| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | lab disc white |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume (H₂O) | 0.8 L |
| Speed Range | 15–1500 rpm |
| Temperature Control Range | 5–40 °C |
| IP Rating | IP65 |
| Power Input | 5 W |
| Motor Output | 3 W |
| Max. Stir Bar Length | 25 mm |
| Plate Material | Polyester Film |
| Plate Diameter | 100 mm |
| Dimensions (W × H × D) | 117 × 12 × 180 mm |
| Weight | 0.3 kg |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Standard | DIN EN 60529 |
| Voltage | 100–240 V AC |
| Frequency | 50/60 Hz |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LabDisc |
| Stirring Capacity | 0.8 L (H₂O) |
| Speed Range | 15–1500 rpm |
| IP Rating | IP65 |
| Operating Temperature | 5–40 °C |
| Relative Humidity Limit | 80 % |
| Power Input | 5 W |
| Power Output | 3 W |
| Max Stir Bar Length | 25 mm |
| Plate Material | Polyester Film-Coated Aluminum |
| Plate Diameter | Ø100 mm |
| Dimensions (W × H × D) | 117 × 12 × 180 mm |
| Weight | 0.3 kg |
| Compliance | DIN EN 60529 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Labor Pilot 2000/4 |
| Pricing | Upon Request |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Jacketed Reactor |
| Capacity | 5 L |
| Construction | Single-jacketed borosilicate glass 3.3 vessel with PTFE/FFKM wetted parts |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Pressure Range | 666 Pa (vacuum) to ambient pressure |
| Sealing Speed Limit | up to 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 24 kg |
| Port Configuration | 6 ports (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | labworldsoft® 6 Pro |
| Pricing | Available Upon Request |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | LR 1000 basic |
| Reactor Type | Jacketed Glass Reactor |
| Usable Volume | 0.5–1.0 L |
| Operating Pressure | Up to 1 bar (gauge) |
| Vacuum Capability | Down to 25 mbar |
| Max. Medium Temperature | 120 °C |
| Min. Medium Temperature | Ambient |
| Max. Viscosity | 100,000 mPa·s |
| Speed Range | 10–150 rpm |
| Heating Power | 1000 W |
| Total Input Power | 1200 W |
| Temp. Control Accuracy (with PT100 sensor) | ±0.2 K |
| Temp. Measurement Accuracy | ±0.1 K |
| Safety Cut-off Temp. Range | 50–210 °C |
| Rated Torque | 3 N·m |
| Enclosure Rating | IP21 (DIN EN 60529) |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Materials in Contact | Borosilicate Glass 3.3, AISI 316L Stainless Steel, PTFE, FKM |
| Interface Options | RS232, USB |
| Cooling Medium Inlet Temp. | ≥3 °C |
| Max. External Cooling Pressure | 1 bar |
| Shaft Diameter (with integrated clamp) | 16 mm |
| Dimensions (W×D×H) | 443 × 360 × 295 mm |
| Weight | 16 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR 1000 basic Package |
| Usable Volume | 1000 mL (max), 500 mL (min without disperser), 300 mL (min with disperser) |
| Operating Temperature Range | Up to 120 °C (heating up to 180 °C), Cooling Medium Inlet ≥3 °C |
| Working Pressure | Low-pressure operation, vacuum capability down to 25 mbar |
| Speed Range | 10–150 rpm (adjustable in 1 rpm increments) |
| Torque | 3 Nm |
| Heating Power | 1000 W |
| Total Input Power | 1200 W |
| Temperature Control Accuracy | ±1 K (with integrated sensor), ±0.2 K (with external PT100) |
| Speed Deviation | ±5 rpm |
| Temperature Measurement Resolution | 0.1 K |
| Material of Wetted Parts | AISI 316L stainless steel, Borosilicate Glass 3.3, PTFE, PEEK, FKM |
| Sealing Interfaces | 1 × NS 29/32, 3 × NS 14/23 |
| Safety Features | Adjustable upper/lower temperature limits (225 °C / 47 °C), deviation thresholds (±20 K / ±10 K), automatic shutdown on lid opening or vessel removal, manual safety circuit, thermal cut-off fuse |
| Connectivity | RS232, USB, analog output not available |
| Protection Rating | IP21 (DIN EN 60529) |
| Dimensions (W×D×H) | 443 × 360 × 295 mm |
| Weight | 16 kg |
| Ambient Conditions | 5–40 °C, ≤80% RH |
| Compliance | CE-marked, conforms to IEC 61010-1 for laboratory equipment safety |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR 1000 basic System |
| Max. Working Volume | 1000 mL |
| Min. Sample Volume (without disperser) | 500 mL |
| Max. Operating Temperature | 120 °C |
| Vacuum Capability | 25 mbar |
| Max. Viscosity | 100,000 mPa·s |
| Speed Range | 10–150 rpm |
| Stirrer Shaft Diameter (incl. integrated clamp) | 16 mm |
| Wetted Materials | AISI 316L stainless steel (1.4571), Borosilicate Glass 3.3, PTFE, PEEK, FKM |
| Reaction Vessel Opening | 1× NS 29/32, 3× NS 14/23 |
| Continuous Duty Cycle | 100 % |
| Temperature Measurement Accuracy | ±0.1 K |
| Rated Torque | 3 Nm |
| Heating Power Output | 1000 W |
| Cooling Medium Max. Pressure | 1 bar |
| Min. Adjustable Speed | 10 rpm |
| Max. Heating Temperature | 180 °C |
| Adjustable Safety Cut-off Range | 47–225 °C (±10–±20 K deviation) |
| Cooling Medium Min. Inlet Temperature | 3 °C |
| Temp. Control Accuracy (heating) | ±1 K |
| Sensor-Based Temp. Control Accuracy | ±0.2 K |
| Speed Deviation | ±5 rpm |
| Speed Display | LED, 7-segment |
| External Temp. Sensor Interface | PT100 |
| Timer | Yes, LED display |
| Speed Control Resolution | 1 rpm/step |
| Cooling Method | External circulation |
| Temp. Display (cooling circuit) | Yes |
| Safety Temp. Display | LED |
| External Sensor Usage Indicator | Yes |
| Thermal Fuse | Yes |
| Dimensions (W×D×H) | 443 × 360 × 295 mm |
| Weight | 21.897 kg |
| Ambient Operating Temp. | 5–40 °C |
| Max. Relative Humidity | 80 % |
| Protection Class (DIN EN 60529) | IP21 |
| RS232 Interface | Yes |
| USB Interface | Yes |
| Voltage | 230 V |
| Frequency | 50/60 Hz |
| Input Power Rating | 1200 W |
| Optional Voltage Variant | 115 V (R1000 basic variant) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR 1000 control System |
| Max. Working Volume | 1000 mL |
| Min. Sample Volume with Disperser | 500 mL |
| Max. Operating Temperature | 120 °C (Heating Block up to 180 °C) |
| Vacuum Capability | down to 25 mbar |
| Max. Viscosity Handling | 100,000 mPa·s |
| Speed Range | 10–150 rpm (adjustable in 1 rpm increments) |
| Stirring Shaft Diameter (with Integrated Clamp) | 16 mm |
| Wetted Materials | AISI 316L stainless steel, Borosilicate Glass 3.3, PTFE, PEEK, FFKM |
| Reaction Vessel Ports | 2 × NS 29/32, 2 × NS 14/23, 2 × GL 14 |
| Continuous Duty Cycle | 100 % |
| Temperature Measurement Accuracy | ±0.1 K |
| Rated Torque | 3 Nm |
| Heating Power Output | 1000 W |
| Cooling Medium Max. Pressure | 1 bar |
| Weighing Capacity | 2000 g |
| Weighing Resolution | 1 g |
| pH Measurement Range | 0–14 |
| pH Resolution | 0.1 |
| Min. Adjustable Speed | 10 rpm |
| Adjustable Safety Circuit Range | 47–225 °C (±10–20 K deviation tolerance) |
| Minimum Cooling Medium Inlet Temperature | 3 °C |
| Heating Temp. Control Accuracy | ±1 K |
| Sensor-Based Temp. Control Accuracy | ±0.2 K |
| Speed Deviation | ±5 rpm |
| Display Type | TFT touchscreen |
| External Temp. Sensor Interface | PT100 |
| Stirrer Shaft Output | Specialized torque-sensing shaft |
| Torque Measurement & Trend Logging | Yes |
| Integrated Timer | Yes |
| Timer Display | TFT |
| Speed Control Resolution | 1 rpm/step |
| Cooling Method | External circulation (via integrated cooling jacket interface) |
| Process Temp. Sensor | PT100 |
| Safety Temp. Sensor | PT1000 |
| Process Temp. Display | TFT |
| Safety Temp. Display | TFT |
| External Sensor Status Indication | Yes |
| Thermal Cut-Out Protection | Yes |
| MV1 Solenoid Valve Interface | Yes |
| pH Sensor Interface | Yes |
| pH Display | TFT |
| Dimensions (W×D×H) | 443 × 360 × 295 mm |
| Weight | 16 kg |
| Ambient Operating Temperature | 5–40 °C |
| Max. Relative Humidity | 80 % (non-condensing) |
| Enclosure Rating | IP21 (per DIN EN 60529) |
| Communication Interfaces | RS232, USB, Bluetooth |
| Electrical Supply | 230 V AC, 50/60 Hz (optional 115 V version available) |
| Max. Input Power | 1200 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Modular Benchtop Reaction System |
| Model | LR 1000 control System |
| Vessel Capacity | 1 L (500–1000 mL operational range) |
| Maximum Operating Temperature | 120 °C (heating up to 180 °C for jacket |
| Vacuum Capability | 25 mbar |
| Pressure Rating | Medium-pressure design (rated for ≤1 bar cooling medium pressure) |
| Stirring Speed Range | 10–150 rpm (adjustable in 1 rpm increments) |
| Torque Output | Up to 3 Nm |
| Viscosity Handling Limit | ≤100,000 mPa·s |
| Temperature Control Precision | ±0.2 K (with external PT100 sensor), ±1 K (integrated heating control) |
| Power Supply | 230/115 V, 50/60 Hz |
| Input Power | 1200 W (heating: 1000 W) |
| Cooling Medium Inlet Temp. | ≥3 °C |
| IP Rating | IP21 |
| Safety Compliance | DIN EN 60529, integrated safety circuit with automatic shutdown upon lid opening or vessel removal |
| Interface Options | RS232, USB, analog output (not available), external PT100 input |
| Software Compatibility | labworldsoft (optional), third-party SCADA/PLC integration via serial protocol |
| Material of Construction | Borosilicate glass 3.3 (DIN ISO 3585), AISI 316L stainless steel, PTFE, FKM |
| Sealing Interfaces | 1 × NS 29/32, 3 × NS 14/23 ground-glass joints |
| Dimensions (W×D×H) | 443 × 360 × 295 mm |
| Weight | 16 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST Configuration 1 |
| Vessel Capacity | 2000 mL |
| Construction Material | Borosilicate Glass 3.3 |
| Operating Pressure Range | Up to 6 bar (gauge) / Full Vacuum (≤ 25 mbar abs) |
| Stirring System | EUROSTAR 200 control P4 High-Torque Digital Stirrer |
| Agitator Type | LR 2000.11 Anchor Impeller with Flow-Through Orifices |
| Sealing Material | FFPM (Perfluoroelastomer) for Solvent & Thermal Resistance |
| Speed Control | Continuously Variable (0–250 rpm), Microprocessor-Controlled with Real-Time Relative Torque Monitoring |
| Safety Features | Integrated Safety Switch, Interlocked Lid Actuation |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST Configuration 2 |
| Vessel Capacity | 2000 mL |
| Construction Material | Borosilicate Glass 3.3 |
| Operating Pressure Range | Up to 6 bar (gauge) / Vacuum down to 25 mbar abs |
| Jacketed Vessel | Yes (LR 2000.1) |
| Stirring Drive | EUROSTAR 200 control P4, high-torque digital motor |
| Stirrer Type | LR 2000.11 anchor impeller with flow-through orifices |
| Sealing Material | FFPM (perfluoroelastomer) for solvent and thermal resistance |
| Speed Control | Stepless electronic regulation (0–250 rpm), microprocessor-controlled speed stability under load |
| Torque Monitoring | Integrated relative torque display for real-time viscosity trend indication |
| Safety Features | Interlocked safety switch, pressure/vacuum-rated lid assembly |
| Compatibility | ULTRA-TURRAX® disperser, temperature probe, pH electrode, and auxiliary feed ports |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LR-2.ST Configuration 3 |
| Price Range | USD 135,000 – 270,000 (FOB Hamburg) |
| Usable Volume | 2 L |
| Vessel Material | Borosilicate Glass 3.3 (DIN ISO 3585) |
| Operating Pressure | Up to 6 bar(g) |
| Vacuum Capability | ≤ 25 mbar(abs) |
| Jacketed Vessel Included | LR 2000.2 (2 L double-wall glass reactor) |
| Drive | EUROSTAR 200 control P4 high-torque digital stirrer (max. torque 200 N·cm, speed range 0–250 rpm) |
| Impeller | LR 2000.11 anchor-type with flow-through orifices |
| Sealing Material | FFPM (perfluoroelastomer, e.g., Kalrez®) for solvent and thermal resistance |
| Safety | Integrated safety switch, overtemperature/overpressure interlock readiness |
| Control | Microprocessor-based speed regulation with real-time relative torque feedback for viscosity trend monitoring |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST |
| Vessel Capacity | 500–2000 mL |
| Max Temp | 230 °C |
| Min Vacuum | 25 mbar |
| Speed Range | 8–290 rpm |
| Max Viscosity | 150,000 mPa·s |
| Materials of Construction | Borosilicate Glass 3.3, FFPM Seals, PTFE, 1.4571 Stainless Steel |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST |
| Vessel Type | Jacketed Glass Reactor (LR 2000.2) |
| Minimum Working Volume | 500 mL |
| Maximum Working Volume | 2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity Handling | 150,000 mPa·s |
| Speed Range | 8–290 rpm |
| Vertical Travel of Lifting Stand | 390 mm |
| Material of Wetted Parts | Borosilicate Glass 3.3, FFPM, PTFE, Stainless Steel 1.4571 |
| Port Configuration | 3× NS 29/32 + 2× NS 14/23 |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Ingress Protection | IP 42 |
| Interface | RS 232, Analog Output |
| Power Supply | 230 V, 50/60 Hz |
| Rated Input Power | 130 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LR-2.ST |
| Pricing | Available Upon Request |
| Capacity | 2 L (Single-Wall & Jacketed Borosilicate Glass Vessel) |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity | 150,000 mPa·s |
| Speed Range | 8–290 rpm |
| Lift Stroke | 390 mm |
| Minimum Working Volume | 500 mL |
| Maximum Working Volume | 2000 mL |
| Sealing Material | FFPM (Fluoroelastomer, up to 230 °C) |
| Wetted Materials | Borosilicate Glass 3.3, FFPM, PTFE, Stainless Steel 1.4571 |
| Port Configuration | 3 × NS 29/32, 2 × NS 14/23 |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Protection Rating | IP 42 (DIN EN 60529) |
| Interface | RS-232, Analog Output |
| Power Supply | 230 V, 50/60 Hz |
| Input Power | 130 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST |
| Configuration | Single-Wall Glass Reactor Vessel LR 2.1 |
| Minimum Working Volume | 500 mL |
| Maximum Working Volume | 2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Maximum Viscosity Handling | 150,000 mPa·s |
| Speed Range | 8–290 rpm |
| Vertical Travel of Lifting Stand | 390 mm |
| Materials in Contact with Sample | Borosilicate Glass (DIN ISO 3585), FFPM Seals, PTFE, Stainless Steel 1.4571 |
| Port Configuration | 3 × NS 29/32 + 2 × NS 14/23 |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Ingress Protection | IP 42 |
| Communication Interfaces | RS 232, Analog Output (0–10 V) |
| Power Supply | 230 V, 50/60 Hz |
| Rated Input Power | 130 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST Starvisc 200 |
| Working Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity | 100,000 mPa·s |
| Min. Agitation Speed | 6 rpm |
| Lift Stroke | 390 mm |
| Stirring Shaft Max. Torque | 200 N·cm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening Configuration | 3× NS 29/32 + 2× NS 14/23 |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST the Allrounder |
| Usable Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity | 100,000 mPa·s |
| Speed Range | 8–290 rpm |
| Lifting Stroke | 390 mm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening | 3 × NS 29/32, 2 × NS 14/23 |
| Max. Stirring Torque | 200 N·cm |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Control | Microprocessor-based speed regulation with load-compensated stability |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Model | LR-2.ST the Allrounder |
| Reactor Type | Jacketed Glass Reactor System |
| Working Volume | 0.5–2.0 L |
| Maximum Operating Pressure | Up to 6 bar (gauge) |
| Vacuum Capability | ≤25 mbar (abs) |
| Temperature Range | Ambient to +230 °C |
| Speed Range | 8–290 rpm |
| Max. Torque | 120 N·cm |
| Max. Viscosity | 100,000 mPa·s |
| Drive Motor | EUROSTAR 200 control motor with microprocessor-based speed regulation |
| Sealing Material | FFPM (perfluoroelastomer) for solvent and high-temp resistance |
| Wetted Parts | Borosilicate glass 3.3, PTFE, FFPM, 1.4571 stainless steel |
| Port Configuration | 3 × NS 29/32 + 2 × NS 14/23 standard ground glass joints |
| Vertical Travel of Lift Stand | 390 mm |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Power Supply | 115 V, 50/60 Hz |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST the Compact Power |
| Usable Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity Handling | 50,000 mPa·s |
| Speed Range | 8–290 rpm |
| Lifting Stroke | 390 mm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening Configuration | 3× NS 29/32 + 2× NS 14/23 |
| Max. Stirring Torque | 60 N·cm |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Control | Microprocessor-based speed regulation with load compensation |
| Safety | Integrated safety switch, motor torque monitoring, overheat protection |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST the High-Performer |
| Usable Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity Handling | 150,000 mPa·s |
| Speed Range | 8–290 rpm |
| Lifting Column Travel | 390 mm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening Configuration | 3× NS 29/32 + 2× NS 14/23 |
| Max. Stirring Torque | 660 N·cm |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Imported |
| Model | LR-2.ST the High-Performer |
| Instrument Category | Laboratory Reactor |
| Usable Volume | 0.5–2 L |
| Vessel Material | Borosilicate Glass (DIN ISO 3585), Stainless Steel 1.4571 (AISI 316Ti), FFPM & PTFE Seals |
| Operating Pressure Range | Up to 6 bar (gauge), Down to 25 mbar (absolute vacuum) |
| Temperature Range | Ambient to +230 °C |
| Vacuum Capability | ≤25 mbar (absolute) |
| Max. Viscosity Handling | 150,000 mPa·s |
| Speed Range | 8–290 rpm |
| Torque-Controlled Speed Stability | Microprocessor-regulated, load-compensated |
| Vertical Travel of Lifting Column | 390 mm |
| Port Configuration | 3 × NS 29/32, 2 × NS 14/23 |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 25 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH (non-condensing) |
| Power Supply | 115 V, 50/60 Hz |
| Compliance | CE, UL Listed, Designed per EN 61000-6-2 / EN 61000-6-4 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | LR-2.ST the Versatile |
| Usable Volume | 500–2000 mL |
| Temperature Range | Ambient to 230 °C |
| Vacuum Capability | Down to 25 mbar |
| Max. Viscosity Handling | 70,000 mPa·s |
| Speed Range | 8–290 rpm |
| Lifting Column Travel | 390 mm |
| Wetted Materials | Borosilicate Glass (DIN ISO 3585), FFPM, PTFE, Stainless Steel 1.4571 |
| Reactor Opening Configuration | 3× NS 29/32 + 2× NS 14/23 |
| Max. Stirring Torque | 100 N·cm |
| Dimensions (W×H×D) | 460 × 1240 × 430 mm |
| Weight | 34 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Control | Microprocessor-based speed regulation with load-compensated stability |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Modular Benchtop Reactor System |
| Model | LR-2.ST the Versatile |
| Vessel Capacity | 2 L (500–2000 mL usable volume) |
| Operating Pressure Range | Up to 6 bar (gauge), down to 25 mbar absolute vacuum |
| Temperature Range | Ambient to +230 °C |
| Speed Range | 8–290 rpm |
| Max. Torque | 100 N·cm |
| Max. Viscosity Handling | 70,000 mPa·s |
| Drive Motor | EUROSTAR 100 control-type stirrer with bidirectional rotation |
| Sealing Material in Contact | FFPM (perfluoroelastomer), PTFE, borosilicate glass 3.3, stainless steel 1.4571 (AISI 316Ti) |
| Port Configuration | 3 × NS 29/32, 2 × NS 14/23 |
| Vertical Travel of Lift Stand | 390 mm |
| Dimensions (W × H × D) | 460 × 1240 × 430 mm |
| Weight | 34 kg |
| Power Supply | 115 V, 50/60 Hz |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH (non-condensing) |
| Control Interface | Removable WiCo wireless controller with real-time torque trend display and microprocessor-based speed regulation |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | M 20 Universal Mill |
| Instrument Type | Grinder |
| Sample Applicability | Hard, brittle materials |
| Feed Particle Size | < 7 mm |
| Output Particle Size | 1–80 µm |
| Batch Grinding Capacity | 250 mL |
| Grinding Media | Stainless steel cutting head (1.4034) and grinding chamber (1.4301) |
| Motor Input Power | 450 W |
| Motor Output Power | 225 W |
| Max. Speed | 20,000 rpm |
| Max. Peripheral Speed | 72 m/s |
| Max. Feed Hardness | 5 Mohs |
| Operating Cycle | 7 min ON / 10 min OFF |
| Cooling | Water-jacketed chamber (external coolant connection) or dry ice cooling |
| Dimensions (W × H × D) | 170 × 350 × 170 mm |
| Weight | 6.6 kg |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤ 80 % |
| Protection Class | IP 21 (DIN EN 60529) |
| Voltage | 230 / 115 / 100 V |
| Frequency | 50/60 Hz |
| Total Input Power | 550 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M20 |
| Price | Upon Request |
| Grinding Principle | Shear/Impact |
| Motor Input Power | 440 W |
| Motor Output Power | 225 W |
| Max Speed | 20,000 rpm |
| Max Peripheral Speed | 72 m/s |
| Max Working Volume | 250 mL |
| Max Feed Hardness | 5 Mohs |
| Max Feed Particle Size | 7 mm |
| Rotor Material | Stainless Steel 1.4034 |
| Grinding Chamber Material | Stainless Steel 1.4301 |
| Duty Cycle | 7 min ON / 10 min OFF |
| Jacketed Chamber with Water Cooling | Yes |
| Dry Ice Cooling in Chamber | Yes |
| Liquid Nitrogen Cooling in Chamber | No |
| Dimensions (W × H × D) | 170 × 350 × 170 mm |
| Weight | 6.6 kg |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | 80 % |
| Ingress Protection | IP21 |
| RS232 Interface | No |
| Analog Output | No |
| Voltage | 230 / 115 V |
| Frequency | 50 / 60 Hz |
| Instrument Input Power | 440 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | M20 |
| Instrument Type | Laboratory Grinder |
| Sample Suitability | Hard and Brittle Materials (Dry Grinding Only) |
| Final Particle Size | < 0.01 mm |
| Motor Input/Output Power | 440 W / 225 W |
| No-Load Speed | 20,000 rpm |
| Tip Speed | 72 m/s |
| Grinding Chamber Volume | 250 mL |
| Chamber & Lid Material | Stainless Steel AISI 304 |
| Duty Cycle | 7 min ON / 10 min OFF |
| Max. Feed Particle Size | 6–7 mm |
| Dimensions (W×D×H) | 170 × 170 × 350 mm |
| Weight | 6.6 kg |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Ingress Protection Rating | IP21 |
| Cooling | External Jacketed Chamber with Water Circulation Ports |
| Dual-Chamber Capability | Yes (Shared Motor Drive) |
| Safety | Integrated Current-Limiting Overload Protection |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M20 |
| Motor Input Power | 620 W |
| Motor Output Power | 260 W |
| Max. Speed | 20000 rpm |
| Max. Peripheral Speed | 72 m/s |
| Max. Working Volume | 250 mL |
| Max. Feed Hardness | 5 Mohs |
| Max. Feed Size | 7 mm |
| Rotor & Cutting Tools Material | Stainless Steel 1.4034 |
| Grinding Chamber Material | Stainless Steel 1.4301 |
| Duty Cycle | 7 min ON / 10 min OFF |
| Jacketed Chamber with Water Cooling | Yes |
| Dry Ice Cooling Compatibility | Yes |
| Liquid Nitrogen Cooling | No |
| Dimensions (W × D × H) | 170 × 350 × 170 mm |
| Weight | 6.6 kg |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | 80 % |
| Ingress Protection | IP21 |
| Voltage | 230 / 115 V |
| Frequency | 50 / 60 Hz |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | General Distributor |
| Origin Category | Imported |
| Model | M 20 Universal Mill |
| Price | Upon Request |
| Motor Input Power | 450 W |
| Motor Output Power | 225 W |
| Max. Speed | 20,000 rpm |
| Max. Peripheral Speed | 72 m/s |
| Max. Working Volume | 250 mL |
| Max. Feed Hardness | 5 Mohs |
| Max. Feed Particle Size | 7 mm |
| Rotor/Cutting Tool Material | Stainless Steel 1.4034 |
| Grinding Chamber Material | Stainless Steel 1.4301 |
| Operating Time (ON) | 7 min |
| Cooling Interval (OFF) | 10 min |
| Jacketed Grinding Chamber (Water-Coolable) | Yes |
| Dry-Ice Cooling Compatible | Yes |
| Dimensions (W × H × D) | 170 × 350 × 170 mm |
| Weight | 6.6 kg |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % |
| Ingress Protection | IP21 (per DIN EN 60529) |
| Voltage | 230 V AC |
| Frequency | 50/60 Hz |
| Total Instrument Input Power | 550 W |
| Optional Voltages | 230 V / 115 V / 100 V |