Electrochemical Instrument Accessories
Filter
Showing 61–87 of 87 results
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 814 |
| Instrument Type | Electrochemical Sample Processor |
| Sample Capacity | 12–48 positions (75 mL vials) |
| Sample Volume Range | 75–250 mL |
| Sample Tray Recognition | Optical identification sensor for interchangeable trays |
| Fluid Handling | Single-tower architecture with optional 1 or 2 peristaltic pumps |
| Positioning System | Single movable arm (left- or right-configurable) + single external titration position |
| Functional Capabilities | Liquid handling, precise aspiration/dispensing, automated Karl Fischer coulometric/microcoulometric water determination |
| Method Storage | Up to 999 user-programmable methods |
| Method Structure | Three-phase workflow (Start → Sample Analysis → End), each phase supporting up to 99 sequential steps |
| Interfaces | 1 × USB port, 3 × MSB (Metrohm Serial Bus) ports |
| Host Integration | Designed exclusively for seamless control by Metrohm Titrando series titrators |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Models | 814, 815 |
| Instrument Type | Electrochemical Sample Processor |
| Sample Capacity (814) | 12–48 positions (75 mL vials) |
| Sample Capacity (815) | 28–141 positions (75 mL vials) |
| Sample Volume Range (814) | 75–250 mL |
| Sample Volume Range (815) | 11–250 mL |
| Sample Tray Recognition | Optical cup identification sensor |
| Pump Configuration (814) | 1–2 peristaltic pumps |
| Pump Configuration (815) | 2–4 peristaltic pumps |
| Robotic Arm Configuration (814) | Single arm (left- or right-mounted) |
| Robotic Arm Configuration (815) | Dual arms (independently configurable left/right) |
| Dispensing Positions (814) | One external titration position |
| Dispensing Positions (815) | Two external titration positions |
| Method Storage | Up to 999 user-programmable methods |
| Method Structure | Three-phase architecture (Start → Sample Analysis → End), each phase supporting up to 99 programmable steps |
| Interface | USB 2.0 + 3× MSB (Metrohm Serial Bus) ports |
| Host Integration | Fully controlled by Titrando series titrators |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 815 |
| Instrument Category | Electrochemical Sample Processor |
| Sample Capacity | 28–141 positions (75 mL vials) |
| Sample Volume Range | 11–250 mL |
| Modular Configuration | Single or dual work towers |
| Fluid Handling | Up to four peristaltic pumps (configurable) |
| Robotic Arms | Dual movable arms (left/right orientation) |
| External Titration Positioning | Dual external titration stations |
| Detection | Optical sample cup identification sensor |
| Method Storage | 999 programmable methods |
| Method Structure | Three-phase architecture (Start / Sample Analysis / End), each phase supporting up to 99 discrete steps |
| Interfaces | 1× USB 2.0, 3× MSB (Metrohm Serial Bus) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 865 |
| Instrument Type | Electrochemical Sample Processor |
| Dosing Modes | DOS, XDOS, CNTD, LQT |
| Interface | USB (native), RS-232/USB Box (optional) |
| Display | Large graphical LCD |
| Connectivity | Supports USB Hub for concurrent peripherals (keyboard, mouse, printer, USB storage) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 869 |
| Instrument Type | Electrochemical Sample Processor |
| Sample Positions | 12 (120 mL vials) |
| Built-in Method Storage | Up to 100 user-editable methods |
| Interface | USB |
| Compatibility | Titrino Plus series titrators (direct connection, no external controller or PC required) |
| Optional Accessory | 843 Pump Unit for automated rinsing and drainage |
| Emergency Sample Slot | Yes |
| Control Interface | Integrated membrane keypad with large LCD display |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 876 |
| Instrument Type | Electrochemical Liquid Handler / Semi-Automatic Titration System |
| Connectivity | USB interface (supports USB Hub for multi-device integration), optional RS-232/USB Box for balance interfacing |
| Dosing Modes | DOS (Manual Dosing with Endpoint Monitoring), XDOS (Extended Dosing with preset volume, time, or flow rate control) |
| Compatibility | Fully interoperable with Metrohm 805 Dosimat for continuous reagent dispensing |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Import Category | Imported Instrument |
| Model | OMNIS KF Oven |
| Instrument Type | Automated Sample Processor for Electrochemical Moisture Analysis |
| Maximum Heating Temperature | 300 °C |
| Sample Capacity | Up to 100 × 6 mL vials (unattended) |
| Compatible Vial Standards | ISO 8362 (2R–30R), plus standard 6 mL crimp-top and 8 mL screw-cap vials |
| Heating Modules | Configurable with 1 or 2 independent oven modules |
| Carrier Gas Options | Dry ambient air or nitrogen, with integrated large-capacity molecular sieve dryer |
| Needle Depth Adjustment | Motorized, programmable syringe needle extension for optimal vial penetration |
| Optional Integration | OMNIS Liquid Handling Module for automatic reagent replenishment (KF reagent and methanol) |
| Brand | NorECs |
|---|---|
| Origin | Norway |
| Model | ProboStat |
| Instrument Type | Electrochemical Sample Holder |
| Operating Temperature (Long-term) | Up to 1400 °C |
| Operating Temperature (Short-term) | Up to 1600 °C |
| Sample Geometry | Disc-shaped (Ø 10–24 mm, thickness 25–50 mm) or Rod-shaped (Ø up to 24 mm, length 30–1500 mm) |
| Electrode Configurations | 2-, 3-, or 4-electrode setups |
| Gas Environment | Oxidizing, inert, reducing, corrosive, humid/dry |
| pressure range | 10⁻² mbar to 1 bar (up to 25 bar in sealed steel tube) |
| Dual-chamber capability | Yes |
| Van der Pauw measurement | Supported (4-point) |
| Seebeck coefficient measurement | Supported (rod geometry) |
| Electrical measurements | DC conductivity, impedance spectroscopy, polarization, dielectric breakdown (HV version), concentration cell, transference number, permeability, fuel cell testing |
| Brand | Origalys |
|---|---|
| Origin | France |
| Model | OrigaTrod |
| Electrode Materials | Pt, Au, Glassy Carbon, Cu, Pd, Rh, W |
| Rotation Speed Range | 100–10,000 rpm |
| Shaft Eccentricity | < 0.1 mm |
| Housing Materials | PETP, PTFE, PEEK |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 20–80 % RH |
| Weight (Electrode Assembly) | 0.325 kg |
| Dimensions (Electrode Assembly) | Ø 5.6 cm × H 24 cm |
| Controller Dimensions | W 14.2 cm × D 12 cm × H 4 cm |
| Controller Weight | 0.23 kg |
| Power Input | DC via 2.1 mm barrel jack |
| Communication Interfaces | USB 2.0, RS-232C (COM), Analog IN (BNC) |
| Electrical Safety & EMC Compliance | EN 61326-1, RoHS Directive 2002/95/EC, EMC Directive 89/336/EEC |
| Contact Design | Silver-coated graphite, mercury-free |
| Gas Purge Port | Yes |
| Bearing Type | Swiss ultra-thin precision ball bearing |
| Brand | Pine Instruments (Pine Test Equipment, Inc.) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AFMSRCE / MSR |
| Rotation Speed Range | 0–10,990 rpm |
| Motor Power | 20 W |
| Speed Display Accuracy | ±1% |
| Control Architecture | Separated Motor & Controller Units |
| Electrical Protection | Integrated Surge and Voltage Instability Protection |
| Interface | Analog Input/Output (0–10 V) for External Speed Command and Tachometer Signal Output |
| Electrode Compatibility | Standard RDE, RRDE, and Rotating Ring-Disk Electrode (RRDE) configurations |
| Brand | dc-energies |
|---|---|
| Volume | 150 mL |
| Port Configuration | One 24/25 ground-glass rotation port, four 14/20 side ports |
| Jacket Type | Double-walled with circulating coolant inlet/outlet |
| Gas Sealing | Dual F-type gas inlets + L-type gas outlet |
| Shaft Seal | PINE proprietary ceramic bearing seal assembly |
| Material | High-borosilicate glass (ASTM E438 Type I, Class A) |
| Compliance | Designed for ASTM D129, ISO 12927, and USP <797> electrochemical cell validation protocols |
| Brand | PerfectLight |
|---|---|
| Origin | Beijing, China |
| Model | IPCE |
| Light Source Wavelength Range | 300–1100 nm |
| Irradiance Calibration | 1000 W/m² |
| Focal Length | 300 mm |
| Relative Aperture | f/3.9 |
| Spectral Resolution | 0.1 nm |
| Reciprocal Linear Dispersion | 2.7 nm/mm |
| Chopper Frequency Range | 8.4 Hz – 3.7 kHz |
| Operating Frequency Range | 1 mHz – 102.4 kHz |
| Thermal Stability | 5 ppm/°C |
| Phase Resolution | 0.01° |
| Time Constant Range | 10 s – 30 ks (synchronous reference signal) |
| Irradiance Uniformity | < ±5% |
| Certified Reference Solar Cell Efficiency | >16%, FF > 0.7 |
| Sample Area Compatibility | 20 × 20 mm² |
| Filter Wheel | 7-position, including 550 nm bandpass |
| Detector | Hamamatsu S1337 UV-optimized photodiode (NIST-traceable calibration) |
| Optical Configuration | Dual-beam and single-beam modulation modes (with metrological certification) |
| Brand | Rayscience |
|---|---|
| Origin | Germany |
| Model | CVP21 |
| Instrument Type | Electrochemical Capacitance–Voltage Profiling System |
| Application Domain | Semiconductor Doping Profile Characterization |
| Carrier Concentration Range | 1×10¹¹ to 1×10²¹ cm⁻³ |
| Depth Resolution | Down to ≤1 nm |
| Sample Compatibility | Wafer-scale (up to 300 mm), micro-samples, epitaxial layers, bulk crystals |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | RedMatrix |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PS-PEC008 |
| Instrument Category | Electrochemical Instrument Accessory |
| Light Source Configuration | 8-channel integrated high-power monochromatic LED array (365–980 nm + white light options) |
| Max Irradiance | 200 mW/cm² |
| LED Power per Channel | 10 W (optical output: 5.4 W) |
| Spectral Range | 365–980 nm (25 discrete bands + 5 white light CCTs) |
| Light Window Diameter | 12 mm |
| LED Lifetime | >20,000 h |
| Switching Speed | <1 ms (electronic on/off, no mechanical shutter) |
| Control Interface | USB, Bluetooth, analog TTL trigger |
| Software Integration | PSTrace v4.x (compatible with PalmSens4 potentiostat/galvanostat) |
| Compliance | Designed for GLP-compliant photoelectrochemical workflows |
| Brand | REMEX (Xi’an Remex Instrument Co., Ltd.) |
|---|---|
| Origin | Shaanxi, China |
| Model | RFL-II |
| Detector Type | Electrochemical Luminescence Analyzer with Integrated Spectral Photomultiplier Module |
| High-Voltage Power Supply | −100 V to −1000 V (stability ±0.05%, output current ≥5 mA) |
| Gain Settings | 1×, 10×, 100×, 1000× |
| Filter Frequencies | 10 Hz, 20 Hz, 50 Hz, 100 Hz |
| Signal Noise | ≤0.5 mV<sub>P-P</sub> (at 1× gain) |
| Input Impedance | ≥10 MΩ |
| Integration Time Range | 0.01–1000 s |
| Sampling Rate | 1–1000 Hz |
| Spectral Response | 230–920 nm (peak sensitivity at 630 nm) |
| Anode Sensitivity | >2000 A/lm |
| Software Functions | Real-time signal acquisition, auto-zero calibration, AGC (Automatic Gain Control), peak/area quantification, spectral export (TXT), VFD-based local parameter display |
| Brand | dc-energies |
|---|---|
| Diameter | 5 mm (active disk) |
| Overall Outer Diameter | 15 mm |
| Material | High-purity glassy carbon disk, PTFE-insulated shaft, stainless steel or brass housing (configurable) |
| Origin | Hubei, China |
| Instrument Type | Electrochemical Working Electrode Accessory |
| Brand | dc-energies |
|---|---|
| Material Options | Glassy Carbon (GC), Gold (Au), Platinum (Pt) |
| Disk Diameter | 5.0 mm |
| Overall Electrode Outer Diameter | 15 mm |
| Operating Temperature Range | 10–25 °C |
| Brand | dc-energies |
|---|---|
| Disk Diameter | 5.61 mm |
| Ring Outer Diameter | 15.0 mm |
| Material | Glassy Carbon Disk / Platinum Ring |
| Insulator | PTFE Shroud |
| Max Rotation Speed | 3000 rpm |
| Collection Efficiency | 37% |
| Operating Temperature | ≤25 °C |
| Origin | Hubei, China |
| Instrument Type | Electrochemical Working Electrode |
| Brand | DC-Energies |
|---|---|
| Model | RRDE High-Temperature |
| Disk Material | Glassy Carbon |
| Ring Material | Platinum |
| Disk Diameter | 5.61 mm |
| Ring Outer Diameter | 15.0 mm |
| Collection Efficiency | 37% |
| Rotation Speed Range | Up to 3000 rpm |
| Housing Material | PTFE |
| Operating Temperature | Elevated Temperature Capability (Designed for >25°C environments, compatible with thermostatted electrochemical cells) |
| Compliance | ASTM D1308, ISO 13473-2 (Electrode Geometry & Calibration Standards), GLP-Compatible Configuration |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | Schott BlueLine |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SRX-CT23 |
| Price Range | USD 280–690 |
| Instrument Type | Electrochemical Electrode |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | BV-10 |
| Instrument Type | Microelectrode Processing System for Electrophysiology |
| Heating Elements | Pt/Ir wire and Sn-Pb alloy wire |
| Tip Diameter Capability | < 0.3 µm |
| Control | Triple independent digital controllers for heat, pull force, and timing |
| Microscopy | Integrated dual-magnification optical system (low- and high-power objectives) |
| Compliance | Designed for GLP-compliant electrophysiology lab workflows |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MP85 / MP285 / MP-33 |
| Type | Electrochemical Sample Manipulator |
| Axes | 3–4 axis (manual or motorized) |
| Positioning Resolution | Down to 62.5 nm (MP-285/MP-225), 0.2 µm (MP-85 ultra-fine), 0.01 mm (MP-33 fine), 0.1 mm (coarse) |
| Drift | <10 nm/h (MP-285, 24°C), <1 µm/h (MPC-325-2/MPC-385-2) |
| Travel Range | Up to 25 mm (X/Y/Z/oblique), 1 inch (MP-285), 37 × 20 × 20 mm (MP-33 coarse) |
| Control Interface | RS-232 serial, software-driven (XenoWorks™ compatible) |
| Compliance | Designed for GLP/GMP-aligned electrophysiology and electrochemical microelectrode positioning |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-30 |
| Heating Element Options | Platinum-Iridium or Nichrome Coil |
| Control Interface | Three Digital Knobs (Heat, Pull, Velocity) |
| Precision Mechanism | Micrometer-Based Pull Length Reproducibility |
| Electrode Tip Diameter | Down to <0.3 µm |
| Power Supply | Constant-Current Source for Heater and Pull Solenoid |
| Dual-Step Heating Mode | Yes |
| RFI Filtering | Integrated |
| Mounting Base | Rubber-Pad Clamping System |
| Construction Materials | Corrosion-Resistant Alloys and Ceramics |
| Voltage/Frequency Options | Dual (115 V / 230 V |
| Application Domain | Intracellular Electrophysiology, Patch-Clamp Recording, Microinjection, Single-Cell Manipulation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P97 |
| Instrument Type | Electrochemical Micropipette Fabrication System |
| Heating Element | Dual-Loop Resistive Wire (NiChrome or Platinum) |
| Control Architecture | Embedded Microprocessor with Non-Volatile Program Memory |
| Max. Program Storage | 100 Protocols |
| Display | Vacuum Fluorescent Display (VFD), Omnidirectional View |
| Environmental Control | Integrated Humidity-Stabilized Chamber |
| Cooling Options | Pneumatic Blast Cooling (Selectable Mode) |
| Glass Compatibility | Single- and Multi-Barrel Capillaries (OD up to 2.0 mm) |
| Tip Diameter Resolution | Sub-100 nm (Typical for Borosilicate & Aluminosilicate Glass) |
| Compliance | Designed for GLP/GMP-Adjacent Electrophysiology Labs |
| Software Features | Date/Time-Stamped Protocol Logging, Write-Protected Program Mode, Atmospheric Pressure Compensation Parameter |
| Brand | WEP |
|---|---|
| Origin | Germany |
| Model | CVP21 |
| Instrument Type | Electrochemical CV Profiler |
| Carrier Concentration Range | 1×10¹¹ cm⁻³ to 1×10²¹ cm⁻³ |
| Depth Resolution | down to 1 nm |
| Measurable Depth Range | 1 nm – 10 µm |
| Sample Compatibility | Dry-in/Dry-out handling |
| Compliance | ASTM F1391, ISO/IEC 17025-aligned operation, GLP-supporting audit trail |
| Brand | WEP |
|---|---|
| Origin | Germany |
| Model | CVP21_ray |
| Instrument Type | Electrochemical Capacitance-Voltage Profiling System |
| Sample Compatibility | Semiconductor wafers (Si, Ge, SiC, GaN, InP, AlGaN, ZnO, CdTe, HgCdTe, etc.) |
| Carrier Concentration Range | 1×10¹¹ to 1×10²¹ cm⁻³ |
| Depth Resolution | Down to ≤1 nm |
| System Architecture | Modular, cleanroom-compatible, fully automated electrochemical etching & CV scanning platform |
| Software Control | Integrated real-time etch monitoring, CV sweep automation, profile reconstruction, GLP-compliant data logging |