Dissolved Oxygen Meter
Filter
Showing 61–90 of 260 results
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | HQ30d with LDO Sensor |
| Measurement Range | 0–20 mg/L (ppm) and 0–200% saturation |
| Resolution | 0.01 mg/L |
| Sensor Type | Optical (Luminescence-based) |
| Cable Options | 1 m, 3 m, 5 m, 10 m, 15 m, 30 m (standard & rugged variants) |
| Compliance | Designed for ASTM D888, ISO 5814, and EPA Method 4500-O G |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | LDO II Probe |
| Instrument Type | Online |
| Measurement Principle | Fluorescence Quenching |
| Range | 0.11–20.00 mg/L (ppm) or 0–200% saturation |
| Accuracy | ±0.1 ppm at [O₂] <5 ppm |
| Temperature accuracy | ±0.2°C |
| Repeatability | ±0.1 ppm (mg/L) |
| Detection Limit | 0 ppm |
| Calibration | Factory-calibrated, zero user calibration required |
| Maintenance Interval | Up to 24 months for fluorescent cap |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| Range | 0.01–20 mg/L (ppm) |
| Accuracy | ±0.01 mg/L |
| Repeatability | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (>8 mg/L) |
| Detection Limit | 0.01 mg/L |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LDO10103 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| Range | 0.00–20.0 mg/L, 0–200% saturation |
| Accuracy | ±1% of full scale |
| Repeatability | ±1% |
| Detection Limit | 0.01 mg/L (or 0.1 mg/L depending on configuration) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | Orbisphere 3650 / 3655 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Probe |
| Measurement Range | 0–20 ppm / 0–40 ppm / 0–8 ppm (configurable via membrane selection) |
| Accuracy | ±1% of reading |
| Detection Limit | <1 ppb |
| Temperature Range | –5 °C to 100 °C |
| Power Supply | Two AA NiCd or alkaline batteries (2.4–3 V DC) |
| Battery Life | Up to 40 hours continuous operation |
| Response Time | ≤3 minutes (from air saturation to 2 ppb) |
| Enclosure Rating | IP67 / NEMA 4 |
| Data Storage | Internal logging with RS232 digital interface |
| Maintenance Interval | Typically every 6 months |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 51X |
| Instrument Type | Online |
| Measurement Principle | Electrochemical (Clark-type and galvanic sensor compatible) |
| Measurement Range | 0.01 ppb to 20 ppm O₂ (configurable via sensor selection) |
| Accuracy | ±0.1 ppb or ±1% of reading, whichever is greater |
| Response Time (t₉₀) | ≤7.2 s |
| Data Storage Capacity | Up to 1,000 measurement records + 1,000 operator action logs |
| Analog Outputs | Three 4–20 mA (isolated, HART-compatible) + three 0–5 V (hardware-selectable) |
| Digital Communication | RS-485, PROFIBUS DP, USB, Ethernet |
| Sensor Compatibility | O₂, O₃, H₂ (via interchangeable electrochemical sensors) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | ORBISPHERE G1100 |
| Measurement Principle | Fluorescence Quenching (Lifetime-Based) |
| Range | 0–20,000 ppb |
| Repeatability | ±1 ppb + 2% (0–600 ppb), ±2 ppb + 2.5% (0–600 ppb) |
| LOD | ±2 ppb |
| Response Time (t₉₀) | 30 s |
| Resolution | 1 ppb |
| Calibration | Fully Automated, User-Programmable Single-Point Zero Calibration with Certified N₂ (99.999%, Grade 5.0) |
| Validation | Automated Single-Point Zero Verification |
| Sample Temp. | 5–45 °C |
| Sensor Temp. Rating | −5–100 °C |
| Pressure Range | 1–4 bar abs |
| Flow Rate | 50–500 mL/min |
| Enclosure | Wall/Pipe-Mounted Stainless Steel or Panel-Mounted Aluminum, IP65 |
| Analog Outputs | 3 Smart 0/4–20 mA (500 Ω), Configurable for Linear/Tri-Linear Output or Diagnostic/Alarm Signals |
| Relays | 3 Measurement Alarms (2 A / 30 VAC or 0.5 A / 50 VDC), 1 System Alarm Relay |
| Communication | RS485, Optional Profibus DP or Ethernet, USB Client/Host |
| Data Storage | Rolling or One-Time Storage for up to 1,000 Measurements and 1,000 Operator Actions |
| Display | Monochrome STN LCD (320 × 240 px) with LED Backlight |
| Compliance | EN 61326 (EMC), EN 61010-1 (Safety), Directive 73/23/EEC |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | ORBISPHERE K1100 |
| Calibration Interval | Annual |
| Response Time | <2 seconds |
| Detection Limit | 0.6 ppb |
| Accuracy | ±0.8 ppb |
| Measurement Principle | Dynamic Luminescence Quenching (Cold Light Method) |
| Compatibility | ORBISPHERE 410 Controller, 28 mm insertion fittings, flow-through cells |
| Output Options | 3 configurable relays, 3 smart analog outputs |
| Diagnostic Capability | Real-time sensor health monitoring, predictive maintenance alerts |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company |
| Product Type | Imported Online Analyzer |
| Model | POLYMETRON 9582 |
| Pricing | Upon Request |
| Measurement Principle | Electrochemical Galvanic Cell (Clark-type) |
| Measurement Range | 0–2000 ppb |
| Accuracy | Not Specified |
| Repeatability | ±0.5 ppb or ±5% (whichever is greater) |
| Detection Limit | <1 ppb |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company |
| Product Type | Imported |
| Model | 9582 |
| Instrument Category | Online Analyzer |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| Measurement Range | 0–2000 µg/L (ppb) O₂ |
| Accuracy | Not specified by manufacturer |
| Repeatability | ±5% of reading or ±0.5 µg/L O₂ (whichever is greater) |
| Detection Limit | <1 µg/L O₂ |
| Response Time (T₉₀) | ≤90 s |
| Calibration | Two-point (zero + slope) |
| Maintenance Interval | Up to 6 months |
| Analog Outputs | Dual 4–20 mA (O₂ concentration and temperature), max. load 500 Ω |
| Operating Temperature | 0–45 °C |
| Weight | 2.3 kg |
| Relay Outputs | Four programmable relays for high/low alarms and system fault indication |
| Consumables Lifetime | Up to 2 years under typical use |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | sensION+ DO6 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Probe |
| Range | 0.00–20.00 mg/L (or 0–200% saturation) |
| Accuracy | ±0.2 mg/L |
| Repeatability | ±0.05% of reading |
| Detection Limit | 0–2 ppb (dissolved oxygen in ultrapure water mode, with zero-current measurement capability) |
| Enclosure Rating | IP67 |
| Keypress Durability | >6 million cycles |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Laboratory DO Analyzer |
| Model | Z LLIG S-14 |
| Measurement Principle | Polarographic (Clark-type with mechanical self-cleaning) |
| Range | 0–15 mg/L (Fe anode) / 0–25 mg/L (Zn anode) |
| Resolution | 0.05 mg/L |
| Standard Deviation | < 0.1 mg/L |
| Operating Temperature | 0–45 °C |
| Ambient Temperature | −20–40 °C |
| Max Pressure | 3 bar |
| pH Range | 6–9 |
| Minimum Conductivity | 200 µS/cm |
| Sensor Lifetime | 15–20 years |
| Electrode Lifetime | 3–5 years |
| Abrasive Wheel Replacement Interval | 8–18 months |
| Power Supply | 24 VDC ±15%, 200 mA |
| Output Signal | Digital (RS-485 or HART-compatible, depending on transmitter configuration) |
| Brand | Hanna |
|---|---|
| Origin | Italy |
| Model | HI9147 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| DO Range | 0.0 to 50.0 mg/L (ppm) |
| Saturation | 0 to 600% |
| Accuracy | ±1% of reading |
| Resolution | 0.1 mg/L (DO), 1% (saturation) |
| Temperature Range | 0.0 to 50.0 °C |
| Temp. Accuracy | ±0.2 °C |
| Altitude Compensation | 0 to 4000 m |
| Salinity Compensation | 0 to 51 g/L |
| Electrode | HI76409 galvanic DO probe with integrated temperature sensor, 4/10/15 m cable options |
| Power | 3 × 1.5 V AAA batteries |
| IP Rating | IP67 |
| Dimensions | 185 × 72 × 36 mm |
| Weight | 450 g |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HI9143 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | HDY-2110 |
| Price Range | USD 2,800–4,200 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Clark-type Polarographic Sensor |
| Measurement Range | 0–200 µg/L |
| Accuracy | ±1.5×10⁻²/4 h |
| Repeatability | ±0.5% FS |
| Detection Limit | 0–200 µg/L |
| Basic Error | ±3.0% FS |
| Response Time | ≤30 s to 98% FS at 25 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Operating Temp. | 5–55 °C |
| Storage Temp. | −25–55 °C (electrode ≥0 °C) |
| Relative Humidity | ≤85% RH |
| Sample Temp. Range | 5–60 °C |
| Max. Suspended Solids | ≤5 µm (no colloids or oils) |
| Power | AC 220 V ±10%, 50 Hz / USB-powered rechargeable Li-ion battery (60 h continuous operation) |
| Interface | RS232 |
| Dimensions | 180 × 50 × 25 mm |
| Weight | 0.5 kg |
| IP Rating | IP55 |
| Calibration Modes | Faraday-based zero calibration & air-saturation calibration |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HDY-2110Z |
| Price Range | USD 2,800–4,200 |
| Instrument Type | Online Continuous Monitor |
| Measurement Principle | Polarographic Electrochemical Sensor |
| Measurement Range | (0.0–20.0, 0.0–200) µg/L |
| Accuracy | ±5.0% F.S. for (0.0–20.0) µg/L range |
| Repeatability | ±1.5% F.S. |
| Detection Limit | 0.10 µg/L |
| Resolution | 0.10 µg/L (ppb mode), 0.01 mg/L (ppm mode) |
| Response Time (t₉₀) | <60 s at 25 °C |
| Temperature Compensation | Automatic (5–50 °C), Manual Settable (0–55 °C) |
| Output | 4–20 mA (load 250–500 Ω), RS485 or CAN bus interface |
| Power Supply | AC 85–265 V, 45–65 Hz, ≤20 VA |
| Enclosure Rating | IP65 |
| Dimensions | 146 × 146 × 108 mm (H×W×D) |
| Panel Cutout | 138 × 138 mm |
| Weight | 1.5 kg (ppb configuration), 1.7 kg (ppm configuration) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9551-100D |
| Cable Length | 10 m |
| Operating Temperature Range | 0–40 °C |
| IP Rating | IP68 (submersible) |
| Electrode Type | Clark-type polarographic DO sensor |
| Compatibility | Designed for use with HORIBA LAQUA DO meters (e.g., LAQUA twin, LAQUA DO-110/210 series) |
| Calibration | Two-point (zero O₂ and air-saturated water) or single-point (air-saturation) |
| Response Time (t₉₀) | < 30 s in stirred water |
| Membrane | Replaceable Teflon® (PTFE) cap |
| Electrolyte | KCl-based aqueous electrolyte |
| Storage Condition | Wet storage in DO electrode storage solution or saturated KCl solution |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9551-20D |
| Cable Length | 2 m |
| Operating Temperature Range | 0–40 °C |
| IP Rating | IP68 (submersible) |
| Compatibility | Designed for use with HORIBA portable and benchtop DO meters (e.g., D-55, LAQUA twin series, or compatible analog input systems) |
| Electrode Type | Polarographic (Clark-type), membrane-covered, galvanic cell configuration |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | D-55 |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | LAQUA DO2000 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Galvanic Electrode (Clark-type) with Integrated Thermistor |
| DO Range | 0.0 to 60.00 mg/L, 0.0 to 600.0% saturation |
| DO Accuracy | ±0.1 mg/L, ±1.0% of reading |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Accuracy | ±0.5 °C |
| Salinity Compensation | 0.0 to 40.0 ppt |
| Atmospheric Pressure Compensation | 10.0 to 200.0 kPa |
| BOD Protocol | Pre-programmed 5-day method with seed correction |
| Calibration Points | Up to 2-point DO calibration |
| Memory Capacity | 2000 data sets with timestamp |
| Display | 5-inch backlit 320-segment LCD |
| Connectivity | USB (for DAS20 software), RS-232C (for printer), BNC, ATC phono, DC input |
| Power | AC adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 765 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | DO2000 |
| Instrument Type | Benchtop Laboratory Meter |
| Measurement Principle | Galvanic Cell (Electrochemical) |
| DO Range | 0.0 to 60.00 mg/L |
| DO Accuracy | ±0.1 mg/L |
| Temperature Range | −30.0 to 130.0 °C |
| Temperature Accuracy | ±0.5 °C |
| Salt Compensation | 0.0–40.0 ppt |
| Pressure Compensation | 10.0–200.0 kPa |
| BOD Method | Standard 5-Day with Seed Correction |
| Memory Capacity | 2,000 Data Sets with Timestamp |
| Communication | USB (DAS20 Software), RS-232C (Printer) |
| Display | 5-inch Backlit LCD (320-segment) |
| Power | AC Adapter (100–240 V, 50–60 Hz) |
| Dimensions | 155 × 150 × 67 mm |
| Weight | 765 g |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9520-10D |
| Cable Length | 1 m |
| Operating Temperature Range | 0–45 °C |
| IP Rating | IP67 (per electrode housing specification) |
| Compatible With | HORIBA DO meters (e.g., D-55, LAQUA DO series) |
| Electrode Type | Clark-type polarographic membrane electrode |
| Replacement Module | 7541 (for 9520-series) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | OM-71 |
| Instrument Type | Portable |
| Measurement Principle | Galvanic Cell (Electrochemical Membrane Probe) |
| Measurement Range (DO) | 0.00–20.00 mg/L |
| Accuracy (DO) | ±0.01 mg/L |
| Repeatability | ±0.05% |
| Detection Limit | ±2 ppb |
| Temperature Range (Measurement) | −30 °C to 130 °C (Display: 0.0–100.0 °C) |
| Temperature Accuracy | ±0.1 °C ±1 digit |
| Saturation DO Range | 0.0–200.0 % |
| O₂ Concentration Range | 0.0–50.0 % |
| Salt Compensation | 0–40 ppt |
| Atmospheric Pressure Compensation | Yes |
| Display | Backlit Monochrome LCD |
| Data Storage | 1,000 sets with timestamp & ID |
| Communication | USB/RS-232 (PC connectivity, GLP/GMP-compliant data export) |
| Protection Rating | IP67 |
| Operating Environment | 0–45 °C, 0–80% RH (non-condensing) |
| Power | 2 × AAA alkaline or Ni-MH batteries (~500 h battery life) |
| Dimensions (W×D×H) | 67 × 28 × 170 mm (max. thickness 80 mm) |
| Weight (without batteries) | ~270 g |
| Brand | Huake Instrument |
|---|---|
| Model | HK-318 |
| Type | Online Dissolved Oxygen Analyzer |
| Measurement Principle | Polarographic (Clark-type) Electrochemical Sensor |
| Range | 0–20 µg/L, 0–200 µg/L, or 0–20 mg/L (auto-ranging) |
| Accuracy | ±1 µg/L or ±1.5% FS (whichever is greater) |
| Repeatability | ±1.5% FS |
| Detection Limit | 0.1 µg/L or 0.1 mg/L |
| Resolution | 0.1 µg/L / 0.1 mg/L |
| Response Time (T90) | ≤60 s at 25 °C |
| Temperature Compensation | 0–50 °C (automatic or manual) |
| Temp. Sensor | Thermistor |
| Temp. Accuracy | ±0.5 °C |
| Output | Dual isolated 4–20 mA (configurable as 0–10 mA or 0–20 mA), max. load 800 Ω |
| Alarm Outputs | 2 programmable relay outputs |
| Communication | RS-485, Profibus DP, HART |
| Power Supply | AC 100–240 V, 50–60 Hz |
| Power Consumption | ≤8 W |
| Enclosure | Cast aluminum, IP65-rated front panel |
| Dimensions | 146 × 146 × 154 mm (W × H × D) |
| Panel Cutout | 139 × 139 mm |
| Weight | 2 kg |
| Operating Ambient | 5–45 °C |
| Storage Temp. | −25–55 °C (electrode must be stored >0 °C) |
| Sample Requirements | 5–50 °C, flow rate 50–350 mL/min, suspended solids ≤5 µm, no colloids or oil, RH ≤90% non-condensing |
| Brand | Huakeyi |
|---|---|
| Origin | Beijing, China |
| Model | HK-258 |
| Instrument Type | Portable |
| Measurement Principle | Polarographic Electrochemical Sensor |
| Measurement Range | 0.00–200 µg/L |
| Accuracy | ±0.3% FS or 1 µg/L (whichever is greater) |
| Repeatability | 0.05% |
| Detection Limit | 0.1 µg/L |
| Resolution | 0.1 µg/L, 0.01 mg/L |
| Temperature Compensation Range | 0–50 °C (manual or automatic) |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Response Time (T90) | ≤60 s at 25 °C |
| Power Supply | Built-in 3.7 V rechargeable Li-ion battery |
| Battery Life | ≥40 h per charge |
| IP Rating | IP68 |
| Dimensions (Transmitter) | 123 mm × 86 mm × 267 mm (L×W×H) |
| Weight (Transmitter) | 1.5 kg |
| Brand | JENCO |
|---|---|
| Origin | USA |
| Model | 9173 / 9173R |
| Measurement Principle | Polarographic (Clark-type) |
| Range | 0.00–20.00 ppm DO |
| Accuracy | ±2% FS |
| Air Saturation Range | 0.0–200.0% |
| Temp Range | −6.0–46.0 °C |
| Temp Accuracy | ±0.3 °C |
| Resolution | 0.01 ppm DO, 0.1% sat, 0.1 °C |
| Temp Compensation | Automatic (−6.0–46.0 °C) |
| Pressure Compensation | Adjustable (600–1100 mbar, default 1013 mbar) |
| Salinity Compensation | Adjustable (0.0–40.0 ppt, default 0.0 ppt) |
| Calibration Memory | Yes |
| Communication | RS-232C (9173R only) |
| Power | AC adapter (DC 9 V) or 6 × AA batteries |
| Dimensions | 230 × 165 × 80 mm |
| Weight | ~650 g (without batteries) |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Electrode | Imported polarographic DO sensor (LD-900-7) |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SR |
| Pricing | Available Upon Request |
| Detection Method | DL Colorimetric Method |
| Detection Time | 3 minutes |
| Lower Detection Limit | 0.1 mg/L |
| Measurement Range | 0.0–10.0 mg/L |
| Accuracy | ±5% |
| Reagent Format | Single-use dedicated reagent kit |
| Sample Types | Distilled water, drinking water, domestic water, aquaculture water, seawater, surface water, wastewater |
| Brand | Lamotte |
|---|---|
| Origin | USA |
| Model | 1761 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical Galvanic Cell Probe |
| Measurement Range | 0–20.00 ppm (mg/L) |
| Accuracy | ±2% FS (DO), ±1.8°F (±1°C) (Temperature) |
| Resolution | 0.01 ppm (DO), 0.1°F/°C (Temperature) |
| Repeatability | ±4% |
| Detection Limit | ±2% FS |
| Altitude Compensation | 0–20,000 ft (in 1,000-ft increments) |
| Salinity Compensation | 0–50 ppt |
| Data Storage | 25 DO + temperature datasets |
| Power | Four 1.5V SR44W batteries |
| Dimensions | 1.4 × 6.9 × 1.6 in (36 × 176 × 41 mm) |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DO-30 |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type Polarographic Sensor) |
| Dissolved Oxygen Range | 0.0–20.0 mg/L |
| Resolution | 0.1 mg/L |
| Accuracy | ±0.3 mg/L |
| Repeatability | ≤0.2 mg/L |
| Temperature Range | 0.0–60.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C |
| Auto Temperature Compensation | Yes (0–50.0 °C) |
| IP Rating | IP67 |
| Power | 4 × AAA batteries |
| Battery Life | >200 h |
| Dimensions | 40 × 30 × 188 mm |
| Weight | ~0.15 kg |
| Enclosure Material | ABS |
| Brand | Leichi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JPB-607A |
| Instrument Type | Portable |
| Measurement Principle | Electrochemical (Clark-type Polarographic Sensor) |
| Dissolved Oxygen Range | 0.00–20.00 mg/L |
| Resolution | 0.01 mg/L |
| Accuracy (DO) | ±0.30 mg/L |
| Response Time (90% at 20.0 °C) | ≤45 s |
| Saturation Range | 0.0–200.0 % |
| Temperature Range | −5.0–110.0 °C |
| Temp. Accuracy | ±0.4 °C (0.0–60.0 °C), ±1.0 °C (other) |
| Salt Compensation Error | ±2% |
| Atmospheric Pressure Compensation | Manual |
| IP Rating | IP65 |
| Data Storage Capacity | 200 sets |
| Power Supply | Rechargeable Li-ion battery (DC5V input compatible) |
| Dimensions | 80 × 225 × 35 mm |
| Weight | 0.4 kg |