| Model | MTN-2800W (12/24/40-position) |
| Heating Method | Water Bath |
| Temperature Range | RT + 5°C to 100°C |
| Temperature Stability | ±0.1°C |
| Tube Diameter Compatibility | 10–15 mm |
| Nitrogen Flow Rate | 0–10 L/min (adjustable per channel) |
| Heating Power | 350 W |
| Heating Block Height | 70 mm |
| Display | Dual digital displays for set/actual temperature + dual timers (set time & countdown) |
| Over-Temperature Protection | Activated at set temperature + 5°C |
| Timer Range | 10 min – 99 h 59 min |
| External Dimensions (W×H×D, excluding support rod) | 240 × 130 × 215 mm |
| Heating Block Dimensions (W×H×L) | 150 × 70 × 95 mm |
| Certifications | Compliant with GB/T 26572–2011 (Electrical Safety for Laboratory Equipment), RoHS-compliant construction |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NDJ-1 Ultra-Low Viscosity |
| Instrument Type | Benchtop Fixed Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.1–2,000,000 mPa·s |
| Speed Settings | 6, 12, 30, 60 rpm (manual gear shift) |
| Accuracy | ±5% (for Newtonian fluids) |
| Spindle Set | #0, #1, #2, #3, #4 |
| Gear Ratio Units | I (1:1), II (1:10, 1:100), III (×0.1, ×0.2, ×0.4, ×0.5) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NDJ-4 High-Viscosity |
| Instrument Category | Rotational Viscometer (Analog, Spindle-Based) |
| Form Factor | Benchtop (Non-Portable) |
| Operating Environment | Ambient Temperature (15–30 °C) |
| Viscosity Range | 10–2,000,000 mPa·s |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Spindles | No. 1–4 (standard) |
| Accuracy (Newtonian fluids) | ±5% full scale |
| Display | Analog dial with mechanical pointer |
| Dimensions | 275 × 265 × 445 mm |
| Weight | ~12.5 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-79 |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–1×10⁶ mPa·s |
| Accuracy | ±5% (for Newtonian fluids) |
| Rotational Speeds | 7.5 / 75 / 750 rpm |
| Measuring Systems | Three interchangeable spindles (Units I, II, III) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 170 × 140 × 440 mm |
| Weight | 15 kg |
| Operating Environment | Ambient temperature (no integrated temperature control) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-8S |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 0.1–2,000,000 mPa·s (with appropriate spindle and speed selection) |
| Speed Settings | 6, 12, 30, 60 rpm |
| Spindles | LV#1–#4 (standard set) |
| Display | Digital LCD with bilingual (English/Chinese) interface |
| Measurement Accuracy (Newtonian fluids) | ±5% of full scale |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | Ambient temperature (10–35 °C), <80% RH non-condensing |
| Compliance | Designed per GB/T 2794–2013 (China National Standard for viscometer calibration), compatible with ISO 2555 and ASTM D2196 test methodologies |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NMS-1 |
| Price Range | USD 1,400 – 2,800 |
| Funnel Diameter | 60 mm |
| Funnel Speed Range | 0–650 rpm |
| Winding Drum Speed | 0.01–10 rpm |
| Reciprocating Stroke | ≤50 mm |
| Reciprocating Speed | 0.01–10 mm/s |
| Yarn Component Width | 100 mm |
| Max. Yarn Spool Diameter | 100 mm |
| Weight | 4 kg |
| Max. Power Consumption | 45 W |
| Supply Voltage | 24 V DC |
| Operating Temperature | 5–45 °C |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | OS-20 / OS-30 |
| Timer Range | 1 min – 99 h 59 min |
| Oscillation Frequency | OS-20: 50–300 rpm |
| OS-30 | 50–250 rpm |
| Orbit Diameter | 20 mm (OS-20), 30 mm (OS-30) |
| Load Capacity | 2 kg |
| Temperature Range | 4–45 °C |
| Platform Quantity | 1 |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PEC-1 |
| Price Range | USD 125 – 140 |
| Electrode Spacing | 0–80 mm |
| Electrode Length | 100 mm |
| Electrode Width | 10 mm |
| Overall Dimensions (L×W×H) | 120 × 120 × 90 mm |
| Electrode Material | Oxygen-Free Copper (OFHC) |
| Electrode Holder & Base Material | Polypropylene (PP) |
| Surface Finish | Sharp-edged collection faces |
| Alignment Tolerance | < 0.1° deviation over full length |
| Weight | ~1.3 kg |
| Brand | Truelab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | E2-TS / E2-TH / E2-TF / E2-TJ |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Purified Water Grade | ASTM Type I (Ultra-Pure), GB/T 6682-2008 Grade I |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb (E2-TS/E2-TF), <5 ppb (E2-TH), <10 ppb (E2-TJ) |
| Endotoxin | <0.001 EU/mL (E2-TS/E2-TF), <0.002 EU/mL (E2-TH) |
| Microbial Count | <0.1 CFU/mL |
| Particles (>0.2 µm) | <1 CFU/mL |
| RNase | <0.01 ng/mL (E2-TS/E2-TF) |
| DNase | <4 pg/µL (E2-TS/E2-TF) |
| Feed Water Requirement | Municipal tap water, TDS <200 ppm, 5–45 °C, pressure 1.0–4.0 kgf/cm² |
| Flow Rate | 5–40 L/h (adjustable), instantaneous output 1.5–2.0 L/min (with pressurized tank) |
| Dimensions (W×D×H) | 500 × 400 × 580 mm |
| Weight | ~38 kg |
| Power | 220 VAC, 50 Hz, 50–80 W |
| Noise Level | <50 dB(A) |
| Certifications | NSF-certified tubing and fittings, RO membrane: Dow FilmTec™, UV lamp: dual-wavelength (185/254 nm), low-voltage DC control architecture (24 VDC), IPX1-rated enclosure |
| Brand | Truelab |
|---|---|
| Model | PrimeHisto XE |
| Origin | Shanghai, China |
| Slide Format | 25 × 75 mm (1 × 3 in) |
| Scan Area | 24.3 × 36.5 mm |
| Optical Resolution | 10,000 dpi |
| Dynamic Range | 3.8 OD |
| Illumination | Transmissive White LED |
| Image Formats | TIFF, JPEG, BMP |
| Dimensions | 260 × 155 × 70 mm |
| Power Supply | 100–240 V AC, 12 V / 1.5 A adapter |
| OS Compatibility | Windows XP–10, macOS 10.5+ |
| Software | HistoView v3.x (driver-integrated acquisition & post-processing suite) |
| Optional Accessory | Rotatable Polarizer Mount for geological thin-section analysis |
| Brand | Truelab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QM-3SP |
| Instrument Type | Planetary Ball Mill |
| Sample Suitability | Hard and brittle materials |
| Feed Size | ≤10 mm (soil), ≤3 mm (other materials) |
| Final Particle Size | ≤0.1 µm |
| Batch Grinding Capacity | 0.4 L |
| Drive Mechanism | Gear-driven transmission |
| Rotation Ratio (Revolution | Rotation): 1:2 |
| Rotational Speed (Jar Rotation) | 0–600 rpm |
| Control System | Frequency-conversion stepless speed regulation, programmable timing, bidirectional rotation control, auto-shutdown |
| Continuous Operation Time (Full Load) | Up to 48 h |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Truelab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QM-DY4 |
| Instrument Type | Planetary Ball Mill |
| Sample Suitability | Hard & Brittle Materials |
| Feed Size | ≤10 mm (brittle), ≤3 mm (other materials) |
| Final Particle Size | ≤0.1 µm |
| Batch Grinding Capacity | 4 L |
| Operating Temperature Range | −40 °C to 20 °C |
| Nitrogen Consumption (0–10 °C) | 4–5 L/h |
| Dimensions (Mill) | 750 × 480 × 520 mm |
| Weight (Mill) | 130 kg |
| Planetary Speed (4L) | 265 rpm (revolution), 530 rpm (rotation) |
| Drive | Gear-driven |
| Control | Microprocessor-based programmable timer with automatic forward/reverse cycling and shutdown |
| Cooling Method | Continuous liquid nitrogen injection into insulated grinding chamber |
| Brand | Truelab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | QM-WX4 |
| Instrument Type | Planetary Ball Mill |
| Sample Suitability | Hard & Brittle Materials |
| Feed Size | ≤10 mm (soil), ≤3 mm (other materials) |
| Final Particle Size | ≤0.1 µm |
| Batch Grinding Capacity | 4 L (total, 4 × 1 L jars) |
| Rotation Ratio (Revolution | Rotation): 1 : 2 |
| Rotational Speed (Jar Rotation) | 0–530 rpm (for 4 L jars) |
| Speed Control | Stepless Electronic Speed Regulation with Programmable Timer, Auto Forward/Reverse Cycling, and Auto Shut-off |
| Continuous Operation Time (Full Load) | Up to 48 h |
| Jar Configuration | Four horizontally mounted grinding jars, symmetrically arranged on a vertical drive plate |
| Optional Accessories | Vacuum-sealed grinding jars (50–500 mL capacity) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | R-1001 |
| Capacity | 0.9 L |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 20–180 rpm |
| Bath Temperature Range | Ambient +5°C to 95°C |
| Temperature Control Accuracy | ±1.5°C (nominal), 0.1°C resolution |
| Condenser Surface Area | 0.126 m² |
| Sealing | Dual PTFE + FKM O-rings |
| Rotating Flask Tilt Angle | 15°–45° |
| Bath Material | 06Cr19Ni10 stainless steel (Φ254 mm × 130 mm) |
| Glassware | DIN ISO 3585 borosilicate 3.3 |
| Power Supply | 220–240 V~, 50/60 Hz |
| Heating Power | 1050 W |
| Total Power Consumption | 1080 W |
| IP Rating | IP20 |
| Max. Altitude | 2000 m |
| Operating Environment | 5–35°C, ≤70% RH |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | R-3001 |
| Capacity | 2 L |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 10–280 rpm |
| Bath Temperature Range | 20–180 °C |
| Temperature Control Accuracy | ±1 °C |
| Condenser Cooling Area | 0.126 m² |
| Brand | Truelab |
|---|---|
| Origin | Shanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RF-6000A |
| Dimensions (W×D×H) | 230 × 150 × 375 mm |
| Liquid Capacity | 1500 mL |
| Dispensing Volume per Cycle | Adjustable 1–5 mL |
| Sensing Distance | 8–250 mm |
| Power Supply | AC 100–240 V, 50/60 Hz, ±10% |
| Power Consumption | <60 W |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80% RH |
| Safety Class | Class I, Type B |
| Net Weight | 3.6 kg |
| Sensor Type | German-made infrared proximity sensor with ambient light immunity |
| Reservoir Material | Food-grade PE (polyethylene), hermetically sealed |
| Display | LED liquid-level indicator (full: 1500 ±10 mL |
| low | 100 ±15 mL) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RRC-1 |
| Price | USD 1,400 (approx.) |
| Base Web Width | 100 mm |
| Speed Range | 0.01–10 rpm |
| Linear Velocity Range | 0.13–52.44 mm/s |
| Drum Diameter Compatibility | 25–100 mm |
| Roller Height Adjustment | 0–24 mm |
| Max Power Consumption | 45 W |
| Supply Voltage | 24 V DC |
| Frame Material | PP Polypropylene |
| Roller & Mount | 304 Stainless Steel |
| Grounding Plate | Anodized Aluminum |
| Net Weight | 7.5 kg |
| Cable | 1 m, 5-pin aviation connector |
| Operating Temperature | 5–45 °C |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SB-100DT / SB-3200DT / SB-5200DT |
| Tank Capacity | 4.5 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W |
| Adjustable Power | Yes |
| Temperature Range | Ambient to 80 °C |
| Timer Range | 1–99 min |
| Sound-Dampening Lid | Included |
| Manual Drain | Yes |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SCY-3 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Detection Range | 0–2% (displayed as % vol when ≥1% |
| Accuracy | ±1.0% of full scale |
| Operating Temperature | 0–45 °C |
| Relative Humidity Limit | <90% RH (non-condensing) |
| Interference Restrictions | Excludes CH₄, SO₂, H₂S, Cl₂, NH₃, and other corrosive or spectrally overlapping gases |
| Power Supply | AC 220 V, 50–60 Hz / DC 12 V (rechargeable Ni-MH battery onboard) |
| Power Consumption | ≤3 W (DC mode) |
| Dimensions | 210 × 90 × 230 mm |
| Weight | 2.0 kg |
| Response Time (t₉₀) | ≤50 s |
| Display | Backlit Chinese-language LCD |
| Data Output | Integrated thermal printer (real-time printout of measurement records) |
| Auto-Sampling Interval | Programmable timed measurement cycles |
| Compliance | Designed per IEC 61000-6-3 (EMC), GB/T 18204.2–2014 (Chinese standard for CO₂ detection in indoor air), and general industrial safety requirements for portable gas analyzers |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SCY-3A |
| Measurement Range | 0–1.5% (w/w) |
| Accuracy | ±2.5% |
| Display | Chinese LCD interface |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | ≤15 W |
| Dimensions | 450 mm × 305 mm × 550 mm (H) |
| Weight | 15 kg |
| Data Storage Capacity | 63 entries per sample type (beer + soft drinks) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SHB-III |
| Instrument Type | Circulating Water Vacuum Pump |
| Pump Type | Oil-Free |
| Ultimate Vacuum | 0.098 MPa (abs) |
| Suction Rate (per head) | 10 L/min |
| Motor Power | 150 W |
| Flow Rate (cooling water circuit) | 80 L/min |
| Max Head | 10 m |
| Reservoir Capacity | 15 L |
| Dimensions (L×W×H) | 385 × 280 × 420 mm |
| Weight | 15 kg |
| Housing Material | Engineering Plastic |
| Pump Body Material | 1Cr18 Stainless Steel |
| Power Supply | 220 V / 50 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SLQ-6 |
| Sample Capacity | 6 positions |
| Sample Mass Range | 0.5–3 g |
| Measurement Range | 0–100% (w/w) |
| Accuracy | Relative deviation ≤4%, Parallel deviation ≤0.4% |
| Total Cycle Time | ≤90 min (acid digestion: 30 min, alkaline digestion: 30 min, filtration & rinsing: ~30 min) |
| Heating System | Six independent semi-spherical ceramic heating elements with individual temperature control per crucible |
| Temperature Range | Ambient to 400 °C |
| Sealing Mechanism | Dual-layer PTFE isolation gasket (top and bottom) |
| Rated Power | 2 kW |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Dimensions (W×D×H) | 570 × 470 × 750 mm |
| Weight | 30 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | Smart-MS |
| Stirring Capacity | 2 L (H₂O) |
| Speed Range | 0–1250 rpm |
| Temperature Control Range | Ambient to 40 °C |
| Plate Diameter | Ø 145 mm |
| Plate Material | Engineering Plastic |
| Dimensions (D × H) | Ø 185 × 75 mm |
| Weight | 0.65 kg |
| Power Supply | 220 V, 50/60 Hz |
| Operating Environment | 5–40 °C, ≤80% RH |
| Stir Bar Included | 30 × 8 mm PTFE-coated |
| Speed Control | Continuous Analog Adjustment |
| Interface | None |
| Compliance | CE-marked per IEC 61010-1 for laboratory electrical safety |
| Brand | Truelab |
|---|---|
| Origin | Germany |
| Model Variants | S2-DS, S2-DH, S2-DF, S2-DJ |
| Feed Water Requirement | Deionized Water (≤3 µS/cm) |
| Product Water Grade | ASTM Type I / ISO 3696 Class 1 / GB/T 6682–2008 Grade I |
| Resistivity | 18.2 MΩ·cm @ 25 °C |
| Heavy Metals & Soluble Silica | <0.1 ppb |
| Total Organic Carbon (TOC) | <3 ppb (S2-DS/S2-DJ), <5 ppb (S2-DH), <10 ppb (S2-DF) |
| Endotoxin | <0.001 EU/mL (S2-DS/S2-DF), <0.002 EU/mL (S2-DH) |
| Bacteria | <0.1 CFU/mL |
| Particles (>0.2 µm) | <1 CFU/mL |
| RNase | <0.01 ng/mL (S2-DS/S2-DF) |
| DNase | <4 pg/µL (S2-DS/S2-DF) |
| Flow Rate | 10–90 L/h (adjustable), Instantaneous Output: 1.5–2.0 L/min |
| Dimensions (W×D×H) | 500 × 400 × 580 mm |
| Weight | ~38 kg |
| Power Supply | 220 V, 50 Hz, 50–80 W |
| Noise Level | <50 dB(A) |
| Conductivity Sensor Cell Constant | 0.01 cm⁻¹, Temp. Sensitivity: ±0.1 °C with Automatic Temperature Compensation |
| Safety | 24 VDC Low-Voltage Primary Power, NSF-Certified Tubing & Fittings, IPX4-Rated ABS Housing, Electrical/Water Separation Architecture |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SmartFiber-E |
| Price | USD 5,600 (FOB Shanghai) |
| Compliance | GB/T 5009.88–2008, GB/T 5413.6–2010, GB/T 9822–2008, GB/T 22494–2008, NY/T 1594–2008, AOAC 991.43, AACC 32–07, NMKL 157, ASP Method |
| Sample Throughput | 6 samples per run |
| Filtration Technology | Dual-mode SmartVacuumFilter™ with alternating positive/negative pressure |
| Crucible Type | Patented ground-glass fritted crucibles (G2, 40–100 µm pore size) |
| Filtration Speed | ≤3 min per 100 mL digestate |
| Precision | RSD <0.5% (n=6, certified reference material) |
| Software | Standalone control interface with audit trail logging |
| Accessories | G1–G5 fritted crucibles, 80–2800 mesh sieves, optional thermostatic shaker bath, standardized clamp kits |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature (15–30 °C) |
| Viscosity Range | 0.1–2,000,000 mPa·s |
| Speed Settings | 6 / 12 / 30 / 60 rpm |
| Rotor Set | L1–L4 (ISO/DIN-compatible spindles) |
| Display | Digital LCD with Dual-Language UI (English/Chinese) |
| Power Input | 110–240 V AC, 50/60 Hz |
| Accuracy (Newtonian Fluids) | ±2% of full scale |
| Viscosity Measurement Principle | Couette flow via rotating spindle in stationary sample cup |
| Compliance | Designed to meet ISO 2555, ASTM D2196, and GB/T 2794 standards for rotational viscosity testing |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SPH-103D |
| Timer Range | 0–500 h |
| Oscillation Frequency | 30–600 rpm |
| Orbit Diameter | Φ0–50 mm |
| Temperature Range | Ambient +5°C to 60°C |
| Platform Quantity | 1 |
| Control System | PID microprocessor with LCD dual-display (setpoint & real-time) |
| Drive Mechanism | Patented single-axis balanced drive |
| Cooling System | CFC-free R134a refrigerant |
| Heating Power | 150 W |
| Motor | AC induction, brushless, maintenance-free |
| Safety Features | Over-temperature/over-speed audiovisual alarm, independent thermal cutoff, lid-open stop, auto-restart after power recovery |
| Platform Size | 260 × 260 mm |
| Capacity | 9 × 100 mL or 4 × 250 mL flasks |
| Internal Chamber | 360 × 340 × 280 mm (W×D×H) |
| Net Weight | 31 kg |
| Power Supply | AC 200–240 V, 50–60 Hz |
| Compliance | CE-marked design principles |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Options | 10 cm × 10 cm, 15 cm × 15 cm, 20 cm × 20 cm, 25 cm × 25 cm, 30 cm × 30 cm platform variants |
| Customization | Available for non-standard dimensions and load requirements |
| Material | AISI 304 stainless steel (platform and structural components) |
| Load Capacity | Engineered for stable static loads up to 50 kg (varies by model and configuration) |
| Height Adjustment Range | Standard increments of 10–30 cm vertical travel |
| Surface Finish | Electropolished or passivated stainless steel for corrosion resistance and cleanroom compatibility |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SVF-1000 |
| Ultimate Vacuum Pressure | −0.08 MPa (200 mbar) |
| Positive Pressure Output | 0.10 MPa (1.0 bar) |
| Pressure Regulation Range | 0–0.1 MPa |
| Air Flow Rate | 25 L/min |
| Reverse-Blow Interval Setting | 0.1–99 s |
| Dimensions (L×W×H) | 270 × 310 × 240 mm |
| Weight | 5.5 kg |
| Power Consumption | 100 W |
| Input Voltage | 110–220 V, 50 Hz |
| Compliance | CE-marked design for laboratory use under IEC 61010-1 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SW-CJ-1BU / SW-CJ-1CU |
| Cleanliness Class | ISO Class 5 (Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Average Air Velocity | 0.3–0.6 m/s (adjustable) |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lx |
| Microbial Recovery | ≤0.5 CFU/plate·hr (φ90 mm Petri dish) |
| Vibration Half-Peak | ≤0.3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 0.15 kW (SW-CJ-1BU), 0.3 kW (SW-CJ-1CU) |
| Weight | 110 kg (SW-CJ-1BU), 200 kg (SW-CJ-1CU) |
| Work Area Dimensions | 910×480×570 mm (SW-CJ-1BU), 1570×480×570 mm (SW-CJ-1CU) |
| Overall Dimensions | 910×790×1380 mm (SW-CJ-1BU), 1570×790×1380 mm (SW-CJ-1CU) |
| HEPA Filter Specification | 820×600×100 mm ×1 (SW-CJ-1BU) |
| Fluorescent Lamp / UV Lamp | 20 W ×1 / 20 W ×1 (SW-CJ-1BU) |