Elemental Analyzer
Filter
Showing 301–330 of 531 results
| Brand | AMS |
|---|---|
| Origin | Beijing, China |
| Model | NexaFlo™ |
| Configuration | Up to 14 independent analytical channels |
| Detection Principles | Continuous Flow Analysis (CFA) with segmented flow, online pre-treatment (dialysis, UV digestion, distillation, heating, dilution, mixing, extraction) |
| Detector Options | UV-Vis spectrophotometer, flame photometer (for K⁺/Na⁺), fluorimeter |
| Display | 7-inch color touchscreen (NexaFlo™ 450 variant) |
| Automation | Fully programmable CFA software with auto-startup/shutdown, QC control, auto-dilution, LIMS export, and audit-trail-capable operation |
| Compliance | Designed to support ASTM D129, ISO 11905-1, USP <621>, EPA Methods 353.2, 354.1, 365.2, and GLP/GMP-aligned data integrity practices |
| Sample Handling | Dual-probe autosampler optional |
| Fluidics | High-precision three-speed peristaltic pumps |
| Reagent Management | Integrated sealed reagent reservoirs with vapor/leak mitigation |
| Brand | NEXOPART |
|---|---|
| Origin | Germany |
| Model | HAVER CPA 2-1HR |
| Measurement Range | 20 µm – 30 mm |
| Power Supply | 230 V / 115 V, 50/60 Hz |
| Feeder Width | 55 mm |
| Camera | CMOS, 2927 px horizontal resolution, 100 MHz pixel clock |
| Light Source | LED |
| Interface | GigE Vision, USB, BUS-Extension |
| Dimensions | 810 × 200 × 400 mm (L×W×H) |
| Weight | 21 kg |
| Brand | Nippon Instruments Corporation (NIC) |
|---|---|
| Origin | Japan |
| Model | WA-5A |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) with Dual Gold Amalgamation |
| Detection Limit | 0.001 ng (1 pg) |
| Linear Range | 0.001 – 1000 ng |
| Compliance | ASTM D5954-98(2014)e1, ISO 6978-2:2005, ISO 20552, JIS K 0312, HJ 910–2017, GB 16781.2–2010, HJ 597–2011, HJ 543–2009 |
| Sample Forms | Gaseous matrices (ambient air, natural gas, shale gas, LPG, LNG, hydrogen), aqueous samples (with S-MA/AQUA accessory) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 1030 |
| Price Range | USD 1,400 – 7,200 |
| Detection Range | 2 ppb C to 30,000 ppm C |
| Oxidation Methods | Acid-Persulfate Oxidation (Heated) & High-Temperature Catalytic Combustion (680–950 °C) |
| Detection Technology | Solid-State Non-Dispersive Infrared (SS-NDIR) |
| Compliance | EPA Method 415.3, ASTM D5905, D7573, USP <643>, ISO 8245 |
| Sample Types | Liquid aqueous matrices only (ultrapure water, PW, WFI, wastewater, seawater, process streams) |
| Optional Modules | POC, TNb, Solid TOC, Autosampler, Online Sampling Interface |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DC2000 |
| Detector Type | Si-PIN |
| Excitation Source | Microfocus X-ray Tube (8–40 kV) |
| Cooling System | Peltier Thermoelectric (operable down to −35 °C) |
| Filter Set | 8-position automatic filter changer |
| Display | High-resolution Blanview transmissive backlight color touchscreen |
| Dimensions | 245 × 250 × 88 mm |
| Weight | <1.5 kg |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% (non-condensing) |
| Battery | Dual hot-swappable Li-ion batteries |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 2.1 (Microsoft-compatible stack) |
| OS | Windows CE 6.0 |
| Compliance | Meets IEC 61000-4 EMC standards |
| Sample Compatibility | Solid metals, welds, castings, forgings, and scrap alloys up to 480 °C surface temperature |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO200 |
| Detector | 25 mm² SDD Silicon Drift Detector |
| Excitation Source | Micro-focus X-ray Tube (8–40 kV) |
| Cooling System | Peltier Thermoelectric Cooling (operable down to −35 °C) |
| Filter Set | 8-position automatic filter changer |
| Display | High-resolution transflective color touchscreen |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to 50 °C |
| Relative Humidity | 0–95% non-condensing |
| Battery | Dual hot-swappable Li-ion batteries |
| Data Storage | SD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth v2.1 + EDR |
| OS | Windows CE 6.0 |
| Software | Olympus Delta PC Suite (remote control, report generation, spectral review) |
| Brand | Olympus |
|---|---|
| Origin | USA |
| Model | DPO4050 |
| Detector | 25 mm² Silicon Drift Detector (SDD) |
| Excitation Source | High-Power Micro-Focus X-ray Tube (15–50 kV) |
| Cooling System | Peltier Thermoelectric Cooler (operable down to −35 °C) |
| Filter Set | 8-position Automatic Filter Wheel |
| Weight | <1.5 kg |
| Dimensions | 245 × 250 × 88 mm |
| Operating Temperature | −10 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Battery | Dual Hot-Swappable Li-ion Batteries |
| Display | High-Resolution Transflective Color Touchscreen |
| Data Storage | MicroSD card (≥100,000 spectra) |
| Connectivity | USB 2.0, Bluetooth 4.0 (Microsoft Mobile Device Center compatible) |
| Operating System | Windows CE 6.0 |
| Analysis Modes | Up to 25 User-Configurable Calibration Modes |
| Light Element Compensation | Integrated Barometric Pressure Sensor & Accelerometer for Atmospheric Correction |
| Brand | OPISIS |
|---|---|
| Origin | Sweden |
| Model | KD-200 |
| Instrument Type | Kjeldahl Distillation Unit |
| Automation Level | Semi-Automatic (Distillation Only) |
| Nitrogen Range | 0.05–240 mg N |
| Distillation Time | 2–4 min/sample |
| Repeatability | RSD ≤ ±0.5% |
| Sample Weight Capacity | ≤5 g (solid) or ≤20 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 430 mm × 330 mm × 700 mm |
| Weight | 30 kg |
| Brand | OPIS / OPSIS |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | KD-200 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.05–240 mg N |
| Distillation Time | 2–4 min per sample |
| Repeatability | RSD ≤ ±0.5% |
| Sample Weight Capacity | Solids ≤ 5 g, Liquids ≤ 20 mL |
| Recovery Rate | ≥ 99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 430 mm × 330 mm × 700 mm |
| Brand | OPSEUS / OPISIS |
|---|---|
| Origin | Sweden |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | KD-210 |
| Instrument Type | Potentiometric Titration-Based Kjeldahl System |
| Automation Level | Semi-Automated Kjeldahl Distillation Unit |
| Nitrogen Range | 0.05–240 mg N per sample |
| Distillation Time | 2–4 min/sample |
| Repeatability | RSD ≤ ±0.5% |
| Sample Weight Capacity | ≤5 g (solid) or ≤20 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 430 mm × 330 mm × 700 mm |
| Brand | OPSIS |
|---|---|
| Origin | Sweden |
| Model | KD-310 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.05–240 mg N |
| Distillation Time | 2–4 min per sample |
| Repeatability | RSD ≤ 0.5% |
| Sample Weight Capacity | ≤ 5 g (solid) or ≤ 20 mL (liquid) |
| Recovery Rate | ≥ 99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 430 mm × 330 mm × 700 mm |
| Brand | OPISIS |
|---|---|
| Country of Origin | Sweden |
| Model | KD-625 |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.05–240 mg N |
| Distillation Time | 2–4 min per sample |
| Repeatability | ≤ ±0.5% RSD |
| Sample Weight Capacity | ≤5 g (solid) or ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2300 W |
| Dimensions (L×W×H) | 930 × 1610 × 730 mm |
| Titration Precision | 1.95 µL |
| Sample Capacity | 25 × 250 mL digestion tubes (standard autosampler), optional 65-position or 400 mL tube configurations |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecLive |
| Detector Active Area | Up to 170 mm² |
| Maximum Quantitative Count Rate | 400 kcps |
| Maximum Mapping Count Rate | 1,000 kcps |
| Detector Type | Silicon Drift Detector (SDD) with Extreme Electronics Architecture |
| Compliance | Designed for integration with field-emission and tungsten SEM platforms per IEC 61000-4 EMC standards |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SKD-100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 3–8 min per sample |
| Repeatability | RSD ≤ 0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Display | LED digital display |
| Alkali Addition Time | 0–99 s |
| Distillation Volume Control | 14–28 mL/min |
| Programmable Programs | 10 pre-set distillation/alkali addition protocols |
| Safety Features | Overpressure protection, dry-run prevention via real-time liquid level monitoring, emergency stop function |
| Housing Material | Integrated molded ABS engineering plastic |
| Tubing Material | PEIOU proprietary acid-/alkali-/heat-resistant polymer tubing |
| Weight | 15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply Requirement | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | ≤5 g (solid) / ≤15 mL (liquid) per sample |
| Alkali/Acid Addition Time Control | 0–99 s (segmented) |
| Distillation Time Setting | 0–99 min |
| Distillation Rate | 14–28 mL/min |
| Power Adjustment Range | 750–1500 W |
| Recovery Rate | >99.5% |
| Repeatability | RSD ≤0.5% |
| Dimensions (L×W×H) | 370×300×680 mm |
| Net Weight | 15 kg |
| Display | LED digital |
| Data Storage | 10 programmable distillation/alkali addition methods |
| Safety Features | Real-time liquid level monitoring, overpressure protection, dry-run prevention, emergency stop |
| Housing Material | Molded ABS engineering plastic (acid/alkali resistant) |
| Tubing | PEIU proprietary corrosion-resistant high-temp tubing |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply Requirement | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SKD-100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Measurement Range | 0.1–240 mg N |
| Distillation Time | 3–8 min per sample |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | Solids < 6 g, Liquids < 16 mL |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Rating | 1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-1000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–200 mg N per sample |
| Distillation Time | 3–8 min per sample |
| Repeatability | ≤ ±0.5% RSD |
| Sample Weight Capacity | Solids 0.1–2 g |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | ~1500 W |
| Dimensions (L×W×H) | 450 × 400 × 550 mm |
| Linear Range | 0.1–200 mg N |
| Linearity Error at 4× Nitrogen Load | ≤ ±1% |
| Compatible Standard Acid Concentrations | 0.01–0.5 mol/L HCl or H₂SO₄ |
| Titration Resolution | 0.8 µL/step |
| Acid Delivery Precision | ≤0.002 µL/step |
| Alkali Addition | Programmable segmented dosing (1–10 pulses, 0–15 s interval) |
| Delay Time Setting | 0–1800 s (for nitrate-nitrogen analysis) |
| Reagent Pump Volume Range | 0–150 mL (1 mL increments) |
| Steam Power Adjustment | Continuously variable |
| Safety Features | Dual-level steam chamber monitoring, condensate flow interruption protection, door interlock sensing, real-time cooling water pressure/flow detection, reagent level monitoring, and jacket temperature control |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-1000 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N per sample |
| Distillation Time | 3–8 min/sample |
| Repeatability | RSD ≤ 0.5% |
| Sample Weight Capacity | ≤6 g (solid) or ≤20 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Dimensions (L×W×H) | 500 × 350 × 720 mm |
| Titration Resolution | 0.8 µL/step (auto-adjusted by titrant concentration) |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-1100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–200 mg N |
| Linear Range | 0.1–200 mg N |
| Sample Weight (Solid) | 0.1–5 g |
| Distillation Time per Sample | 3–5 min |
| Repeatability | ≤0.5% CV |
| Recovery Rate | ≥99.5% |
| Power Consumption | ~800 W |
| Dimensions (L×W×H) | 450 × 350 × 500 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-180 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Measurement Range | 0.1–240 mg N |
| Distillation Time Setting | 0–99 min |
| Repeatability | RSD ≤ 0.5% |
| Sample Capacity | Solid ≤ 20 g/sample |
| Nitrogen Recovery Rate | > 99.5% |
| Adjustable Power Output | 1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-1800 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg |
| Distillation Time per Sample | 3–8 min |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | ≤5 g (solid) or ≤15 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 750–1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Linearity Range | 0.1–240 mg nitrogen |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-2000 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–300 mg N |
| Sample Weight Capacity | Solids 0.1–5 g |
| Distillation Time per Sample | 2–6 min |
| Repeatability | ≤ ±0.3% RSD |
| Recovery Rate | ≥99.8% |
| Linearity Range | 0.1–300 mg N |
| Linearity Error at 4× Nitrogen Load | ≤ ±0.8% |
| Compatible Standard Acid Concentration | 0.01–1.0 mol/L HCl or H₂SO₄ |
| Power Consumption | ~1800 W |
| Dimensions (L×W×H) | 500×450×600 mm |
| Titration Precision | ±0.15% |
| Adjustable Alkali Addition Steps | 1–10 segments with 0–15 s intervals |
| Delay Time Setting | 0–1800 s |
| Reagent Pump Volume Range | 0–150 mL (1 mL resolution) |
| Distillation Steam Continuity | Continuous steam generation with auto-refill without interruption |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-2000 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time per Sample (incl. titration) | 3–8 min |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | ≤6 g (solid), ≤16 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 750–1500 W |
| Dimensions (L×W×H) | 500 mm × 350 mm × 720 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-3000 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Throughput | 1 sample per 3–8 min |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Dimensions (L×W×H) | 500 × 350 × 720 mm |
| Titration Resolution | ≤0.001 µL/step |
| Minimum Titration Volume | 0.8 µL/step (auto-adjusted per titrant concentration) |
| Distillation Flow Rate | 15–30 mL/min (adjustable) |
| Data Storage | Unlimited (on-board + wireless PC sync) |
| Compliance | Designed for GLP/GMP-aligned workflows with audit trail, user-level access control (3-tier password), and full data traceability |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-5000 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Determinator |
| Nitrogen Determination Range | 0.1–500 mg N per sample |
| Cation Exchange Capacity (CEC) Range | 1–100 cmol/kg |
| Sample Weight | Solid (e.g., soil): 0.5–10 g |
| Liquid | 1–100 mL |
| Distillation Time | 2–5 min per sample |
| Repeatability | ≤±0.2% for nitrogen |
| Recovery Rate | ≥99.8% for nitrogen |
| Linear Range | 0.1–500 mg N |
| Linearity Error at 4× Nitrogen Load | ≤±0.5% |
| Compatible Standard Acid Concentration | 0.01–1.5 mol/L HCl or H₂SO₄ |
| Power Consumption | ~2000 W |
| Dimensions (L×W×H) | ~550×500×650 mm |
| Titration Resolution | 0.8 µL/step |
| Pump Accuracy | RSD <0.002 µL/step |
| Repeatability (RSD) | <0.5% |
| Delay Time Setting | 0–1800 s |
| Digestion Tube Compatibility | 300 mL and 650 mL tubes |
| Dual-Mode Operation | Manual & Automatic |
| Distillation Power | Adjustable |
| Safety Features | Real-time distillation cup temperature monitoring, condenser water flow/pressure auto-detection, acid/alkali/boric acid/diluent level sensors, door-closed status verification, dry-burn prevention via dual liquid-level modeling |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-5000 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Determinator |
| Nitrogen Range | 0.1–240 mg N |
| CEC Range | 0.07–140 cmol<sub>c</sub>/kg |
| Digestion/Steam Distillation Time | 3–8 min per sample |
| Repeatability | RSD ≤ 0.5% |
| Sample Capacity | ≤6 g (solid) or ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Dimensions (L×W×H) | 500 × 350 × 720 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-800 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automated |
| Nitrogen Determination Range | 0.08–240 mg N |
| Sample Weight Capacity | Solid ≤6 g, Liquid ≤16 mL |
| Distillation Time | 3–8 min (typical) |
| Repeatability | RSD < 0.5% |
| Recovery Rate | ≥99.5% |
| Adjustable Distillation Power | 750–1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Cooling Water Flow Requirement | >1.5 L/min (inlet water temperature ≤20 °C) |
| Operating Pressure | >0.15 MPa |
| Data Storage | ≥100 distillation programs, ≥1000 sample records |
| Safety Features | Dual-level liquid detection, real-time temperature monitoring (digestion cup & collector), door-closed status sensing, intermittent alkali addition, automatic reagent dosing (acid, alkali, boric acid, diluent), overheat protection, dry-run prevention, and coolant flow interruption detection |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-800 |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.08–240 mg N |
| Distillation Time per Sample | 3–8 min |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | Solids < 6 g |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Rating | 1500 W (adjustable) |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SKD-800 |
| Price Range | USD 2,800 – 7,200 (FOB Shanghai) |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Semi-Automatic |
| Nitrogen Measurement Range | 0.08–240 mg N |
| Distillation Time | 1–99 min |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | Solids ≤ 5 g, Liquids ≤ 15 mL |
| Nitrogen Recovery Rate | > 99.5% |
| Adjustable Distillation Power | 1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD200 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 3–8 min |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | 99.5% |
| Adjustable Distillation Power | 1500 W |
| Dimensions (L×W×H) | 370 × 300 × 680 mm |