Dissolved Oxygen Meter
Filter
Showing 121–150 of 260 results
| Brand | Mettler Toledo |
|---|---|
| Model | FG4 |
| Measurement Principle | Galvanic Cell (Self-Polarizing) |
| Temperature Compensation | Automatic (NTC 30 kΩ) |
| Atmospheric Pressure Compensation | Manual or Optional Barometric Sensor Input |
| Salinity Compensation | Manual Input (0–70 g/L) |
| Display | Backlit LCD with Electrode Status Indicator |
| Power Supply | 4 × AA Batteries (incl.) |
| IP Rating | IP67 |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –25–70 °C |
| Compliance | CE, RoHS, ISO 5814 (Dissolved Oxygen — Electrochemical Probe Method) |
| Electrode Compatibility | LE611 (Standard), LE612 (Ruggedized) |
| Data Output | None (Standalone Unit) |
| Calibration | 1-point Air Saturation or 2-point (Air + Zero Solution) |
| Units | mg/L, % saturation, ppm, µmol/L |
| Resolution | 0.01 mg/L (DO), 0.1 °C (Temp) |
| Accuracy | ±0.2 mg/L (0–20 mg/L), ±0.5 °C (Temperature) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FG4 |
| Measurement Principle | Galvanic Cell (Zero-Polarization) |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C |
| DO Range (%) | 0.00–199.9% (extended to 400%) |
| DO Range (mg/L & ppm) | 0.0–45.0 mg/L (ppm) |
| DO Resolution | 0.1% / 0.01 mg/L / 0.01 ppm |
| DO Accuracy | ±1% of reading or ±1 mg/L (whichever is greater) |
| Salt Range | 0.0–50.0 ppt (0.1 ppt resolution) |
| Atmospheric Pressure Range | 375–825 mmHg / 500–1100 mbar / 500–1100 hPa |
| Pressure Resolution | 1 unit |
| Calibration Points | 2-point (0% and 100% O₂) |
| Data Storage | 30 measurements |
| Display | Backlit LCD with simultaneous readout of DO value, temperature, endpoint status, and compensation indicators |
| Enclosure Rating | IP54 |
| Power Supply | 4 × 1.5 V AAA batteries |
| Operating Environment | 0–40 °C, 5–80% RH (non-condensing) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Online DO Analyzer |
| Measurement Principle | Optical Luminescence Quenching (ISO 5814:2012 compliant) |
| Range | 0.00–80.00 mg/L (0– saturation, 0–50 ppm, 0–50,000 ppb) |
| Accuracy | ±0.2 mg/L at 25°C |
| Repeatability | ≤0.05% of reading |
| Detection Limit | <2 ppb (in high-purity water mode) |
| Sensor Technology | ISM® (Intelligent Sensor Management) enabled |
| Compliance | FDA 21 CFR Part 11 ready, USP <1231>, ASTM D888, ISO 5814, EN 25814 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S4, S9 |
| Portability | Portable |
| Measurement Principle | Polarographic (Clark-type) or Optical (Luminescence-based) — configurable per probe |
| Measurement Range | 0.00–50.0 mg/L (ppm) |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–50 mg/L) |
| Repeatability | ±0.05% of reading |
| Detection Limit | ±2 ppb (O₂ in water) |
| Ingress Protection | IP67 |
| Electrode Compatibility | ISM® (Intelligent Sensor Management) enabled |
| Data Interface | Waterproof USB (IP67-rated) |
| Display | High-contrast, sunlight-readable LCD with StatusLight™ indicator |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S900 |
| Instrument Type | Portable |
| Measurement Range | 0–50 mg/L |
| Accuracy | ±0.1 mg/L |
| Repeatability | ±0.05 mg/L |
| Detection Limit | 0 mg/L |
| Sensor Interface | Digital (InLab® OptiOx) |
| Channel Configuration | Single-channel, modularly expandable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | SG9 |
| Instrument Type | Laboratory-Portable |
| IP Rating | IP67 |
| Measurement Principle | Optical Luminescence (RDO® Technology) |
| DO Range | 0.00–80.00 mg/L (ppm) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–80 mg/L) |
| Saturation Range | 0.0–50.0% |
| Saturation Resolution | 0.1% |
| Barometric Pressure Range | 500–1100 mbar |
| Pressure Resolution | 0.1 mbar |
| Data Storage | 500 GLP-compliant records |
| Calibration Management | ISM® Intelligent Sensor Management |
| Sensor Interface | Digital ISM-enabled OptiOx probe |
| Communication | Infrared (IR) interface |
| Operating Modes | Standard / Expert |
| Endpoint Options | Auto, Manual, Timed |
| Compliance | GLP, ISO/IEC 17025-supporting workflows, FDA 21 CFR Part 11-ready (with optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SG6 |
| Temperature Range | 0.0–60.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Dissolved Oxygen Range | 0.0–600 % saturation / 0.00–99.00 mg/L |
| DO Resolution | 0.1–1 % / 0.01 mg/L |
| DO Accuracy | ±0.5 % |
| Atmospheric Pressure Range | 500–1100 mbar |
| IP Rating | IP67 |
| Data Storage | 200 GLP-compliant records |
| Display | Backlit custom LCD |
| Power Supply | 4 × AA alkaline or rechargeable batteries |
| Operating Environment | 5–40 °C, 5–80 % RH (non-condensing) |
| Interface | Infrared (IR) for data transfer to printer or PC (RS232/USB via optional adapter) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 35615-20 |
| Price Range | USD 1–4,999 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| Measurement Range | 0.00–19.9 mg/L (ppm) |
| Accuracy | ±1.5% of full scale |
| Repeatability | ±0.05% of reading |
| Detection Limit | 0.00 mg/L (±2% relative error at low concentration) |
| Saturation Range | 0.0–199.9% |
| Saturation Accuracy | ±1.5% of full scale |
| Temperature Range | 0–50 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | Automatic or manual, 0–50 °C |
| Data Storage | 100 readings |
| Interface | RS232 serial output |
| Power | 4 × 1.5 V AA batteries (>200 hours continuous operation) |
| Dimensions | 8.9 × 18.6 × 4.4 cm (W × H × D) |
| IP Rating | IP67 (for optional field-capable configurations) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 05991-36 |
| Price Range | USD $1–4,999 |
| Instrument Type | Laboratory |
| Measurement Principle | Electrochemical Clark-type Polarographic Probe |
| Measurement Range | 0–19.99 mg/L (DO), 0–600.0% saturation |
| Accuracy | ±0.5% of full scale (DO), ±0.002 pH units |
| Repeatability | ±0.15% of reading |
| Detection Limit | 0.01 mg/L (DO), 0.1% saturation |
| Temperature Range (for DO mode) | 0–50 °C |
| Temperature Compensation | Automatic or manual (0–50 °C) |
| Salinity Compensation | Manual or automatic (0–50 ppt) |
| Atmospheric Pressure Compensation | Manual or automatic (450–825 mmHg) |
| Data Storage | 500 measurement sets with timestamp |
| Interface | RS232 serial output |
| Dimensions | 15.5 × 17.5 × 6.9 cm (L×W×H) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 35805-54 |
| Instrument Type | Laboratory Benchtop/Field-Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Dissolved Oxygen Range | 0.00–80.00 mg/L (ppm) |
| Accuracy | ±0.2 mg/L (at 25 °C, within 0–20 mg/L range) |
| Repeatability | ±0.05% of reading |
| Detection Limit | 0.00 mg/L ± 2% of full scale |
| Temperature Compensation | Automatic or manual (0–50 °C) |
| IP Rating | IP67 |
| Data Storage | 50 readings |
| Dimensions (W×H×D) | 8.9 × 18.6 × 4.4 cm |
| Probe Cable Length | 15 m |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 35613-22 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Dissolved Oxygen Range | 0.00–20.00 mg/L (ppm) |
| Saturation Range | 0.0–200.0% |
| DO Accuracy | ±1.5% of full scale |
| Saturation Accuracy | ±1.5% of full scale |
| Resolution | 0.01 mg/L and 0.1% |
| Repeatability | ±0.05% FS |
| Detection Limit | ±2% FS |
| Temperature Range (for DO measurement) | 0–50 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Compensation | Automatic or Manual (0–50 °C) |
| Power | 4 × AA batteries (≈500 hours life) |
| Dimensions | 15.7 × 8.5 × 4.2 cm (L×W×H) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 35418-00 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| Measurement Range | 0.00–80.00 mg/L (ppm) |
| Accuracy | ±0.2 mg/L |
| Repeatability | ±0.05% of reading |
| Detection Limit | 0.00 mg/L with ±2% relative error |
| Origin | USA |
|---|---|
| Instrument Type | Laboratory Benchtop |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Range | 0.00–80.00 mg/L |
| Accuracy | ±0.2 mg/L |
| Repeatability | ±0.05% of reading |
| Detection Limit | 0.00 mg/L (±2 digits at zero) |
| Temperature Compensation | Automatic or Manual (0–50 °C) |
| Atmospheric Pressure Compensation | Automatic or Manual (450–825 mmHg) |
| Salinity Compensation | Automatic or Manual (0–50 ppt) |
| Data Storage | 100 readings |
| Dimensions | 15.5 × 17.5 × 6.9 cm (L×W×H) |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | ST400D |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| Range | 0.0–200.0 % saturation |
| Temperature Range | 0–50 °C |
| Accuracy | ±0.2 mg/L |
| Detection Limit | 0.00–20.0 mg/L (ppm) |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | STARTER 300D |
| Pricing | Available Upon Request |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | STARTER 300D (ST300D) |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| DO Range | 0.00–19.99 mg/L (and 20.0–45.0 mg/L), 0–400% saturation |
| Accuracy | ±0.3 mg/L (DO), ±1% (saturation), ±0.3 °C (temperature) |
| Repeatability | 0.1% |
| Temperature Range | 0–50 °C |
| Resolution | 0.01 mg/L (0–19.99 mg/L), 0.1 mg/L (20–45 mg/L), 0.1 °C |
| Display | LCD |
| Power | 4 × AAA batteries (included) |
| Battery Life | Up to 250 hours |
| Dimensions (H×L×W) | 35 × 170 × 90 mm |
| Weight | 0.16 kg |
| IP Rating | IP54 |
| Data Storage | 30 measurement records |
| Temperature Compensation | Automatic, NTC 30 kΩ sensor |
| Operating Environment | 5–40 °C, ≤80% RH (non-condensing) |
| Included Electrodes | STDO11 dissolved oxygen probe, STTEMP30 temperature probe |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orion Star A |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orion Star A |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orion Star A |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orion Star A113 |
| Pricing | Upon Request |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 600 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Measurement Range | 0.00–20.00 mg/L |
| Resolution | 0.01 mg/L (DO), 0.1% (saturation), 0.1 °C (temperature) |
| Accuracy | ±1.5% FS (DO and saturation), ±0.3 °C (temperature) |
| Salinity Compensation Range | 0.0–50.0 g/L |
| Atmospheric Pressure Compensation Range | 500–1499 mmHg (66.6–199.9 kPa) |
| Temperature Compensation | Automatic, 0–50 °C |
| Power Supply | 4 × AAA alkaline batteries |
| Battery Life | >100 hours |
| Dimensions | 140 × 70 × 35 mm |
| Weight | 200 g |
| Brand | Palintest |
|---|---|
| Origin | United Kingdom |
| Model | Micro 800 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| DO Range | 0.00–50.00 mg/L |
| DO Resolution | 0.01 mg/L / 0.1% saturation |
| DO Accuracy | ±1% of reading (≤20 mg/L or ≤200% sat) / ±10% of reading (>20 mg/L or >200% sat) |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100,000 mg/L |
| Salinity Range | 0–70 PSU |
| Temperature Range | −5 to +50 °C |
| IP Rating | IP67 (instrument), IP68 (probe) |
| Battery Life | >20 h (alkaline), >40 h (NiMH) |
| Data Storage | 3,000 full-parameter records with GPS and barometric metadata |
| GPS | 12-channel internal antenna, ±10 m 3D accuracy |
| Operating Temperature | −20 to +70 °C |
| Probe Submersion Depth | Up to 30 m |
| Dimensions (main unit) | 90 × 180 × 39 mm |
| Weight (with batteries) | 450 g |
| Probe Dimensions | 250 × 24 mm (L × Ø) |
| Cable Length | 3 m (extendable) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | PDO-1000 |
| Price Range | USD 0.14–714 (based on ¥1–4999) |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| Measurement Range | 0.00–80.00 mg/L |
| Accuracy | ±0.2 mg/L |
| Repeatability | 0.05% RSD |
| Detection Limit | ±2 ppb |
| Resolution | 0.01 mg/L / 0.01% air saturation / 0.1 °C |
| Response Time | <30 s |
| Temperature Range | 0–50 °C |
| Calibration | Factory-pre-calibrated, optional field calibration |
| Data Storage | 4 MB Flash memory (≥500 data sets) |
| Interface | USB 2.0 |
| Power | Rechargeable battery (≈1000 min operation per charge) |
| Sensor Material | Stainless steel |
| Cable Length | 8 m |
| Brand | PME |
|---|---|
| Origin | USA |
| Model | miniDOT |
| Instrument Type | Standalone In-situ Logger |
| Measurement Principle | Optical Fluorescence Quenching |
| DO Range | 0–150% saturation |
| DO Accuracy | ±10 µmol/L or ±5% of reading (whichever is greater) |
| DO Detection Limit | 0.05 µmol/L |
| DO Repeatability | ±0.05% saturation |
| Temperature Range | 0–30 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Data Storage | Internal 2 GB microSD card |
| Power Supply | Two AA batteries |
| Sampling Interval | Configurable from 1 min to 60+ days (e.g., 1-min interval → ~500 KB/365 days |
| Brand | Rikari |
|---|---|
| Origin | Japan |
| Model | DO-11Z |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Measurement Range | 0–20 mg/L |
| Accuracy | ±2% of reading |
| Repeatability | ±2% of reading |
| Detection Limit | 0.01 mg/L |
| Sensor Type | Cylindrical OXNIT Galvanic Probe with Replaceable Membrane |
| Enclosure Rating | IP67 |
| Display Resolution | Adjustable between 0.01 mg/L and 0.1 mg/L |
| Brand | Sanxin |
|---|---|
| Model | MP516 |
| Measurement Principle | Polarographic (Clark-type) Electrochemical Detection |
| DO Range | 0–40.00 mg/L (ppm) / 0–200.0 % saturation |
| Accuracy | ±0.10 mg/L |
| Temp. Compensation | 0–45 °C (auto) |
| Salinity Compensation | 0–45 ppt (auto) |
| Barometric Compensation | 80–105 kPa (integrated sensor) |
| Calibration Modes | Water-saturated air & air-saturated water |
| Temp. Range (sensor) | 0–45 °C |
| Temp. Accuracy | ±0.4 °C |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Electrode Type | Replaceable DO500 polarographic sensor with DO503 membrane cap and DO502 electrolyte solution |
| Includes | 901 Smart Stirrer, 602 Universal Electrode Holder, Cathode Polishing Paper |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SX716 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Probe |
| Measurement Range | (0–20.00) mg/L (ppm), (0–200.0)% |
| Accuracy | Meter: ±0.10 mg/L |
| System (with probe) | ±0.40 mg/L |
| Repeatability | 0.1% |
| Detection Limit | 0.1 / 0.01 mg/L (ppm), 1 / 0.1 % |
| Response Time | ≤30 s (90% response at 25 °C) |
| Temperature Compensation Range | (0–45) °C (automatic) |
| Salinity Compensation Range | (0–45) ppt (automatic) |
| Barometric Pressure Compensation Range | (66–200) kPa (manual) |
| Data Storage | 100 sets (ID, DO value, unit, temperature) |
| Power Supply | 2 × AA batteries (1.5 V each) |
| Dimensions & Weight | Meter: 65 × 120 × 31 mm / 180 g |
| Carrying Case | 255 × 210 × 50 mm / 790 g |
| Environmental Operating Conditions | 5–35 °C, ≤85% RH |
| Ingress Protection Rating | IP57 |
| Certifications | ISO 9001:2000, CE, CMC |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Probe — Clark-type Polarographic |
| Measurement Range | 0–20.00 mg/L (ppm) |
| Accuracy | ±0.30 mg/L |
| Repeatability | 0.1 mg/L |
| Detection Limit | ±0.30 mg/L |
| Resolution | 0.01/0.1 mg/L (ppm), 0.1/1 % |
| Response Time | ≤30 s (at 25 °C, 90% response) |
| Zero Drift | ≤0.10 mg/L |
| Temperature Compensation Range | 0–45 °C (automatic) |
| Salinity Compensation Range | 0–45 ppt (automatic) |
| Barometric Pressure Compensation | 60.0–199.9 kPa (manual) |
| Temperature Measurement Range | 0–100 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.5 °C ±1 digit |
| Data Storage | 500 sets (ID, date, time, DO value, unit, temperature) |
| Power Supply | 3 × AA batteries (1.5 V) or DC 5 V via USB |
| Dimensions (instrument) | 88 × 170 × 33 mm |
| Weight (instrument) | 313 g |
| IP Rating | IP57 |
| Included Accessories | DO500 polarographic DO probe, DO502 electrolyte solution (30 mL), DO503 membrane caps (×3), cathode polishing paper (×2), PC-Link software CD, USB cable, heavy-duty carrying case, user manual |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | DO-610 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| Measurement Range | DO: 0.0–20.0 mg/L (or 0–200% saturation) |
| Temperature | 0–100 °C |
| Accuracy | ±3% of reading (DO), ±1 °C (temperature) |
| Repeatability | ±5% |
| Detection Limit | 0.01 mg/L |
| Automatic Temperature Compensation Range | 0–40 °C |
| Calibration Points | 1-point or 2-point (air-saturated water or zero-oxygen solution) |
| Salinity Compensation Range | 0–35 g/L |
| Atmospheric Pressure Setting Range | 0.5–1.5 atm |
| Power Supply | One 9 V alkaline battery |
| Dimensions | 75 × 140 × 38 mm |
| Weight | <220 g |
| Data Storage Capacity | 99 measurement records with timestamp and metadata (DO, % sat, T, salinity, pressure) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DO-810 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence-based Optical Sensing |
| Range | 0.0–20.0 mg/L (DO) and 0–200 % saturation |
| Accuracy | ±0.2 mg/L (isothermal calibration condition) |
| Repeatability | ≤ ±3% |
| Detection Limit | 0.01 mg/L |
| Temperature Range | 0–50 °C |
| Temp. Accuracy | ±1 °C |
| Temp. Compensation Range | 0–50 °C |
| Calibration | 1- or 2-point |
| Salinity Compensation | Adjustable 0–35 g/L (ppt) |
| Atmospheric Pressure Adjustment | 0.5–1.5 atm |
| Sensor Cable Length | 2 m |
| Probe Storage Temp. | −40 to +85 °C |
| Sensor Drift | <1% per year |
| Fluorescent Cap Lifetime | 12 months (normal use) |
| Data Storage Capacity | 300 sets |
| Power | Rechargeable Li-ion battery (7.4 V, 1500 mAh) |
| Dimensions | 185 × 92 × 50 mm (L×W×H) |
| Weight | ~370 g |
| IP Rating | IP67-rated housing (dust-tight and immersion-resistant up to 1 m for 30 min) |