Environmental Monitoring Instruments
Filter
Showing 5671–5700 of 9112 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FG4 |
| Measurement Principle | Galvanic Cell (Zero-Polarization) |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.3 °C |
| DO Range (%) | 0.00–199.9% (extended to 400%) |
| DO Range (mg/L & ppm) | 0.0–45.0 mg/L (ppm) |
| DO Resolution | 0.1% / 0.01 mg/L / 0.01 ppm |
| DO Accuracy | ±1% of reading or ±1 mg/L (whichever is greater) |
| Salt Range | 0.0–50.0 ppt (0.1 ppt resolution) |
| Atmospheric Pressure Range | 375–825 mmHg / 500–1100 mbar / 500–1100 hPa |
| Pressure Resolution | 1 unit |
| Calibration Points | 2-point (0% and 100% O₂) |
| Data Storage | 30 measurements |
| Display | Backlit LCD with simultaneous readout of DO value, temperature, endpoint status, and compensation indicators |
| Enclosure Rating | IP54 |
| Power Supply | 4 × 1.5 V AAA batteries |
| Operating Environment | 0–40 °C, 5–80% RH (non-condensing) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Online DO Analyzer |
| Measurement Principle | Optical Luminescence Quenching (ISO 5814:2012 compliant) |
| Range | 0.00–80.00 mg/L (0– saturation, 0–50 ppm, 0–50,000 ppb) |
| Accuracy | ±0.2 mg/L at 25°C |
| Repeatability | ≤0.05% of reading |
| Detection Limit | <2 ppb (in high-purity water mode) |
| Sensor Technology | ISM® (Intelligent Sensor Management) enabled |
| Compliance | FDA 21 CFR Part 11 ready, USP <1231>, ASTM D888, ISO 5814, EN 25814 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | S30K (S30) |
| Conductivity Range | 0.01 µS/cm to 500 mS/cm (auto-ranging) |
| Temperature Range | –5.0 to 105.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Conductivity Accuracy | ±0.5% of reading |
| Salt Range | 0.00–80.00 ppt |
| TDS Range | 0.1 mg/L–500 g/L |
| Electrode Constant | User-definable |
| Display | LCD with multi-parameter readout |
| Power | External AC adapter or 4× AA (LR6) batteries |
| Auto-Temperature Compensation (ATC) | Yes |
| Endpoint Detection | Auto-hold with stability-based locking |
| Buffer Recognition | Automatic buffer ID during calibration |
| Compliance | Designed for GLP-compliant workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S4, S9 |
| Portability | Portable |
| Measurement Principle | Polarographic (Clark-type) or Optical (Luminescence-based) — configurable per probe |
| Measurement Range | 0.00–50.0 mg/L (ppm) |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–50 mg/L) |
| Repeatability | ±0.05% of reading |
| Detection Limit | ±2 ppb (O₂ in water) |
| Ingress Protection | IP67 |
| Electrode Compatibility | ISM® (Intelligent Sensor Management) enabled |
| Data Interface | Waterproof USB (IP67-rated) |
| Display | High-contrast, sunlight-readable LCD with StatusLight™ indicator |
| Language Support | 12 languages including English, German, French, Spanish, Chinese, Japanese, Korean, etc. |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | S900 |
| Instrument Type | Portable |
| Measurement Range | 0–50 mg/L |
| Accuracy | ±0.1 mg/L |
| Repeatability | ±0.05 mg/L |
| Detection Limit | 0 mg/L |
| Sensor Interface | Digital (InLab® OptiOx) |
| Channel Configuration | Single-channel, modularly expandable |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | SG9 |
| Instrument Type | Laboratory-Portable |
| IP Rating | IP67 |
| Measurement Principle | Optical Luminescence (RDO® Technology) |
| DO Range | 0.00–80.00 mg/L (ppm) |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.1 mg/L (0–8 mg/L), ±0.2 mg/L (8–20 mg/L), ±10% (20–80 mg/L) |
| Saturation Range | 0.0–50.0% |
| Saturation Resolution | 0.1% |
| Barometric Pressure Range | 500–1100 mbar |
| Pressure Resolution | 0.1 mbar |
| Data Storage | 500 GLP-compliant records |
| Calibration Management | ISM® Intelligent Sensor Management |
| Sensor Interface | Digital ISM-enabled OptiOx probe |
| Communication | Infrared (IR) interface |
| Operating Modes | Standard / Expert |
| Endpoint Options | Auto, Manual, Timed |
| Compliance | GLP, ISO/IEC 17025-supporting workflows, FDA 21 CFR Part 11-ready (with optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | SG6 |
| Temperature Range | 0.0–60.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Dissolved Oxygen Range | 0.0–600 % saturation / 0.00–99.00 mg/L |
| DO Resolution | 0.1–1 % / 0.01 mg/L |
| DO Accuracy | ±0.5 % |
| Atmospheric Pressure Range | 500–1100 mbar |
| IP Rating | IP67 |
| Data Storage | 200 GLP-compliant records |
| Display | Backlit custom LCD |
| Power Supply | 4 × AA alkaline or rechargeable batteries |
| Operating Environment | 5–40 °C, 5–80 % RH (non-condensing) |
| Interface | Infrared (IR) for data transfer to printer or PC (RS232/USB via optional adapter) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Line | SevenGo Series |
| Portability | Handheld / Field-Deployable |
| IP Rating | IP67 |
| Display | Backlit LCD (Professional Models) |
| Connectivity | Infrared (IR) Interface (Professional Models) |
| Data Management | Onboard Storage + PC Export via ErGo Assistant Software |
| Form Factor | Modular Electrochemical Meter Platform |
| Compliance | Designed for ASTM D1293, ISO 7888, ISO 5814, USP <645>, and EPA Method 120.1 / 120.2 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 2300Na |
| Measurement Range | 0.001–100,000 ppb Na⁺ |
| Calibration | Unattended 3-point incremental or manual 1-/2-point |
| Dimensions | 900 × 450 × 190 mm |
| Analog Outputs | (4) 0/4–20 mA |
| Electrode Activation | Automatic during calibration |
| Enclosure Options | Fully enclosed locked cabinet or semi-enclosed with service door |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 2800Si |
| Detection Limit | 0.8 ppb |
| Measurement Range | 0–5000 ppb |
| Accuracy | ±5% of reading or ±1 ppb (whichever is greater) |
| Cycle Time | Adjustable, typically 20 minutes |
| Maximum Sample Pressure | <7 bar (100 psig) |
| Compliance | Designed for ASTM D4582, ASTM D5116, ISO 14687-2, and power plant water chemistry guidelines per EPRI TR-102328 & IAPWS RP-7 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 4000TOCe |
| Instrument Type | Online TOC Analyzer |
| Measurement Principle | Direct Conductivity Detection |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05–1000 ppb C |
| Accuracy | ±0.1 ppb (TOC < 2 ppb) |
| Resolution | 0.001 ppb |
| Detection Limit | 0.025 ppb |
| Repeatability | ±0.05 ppb (<5 ppb) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 450TOC |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185 nm) |
| Measurement Range | 0.05 – 1000 ppb C (μg C/L) |
| Accuracy | ±0.1 ppb C for TOC < 2.0 ppb |
| Resolution | 0.001 ppb C (μg C/L) |
| Detection Limit | 0.025 ppb C |
| Repeatability | ±0.05 ppb C (< 5 ppb), ±1.0% (> 5 ppb) |
| Sample Temperature | 0–70 °C |
| Particle Size Limit | < 100 µm |
| Conductivity Requirement | ≥0.5 MΩ·cm (≤2 µS/cm) |
| pH Limit | < 7.5 |
| Flow Rate | 20 mL/min |
| Inlet Pressure | 4–85 psig (0.3–5.8 bar) |
| Dimensions | 334 × 185 × 324 mm |
| Weight (with base) | 7.0 kg |
| Enclosure Material | UL 94 V-0 Flame-Retardant Polystyrene |
| Wetted Materials | 316 Stainless Steel, Quartz, PEEK, Titanium, PTFE, Silicone, FFKM, EPDM |
| Environmental Operating Range | 5–50 °C / 5–80% RH (non-condensing) |
| Power | 100–240 VAC, 50/60 Hz, max. 40 W |
| Certifications | CE, cULus |
| Traceability | NIST-traceable conductivity & temperature sensors per ASTM D1125 and D5391 |
| Compliance | ASTM D5173, USP <643>, EP 2.2.44, JP 2.59, ChP 0912 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | 770MAX |
| Input Channels | 6 (up to 16 measured parameters) |
| Sensor Types Supported | 8 (e.g., conductivity/resistivity, pH/ORP, dissolved oxygen, ozone, TOC, flow, temperature, pressure, level) |
| Output Options | 4 or 8 × 0/4–20 mA analog outputs |
| Communication | RS232 serial interface |
| Relay Outputs | 4 (optional) |
| Display | Multi-line scrolling LCD with customizable parameter naming |
| Power Supply | Universal 100–240 VAC, 50–60 Hz |
| Enclosure | 1/4 DIN, IP65-rated with sealed rear cover |
| Calibration Support | NIST-traceable verification via optional 1875 Smart Calibrator |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HDS-100G / HDS-100GN |
| Instrument Type | Radiation Survey Meter & Nuclide Identifier |
| Detector | CsI(Tl) scintillator (γ), LiI(Eu) scintillator (neutron, GN version) |
| γ Energy Range | 30 keV – 3 MeV |
| Neutron Energy Range | 0.025 eV – 15 MeV |
| γ Dose Rate Range | 0.01 µSv/h – 10 mSv/h |
| Operating Modes | Search, Detection, Spectrum Acquisition |
| Alarm | Independent γ and neutron visual/audible alerts |
| Data Logging | >1,000 event-stamped records |
| Standards Compliance | ANSI N42.33-2021, IEC 62401:2022, IAEA TECDOC-1369 |
| Power | 6 × AA alkaline or Ni-MH rechargeable batteries |
| Battery Life | >24 h continuous operation |
| Dimensions | Ø78 mm × 280 mm |
| Weight | 1.5 kg (with batteries) |
| Operating Temperature | −20 °C to +50 °C |
| Environmental Rating | IP65 |
| EMI/EMC | MIL-STD-461G compliant |
| Mechanical Robustness | Drop-tested per IEC 60068-2-32 (1.2 m onto concrete) |
| Certifications | CE Marked (2014/30/EU, 2014/53/EU, 2011/65/EU) |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | MIC-500S-MEK |
| Output Options | 4–20 mA (3-wire or 4-wire), 0–5/0–10 V, RS485 (Modbus RTU), Dual Relay Outputs |
| Communication | Wired, LAN, Internet, Wireless (433 MHz, GPRS, Wi-Fi, Custom RF) |
| Remote Operation | Infrared remote control (15 m range, intrinsically safe operation without opening enclosure) |
| Calibration | Auto-zero tracking, multi-point calibration support |
| Certifications | CPA Type Approval (China), Ex d IIC T6 Gb explosion-proof certification, EMC/EMI compliant (GB/T 18268, GB/T 17626 series), Anti-static & reverse-polarity protected |
| Sensor Options | Electrochemical, Catalytic Bead, NDIR, PID, Thermal Conductivity (selectable from Honeywell, Figaro, City Technology, Alphasense, Dynament, Membrapor) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ALTUM |
| Pricing | Upon Request |
| Brand | Micasense |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | Altum-PT |
| Price Range | USD 13,500 – 27,000 (est. based on ¥100,000–200,000 at 7.4 CNY/USD) |
| Weight | 460 g (camera + DLS2) |
| Dimensions | 11 × 8 × 6.9 cm |
| Power Input | 7–25.2 V DC |
| RGB Sensor | 12.4 MP global shutter, pixel-aligned with multispectral bands |
| Thermal Band | LWIR, 7.5–13.5 µm |
| GSD @ 120 m AGL | 5.28 cm (multispectral), 33.5 cm (thermal), 2.49 cm (panchromatic RGB) |
| Capture Rate | 2 Hz |
| Interfaces | 3 configurable GPIO (trigger in/out, PPS in/out, frame sync) |
| FOV | 50° H × 38° V (multispectral), 46° H × 35° V (panchromatic), 48° × 39° (thermal) |
| Storage | CFexpress Type B card |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RedEdge-MX + RedEdge-MX Blue 10-Channel System |
| Pricing | Upon Request |
| Weight | 508.8 g (including both sensors, dual-sensor mounting plate, DLS2, and cables) |
| Dimensions | 8.7 cm × 12.3 cm × 7.6 cm |
| Power Supply | 4.2–18.8 V DC |
| Spectral Bands | Coastal Blue (444 nm, 28 nm FWHM), Green (531 nm, 14 nm), Red (650 nm, 16 nm), Red Edge (705 nm, 10 nm), Red Edge (740 nm, 18 nm), Blue (475 nm, 32 nm), Green (560 nm, 27 nm), Red (668 nm, 14 nm), Red Edge (717 nm, 12 nm), NIR (842 nm, 57 nm) |
| RGB Output | 3.6 MP (global shutter, pixel-aligned across all bands) |
| Spatial Resolution | 1280 × 960 per band (1.2 MP per channel) |
| Ground Sampling Distance (GSD) | 8 cm/pixel at 120 m AGL |
| Capture Rate | 1 image/sec (full 10-band capture) |
| Interfaces | UART, 10/100/1000 Ethernet, removable Wi-Fi module, external trigger input, integrated GPS, SDHC card slot |
| Field of View | 47.2° diagonal |
| Trigger Modes | Timed, overlap-based, external TTL, manual |
| Operating Temperature | 0–40°C (no airflow) |
| Brand | MicaSense |
|---|---|
| Origin | USA |
| Manufacturer | MicaSense, Inc. |
| Model | RedEdge-MX |
| Spectral Bands | Blue (475 nm, 20 nm FWHM), Green (560 nm, 20 nm FWHM), Red (668 nm, 10 nm FWHM), Red Edge (717 nm, 10 nm FWHM), Near-Infrared (840 nm, 40 nm FWHM) |
| Weight | 170 g (incl. DLS) |
| Dimensions | 9.4 × 6.3 × 4.6 cm |
| Operating Voltage | 4.2–15.8 V DC |
| Power Consumption | 4 W (typ.), 8 W (max.) |
| Ground Sampling Distance (GSD) | 8.2 cm/pixel at 120 m AGL |
| Capture Rate | 1 frame/sec |
| Output Format | 12-bit RAW per band + geotagged JPEG |
| Interface Options | Wi-Fi, Ethernet, UART |
| Environmental Rating | No moving parts |
| Calibration | Factory radiometric and geometric calibration |
| Software Ecosystem | Atlas cloud platform + desktop tools (AgPixel, Pix4D, QGIS, ENVI plugins) |
| Brand | Micasense |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | RedEdge-P Blue/Green Dual Multispectral Camera System |
| Price Range | USD 17,500 – 21,700 (based on exchange rate and landed cost) |
| Spectral Bands | 10 total (5 per camera) |
| Panchromatic Resolution | 5.1 MP (2464 × 2056) |
| Multispectral Resolution | 1.6 MP per band (1456 × 1088) |
| GSD @ 120 m | 3.98 cm (panchromatic), 7.7 cm (multispectral) |
| FOV | 50° H × 38° V (MS), 44° H × 38° V (PAN) |
| Frame Rate | 3 fps |
| Calibration | Factory radiometric calibration + DLS2 downwelling irradiance sensor + CRP2 reflectance panel support |
| Interfaces | Gigabit Ethernet, USB 2.0 (Wi-Fi module), RS-232 serial, 3 configurable GPIO (trigger in, PPS in/out, pulse out) |
| Mounting | SkyPort-compatible for DJI enterprise drones |
| Brand | MicaSense |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | RedEdge-P |
| Price Range | USD 6,800 – 13,600 (est. based on ¥50,000–100,000 at 7.35 CNY/USD) |
| Weight | 350 g (incl. DLS2) |
| Dimensions | 8.9 × 7.0 × 6.7 cm |
| Input Voltage | 7–25.2 V DC |
| Power Consumption | 5.5 W (standby), 7.0 W (average), 10 W (peak) |
| Spectral Bands | Blue (475 nm), Green (560 nm), Red (668 nm), Red Edge (717 nm), Near-Infrared (842 nm) |
| RGB Output | 5.1 MP global shutter, radiometrically aligned with multispectral bands |
| Multispectral Sensor Resolution | 1.6 MP per band |
| Panchromatic Resolution | 5.1 MP |
| Spatial Resolution | 7.7 cm/pixel @ 120 m (multispectral), 3.98 cm/pixel @ 120 m (panchromatic) |
| Frame Rate | 3 Hz (RAW DNG) |
| Storage | CF card |
| FOV | 50° H × 38° V (multispectral), 44° H × 38° V (panchromatic) |
| Interfaces | 3× GPIO (trigger in, top-of-frame out, 1 PPS out), push-button control, UART serial, USB 2.0 (for Wi-Fi module), 10/100/1000 Ethernet, CF card slot |
| Brand | Micro Emission |
|---|---|
| Origin | Japan |
| Model | MH-5000 |
| Instrument Type | Portable |
| Detection Principle | Liquid Electrode Capillary Plasma Optical Emission Spectrometry (LECP-OES) |
| Target Analytes | Multi-element (≥40 metals, including As, Cd, Cr, Cu, Fe, Pb, Mn, Ni, Zn, etc.) |
| Analysis Time | ≤5 s per sample |
| Sample Volume | 40 µL |
| Power Supply | 6 × AA batteries or AC adapter |
| Weight | 1.4 kg (including battery) |
| Dimensions | 20 × 10 × 11 cm |
| Gas Requirement | None |
| Cooling | Air-cooled, no water circulation |
| Exhaust | No dedicated fume hood required |
| Compliance | Designed for field-deployable environmental testing in accordance with EPA Method 200.7–derived protocols and ISO 17294-2:2016 principles |
| Brand | Micro Emission |
|---|---|
| Origin | Japan |
| Model | MH-6000A |
| Instrument Type | Portable |
| Detection Principle | Optical Emission Spectrometry (OES) with Liquid Electrode Capillary Plasma (LECP) Excitation |
| Target Analytes | Multi-element (≥40 metals, including As, Cd, Cr, Cu, Fe, Pb, Zn, Ni, Mn, Al, Si, etc.) |
| Analysis Time | ≤5 s per sample |
| Detection Limit | Sub-ppm to ppm range |
| Power Requirement | 100 W AC/DC |
| Weight | 4.4 kg |
| Dimensions | 31 × 16 × 20 cm |
| Gas-Free Operation | Yes |
| Cooling System | None required |
| Exhaust Ventilation | Not required |
| Sample Introduction | Peristaltic pump |
| Detector Configuration | Dual-detector array (UV–Vis–NIR extended range) |
| Optional Accessory | Sapphire flow cell (for alkaline and high-silica matrices) |
| Brand | Micro-Hybrid |
|---|---|
| Origin | Germany |
| Model | INC5701D-360-SA-U/I |
| Measuring Range | 1°–360° |
| Supply Voltage | 5–32 V DC |
| Angular Accuracy (Digital Interface) | < 0.04° |
| Angular Accuracy (Analog Interface) | < 0.12° |
| Digital Interfaces | RS485, Ethernet, PROFINET, EtherNet/IP |
| Analog Outputs | 4–20 mA (max. 390 Ω), 0.5–4.5 V (min. 1 kΩ, configurable) |
| Operating Temperature | −40 °C to +85 °C |
| Housing Material | Die-cast Aluminum |
| Weight | ~250 g |
| Embedded Signal Processing | SensorFUSION Algorithm |
| Brand | Micro-Hybrid |
|---|---|
| Origin | Germany |
| Model | ACC5703 |
| Axes | 3 |
| Measuring Range | ±0.1 g to ±8 g (configurable) |
| Resolution (Digital) | ≤0.016 mg |
| Resolution (Analog Current) | ≤0.24 mg |
| Resolution (Analog Voltage) | ≤0.31 mg |
| Noise Density | 30 µg/√Hz (typ.) |
| Sensitivity (Current Output) | ≤80 mA/g |
| Sensitivity (Voltage Output) | ≤20 V/g |
| Zero Output | 12 mA or 2.5 V |
| Linearity | 0.45 % FSO (typ.) |
| Frequency Range | 0–1000 Hz (configurable) |
| Sampling Rate | Up to 4 kHz |
| Cross-Axis Sensitivity | 1 % FSO |
| Temperature Stability | ±0.2 mg/K (typ.) |
| Supply Voltage | 5–32 VDC |
| Power Consumption | <3 W |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +85 °C |
| Digital Interface | RS485 |
| Analog Outputs | 4–20 mA (max. 390 Ω) and 0.5–4.5 V (min. 1 kΩ), configurable |
| Switching Output | 0/5 V (min. 1 kΩ) |
| Protection Rating | IP67 (when connected) |
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | ALGcontrol |
| Measurement Parameters | Chlorophyll a (Chl-a), Dissolved Organic Matter (DOM), Turbidity |
| Wavelengths | 365, 450, 525, 570, 590, 615, 710 nm |
| Chl-a Range | 0–200 µg/L |
| Chl-a Resolution | 0.2 µg/L |
| Turbidity Range | 0–400 NTU |
| Detector | DTGS with 24-bit ADC sampling |
| Interface | LAN, CAN-Bus, RS232, RS485, Modbus TCP/RTU |
| Analog Outputs | 2 × 4–20 mA |
| Power Supply | 24 VDC |
| Power Consumption | 45 W |
| Enclosure Material | Aluminum |
| IP Rating | IP54 (optional IP65) |
| Dimensions (H×W×D) | 450 × 450 × 260 mm |
| Operating Sample Temp. | 10–35 °C |
| Ambient Temp. | 15–30 °C |
| Sample Flow Rate | 2–10 L/h |
| Cleaning System | Automated NaOCl-based (≤0.05% active chlorine) |
| OS | Embedded Linux |
| Software | SQL-based PC software with audit-ready data logging |
| Brand | microLAN |
|---|---|
| Country of Origin | Netherlands |
| Model | BACTcontrol |
| Measurement Principle | Enzymatic Fluorescence Assay |
| Target Analytes | β-Galactosidase (coliforms), β-Glucuronidase (E. coli), Alkaline Phosphatase (total viable biomass) |
| Measurement Cycle | 1–2 h |
| Detection Method | Substrate-specific fluorogenic enzymatic reaction |
| Sample Flow Rate | 3 L/h |
| Sample Temperature Range | 10–35 °C |
| Ambient Operating Temperature | 15–30 °C |
| Power Supply | 220 V / 50 Hz or 110 V / 60 Hz |
| Power Consumption | <100 W |
| Enclosure Rating | IP54 (optional IP65) |
| Dimensions (H×W×D) | 460 × 450 × 321 mm |
| Weight | 25 kg |
| Housing Material | Aluminum |
| Max. Sample Pressure | 0.05 bar |
| Interface | 2× USB 2.0 (Type A), 2× Gigabit Ethernet (RJ45), Modbus TCP/RTU, 2× digital inputs, 2× relay outputs, 1× 4–20 mA analog output |
| Optional | UMTS/ISDN modem slot, dual-sample inlet with auxiliary cleaning module, climate control unit (>30 °C ambient), automated NaOCl-based cleaning system (≤0.05% active chlorine) |
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | iTOXcontrol |
| Instrument Type | Online |
| Biological Indicator | *Aliivibrio fischeri* (formerly *Vibrio fischeri*) |
| Operating Temperature | 5–40 °C |
| Reagent Temperature Range | 15–30 °C |
| Repeatability | Relative Error ≤5% |
| Sample Throughput | 10 mL/h (4.5 mL per test, 2 tests/h) |
| Measurement Duration | 40 min |
| Enclosure Rating | IP31 |
| Power Supply | 220 VAC, 50 Hz or 110 VAC, 60 Hz |
| Dimensions (D×W×H) | 50×50×110 cm (plus 73 cm with trolley) |
| Weight | 90 kg (excl. optional air conditioning unit: +20 kg) |
| Brand | microLAN |
|---|---|
| Origin | Netherlands |
| Model | TOX mini |
| Instrument Type | Portable |
| Biological Indicator | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature | 15–30 °C |
| Reagent Storage & Use Temperature | 15–30 °C |
| Detection Principle | Bioluminescence Inhibition Assay |
| Compliance | EN ISO 11348-3 |
| Detector | Ultrafast Single-Photon Counting Photomultiplier Tube (PMT) |
| Wavelength Range | 380–630 nm |
| Data Storage Capacity | 2000 measurements |
| Power Supply | Rechargeable 3×Ni-Cd battery or external AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170×150×280 mm |
| Weight | 2.0 kg (with battery) |
| Sample Vessel | Standard 15 mm diameter × 47–75 mm height test tubes |
| Humidity Range | 10–90 % RH (non-condensing) |
| Onboard Templates | 6 preconfigured toxicity test protocols |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TOXmini |
| Instrument Type | Portable |
| Biological Indicator | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature Range | +15 °C to +30 °C |
| Reagent Storage & Handling Temperature | +2 °C to +8 °C |
| Repeatability | ≤15% RSD (Relative Standard Deviation) at 50% inhibition level |
| Batch Capacity | 1–12 samples per run |