Environmental Monitoring Instruments
Filter
Showing 5731–5760 of 9112 results
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Endotoxin Detection System |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microfluidic Sensor Chip |
| Sensitivity | 0.00742 EU/mL |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed to support USP <85>, EP 2.6.14, and ISO 11737-1 workflows |
| Sample Format | Aqueous liquid samples only |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Interface | USB-C & Bluetooth 5.0 |
| Software Platform | MIPS EndoTrack™ v3.2 (Windows/macOS compatible) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Pesticide Detection System |
| Instrument Type | Multi-Ion Analyzer |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microsensor Chips |
| Sample Matrix | Aqueous Solutions |
| Configurations | Single-, Dual-, or Multi-Channel Options Available |
| Integrated Components | Micro-peristaltic Pumps, Multi-Functional Microfluidic Analysis Chamber, Embedded Signal Processing Unit |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA PICO ETO |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIRA PICO MOBILE LDS |
| Pricing | Available Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MIRO |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MGA-5 |
| Pricing | Upon Request |
| Measurement Principle | Time-Multiplexed Intermittent Continuous-Wave Quantum Cascade Laser Absorption Spectroscopy (TM-ICW-QCL) |
| Sampling Frequency | 1 Hz |
| Detection Limits (1 s) | CO: 0.4 ppb, CO₂: 0.8 ppm, CH₄: 1 ppb, N₂O: 0.5 ppb, H₂O: 40 ppm |
| Detection Limits (200 s) | CO: 0.07 ppb, CO₂: 0.08 ppm, CH₄: 0.2 ppb, N₂O: 0.1 ppb, H₂O: 6 ppm |
| Measurement Ranges | CO: 0–20 ppm, CO₂: 0–8000 ppm, CH₄: 0–200 ppm, N₂O: 0–20 ppm, H₂O: 0–10 %v/v |
| Maximum Drift (12 h) | CO: 1 ppb, CO₂: 1 ppm, CH₄: 5 ppb, N₂O: 2 ppb, H₂O: 120 ppm |
| Operating Temperature | –10 to +45 °C |
| Relative Humidity | < 90 % RH (non-condensing) |
| Pressure Range | 700–1050 mbar |
| Sample Flow Rate | 0.5–1.5 L/min (high-flow option available) |
| Power Supply | 220 VAC, 50 Hz, < 450 W |
| Dimensions (Analyzer) | 48 W × 18 H × 62 D cm |
| Weight (Analyzer) | 20 kg |
| (Cooling Unit) | 11 kg |
| (Vacuum Pump) | 9 kg |
| Safety Certifications | CE-marked per IEC 61010-1:2010, IEC 61326-1:2012, IEC 60825:2019 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ML-60 |
| Pricing | Available Upon Request |
| Humidity Range | 0–10 %vol |
| Humidity Accuracy | ±1 %vol |
| Temperature Range | −80 to +350 °C |
| Temperature Accuracy | ±0.2 °C |
| Display | LED LCD showing %vol H₂O, ppmv H₂O, RH%, and temperature |
| Sampling Method | Insertion-type probe |
| Sample Pressure | 0.2–10 bar (adjustable) |
| Sample Flow Rate | 1–3 L/min |
| Sample Line Material | Electropolished 316L Stainless Steel |
| Sensor Mount Thread | 0.750-16 UNF-2A |
| Optical Cell Connection | Swagelok® 6 mm or 1/4″ compression fitting |
| Operating Temperature | −20 to +60 °C (electronics), −60 to +250 °C (probe) |
| Storage Temperature | −10 to +50 °C |
| Ambient Humidity | ≤90 %RH, non-condensing |
| Optical Interface | FC/APC fiber connector |
| Communication | RS-485 (Modbus RTU) |
| Analog Output | 4–20 mA (isolated, configurable per parameter) |
| Power Supply | DC 24 V ±10 % or AC 220 V ±15 %, 50/60 Hz |
| Power Consumption | ~4 W |
| Key | Origin: Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | ML-3100 |
| Operating Principle | Laser Backscatter Light Scattering |
| Explosion-Proof Rating | Ex d IIB T4 Gb |
| Measurement Range | 0–200 mg/m³ (low range) / 0–10 g/m³ (high range) |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of reading |
| Relative Error | ±2% FS |
| Operating Temperature | −40 °C to +65 °C |
| Humidity Range | 0–100% RH |
| Max Flue Gas Temp | 300 °C (customizable for higher) |
| Output Signal | 4–20 mA (max load 500 Ω) |
| Power Consumption | ≤3 W |
| Dimensions | 160 × 160 × 250 mm |
| Weight | 4 kg |
| Applicable Stack Diameter | 0.5–15 m |
| Minimum Detectable Concentration | 2 mg/m³ |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ML3600 |
| Price | USD 3,950 (FOB) |
| Measurement Principle | Laser Backscatter Photometry |
| Explosion-Proof Rating | Ex d IIB T4 Gb |
| Measurement Range | 0.01–200 mg/m³ and 0–10 g/m³ (dual-range selectable) |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of full scale |
| Relative Error | < ±2% |
| Operating Temperature | −40 °C to +65 °C |
| Humidity Range | 0–100% RH (non-condensing) |
| Max. Flue Gas Temp. | 300 °C (high-temp option available) |
| Output Signal | 4–20 mA (max. load 500 Ω) |
| Power Supply | DC 16–24 V ±10% |
| Power Consumption | ≤3 W |
| Dimensions | 160 × 160 × 250 mm |
| Weight | 4 kg |
| Flue Diameter Compatibility | ≥2000 mm (standard) |
| Sensitivity Threshold | 2 mg/m³ |
| Installation | Single-ended, tool-free mounting |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | MLSS-300 |
| Measurement Principle | Infrared Absorption (Nephelometric/Transmissometric Dual-Mode) |
| Display | High-Brightness Sunlight-Readable LCD |
| Temperature Compensation | Automatic (PT100 RTD input supported) |
| Enclosure Rating | IP66/IP68 (Outdoor-rated, Wall or Pipe Mountable) |
| Cleaning | Compressed Air Purge System (Optional Auto-Cycle Control) |
| Power Supply | 24 VDC ±15% |
| Output | 4–20 mA (HART optional), RS485 Modbus RTU |
| Data Retention | Non-volatile memory with >10-year backup (EEPROM) |
| Alarm Functions | Dual-setpoint high/low concentration alarms with relay outputs |
| Installation | In-situ (submersible or flow-through) or side-stream configuration |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 500D |
| Instrument Type | Laboratory & Field-Deployable Water Quality Analyzer |
| Detection Parameters | >100 parameters including heavy metals (e.g., Cr, Cd, Pb, Ni, Cu, Zn), nutrients (NO₃⁻, NO₂⁻, NH₄⁺, PO₄³⁻), organic indicators (COD, TOC, BOD surrogate), turbidity, chlorine species, pH (via optional electrode module), and colorimetric ions (Fe, Mn, Al, SiO₂) |
| Wavelength Range | 340–860 nm (10 fixed-band interference filters at 345/365/436/470/520/540/585/620/690/800 nm) |
| Wavelength Accuracy | ±2 nm |
| Spectral Bandwidth | 10–12 nm |
| Light Source | Tungsten halogen lamp |
| Detector | Silicon photodiode |
| Photometric Accuracy | ±1% FS |
| Drift Stability | <0.002 Abs/h |
| Sample Holders | 16-mm round cuvettes (NANOCOLOR® certified), plus 10-mm, 20-mm, and 50-mm rectangular cuvettes |
| Data Storage | 500 measurement records with GLP-compliant metadata (date/time, operator ID, method ID, calibration status) |
| Display | Graphic LCD (64 × 128 pixels), backlight, 10-language UI (English, German, French, Spanish, Italian, Portuguese, Dutch, Polish, Czech, Turkish) |
| Connectivity | USB 1.1 + bidirectional RS-232 |
| Power | AC 100–240 V, 50/60 Hz or internal rechargeable Li-ion battery (6 V, 3.2 Ah) |
| Dimensions | 227 × 282 × 105 mm |
| Weight | 2.4 kg |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 91913 |
| Price | Upon Request |
| Display | 2-line LED, 6 mm character height |
| Voltage | 110–230 V~, 50/60 Hz |
| Power Consumption | 125 / 250 VA |
| Dimensions (W × D × H) | 150 × 250 × 140 mm |
| Sample Capacity | 12 positions |
| Predefined Temperatures | 70 / 100 / 120 / 148 / 160 °C |
| Predefined Timings | 1 / 2 h (at lower T), 1 / 2 h (at higher T) |
| User-Defined Temperature Range | 30–160 °C (1 °C increment) |
| User-Defined Time Range | 00:01–66:59 h (1 second increment) |
| Compliance | EN 61326-1:2013 (EMC), Directive 2014/30/EU (EMC), GLP-supporting firmware and interface logging |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioFix Lumi-10 |
| Instrument Type | Portable |
| Biological Agent | Bioluminescent Bacteria (Aliivibrio fischeri) |
| Operating Temperature Range | 0°C to 40°C |
| Reagent Storage & Usage Temperature | 0°C to 40°C |
| Coefficient of Variation (CV) | <10% |
| Photon Detection Rate | 5,000 photons per 0.1 second |
| Default Measurement Duration | 10 seconds (adjustable from 0.5 to 20 seconds) |
| Detector | Fast Single-Photon-Counting Photomultiplier Tube (PMT) |
| Spectral Sensitivity Range | 380–630 nm |
| Display | LED monochrome, 128 × 64 pixels |
| Data Storage Capacity | 2,000 measurement records |
| Relative Humidity Tolerance | 10–90% RH (non-condensing) |
| Recommended Operational Ambient Temperature | 15–30°C |
| Power Supply | 3× rechargeable Ni-Cd batteries or AC adapter (230 V/50 Hz or 115 V/60 Hz) |
| Dimensions (H×W×D) | 170 × 150 × 280 mm |
| Weight | 2.0 kg (including batteries) |
| Compliance | EU Low-Voltage Directive 73/23/EEC, EMC Directive 89/336/EEC (as amended by 92/31/EEC) |
| Brand | Macherey-Nagel (Germany) |
|---|---|
| Origin | Germany |
| Model | PF-3 919342 |
| Instrument Type | Portable |
| Measurement Principle | UV Absorption Spectrophotometry |
| Wavelength | 365 nm |
| Measurement Range | 2–60,000 mg/L COD |
| Repeatability | High precision |
| Detection Limit | Low (optimized for high-sensitivity UV absorption) |
| Measurement Time | <5 seconds per sample |
| Sample Throughput | Single-sample mode |
| Optical System | LED-based photometer with interference filters (365/450/595 nm) |
| Wavelength Accuracy | ±2 nm |
| Bandwidth (FWHM) | 10–12 nm |
| Detector | Silicon photodiode |
| Cuvette Format | 16 mm round tubes |
| Data Storage | 50 measurement records |
| Display | Graphical LCD (64 × 128 pixels) |
| Operating Temperature | 10–40 °C |
| Relative Humidity | ≤80% RH (non-condensing) |
| Power Supply | 3×AA batteries (alkaline or rechargeable), USB bus power, optional internal rechargeable battery |
| Enclosure Rating | IP68 |
| Dimensions | 170 × 95 × 68 mm |
| Weight | 0.5 kg |
| Compliance | CE-marked |
| Warranty | 12 months |
| Brand | MN |
|---|---|
| Origin | Germany |
| Model | 904 Series |
| Format | Individual strips, 200 per box |
| Dimensions | 11 × 100 mm |
| pH Range Options | 0–1.8 to 12–14.0 |
| Increment Resolution | 0.2–0.5 pH units (model-dependent) |
| Application-Specific Calibration | Optimized for colored aqueous samples |
| Brand | MN |
|---|---|
| Origin | Germany |
| Model | PF-12 |
| Instrument Type | Laboratory & Field-Portable Photometer |
| Detection Parameters | Heavy Metals (e.g., Cr, Cu, Pb, Cd, Ni), COD, Ammonia, Nitrate, Nitrite, Total Phosphorus, Total Nitrogen, Chlorine, pH (via compatible test kits), Turbidity (via VISOCOLOR ECO/NANOCOLOR methods) |
| Wavelength Range | 345 / 436 / 470 / 540 / 585 / 620 / 690 nm (±2 nm accuracy) |
| Optical System | Microprocessor-Controlled Single-Beam Filter Photometer with 7-Position Filter Wheel |
| Light Source | Tungsten Halogen Lamp |
| Detector | Silicon Photodiode |
| Photometric Range | ±3 Absorbance Units (E) |
| Accuracy | ±1% of reading |
| Stability | <0.002 E/h |
| Sample Format | 16 mm Round Cuvettes |
| Data Storage | 200 GLP-Compliant Records (including sample ID, location, dilution factor, date/time, operator ID) |
| Display | Backlit LCD (64 × 128 pixels) |
| Interface | USB 2.0 (data transfer, firmware update, power supply) |
| Power Options | USB bus power, 4× AA alkaline/rechargeable batteries (≥2000 measurements per charge), 12 V automotive adapter (REF 919 220), optional charger (REF 919 221) |
| Environmental Rating | IP67 |
| Operating Temp. | 0–50 °C |
| Dimensions | 215 × 100 × 65 mm |
| Weight | 0.7 kg |
| Compliance | EN 61010-1 (2010), 2006/95/EC (Low Voltage Directive), 2004/108/EC (EMC Directive), ISO 9001 certified manufacturing |
| Warranty | 2 years |
| Brand | MN |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PF-12 |
| Instrument Type | Portable / Handheld Photometer |
| Detection Targets | Heavy Metals (e.g., Cr, Cu, Ni, Pb, Zn, Cd, Fe, Mn) and Organic Parameters (e.g., COD, NO₃⁻, NO₂⁻, NH₄⁺, PO₄³⁻, Cl₂, TOC proxies) |
| Wavelength Range | 340–860 nm (7 fixed filters: 345, 436, 470, 540, 585, 620, 690 nm + 1 open slot) |
| Wavelength Accuracy | ±2 nm |
| Bandwidth | 10–12 nm |
| Light Source | Tungsten Halogen Lamp |
| Detector | Silicon Photodiode |
| Photometric Range | ±3 E (Absorbance) |
| Photometric Accuracy | ±1% of reading |
| Long-term Stability | <0.002 E/h |
| Sample Cell | 16 mm round cuvettes |
| Data Storage | 200 GLP-compliant records with timestamp, sample ID, location, dilution factor |
| Display | Backlit LCD (64 × 128 px) |
| Interface | USB 2.0 |
| Power Supply | USB bus power, AA alkaline or rechargeable batteries (≥2000 measurements per charge), 12 V automotive adapter |
| Enclosure Rating | IP67 |
| Dimensions | 215 × 100 × 65 mm |
| Weight | 0.7 kg |
| Operating Environment | 0–50 °C, ≤90% RH non-condensing |
| Compliance | EN 61010-1 (2006/95/EC Low Voltage Directive), EN 61326-1 (2004/108/EC EMC Directive), ISO 9001 certified manufacturing |
| Warranty | 2 years |
| Brand | MN |
|---|---|
| Origin | Germany |
| Model | 921 Series |
| Format | 100 strips/box, 6 × 85 mm |
| pH Range Options | 0.0–14.0 (multiple calibrated ranges) |
| Increment | 0.2–1.0 pH units (range-dependent) |
| Strip Construction | Chemically immobilized indicator dyes on cellulose fiber matrix |
| Compliance | Designed for ISO 9001-manufactured quality control |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MCY600 |
| Operating Temperature | 5–45 °C |
| Sample Gas Pressure | up to 20 kPa (gauge) |
| Sample Flow Rate | 0.2–1.0 L/min |
| Power Supply | 12–24 VDC |
| Output Signal | 4–20 mA |
| Communication Interface | RS485 (Modbus RTU) |
| Measurement Ranges | 0–5%, 0–10%, 0–21%, 0–50%, 0–90%, 90–100%, 0–100% O₂ (v/v) |
| Linearity Error | ±2% FS |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Cross-Interference Resistance | NH₃, CO, CO₂, CH₄ |
| Corrosive Gas Tolerance | Yes (e.g., H₂S) |
| Sensor Type | Thermal-Magnetic Paramagnetic Detection |
| Vibration Immunity | High |
| Consumable-Free Design | Yes |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MDL100 |
| Dilution Ratio Range | 10–1000× |
| Output Flow Rate | 0.5–5 L/min |
| Dilution Modes | Binary and Multi-component |
| Flow Control Principle | Thermal Mass Flow Control |
| Flow Accuracy | ±0.5% of reading |
| Repeatability | <0.2% RSD |
| Linearity (R²) | >0.9999 |
| Overall Dilution Uncertainty | <1% |
| Control Interface | Integrated Touchscreen PC with Customizable Software |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MDL200 |
| Dilution Ratio Range | 2–100× |
| Output Flow Rate | 1–5 L/min |
| Dilution Mode | Binary (Two-Gas) |
| Flow Control Technology | Thermal Mass Flow Control |
| Flow Accuracy | ±0.5% of reading |
| Repeatability | <0.2% RSD |
| Linearity (R²) | >0.9999 |
| Overall Dilution Uncertainty | <1% |
| Compliance | ISO 6145 |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MDL900 |
| Dilution Range | 100–10,000× (extendable to 10⁵×) |
| Output Flow Rate | 0.5–5 L/min |
| Flow Accuracy | ≤ ±0.5% of reading |
| Flow Repeatability | < ±0.2% RSD |
| Linearity (R²) | > 0.9999 |
| Dilution Accuracy | < ±2% |
| Maximum Back Pressure | 0.5 MPa |
| Compliance | ISO 6145 |
| Calibration Traceability | NIM (National Institute of Metrology, China) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MF610 |
| Temperature Range | 25–100 °C (±0.1 °C stability) |
| Permeation Chamber Dimensions | Φ24 mm × 130 mm |
| Mass Flow Range | 0–10 L/min (configurable with optional 1 L/min or 20 L/min modules) |
| Dilution Ratio | 6:1 to 96:1 (standard configuration) |
| Power Supply | AC 220 V, 200 W |
| Dimensions (L×W×H) | 490 × 402 × 155 mm |
| Weight | 18 kg |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MQ701-16 / MQ701-32 Integrated Solution |
| Pricing | Available Upon Request |
| Core Components | MQ801 Vacuum Sampling Chamber, MQ701-16/MQ701-32 16-/32-Position Automated Gas Bag Injector, MODEL401 Precision Gas Dilution System |
| Compliance | Designed to meet HJ 38–2017 (China EPA Standard for Determination of Total Hydrocarbons, Methane, and NMHC in Stationary Source Exhaust) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Model | MS900 |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Measurable Parameters | Moisture Content (ppm), Dew Point Temperature |
| Measurement Principle | Chilled Mirror Hygrometry (with high-stability imported sensor) |
| Dew Point Range | –100 °C to +20 °C (–80 °C to –10 °C calibrated |
| Accuracy | ±2 °C (–80 °C to –40 °C), ±5 °C (–40 °C to –10 °C) |
| Sample Flow Rate | 2–3 L/min (recommended: 2 L/min) |
| Response Time (t₉₀) | 10 s (–80 °C to –10 °C), 15 min (–100 °C to –80 °C) |
| Operating Pressure | 0–1 MPa |
| Ambient Operating Conditions | –30 °C to +70 °C, 0–100 % RH |
| Power Supply | DC 24 V (rechargeable Li-ion battery, >8 h runtime) |
| Internal Tubing | 1/8″ stainless steel |
| Fitting | 1/8″ Swagelok compression |
| Dimensions | 335 × 266 × 175 mm |
| Weight | ~3 kg |
| Recommended Calibration Interval | 24 months |
| Compliance | Designed for ISO 8573-3, ASTM D2013, and IEC 60076-15 (for insulating gas moisture monitoring) |
| Brand | MNK |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | MTB100, MQ701-6, MQ801 |
| Pressure Rating | 1800–5000 psi (DOT-certified) |
| Bag Volumes | 0.5 L, 1 L, 3 L, 5 L, 10 L |
| Bag Material | Polyvinyl Fluoride (PVF), 0.002" thickness |
| Valve Options | Polypropylene or Stainless Steel |
| Max Operating Temperature | 204°C |
| Bag Construction | 5-layer metallized foil (MNK123557) |
| Sample Compatibility | CO, CO₂, H₂S, NH₃, SO₂, NOₓ, and other low-molecular-weight gases |
| Detection Limit Suitability | ppb-level for inert and moderately reactive species |
| VOC Range Limitation | Not recommended for sub-ppm volatile organic compound quantification |
| Injector Configuration | 6/16/32-port programmable selection valve |
| Vacuum Source | Diaphragm pump (zero-contamination design) |
| Sample Line | Silinert®-passivated, heated (anti-condensation) |
| Controller | VICI high-reliability industrial controller |
| Power Supply | Rechargeable battery (MQ801) |
| Compliance | DOT 4BA/4BW certified (MTB100), GLP-compatible operation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HCS-501 |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | 203000 |
| Price | Upon Request |
| Operating Principle | Laser Backscatter |
| Safety Rating | Explosion-Proof |
| Measurement Range | 0–4000 mg/m³ (configurable) |
| Resolution | 0.01% of full scale |
| Accuracy | ±2% FS |
| Relative Error | <2% FS |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Model | Microtox® CTM |
| Instrument Type | Online Continuous Monitoring System |
| Biological Sensor | Aliivibrio fischeri (formerly Vibrio fischeri) |
| Operating Temperature | 5–30 °C |
| Photonic Detection Range | 1–120,000,000 photon counts per assay |
| Assay Duration | 5 minutes |
| Sample Flow Rate | 100–200 mL/min |
| Power Supply | 100–240 V AC, 50–60 Hz, 480 W |
| Display | 180 mm color touchscreen |
| Data Interfaces | Ethernet, USB, 4–20 mA output, relay alarm, optional GPRS/Wi-Fi |
| Certifications | CE, RoHS, WEEE |
| Enclosure Material | Anodized aluminum |
| Dimensions (Main Unit) | 1250 × 750 × 365 mm (H×W×D) |
| Weight | ~70 kg |
| Maintenance Interval | Monthly (~2 hours) |
| Reagent Format | Lyophilized, vacuum-sealed vials |
| Brand | Modern Water |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Microtox® FX Plus |
| Instrument Type | Portable |
| Biological Agent | *Vibrio fischeri* (NRRL B-11177) |
| Operating Temperature | 0°C – 40°C |
| Reagent Storage/Use Temperature | 10°C – 28°C |
| Repeatability | <20% CV |
| Photon Counting Range | 1 – 120 million counts |
| Assay Duration | 1 – 30 minutes (user-definable) |
| Compliance | ISO 11348-3, CE, ISO 13485 |