Chemical Analysis Instruments
Filter
Showing 5431–5460 of 10742 results
| Brand | Luchu Tech |
|---|---|
| Model | SEER |
| Type | Confocal Micro-Raman Spectrometer |
| Excitation Wavelengths | 532 nm / 785 nm |
| Raman Shift Range | SEER-532: 150–3600 cm⁻¹ |
| SEER-785 | 200–2500 cm⁻¹ |
| Spectral Resolution | SEER-532: 7 cm⁻¹ (25 µm slit, measured) |
| SEER-785 | 6 cm⁻¹ (25 µm slit, measured) |
| Wavenumber Accuracy | ±3 cm⁻¹ |
| Detector Integration Time | 9.5 ms – 20 s |
| SNR | 600:1 |
| Dynamic Range | 79,000:1 |
| Laser Linewidth | <0.1 nm |
| Laser Output | Multimode/Single-mode options at 100 mW or 500 mW |
| Microscope Spot Size | 3 µm @ 100× (532 nm, measured) |
| Objective Lenses | Interchangeable 10×/20×/50×/100× |
| Illumination | LED white-light coaxial illumination |
| Tube Lens Focal Length | 180 mm |
| Software | RudeerTek RamanSoft (Windows 32/64-bit, Win7/10/11) |
| Interface | USB 2.0 |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Detector Type | CCD Array |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.11–3.42 nm |
| Signal-to-Noise Ratio | 450:1 (full signal) |
| Dynamic Range | 2100:1 (single acquisition) |
| Stray Light | <1% |
| F-number | f/4 |
| Optical Design | Crossed Czerny-Turner |
| Slit Options | 10/25/50/75/100 µm |
| Pixel Array | 2048 × 64 pixels |
| Pixel Size | 14 µm × 14 µm |
| A/D Resolution | 16-bit |
| Integration Time | 2.4 ms – 10 s |
| Linearity | ≥0.998 |
| Interface | USB 2.0 Type-B, Digital I/O, SMA905 fiber port |
| Weight | 1.07 kg |
| OS Support | 32/64-bit Windows 7/10/11 |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GJY |
| Pricing | Upon Request |
| Brand | Luchu Technology |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | SLAK |
| Detector | CMOS linear array sensor (2048 × 1 pixels) |
| Spectral Range | 200–1100 nm |
| Optical Resolution (FWHM) | 0.3–7 nm |
| Signal-to-Noise Ratio | 320:1 |
| Dynamic Range | 1500:1 |
| Stray Light | <1% |
| Optical Design | Symmetrical Czerny-Turner |
| f-number | f/7 |
| Cooling | Uncooled |
| Interface | USB Type-C, Digital I/O |
| Fiber Connector | Standard SMA905 (customizable) |
| Dimensions | 95 × 68 × 25 mm |
| Weight | 195 g |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AHS-2036Plus |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Vial Heating Range | Ambient to 260 °C |
| Valve Temperature Control Range | Ambient to 260 °C |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 30 or 36 vials |
| Vial Size | 20 mL (customizable to 10 mL) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-800 |
| Instrument Type | Single-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temperature Range | 50–380 °C |
| Valve Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 220 °C |
| Cold Trap Temperature | −30 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Desorption Recovery Rate | >99% (compound-dependent) |
| Sample Position Count | 1 |
| Sample Tube Dimensions | ≤6.5 mm OD, ≥120 mm length |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ATDS-8100 |
| Instrument Type | Dual-stage thermal desorber |
| Automation Level | Semi-automatic |
| Primary Desorption Temp Range | 50–380 °C |
| Valve Injection Temp Range | Ambient to 260 °C |
| Transfer Line Temp Range | Ambient to 220 °C |
| Cryo-Trap Temp Range | –30 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Rate | >80% |
| Sample Position Count | 1 |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | 50–380 °C |
| Secondary Desorption Temp Range | 150–380 °C |
| Valve & Transfer Line Temp Range | Ambient to 260 °C / Ambient to 220 °C |
| Cryo-Trap Temp Range | −30 to 30 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Desorption Recovery Rate | ≥90% |
| Sample Positions | 20 |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry |
| Temperature Control Range | 0–450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 300 °C to 100 °C in ≤3.5 min (at 25 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min (7-program segments) |
| Carrier Gas Pressure Range | 0–970 kPa (7-program segments) |
| Injector Maximum Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmable Temperature Steps | Up to 99 |
| Oven Time Setting Range | 0–9999 min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Set Range | 0–1000 psi |
| Injector Total Flow Set Range | 0–1200 mL/min |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Simultaneous Detectors | Up to 4 |
| Injector Ports | Up to 3 configurable ports |
| Available Injector Types | 6 modular configurations |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870 TVOC |
| Temperature Control Range | 25–450 °C |
| Maximum Ramp Rate | 60 °C/min |
| Cooling Rate | 1 °C/min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–1000 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient + 6 °C to 399 °C |
| Temperature Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 300 °C to 50 °C in ~6 min |
| Carrier Gas Flow Range | 0–600 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Total Injector Flow Setting Range | 0–600 mL/min |
| Column Oven Dimensions | 260 × 250 × 150 mm (L×H×D) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Display | 5.7″ LCD (320 × 240), Bilingual (English/Chinese) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Power Industry – Transformer Oil Dissolved Gas Analysis (DGA) |
| Oven Temperature Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 0.1–50°C/min |
| Cooling Time | ~3 min (200°C to 100°C) |
| Carrier Gas Flow Control Range | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–970 kPa (7 programmable segments) |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Temperature Stability | ±0.02°C |
| Programmable Temperature Steps | Up to 32 oven ramps |
| EPC Precision | Pressure ±0.001 psi |
| Dimensions | 400 mm × 300 mm × 400 mm (L×W×H) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable Gas Chromatograph |
| Application Field | Coal Mining Industry |
| Temperature Control Range | Ambient +4°C to 450°C |
| Maximum Ramp Rate | 0–60°C/min |
| Cooling Rate | 200°C → 100°C in ~3 min |
| Carrier Gas Flow Range & Control | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Range & Control | 0–970 kPa (7 programmable segments) |
| Injector Max Operating Temperature | 450°C |
| Injector Pressure Setting Range | Up to 450°C |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven | Supports up to four packed columns |
| Detector Compatibility | FID, TCD, FPD, methanizer, optional MS interface |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC-9870T |
| Temperature Control Range | Ambient + 6°C to 399°C |
| Ramp Rate | 0.1–40°C/min |
| Cooling Time | ~6 min (300°C to 50°C) |
| Carrier Gas Flow Range | 0–600 mL/min |
| Carrier Gas Pressure Range | 0–0.4 MPa |
| Injector Maximum Temperature | 400°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–600 mL/min |
| Column Oven Dimensions | 260 × 250 × 150 mm (L×H×D) |
| Weight | 50 kg |
| Power Consumption | 2500 W |
| Voltage | 220 V ±10% |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (⁶³Ni source) |
| Max Operating Temperature (FID) | ≤450°C |
| Programmed Temperature Ramping | 8-step linear |
| Temperature Stability | ±0.1°C |
| Temperature Gradient Uniformity | ±1% (100–350°C) |
| Data Storage Capacity | 20 chromatographic methods |
| Display | 10-inch LCD with bilingual (Chinese/English) interface |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC60 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Max Ramp Rate | 65 °C/min |
| Cool-down Time | ≤3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Inlet Max Temp | 450 °C |
| Inlet Pressure Range | 0–1000 kPa |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 kPa |
| Detector Compatibility | FID, TCD, ECD, FPD, NPD (up to 4 detectors simultaneously) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC70 |
| Temperature Control Range | Ambient +8 °C to 450 °C |
| Maximum Ramp Rate | 65 °C/min |
| Cooling Rate | 3.5 min (300 °C → 100 °C at 25 °C ambient) |
| Temperature Stability | ±0.01 °C |
| Programmed Temperature Steps | Up to 99 |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Inlet Temperature Max | 450 °C |
| Inlet Pressure Setpoint Range | 0–1000 psi |
| Inlet Total Flow Setpoint Range | 0–1000 mL/min |
| EPC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Inlet Configurations | Up to 3 simultaneously installed, 6 optional inlet types |
| Detector Capacity | 1–4 modular detectors (FID, TCD, ECD, FPD, NPD) |
| FID Detection Limit | ≤2×10⁻¹² g/s (n-hexadecane) |
| TCD Sensitivity | ≥10,000 mV·mL/mg (n-hexadecane) |
| ECD Detection Limit | ≤1×10⁻¹⁴ g/mL (63Ni source) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC80 |
| Temperature Control Range | 20–450 °C |
| Maximum Ramp Rate | 0–60 °C/min |
| Cooling Rate | 1 °C/min (from 300 °C to 100 °C in ≤3.5 min at 25 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–1000 psi |
| Injector Max Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1000 psi |
| Injector Total Flow Setting Range | 0–1000 mL/min |
| EPC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Programmed Temperature Vaporizing (PTV) Support | Yes |
| Max Temperature Ramping Steps | 99 |
| Max Hold Time per Step | 6000 min |
| Temperature Stability | ±0.01 °C |
| Temperature Uniformity | ±1% (100–350 °C) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 60–120 vials |
| Minimum Injection Volume | 0.1–5 mL |
| Standard Loop Volume | 1000 µL |
| Positioning Accuracy | <0.3 mm |
| Motion Architecture | XYZ Three-Axis |
| Needle Wash Mode | XYZ Three-Axis Cleaning |
| Integrated Purge Function | Yes |
| Observation Window | Yes |
| Built-in Filtration Module | Yes |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Benchtop Ion Chromatograph |
| Model | IC-3000 |
| Pump Pressure Range | 0–35 MPa (0–5000 psi) |
| Flow Rate Range | 0.00–10.00 mL/min |
| Eluent Flow Rate | 0.1–3.0 mL/min |
| Max Operating Pressure | 35 MPa |
| Operating Temperature Range | 30–60°C (86–140°F) |
| Temperature Stability | ±0.1°C |
| Eluent Concentration Range | 0.1–100 mM (varies by eluent chemistry) |
| Brand | Luchuang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 20 positions |
| Vial Size | 20 mL (10 mL optional |
| Sample Zone Temperature Range | Ambient to 300 °C (1 °C increment, ±0.5 °C accuracy) |
| Valve System Temperature Range | Ambient to 180 °C (1 °C increment, ±0.5 °C accuracy) |
| Transfer Line Temperature Range | Ambient to 200 °C (1 °C increment, ±0.5 °C accuracy |
| Pressure-Controlled Sampling Range | 0–0.4 MPa (continuously adjustable) |
| Purge Flow Rate | 0–400 mL/min (continuously adjustable) |
| Precision | RSD ≤3% (measured with 200 ppm ethanol in water) |
| Dimensions | 420 × 248 × 380 mm |
| Weight | ~15 kg |
| Brand | LUDAHY |
|---|---|
| Model | LD-MRF1700 |
| Origin | Beijing, China |
| Heating Power | 300 W |
| Temperature Control Range | 0–400 °C |
| Methanization Temperature | 350–380 °C |
| Temperature Sensor | Thermocouple |
| Conversion Tube Configuration | U-shaped, 1/8″ or 1/16″ OD × 250 mm |
| Inlet/Outlet Fitting | 1/8″ or 1/16″ compression |
| Catalytic Efficiency | ≥98% |
| Catalyst Lifetime | ≥2 years (under sulfur- and oil-free sample conditions) |
| Minimum Detectable Concentration (CO/CO₂) | ≤0.1 ppm (when coupled with FID) |
| H₂ Requirement | ≥60% of total carrier gas flow (by volume) |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Model | LUMiFlector |
| Beam Configuration | Single-beam |
| Detector Type | CCD (Charge-Coupled Device) |
| Wavelength Range | 290 nm – 1650 nm |
| Wavelength Accuracy | > ±20 nm |
| Stray Light | < 0.01% T |
| Automation Level | Automatic Wavelength Scanning |
| Sample Interface | Non-contact, optical surface |
| Measurement Time | ~20 s per analysis |
| Calibration | User-definable or factory-customized for specific product matrices |
| Product Parameter Output | Up to 4 simultaneous quantitative parameters per measurement |
| Preloaded Methods | Up to 8 product-specific analysis profiles |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Lumazote |
| Pricing | Available Upon Request |
| Brand | Lumenera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | LFFM-20 |
| Price Range | USD 14,000 – 28,000 |
| Sampling Rate | 0–20 kHz |
| Dynamic Range | 2 × 10⁵ |
| Spectral Response | CIE 1931 V(λ), f₁′ ≤ 4.5% |
| Detector Dimensions (mm) | 25 × 25 × 45 |
| Power Meter Dimensions (mm) | 300(L) × 210(W) × 90(H) |
| Interface | USB |
| Compliance Standards | IEC TR 61547-1, CIE TN 006:2016, IEEE 1789-2015, ENERGY STAR SSL V2.1, IES TM-30-20, CEC Title 20, ASSIST Mp, CIE SVM, Pst-LM |
| Brand | LUMEX |
|---|---|
| Origin | Canada |
| Model | Capel 205 |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (extendable to ±30 kV) |
| Pressure Range | ±1–2000 mbar |
| Detection | UV-Vis (190–600 nm, Xenon lamp, ±1 nm accuracy) |
| Capillary Temperature Control | Liquid-cooled, -10 °C to +65 °C (±0.1 °C stability) |
| Injection Modes | Voltage, Pressure, Vacuum |
| Autosampler | 59-position, Eppendorf 2 mL vials, sealed cap removal |
| Cooling System | Integrated liquid-cooled恒温 water jacket |
| Power | 110/220 VAC, 50/60 Hz, 170 W |
| Dimensions | 470 × 530 × 410 mm |
| Weight | 30 kg |
| Software | Elforun-205 (PC-based, GLP-compliant audit trail, method library, customizable reporting, spectral scanning) |
| Brand | LUMEX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Country of Assembly | China |
| Model | Capel-105 |
| Instrument Type | Capillary Electrophoresis (CE) System |
| Sample Analysis | Inorganic Ions, Small Molecules, Biomolecules |
| Operating Voltage | 1–25 kV (1 kV step increment, polarity auto-switching) |
| Detection | UV Absorbance (190–380 nm) |
| Light Source | High-Intensity Deuterium Lamp |
| Injection Mode | Pressure or Electrokinetic |
| Pressure Range | 0–99 mbar (step resolution: 1 mbar) |
| Electrokinetic Injection Voltage | 1–25 kV (1 kV step) |
| Capillary Cooling | Liquid-Cooled Thermostatic System |
| Temperature Control Range | –10 °C to +30 °C (±0.1 °C stability) |
| Capillary Dimensions | 30–100 cm length × 50/75/100 µm ID |
| Current Range | 0–200 µA |
| Flushing Pressure | 0–1000 / 2000 mbar |
| Power Consumption | 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Capel-105M |
| CE Instrument Type | Capillary Electrophoresis (CE) |
| Voltage Range | ±1–25 kV (1 kV step, polarity auto-switching) |
| Detection Wavelength | 190–400 nm |
| Light Source | High-intensity deuterium lamp |
| Pressure Range | 0–99 mbar (1 mbar step) |
| Capillary Flushing Pressure | 1000–2000 mbar (1 mbar step) |
| Capillary Dimensions | 30–120 cm length × 50 or 75 µm ID |
| Temperature Control | Water-cooled thermostating, –10 to +30 °C (±0.1 °C stability) |
| Sample Introduction | Fully automated 20-position sampler (10 inlet + 10 outlet positions), electrokinetic & pressure-driven injection |
| Current Monitoring | 0–200 µA |
| Power Supply | 110/220 VAC, 50/60 Hz, 200 W |
| Dimensions | 500 × 500 × 500 mm |
| Weight | 25 kg |
| Software | Elforun PC-based control and data analysis suite |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Model | Fluorat-02-Panaroma |
| Wavelength Range (Excitation) | 210–840 nm |
| Wavelength Range (Emission) | 210–690 nm (up to 840 nm optional) |
| Spectral Resolution | <8 nm (15 nm optional) |
| Wavelength Accuracy | <3 nm |
| Signal-to-Noise Ratio | >100 (up to 200) |
| Slit Width (Spectral Bandpass) | 1.5 nm |
| Sensitivity | >200:1 |
| Detector | PMT |
| Light Source | Pulsed Xenon Lamp |
| Cuvette Volume | 0.01–3 mL |
| Dimensions | 400 × 355 × 150 mm |
| Weight | 13 kg |
| Power Supply | 110/220 V, 50/60 Hz, 60 W |
| Brand | LUMEX |
|---|---|
| Origin | Russia |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory |
| Model | InfraLUM FT-12 |
| Wavelength Range | 760–1150 nm |
| Spectral Resolution | 8 / 16 / 32 / 64 cm⁻¹ |
| Sampling Mode | Diffuse Reflectance / Transmission |
| Data Acquisition Interval | 1 cm⁻¹ |
| Scan Speed | 1 spectrum per second |
| Sample Volume | 50 mL |
| Analysis Time | ≤90 s |
| Dimensions | 530 × 450 × 380 mm |
| Weight | 32 kg |
| Power Supply | 220 V AC, 50 Hz |
| Power Consumption | 110 W |
| Chemometrics Software | RIM (with PARCLE integration) |