| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Niton XL5 Plus XRF |
| Application | Handheld / Portable |
| Industry Use | General Purpose |
| Elemental Range | Mg–U (with ultra-low-light detection), Na (via spectral detection) |
| Analyzable Elements | >30 common elements |
| Primary Applications | Rapid alloy identification, ultra-trace light-element detection |
| Energy Resolution | 150–185 eV |
| Detector | High-count-rate, high-resolution, large-area silicon drift detector (SDD) with 1 µm graphene window and integrated detector protection |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Niton XL5 Plus |
| Price Range | USD 42,000 – 70,000 |
| Form Factor | Handheld / Portable |
| Regulatory Compliance | ASTM E1621, ISO 13322-2, IEC 62596, RoHS/WEEE Directive Annex II, CPSIA Section 101, EN 71-3, EU REACH SVHC Screening |
| Brand | Thermo Fisher |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Niton™ XL5 Plus |
| Price | Upon Request |
| Detector Type | High-Count-Rate, High-Resolution, Large-Area Silicon Drift Detector (SDD) with 1 µm Graphene Window and ProGuard Protection |
| X-ray Source | Silver-Anode X-ray Tube (6–50 kV, 0–500 µA, up to 5 W) |
| Beam Spot Size | Standard 8 mm |
| Filtration | 6-Position Filter Wheel |
| Sample Interface | Micro & Macro Cameras, Reversible Scattering Shield Support, Optional Soil Guard Sleeve |
| Display | Tilt-Adjustable Color Resistive Touchscreen |
| Weight | 1.3 kg (2.8 lb) with Battery |
| Dimensions (L×W×H) | 24.23 × 20.8 × 6.78 cm (9.54 × 8.19 × 2.67 in) |
| Environmental Rating | IP54 (Dust-Resistant & Splash-Protected) |
| Operating Temperature | 0–50 °C (External fan recommended above 33 °C) |
| Relative Humidity | 10–90% RH (non-condensing) |
| Power | Hot-Swappable 12 V Li-ion Battery or 12 V DC/3 A Input |
| Data Storage | 512 MB RAM / 16 GB Industrial-Grade Flash (≈130,000 spectra + metadata |
| Connectivity | Wi-Fi, USB-C, Bluetooth (optional GPS, barcode scanner) |
| Software | NitonConnect PC Software with Audit Trail, Report Generation, and Library Management |
| Compliance | CE, RoHS, FCC, ISED (Canada), IEC 61010-1:2010 |
| Safety | Password-Protected User Access, Interlock Logic, Real-Time Dose Monitoring, Regulatory Licensing Support per Regional Authority |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | TrueX 2020G |
| Form Factor | Handheld / Portable |
| Instrument Type | Conventional EDXRF Spectrometer |
| Application Scope | General-Purpose Elemental Analysis |
| Elemental Range | Al (13) to U (92) |
| Quantitative Detection Range | 1 ppm – 99.99 wt% |
| Energy Resolution | < 140 eV at Mn Kα |
| Repeatability (RSD) | ≤ 0.1% for major elements under standardized conditions |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMX |
| Element Range | Na (11)–U (92) |
| Detection Range | 0.1 ppm–99.99% |
| Energy Resolution | <100 eV (@5.89 keV) |
| Repeatability (RSD) | ≤0.05% |
| Detector | FAST SDD (Silicon Drift Detector) |
| Sample Capacity | 25-position automated carousel |
| Measurement Time | 100–300 s per sample |
| Vacuum Level | 1×10⁻² Pa (stable for ≥30 min) |
| X-ray Tube | 0–50 kV, 1–1000 µA |
| Sample Mass | 3–8 g |
| Dimensions (L×W×H) | 970×750×1600 mm |
| Weight | 160 kg |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMG |
| Element Range | Na (11)–U (92) |
| Detection Limit | 0.1 ppm |
| Quantification Range | 0.1 ppm–99.99% |
| Energy Resolution | <100 eV (@5.89 keV) |
| Repeatability (RSD) | ≤0.05% |
| Detector | FAST SDD (Silicon Drift Detector) |
| Sample Chamber | Top-illumination geometry with vacuum capability (10⁻²–10⁻⁵ Pa) |
| X-ray Tube | 0–50 kV, 1–1000 µA |
| Measurement Time | 100–300 s |
| Sample Mass | 3–8 g |
| Dimensions | 750 × 670 × 1620 mm (D×W×H) |
| Weight | 135 kg |
| Compliance | GBZ 115–2002, registered with Ministry of Ecology and Environment of PRC |
| Brand | Sichuan Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SYB |
| Detector | Si(PIN) Semiconductor (Cryogenically Cooled) |
| X-ray Tube | 40 kV Tungsten Target Microfocus Source |
| Energy Resolution | <150 eV @ Mn Kα |
| Analytical Range | Na (11) to U (92) |
| LOD | Cd/Cr/Hg/Br ≤1 ppm, Pb ≤2 ppm, Cl ≤20 ppm |
| Measurement Range | 1–40 keV |
| High Voltage | 0–40 kV |
| Tube Current | 0–100 µA |
| Sample Chamber | Vacuum-Compatible Circular Cavity (Ø140 mm × H50 mm) |
| Measurement Time | 120–600 s |
| Power Supply | AC 220 V ±1%, 50 Hz, 1000 VA |
| Dimensions | 500 × 500 × 450 mm |
| Weight | 25 kg |
| Operating Temp. | 0–35 °C |
| Relative Humidity | ≤99% RH (non-condensing) |
| Rated Power | 50 W |
| Calibration Standard | Certified EU RoHS Reference Materials |
| Brand | Xenemetrix |
|---|---|
| Origin | Israel |
| Model | EX-6600 / X-7600 |
| Configuration | Benchtop & Floor-standing |
| Elemental Range | C(6)–Fm(100) |
| Detection Limit | 1 ppm |
| Concentration Range | 1 ppm – 100% |
| Energy Resolution | 129 eV (FWHM at 5.9 keV) |
| Repeatability | 0.1% |
| X-ray Tube | Rh anode, 60 kV / 300 W (EX-6600), 60 kV / 400 W (X-7600) |
| Detector | Silicon Drift Detector (SDD), standard or LE variant |
| Filter Set | 8-position motorized primary filters |
| Secondary Targets | 8 selectable targets |
| Sample Environment Options | Air, Vacuum, He purge |
| Sample Chamber Dimensions | Ø178 mm × H32 mm |
| Instrument Dimensions (L×W×H) | 85 × 85 × 105 cm (EX-6600), 85 × 85 × 105 cm (X-7600) |
| Weight | 170 kg (EX-6600), 220 kg (X-7600) |
| Software | nEXt™ quantitative analysis suite with fundamental parameters (FP) algorithm |
| Brand | Xenemetrix |
|---|---|
| Origin | Israel |
| Model | S-Mobile PD/SDD |
| Element Range | C(6)–Fm(100) |
| Detection Limit | sub-ppm |
| Energy Resolution | <130 eV (FWHM at 5.9 keV) |
| Repeatability | 0.1% |
| X-ray Tube | Rh anode, 50 kV / 50 W |
| Detector Options | Peltier-cooled PIN diode or Silicon Drift Detector (SDD) |
| Sample Chamber Dimensions | 121 × 112 × 45 cm |
| Weight | 25 kg |
| Compliance | ASTM D4294, D7217, ISO 20847, IP 531 |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SME |
| Element Range | Na (11) – U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | 100 eV (at Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Detector | Silicon Drift Detector (SDD), Peltier-cooled |
| Excitation Source | Ag-anode microfocus X-ray tube, Be window (50 µm), 0–50 kV / 1–1000 µA adjustable |
| Measurement Atmosphere | Air or vacuum (down to 10⁻² Pa) |
| Sample Form | Powdered solids |
| Multi-channel Analyzer | 2048-channel digital MCA |
| Simultaneous Elements | ≥30 |
| Analysis Time | 60–180 s per sample |
| Dimensions | 650 × 600 × 730 mm |
| Weight | 65 kg |
| Brand | Xinxianda |
|---|---|
| Model | CIT-3000SMP |
| Detector | Si(Li) semiconductor, energy resolution ≤150 eV (at 5.9 keV, ⁵⁵Fe) |
| Excitation Source | Miniature air-cooled X-ray tube |
| Measurable Elements | S, P, Ca, Ti, V, Mn, Fe, Ni, Cu, Zn, Mo, As, Sn, W |
| Detection Range | 0.001–99.99 wt% |
| Measurement Time | <200 s |
| Operating Voltage Range | 2–30 keV |
| Power Consumption | 4 W |
| Weight | 1.75 kg |
| Battery Life | ≥8 h (full-load operation) |
| Data Interface | Bluetooth, GPS, USB |
| Safety Indicators | Dual-color LED (green = power on |
| Compliance | CE, RoHS, IEC 61010-1, IEC 62471 |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SMQ |
| Element Range | Na (11)–U (92) |
| Concentration Range | 1 ppm – 99.99% |
| Energy Resolution | ≤125 eV (Mn Kα) |
| Repeatability | ≤0.1% RSD |
| Operating Voltage | 0–25 kV |
| Tube Current | 1–1000 µA |
| Measurement Time | 60–120 s per sample |
| Vacuum Capability | Yes |
| Detector | Peltier-cooled Si-PIN semiconductor |
| Energy Range | 1–30 keV |
| Simultaneous Elements | Up to 9 |
| Sample Mass | 10–15 g |
| Radiation Dose Rate | <25 µSv/h |
| Ambient Temp. | 10–35 °C |
| Humidity | 30–70% RH |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | Xinxianda |
|---|---|
| Origin | Sichuan, China |
| Model | CIT-3000SY |
| Form Factor | Benchtop/Floor-standing |
| Application Domain | Geological & Petrological Core Logging |
| Elemental Range | Na–U |
| Quantification Range | 1 ppm – 99.99% |
| Energy Resolution | ≤100 eV (at Mn Kα, 5.9 keV) |
| Repeatability | RSD ≤0.05% (major elements, n=5) |
| Brand | Xinxianda |
|---|---|
| Model | CIT-3000SYE |
| Origin | Sichuan, China |
| Detector Energy Resolution | <130 eV |
| Elemental Range | Na (Z=11) to U (Z=92) |
| Detection Limit | 1 ppm |
| Analysis Time | 120 s (auto-optimized) |
| Operating Voltage | 0–40 kV |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions | 740 × 450 × 430 mm |
| Weight | ~55 kg |
| Sample Chamber | Ø300 × 100 mm (downward illumination) |
| Vacuum Capability | Yes |
| Software | Proprietary Windows-based EDXRF analysis suite with FP, empirical coefficient, and α-factor quantification methods |
| Compliance Support | ASTM E1621, ISO 8256, IEC 62321-5 for RoHS, GLP-ready audit trail & user access control |
| Brand | XOS |
|---|---|
| Model | Petra 4294 |
| Element Range | Sulfur (S) |
| Detection Limit | 2.6 ppm @ 600 s |
| Quantification Range | 2.6 ppm – 10 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤2% RSD |
| Detector | Silicon Drift Detector (SDD) |
| Sample Format | Liquid or solid in disposable cups (vertical loading) |
| Compliance | ASTM D4294, ISO 8754, IP 336, GB/T 17040, GB/T 17606 |
| Power Requirement | Standard AC outlet (no gas, no combustion, no high-temperature operation) |
| Measurement Time | Adjustable from 30 to 900 seconds |
| Sample Volume | ≤10 mL |
| Footprint | Benchtop configuration with integrated drip tray and spill containment |
| Brand | XOS |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop/Lab-Floor Standing |
| Configuration | Standard Model |
| Application Sector | Energy & Petrochemicals |
| Elemental Range | S, P, Cl, K, Ca, V, Cr, Mn, Fe, Co, Ni, Cu, Zn |
| Quantification Range | 5.7 ppm – 10 wt% |
| Energy Resolution | <140 eV (Mn Kα) |
| Repeatability | ≤2% RSD (at 100 ppm level) |
| Detector | Silicon Drift Detector (SDD) |
| Brand | ZYKX |
|---|---|
| Model | ZY-2800B |
| Origin | Beijing, China |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose ED-XRF |
| Elemental Range | S (16) to U (92) |
| Detection Limit (Cd, Pb, Cr, Hg, Br) | ≤1 ppm |
| Measurement Time | 100–300 s |
| Energy Resolution | 149 ± 5 eV (at Mn Kα) |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 40–50 % RH |
| Power Supply | AC 220 V ±5 V, 50/60 Hz |
| Detector | Silicon PIN (Si-PIN), Peltier-cooled |
| X-ray Tube | Air-cooled, 50 W, max. 50 kV / 1 mA |
| Multichannel Analyzer | 2048 channels |
| Collimator Options | 8 apertures (0.2–8 mm) |
| Filter Options | 6 automatic filter positions |
| Interface | USB 2.0 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | ZY8000H |
| Configuration | Benchtop/Floor-standing |
| Application Type | General-purpose |
| Elemental Range | Na (11) to U (92) |
| Detection Limit | 1 ppm for RoHS elements (Cd, Pb, Cr, Hg, Br, Cl) |
| Energy Resolution | 129 ± 5 eV (at Mn Kα) |
| Measurement Time | 100–300 s (user-adjustable) |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 40–70 % RH |
| Power Supply | AC 220 V ±5 V, 50 Hz |
| Vacuum System | Integrated auto-vacuum pump (60 L/min pumping speed |
| Detector | Silicon Drift Detector (SDD), Peltier-cooled |
| Signal Processing | Digital multi-channel analyzer (4096 channels), SES proprietary algorithm |
| Collimator Options | 7 automatic sizes (2–8 mm diameter) |
| Filter Options | 5 programmable filters |
| Collimator–Filter Combinations | >30 preconfigured configurations |
| Software | Vacuum-enabled EDXRF analysis suite with auto-curve selection, real-time vacuum monitoring, spectral overlay, GLP-compliant audit trail, and dual-language UI (English/Chinese) |