing quality system |
| Intended Use | Non-clinical laboratory fluorescence visualization and documentation |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZF-20C / ZF-20D |
| UV Wavelengths | 254 nm & 365 nm (dual-band, independently switchable) |
| UV Lamp Configuration | 2 × 6 W @ 254 nm + 2 × 6 W @ 365 nm |
| Filter Dimensions | 150 mm × 70 mm |
| Filter UV Transmission | ≥20% at designated wavelengths |
| Input Voltage | AC 220 V, 50 Hz |
| Power Consumption | ≤22 W (total) |
| Lamp Lifetime | ≈500 h |
| Enclosure Type | Fully enclosed darkroom with integrated electronic ballast ignition |
| Portability | Benchtop portable design (hand-carried form factor) |
| Compliance | Designed for laboratory-grade qualitative fluorescence visualization in accordance with standard molecular biology workflows |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model Variants | ZF-7A (254 nm + 365 nm), ZF-7B (365 nm only), ZF-7C (254 nm only), ZF-7D (310 nm only) |
| Input Voltage | 220 V AC, 50 Hz |
| Rated Power | 16 W |
| UV Filter Dimensions | 50 mm × 150 mm |
| UV Lamp Quantity | 16 lamps |
| UV Wavelength Options | 254 nm, 310 nm, 365 nm |
| Device Form Factor | Handheld / Portable |
| Compliance | CE-marked for laboratory use, conforms to IEC 61010-1 safety standards for electrical equipment for measurement, control, and laboratory use |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZHWY-110X30 |
| Timing Range | 0–500 h |
| Oscillation Frequency | 20–180 rpm |
| Oscillation Amplitude | 16 mm (factory-set) or 24 mm (configurable) |
| Temperature Range | Ambient to 99.9 °C |
| Temperature Uniformity | ±0.2 °C at 37 °C / 100 rpm |
| Temperature Resolution | ±0.1 °C |
| Tray Quantity | 1 |
| Power | 1600 W (ZHWY-110X30) / 2300 W (ZHWY-110X50) |
| Input Voltage | AC 220 V, 50/60 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZHWY-111/211B/C/D/E |
| Timer Range | 0–500 h |
| Oscillation Frequency | 30–300 rpm |
| Amplitude | 26 mm (circular) / 0–50 mm (reciprocating, ZHWY-F variants) |
| Temperature Range | 4–60 °C (ZHWY-211 series) or RT+5–60 °C (ZHWY-111 series) |
| Number of Shaking Platforms | 1 or 2 (model-dependent) |
| Platform Dimensions | up to 940 × 584 mm |
| Chamber Volume | 168–286 L |
| Temperature Uniformity | ≤ ±1 °C at 37 °C |
| Temperature Stability | ≤ ±0.5 °C at 37 °C |
| Temperature Resolution | 0.1 °C |
| Frequency Accuracy | ±1 rpm |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZJ-250 |
| Stirrer Type | Electric Vacuum Stirrer |
| Max. Mixing Volume | 1000 mL |
| Speed Range | 12–1735 rpm (3 selectable ranges with mechanical gear reduction) |
| Temperature Control Range | −25 °C to 120 °C |
| Power Options | 40 W / 60 W / 90 W |
| Torque Output | Up to 32.5 kg·cm (at 12 rpm, 90 W variant) |
| Dimensions | 380 × 290 × 580 mm |
| Net Weight | 13.5 kg |
| Input | 220 V~, 50 Hz |
| Sample Capacity | 50–1000 mL |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | ZNHW-100 to ZNHW-10000 |
| Heating Power | 250 W |
| Max Operating Temperature | 250 °C |
| Temperature Uniformity | ±10 °C across heating zone |
| Heating Surface Diameter | 200 mm |
| Heating Zone Diameter | 200 mm |
| Display | Dual-line LED digital display (setpoint & actual temperature) |
| Control Method | PID algorithm with thermocouple feedback |
| Safety Features | Thermocouple break protection, over-temperature cutoff |
| External Probe Compatibility | Yes (dual-sensor mode: mantle surface + vessel internal temperature) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | ZYC0004B, ZYC0012B, ZTC0022B, ZYC0030B, ZYC0045B, ZYC0060B, ZYC0090B |
| Construction | 1.0 mm+ cold-rolled steel with continuous spot welding |
| Door Mechanism | Three-point联动 lock system, 180° full-opening door with dual-key access |
| Finish | Lead-free electrostatic epoxy powder coating (interior & exterior) |
| Compliance | OSHA 29 CFR 1910.106, NFPA 30, FM Approval Standards |
| Grounding | Integrated static grounding port per OSHA requirements |
| Spill Containment | 50 mm high leak-proof sump |
| Ventilation | Dual flame-arresting vents with self-closing dampers |
| Color | Standard safety blue |
| Optional Accessory | Polypropylene (PP) spill trays |
| Certifications | Designed for GLP-compliant laboratory environments |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | UL90-GSM |
| Price | USD 570 (approx.) |
| Temperature Range | −90 °C to +40 °C |
| Temperature Accuracy | ±0.5 °C to ±0.8 °C |
| Temperature Resolution | 0.1 °C |
| Memory Capacity | 14,848 data points (expandable to 31,104) |
| Logging Interval | 2 seconds to 24 hours (user-configurable) |
| Power Supply | 12 V DC input with built-in rechargeable lithium battery (7-day backup during power outage) |
| Communication Interface | USB 2.0 |
| Average Power Consumption | ≤0.24 W |
| Alarm Triggers | Temperature out-of-range, power failure, configurable SMS alert interval (default 10 min) |
| SMS Recipients | Up to 3 mobile numbers |
| Network Compatibility | GSM only (not compatible with CDMA or LTE-only SIMs) |
| Operating Environment | −20 °C to +70 °C |
| Compliance | CE-marked for industrial environmental monitoring |
| [Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | LHH Series |
| Internal Volume | 2–250 m³ (customizable) |
| Temperature Range | 0–65°C |
| Humidity Range | 40–95% RH (down to ≤20% RH with optional dehumidification) |
| Temp. Uniformity | ≤±2.0°C |
| Temp. Fluctuation | ±0.5°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | 1–2°C/min |
| Cooling Rate | 0.5–1°C/min |
| Control System | BTHC (Balanced Temperature & Humidity Control) with PID algorithm |
| Display | Color TFT LCD touchscreen (Chinese/English switchable) |
| Programs | Up to 100 user-defined/storable cycles |
| Sensor Inputs | PT100 (temperature), capacitive humidity sensor |
| Communication | RS-232C, RS-485 |
| Power Supply | AC 380 V ±10%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Operating Ambient | +5 to +35°C |
| Compliance Support | IQ/OQ/PQ qualification packages available |
| Optional Accessories | UV sterilization module, programmable light intensity control (0–10,000 lux), wired/wireless alarm systems, USB/RS-485 data logging, third-party metrology report (Shanghai Accredited Lab, ¥1500)] |