Truelab
Filter
Showing 121–150 of 171 results
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SW-CJ-1FD |
| Airflow Type | Vertical Laminar Flow |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Average Air Velocity | 0.3–0.6 m/s (adjustable via 8-step digital control) |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lx |
| Microbial Recovery | ≤0.5 CFU/plate·hour (φ90 mm Petri dish) |
| Vibration Half-Peak | ≤3 µm (X/Y/Z axes) |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 0.3 kW |
| Net Weight | 200 kg |
| Work Area Dimensions | 1300 × 700 × 520 mm (W × D × H) |
| Overall Dimensions | 1460 × 700 × 1650 mm (W × D × H) |
| HEPA Filter Specification | 600 × 600 × 100 mm × 2 units |
| Fluorescent Lamp | 20 W × 1 |
| UV Germicidal Lamp | 20 W × 1 |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SX-IV |
| Instrument Type | Diaphragm Pump |
| Product Type | Oil-Free Pump |
| Vacuum Level | ≥80 kPa (ultimate vacuum: 20 kPa) |
| Air Displacement Rate | ≥20 L/min |
| Bottle Capacity | 1000 mL |
| Noise Level | ≤60 dB(A) |
| Rated Power | 110 VA |
| Dimensions (L×W×H) | 210 × 140 × 300 mm |
| Net Weight | 4 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model Variants | SX2-2.5-10T/TP, SX2-4-10T/TP, SX2-8-10T/TP |
| Maximum Temperature | 1000 °C |
| Operating Temperature Range | ≤950 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Rate | ≤50 °C/min (SX2-2.5 & SX2-8), ≤40 °C/min (SX2-4) |
| Chamber Dimensions (W×D×H) | 200×120×80 mm (2 L), 300×200×120 mm (7.2 L), 400×250×160 mm (16 L) |
| Heating Element | OCr25Al5 Fe-Cr-Al Alloy Wire |
| Power Supply | AC 220 V / 50 Hz (2.5 kW, 4 kW models) |
| Rated Power | 2.5 kW, 4 kW, or 8 kW |
| Insulation | High-Density Ceramic Fiber (Al₂O₃-SiO₂) |
| Control System | PID-Based Programmable Temperature Controller (30-segment or 60-segment ramp-soak profiles) |
| Compliance | JB/T 8195.7–2007 (Indirect Resistance Furnaces), GB/Z 18–2002 (Energy-Efficient Heat Treatment) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SX2-2.5-10N |
| Maximum Temperature | 1000 °C |
| Temperature Control Accuracy | ±2 °C |
| Rated Power | 2.5 kW |
| Heating Rate (to Max Temp) | ≤10 °C/min |
| Heating Element | High-Grade Resistance Wire (Ni-Cr Alloy) |
| Internal Chamber Dimensions | 120 × 200 × 80 mm (L×W×H) |
| Chamber Volume | 2 L |
| Voltage/Frequency | 220 V / 50 Hz |
| Furnace Liner Type | Refractory Brick |
| Enclosure Material | Stainless Steel (304) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SZC-C / SZC-D |
| Extraction Chamber Volume | 100 mL |
| Receiver Flask Volume | 500 mL |
| Temperature Range | 0–200 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Number of Channels | 6 |
| Power | 300 W |
| Voltage | 220 V ±10%, 50–60 Hz |
| Dimensions | 590 × 390 × 625 mm |
| Weight | 25 kg |
| Sealing Material | PTFE |
| Heating Method | Fully Enclosed Aluminum Alloy Heating Plate |
| Solvent Recovery Rate | ≥80% |
| Fat Recovery Rate | ≥99% (at reflux rate of 120 drops/min, coolant water ≤30 °C) |
| Precision | Relative deviation ≤3%, Parallel deviation ≤0.3% |
| Applicable Fat Content Range | ≥0.5% (food, feed, oilseeds, edible oils, and related products) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SZC-C |
| Instrument Type | Soxhlet Fat Extractor (not Kjeldahl Nitrogen Determinator — note correction per technical classification) |
| Automation Level | Manual (user-controlled heating, timing, and solvent management) |
| Fat Determination Range | ≥0.5% (crude fat in grains, foods, feeds, oils, and lipid products) |
| Sample Capacity | 6 positions simultaneously |
| Extraction Time | ~3.5 min per cycle (dependent on solvent boiling point and sample matrix) |
| Repeatability | Relative standard deviation ≤3% |
| Parallel Precision | ≤0.3% absolute difference between duplicates |
| Solvent Recovery Rate | ≥80% |
| Recovery Efficiency | ≥99% (under standardized conditions: reflux rate 120 drops/min, coolant inlet temperature ≤30 °C) |
| Heating Range | Ambient to 200 °C (digital PID-controlled) |
| Temperature Accuracy | ±1 °C |
| Heating Method | Fully enclosed aluminum alloy heating plate |
| Sealing Material | PTFE gaskets |
| Power Supply | 220 V ±10%, 50–60 Hz |
| Rated Power | 300 W |
| Dimensions (L×W×H) | 590 × 390 × 625 mm |
| Net Weight | 25 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | SZPT-3P |
| Material | 316L stainless steel (needle body & seat), medical-grade polypropylene (Luer adapter) |
| Dead Volume | Outer-Middle layer: 1.4 mL |
| Middle-Inner layer | 2.0 mL |
| Inner layer | 0.2 mL |
| Weight | ~300 g |
| Configurable needle gauges | e.g., 13G+16G+20G, 13G+18G+25G, 15G+20G+25G |
| Includes | 1× modular needle seat, 3× triple-needle sets, 10× 1/16″ tubing fittings, 10× small O-rings, 4× large O-rings, 4× Luer-lock adapters, 1× dual-purpose wrench, 1× metal mounting bracket |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TC-1000 |
| Drum Material | 304 Stainless Steel (Φ102 × L200 mm) |
| Base Material | Phenolic Resin (Bakelite), W450 × D200 × H20 mm |
| Motor | 57-step Hybrid Stepper Motor |
| Speed Range | 0–1000 rpm (±1 rpm accuracy) |
| Direction Control | Bidirectional (CW/CCW) |
| Overall Dimensions | W450 × D200 × H135 mm |
| Weight | 12 kg |
| Controller Compatibility | K11 Digital Speed Controller |
| Electrical Insulation | Class II, Bakelite base ensures high dielectric strength (>20 kV/mm) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TES ONE |
| Pricing | Available Upon Request |
| Collection Subsystem Options | Rotating Drum (High-Speed & Low-Speed), Rod Collector, Disk Collector |
| Needle Translation Stage Options | Adjustable Stroke Length |
| Needle Holder Configurations | Single-Needle, Multi-Needle, Coaxial-Needle |
| Control Unit Models | K21, K22, K11, K12, K13 |
| High-Voltage Power Supply Options | +30 kV, +50 kV, +80 kV, −30 kV, −50 kV |
| Syringe Pump Configurations | Single-Channel, Dual-Channel, Multi-Channel with Independent Flow Control |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TES-1 |
| Price Range | USD 2,800 – 7,000 |
| High-Voltage Power Supply | 0–+30 kV (adjustable), optional −30 kV |
| Dual-Channel Syringe Pump | 100 µL/h – 7.62 L/h, supports 1–60 mL syringes |
| Needle Traverse Range | 0–150 mm |
| Needle Speed | 0–1000 ±1 mm/min |
| Collector Rotation Speed | 120–3000 ±20 rpm (bidirectional) |
| Standard Collector | Balanced Rotating Drum (Φ100 × L200 mm) |
| Overall Dimensions (w/o collector) | 471 × 455 × 518 mm |
| Weight (w/o collector) | 25 kg |
| Safety Features | Emergency Stop, Grounding Protection, Overvoltage/Overcurrent/Arc-Fault Protection |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 60 W |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | TES-2 |
| Power Supply | ±30.0 kV (0.1 kV resolution) |
| Dual-Channel Syringe Pump | 100 µL/h – 7.62 L/h, max 60 mL syringe |
| Collector Speed | 0–600 ±1 rpm, reversible |
| Nozzle Traverse Range | 40–200 mm |
| Nozzle Travel Speed | 0–1000 ±1 mm/min |
| Tip-to-Collector Gap Adjustment | up to 180 mm |
| Temperature Control | RT–50 ±1.0 °C |
| Humidity Control | 20–80 ±3 %RH |
| Chamber Dimensions (w/d/h) | 833×466×995 mm (standalone), 833×466×1800 mm (with mobile base) |
| Weight | 110 kg (standalone), 125 kg (with base) |
| Total Power Consumption | 625 W |
| Safety Compliance | Integrated emergency stop, interlocked access door, full-system grounding, overtemperature protection, ESD-safe materials (PFA tubing, anti-static polymers, carbon-brush grounding rods) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | TES-4 |
| Voltage Output | ±30 kV (standard), optional ±60 kV |
| Collector | 304 stainless steel roller, servo-driven, max. 3000 rpm |
| Syringe Pump | Dual-channel, 2–60 mL compatibility, high-voltage rated |
| Motion Control | X (280 mm, manual), Y (180 mm auto-reciprocating, up to 3000 mm/min), Z (100 mm, manual) |
| Environmental Control | PID-controlled heating (far-infrared), condensation dehumidification, thermal evaporation humidification |
| Safety | Emergency stop, grounded conductive structure, explosion-proof tempered glass viewport, anti-static floor mat, UV germicidal lamp, observation lamp |
| Compliance | Designed for GLP-compliant electrospinning R&D environments |
| Software | Proprietary PLC-based electrospinning OS with real-time environmental logging, parameter recall, and audit-ready operation history |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T08 |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 0.8 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 35 W |
| Adjustable Power | No |
| Adjustable Temperature | No |
| Timer Function | No |
| Sound-Dampening Lid | Yes |
| Drain Port | No |
| Tank Dimensions (L×W×H) | 150 × 85 × 65 mm |
| External Dimensions (L×W×H) | 175 × 110 × 185 mm |
| Net Weight | 1.8 kg |
| Construction | SUS304 stainless steel tank and housing |
| Compliance | CE-marked for laboratory use in EU markets |
| Regulatory Context | Designed for non-sterile cleaning applications under GLP-aligned lab workflows |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | UC-T10 |
| Instrument Type | General-Purpose |
| Tank Capacity | 10.8 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 200 W |
| Adjustable Ultrasonic Power | Up to 300 W (via power boost mode) |
| Temperature Control Range | 20–80 °C |
| Timer Range | 1–20 min |
| Sound-Dampening Lid | Included |
| Drain Valve & Fill Port | Integrated |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T10D |
| Tank Capacity | 10.8 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 200 W |
| Heating Power | 300 W |
| Temperature Range | 0–80 °C |
| Timer Range | 1–99 min 59 sec |
| Built-in Drain Port | Yes |
| Sound-Insulating Lid | Yes |
| Construction | Full SUS304 Stainless Steel |
| External Dimensions | 330 × 270 × 310 mm |
| Internal Tank Dimensions | 300 × 240 × 150 mm |
| Net Weight | ~7.8 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T17 |
| Type | General-purpose ultrasonic cleaner |
| Tank Capacity | 17.3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 300 W |
| Adjustable Ultrasonic Power | Up to 400 W |
| Temperature Control Range | 20–80 °C |
| Heating Power | 400 W |
| Timer Range | 1–20 min |
| Sound-Dampening Lid | Included |
| Drain Port | Integrated |
| Tank Dimensions (L×W×H) | 355 × 325 × 150 mm |
| External Dimensions (L×W×H) | 360 × 330 × 310 mm |
| Net Weight | 13.5 kg |
| Construction | Full SUS304 stainless steel tank and housing |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments, compatible with GLP documentation workflows |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T17D |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 17.3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 400 W |
| Power Adjustment | Fixed at 400 W |
| Temperature Control Range | 0–80 °C |
| Timer Range | 1 min – 99 min 59 sec |
| Sound-dampening Lid | Yes |
| Drain Port & Fill Port | Yes |
| Tank Material | SUS304 stainless steel (seamless drawn) |
| External Dimensions | 360 × 330 × 310 mm |
| Internal Tank Dimensions | 355 × 325 × 150 mm |
| Heating Power | 400 W |
| Net Weight | 7.8 kg |
| Gross Weight | 13.5 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | UC-T2 |
| Instrument Type | General-Purpose |
| Tank Capacity | 2.1 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 50 W |
| Adjustable Power | No |
| Temperature Control | Ambient Only (No Heater) |
| Timer Range | 1–15 min |
| Sound-Dampening Lid | Yes |
| Drain Port | No |
| Construction | Stainless Steel (SUS304) Tank & Housing |
| External Dimensions | 190 × 170 × 220 mm |
| Internal Tank Dimensions | 150 × 140 × 100 mm |
| Net Weight | ~2.8 kg |
| Gross Weight | 3.1 kg |
| Packaging Dimensions | 208 × 208 × 262 mm |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T25 |
| Tank Capacity | 25.8 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 400 W |
| Adjustable Power Range | 0–500 W (heating + ultrasonics combined) |
| Temperature Control Range | 20–80 °C |
| Timer Range | 1–20 min |
| Sound-Dampening Lid | Included |
| Drain Valve | Integrated |
| Construction | Full SUS304 Stainless Steel Tank & Housing |
| Internal Dimensions | 530 × 325 × 150 mm |
| External Dimensions | 550 × 330 × 310 mm |
| Net Weight | 14.5 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T25D |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 25.8 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 500 W |
| Adjustable Power | Fixed at 500 W |
| Temperature Range | 0–80 °C |
| Timer Range | 1–99 min 59 sec |
| Sound-dampening Lid | Yes |
| Drain Port | Yes |
| Heating Power | 500 W |
| Inner Tank Dimensions | 530 × 325 × 150 mm |
| Overall Dimensions | 550 × 330 × 310 mm |
| Net Weight | 14.5 kg |
| Construction | Full SUS304 stainless steel tank and housing |
| Control System | Industrial-grade microcontroller with digital LED display |
| Rack | Stainless steel welded mesh basket included |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T3 |
| Tank Capacity | 3.3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W (fixed) |
| Timer Range | 1–20 min |
| Lid | Sound-dampening cover included |
| Drain | Manual valve |
| Construction | Stainless steel (SUS304) tank and housing |
| External Dimensions | 270 × 170 × 240 mm |
| Internal Tank Dimensions | 240 × 140 × 100 mm |
| Net Weight | ~3.45 kg |
| Heating Function | Not available |
| Power Adjustment | Not applicable (fixed 100 W) |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T34 |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 34.4 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 500 W |
| Adjustable Power | Fixed at 500 W |
| Temperature Range | 20–80 °C |
| Timer Range | 1–20 min |
| Sound-reducing Lid | Yes |
| Drain Port | Yes |
| Tank Dimensions (L×W×H) | 530 × 325 × 200 mm |
| Overall Dimensions (L×W×H) | 550 × 330 × 358 mm |
| Heating Power | 500 W |
| Construction | SUS304 stainless steel tank and housing |
| Net Weight | ~14.5 kg |
| Gross Weight | ~15.5 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T34D |
| Type | General-purpose ultrasonic cleaner |
| Tank Capacity | 34.4 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 500 W (adjustable in fixed-step mode) |
| Heating Range | 0–80 °C (digitally adjustable) |
| Timer Range | 1 min – 99 min 59 sec |
| Sound-dampening Lid | Included |
| Drain Port | Integrated |
| Tank Dimensions (L×W×H) | 530 × 325 × 200 mm |
| Overall Dimensions (L×W×H) | 550 × 330 × 358 mm |
| Net Weight | 14.5 kg |
| Gross Weight | 15.2 kg |
| Construction | Full SUS304 stainless steel tank and housing |
| Control System | Industrial-grade microcontroller with digital LED display |
| Basket | Welded stainless steel mesh rack |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T3D |
| Tank Capacity | 3.3 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power | 100 W |
| Heating Power | 100 W |
| Temperature Range | 0–80 °C |
| Timer Range | 1–99 min 59 sec |
| Adjustable Power | No |
| Adjustable Temperature | Yes |
| Adjustable Timer | Yes |
| Sound-Reducing Lid | Included |
| Drain Port | None |
| Construction | SUS304 Stainless Steel Tank & Housing |
| Control System | Industrial-Grade Microcontroller |
| Display | Digital LED (Time & Temperature) |
| Net Weight | ~5.5 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T7 |
| Type | General-purpose ultrasonic cleaner |
| Capacity | 7.0 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 150 W |
| Adjustable Power | Up to 300 W (heating only) |
| Temperature Control Range | 20–80 °C |
| Timer Range | 1–20 min |
| Sound-dampening Lid | Included |
| Drain Port | Yes |
| Tank Dimensions (L×W×H) | 300 × 155 × 150 mm |
| Overall Dimensions (L×W×H) | 330 × 180 × 310 mm |
| Net Weight | 5.45 kg |
| Construction | Full SUS304 stainless steel tank and housing |
| Stainless Steel Mesh Basket | Included |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UC-T7D |
| Tank Capacity | 7.0 L |
| Ultrasonic Frequency | 40 kHz |
| Ultrasonic Power Output | 150 W |
| Heating Power | 300 W |
| Temperature Range | 0–80 °C |
| Timer Range | 1–99 min 59 sec |
| Built-in Drain Port | Yes |
| Sound-Insulating Lid | Yes |
| Construction | Full SUS304 Stainless Steel |
| Internal Tank Dimensions | 300 × 155 × 150 mm |
| External Dimensions | 330 × 180 × 310 mm |
| Net Weight | 5.5 kg |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UPH-150 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 150–1800 W |
| Operating Frequency | 20–25 kHz |
| Sample Volume Capacity | 0.5–1200 mL |
| Temperature Control | Ambient (D-type variant includes microprocessor-controlled cooling) |
| Number of Samples Processed Simultaneously | 1 |
| Standard Horn Diameter | Φ6 mm |
| Optional Horn Diameters | Φ2, Φ3, Φ8, Φ10, Φ12, Φ15, Φ20, Φ22, Φ25, Φ28 mm |
| Duty Cycle Adjustment Range | 0.1–99.9% |
| Input Voltage | 220 V / 110 V, 50 Hz / 60 Hz |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UV-2800 / UV-2800PC |
| Optical Design | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 1.8 nm |
| Wavelength Accuracy | ±0.3 nm |
| Wavelength Repeatability | ±0.15 nm |
| Stray Light | ≤0.05% T |
| Baseline Flatness | ±0.001 A |
| Baseline Drift | ≤0.0005 A/h |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ±0.15% T |
| Display | 320 × 240 LCD |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | UV-752 |
| Wavelength Range | 200–1000 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2.0 nm |
| Wavelength Repeatability | ±1.0 nm |
| Stray Light | ≤0.5% T (at 220 nm and 340 nm) |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ±0.2% T |
| Baseline Drift | ±0.003 A/h |
| Detector | Photodiode Array |
| Optical Design | Dual-Beam |
| Wavelength Resolution | 0.1 nm step |
| Display | 128×64 LCD |
| Dimensions | 456 × 375 × 220 mm |
| Data Interface | USB |
| Software | UV-Solution Workstation |
| Brand | Truelab |
|---|---|
| Origin | Shanghai, China |
| Model | 1.5 cm Inner Diameter × 20 cm Length |
| Construction | Borosilicate Glass |
| Max Operating Pressure | 4 bar |
| Dead Volume | < 50 µL |
| Thread Standard | Female Luer Lock Inlet / Male Luer Lock Outlet |
| Optional Adapters | Adjustable-length LKB/Pharmacia-compatible conversion fittings (200 mm range) |
| Compliance | Designed for GLP-compliant lab workflows |