Environmental Monitoring Instruments
Filter
Showing 5641–5670 of 9112 results
| Brand | METER |
|---|---|
| Origin | Germany |
| Model | VARIOS |
| Instrument Type | Multifunctional Soil Analyzer |
| Measurement Principle | Transient Line Heat Source (TLHS) |
| Compliance | IEEE Std 442-2017, ASTM D5334, ISO 9001:2015, EM ISO/IEC 17050:2010 (CE) |
| Thermal Conductivity Range (TC-S70) | 1.3–10.3 W/m·K |
| Thermal Conductivity Range (TC-S100) | 0.8–6 W/m·K |
| Temperature Range (Storage/Drying) | −50 to 120 °C |
| Operating Temperature Range | −40 to 85 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Current Range | 20–200 mA |
| Heating Current Resolution | 10 µA |
| Heating Current Accuracy | ±0.05% |
| Linear Power Output Range | 0.5–20 W/m |
| Power Resolution | 20 mW/m |
| Power Accuracy | ±0.1% |
| Balance Capacity | 2200 g |
| Balance Readability | 0.01 g |
| Balance Repeatability & Linearity | 0.01 g |
| Probe Dimensions (TC-S70) | 114.0 × 19.4 × 13.25 mm |
| Probe Dimensions (TC-S100) | 144.0 × 19.4 × 13.25 mm |
| Balance Dimensions | 162 × 185 × 30 mm |
| Power Supply | 12 V / 1 A |
| Interface | USB |
| OS Compatibility | Windows 10 or later |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | WP4C |
| Instrument Type | Water Potential Meter |
| Measurement Principle | Dew Point Hygrometry |
| Range | 0 to –300 MPa |
| Accuracy | ±0.05 MPa (0 to –5 MPa), ±1% (–5 to –300 MPa) |
| Temperature Range | 15–40 °C |
| Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Measurement Time | 10–20 min (Precision Mode), <5 min (Rapid Mode) |
| Sample Chamber Volume | 7 mL (recommended), 15 mL (max) |
| Dimensions | 24.1 × 22.9 × 8.9 cm |
| Weight | 3.2 kg |
| Display | 20×2 LCD with backlight |
| Sensors | Chilled-mirror dew point sensor + infrared temperature sensor |
| Power | 110–220 V AC, 50/60 Hz |
| Interface | RS-232A (ASCII, 9600 baud, 8N1), USB adapter included |
| Compliance | ISO 9001:2015, CE (EN ISO/IEC 17050:2010), ASTM D6836-07 |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ZL6 Basic |
| Sensor Inputs | 6 × 3.5 mm stereo jacks (analog/digital/pulse) |
| Storage | 2 MB non-volatile flash memory (20,000–30,000+ records) |
| Sampling Interval | Configurable down to 1 min (default 60-min averaged/cumulative output) |
| Time Sync | Via ZENTRA Utility or ZENTRA Utility Mobile |
| Connectivity | USB-A to micro-B, Bluetooth 5.2 (BLE) |
| Power | 6 × AA alkaline batteries (3–12 months lifespan, depending on configuration) |
| Operating Temperature | −40 °C to +60 °C |
| Enclosure Rating | IP56 / NEMA 3R |
| Housing Material | UV-stabilized, impact-resistant polymer |
| Dimensions | 14.9 cm × 25.0 cm × 6.3 cm |
| Compliance | ISO 9001:2015, EM conformity per ISO/IEC 17050:2010 (CE Mark) |
| Data Security | SSL/TLS-encrypted cloud upload |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ZL6 |
| Instrument Type | Compact Wireless Weather Station |
| Power | Integrated Solar Panel + Rechargeable NiMH Battery |
| Data Connectivity | GSM (2G/3G) to Zentra Cloud |
| Local Storage Capacity | 40,000–80,000+ records |
| Sensor Interfaces | 6 universal analog/digital ports |
| IP Rating | IP67 enclosure |
| Operating Temperature Range | –25°C to 60°C |
| Compliance | FCC Part 15, CE, RoHS |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ZL6 Micro-Meteorological Monitoring System |
| Instrument Type | Portable Weather Station |
| Power | Integrated Solar Panel + NiMH Rechargeable Battery (3+ years life) or AA Alkaline Batteries (3–12 months) |
| Sensor Interfaces | 6 universal analog/digital ports |
| Expandable Sensors | 29 compatible sensor models |
| Data Storage Capacity | 40,000–80,000+ records (configurable) |
| Connectivity | Embedded GSM module (2G/3G fallback), ZENTRA Cloud integration |
| Enclosure | IP68-rated, UV-stabilized, radiation-shielded housing |
| Deployment | Plug-and-play sensor interface, no programming required |
| Compliance | Designed for GLP-aligned environmental field studies |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ZL6 Pro |
| Pricing | Available Upon Request |
| Brand | METER |
|---|---|
| Origin | USA |
| Model | ZL6 Soil Water Content and Water Potential Monitoring System |
| Instrument Type | Soil Moisture and Water Potential Analyzer |
| Channel Capacity | 6-channel data logger |
| Communication | GPRS-enabled, cloud-connected via Zentra Cloud |
| Power Supply | Solar-rechargeable NiMH battery |
| Enclosure Dimensions | 14.9 × 25 × 6.3 cm |
| Compliance | Designed for long-term field deployment in compliance with ISO 11274 (soil water retention), ASTM D5859 (in-situ soil moisture measurement), and GLP-aligned data traceability per FDA 21 CFR Part 11 requirements when configured with audit-trail-enabled Zentra Cloud subscription |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ZSC Bluetooth Sensor Adapter |
| Pricing | Contact for Quote |
| Brand | Mettler Toledo |
|---|---|
| Model | FG4 |
| Measurement Principle | Galvanic Cell (Self-Polarizing) |
| Temperature Compensation | Automatic (NTC 30 kΩ) |
| Atmospheric Pressure Compensation | Manual or Optional Barometric Sensor Input |
| Salinity Compensation | Manual Input (0–70 g/L) |
| Display | Backlit LCD with Electrode Status Indicator |
| Power Supply | 4 × AA Batteries (incl.) |
| IP Rating | IP67 |
| Operating Temperature | 0–50 °C |
| Storage Temperature | –25–70 °C |
| Compliance | CE, RoHS, ISO 5814 (Dissolved Oxygen — Electrochemical Probe Method) |
| Electrode Compatibility | LE611 (Standard), LE612 (Ruggedized) |
| Data Output | None (Standalone Unit) |
| Calibration | 1-point Air Saturation or 2-point (Air + Zero Solution) |
| Units | mg/L, % saturation, ppm, µmol/L |
| Resolution | 0.01 mg/L (DO), 0.1 °C (Temp) |
| Accuracy | ±0.2 mg/L (0–20 mg/L), ±0.5 °C (Temperature) |
| Brand | Met One Instruments (USA) |
|---|---|
| Origin | USA |
| Model | MetOne 804 |
| Instrument Type | Handheld |
| Flow Rate | 0.1 cfm (2.83 L/min) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±0 s |
| Repeatability | ±5% |
| Size Distribution Error | ±10% |
| Indication Error | ±10% |
| Particle Size Channels | 0.3, 0.5, 0.7, 1.0, 2.5, 5.0, 10.0 µm (user-selectable, 4 active simultaneously) |
| Concentration Limit | 1,000,000 particles/ft³ (105,900 particles/L) |
| Light Source | 780 nm laser diode, 30 mW |
| Power Supply | 7.2 V Li-ion rechargeable battery (30 h intermittent / 8 h continuous) |
| Dimensions | 9.5 × 17.2 × 5.1 cm (W × H × D) |
| Weight | 0.60 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Data Storage | 2,500 records |
| Display | 2-line × 16-character LCD |
| Interface | USB 2.0 |
| Compliance | ASTM F50, ISO 21501-4, ISO 14644-1, CE, JIS B 9921 |
| Brand | METONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Aerocet-531 |
| Price | Upon Request |
| Brand | METONE |
|---|---|
| Country of Origin | USA |
| Model | BAM-1020 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Measured Parameters | PM₂.₅, PM₁₀, TSP (with optional inlets) |
| Measurement Range | 0–1.000 mg/m³ |
| Sampling Flow Rate | 16.7 L/min (nominal, adjustable 0–20 L/min) |
| Detection Limit | 0.1 µg/m³ (1-hour average) |
| Measurement Interval | 1 hour |
| Flow Stability | ±2% over operating range |
| EPA Certification | U.S. EPA EQPM-0607-193 (PM₂.₅), EQPM-0607-194 (PM₁₀) |
| Operating Temperature | –30°C to +50°C |
| Relative Humidity Control | Integrated heated inlet with RH stabilization <40% |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | U.S. EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Fractions | PM₂.₅, PM₁₀, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Interval | Hourly |
| Data Storage Capacity | 182 days |
| RH Control | Integrated Heater with Precise Relative Humidity Management |
| Calibration | Automated Zero/Drift Checks per Cycle |
| Output Interface | RS-232 |
| Meteorological Integration | Up to 6 Sensors |
| Remote Operation Duration | Up to 60 Days Unattended |
| Compliance | EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited Ambient Monitoring Applications |
| Brand | Metone |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| EPA EQPM Certification | EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Cutoffs | PM₁₀, PM₂.₅, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Frequency | Hourly |
| Filter Tape | Rotating glass fiber tape (30-sample capacity) |
| RH Control | Integrated heater for dew point suppression |
| Data Storage | 182 days (internal) |
| Communication | RS-232 serial interface |
| Meteorological Inputs | Up to 6 sensors |
| Remote Operation | Unattended operation up to 60 days via web-based telemetry |
| Calibration | Automated zero/drift checks per cycle |
| Compliance | U.S. EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited field deployment records |
| Operating Environment | -30°C to +50°C ambient |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10, PM2.5 |
| EPA Certification | EQPM-0798-122 (PM10 FEM), EQPM-0308-170 (PM2.5 Class III FEM) |
| Compliance | CE, NRC, TÜV, CARB, ISO 9001 |
| Range | 0–1000 µg/m³ (configurable up to 10,000 µg/m³) |
| Detection Limit | <1.0 µg/m³ (24-hr), <4.8 µg/m³ (1-hr) |
| Flow Rate | 16.7 L/min (adjustable 0–20 L/min) |
| Filter | Glass fiber tape, 30 mm × 21 m per roll |
| Beta Source | ¹⁴C, 60 µCi ±15 µCi (t₁/₂ = 5730 yr) |
| Data Storage | 182 days of hourly records |
| Operating Temp | –30 °C to +60 °C |
| RH Control | Internal heater, 10–99% RH setpoint |
| Power | 100–230 VAC, 50/60 Hz, <0.4 kW |
| Dimensions | 31 cm (H) × 43 cm (W) × 40 cm (D) |
| Weight | 24.5 kg |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Range | 0–50 mg/m³ |
| Sampling Method | Isokinetic Impactor with Rotating Glass Impactor Plate (30-sample capacity) |
| Data Output | Real-time mass concentration (µg/m³ or mg/m³), automatic zero/drift correction, event logging |
| Compliance | US EPA EQPM, UK MCERTS, Korea K-EMAS, China HJ 653-2013 |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1022 |
| Measurement Principle | Beta Attenuation Method (BAM) |
| EPA Designation | EQPM-1013-209 (Class III Federal Equivalent Method for PM₂.₅) |
| Measurement Range | −15 to 10,000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| LOD (1-hr, 2σ) | <2.4 µg/m³ |
| LOD (24-hr, 2σ) | <0.5 µg/m³ |
| Sample Flow Rate | 16.7 L/min |
| Filter Media | Continuous glass fiber tape (30 mm × 21 m roll, ~2 months lifespan) |
| Beta Source | ¹⁴C (60 µCi ±15 µCi, t₁/₂ = 5730 yr) |
| Detector | Scintillation photomultiplier tube |
| Operating Temperature | −30 °C to +50 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Power Input | 100–230 VAC, 50/60 Hz |
| Power Consumption | 300 W (full system including inlet heater and pump) |
| Analog Outputs | Dual isolated channels (user-selectable 0–1/0–2.5/0–5 VDC or 0–20/2–20/4–20 mA) |
| Digital Interfaces | RS-232, USB, Ethernet (shared serial port) |
| Data Logger Capacity | 108,134 records (12.5 years @ 1 record/hr |
| Certifications | US-EPA EQPM-1013-209, NRC, ISO 9001, RoHS |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Upon Request |
| Brand | METONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Available Upon Request |
| Brand | Metone |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Upon Request |
| Brand | Metone |
|---|---|
| Origin | USA |
| Model | E-BAM1020 |
| Measurement Principle | Beta-ray attenuation (β-ray) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Measurement Range | 0–1.000 mg/m³ |
| Sampling Interval | 1 hour |
| Volumetric Flow Rate | 0–20 L/min |
| Detection Limit | <4.8 µg/m³ |
| Flow Stability | ±5% |
| EPA EQPM Certification | EQPM-0798-122 |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53, Subpart C) |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | Met Station One |
| Output Interfaces | RS-232, SDI-12 (customizable to RS-485/RS-422) |
| Wind Speed Range | 0–50 m/s |
| Wind Speed Resolution | 0.1 m/s |
| Wind Speed Accuracy | ±2% |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 1° |
| Wind Direction Accuracy | ±5° |
| Temperature Range | −50 to +50 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Relative Humidity Range | 0–100% RH |
| RH Resolution | 1% RH |
| RH Accuracy | ±4% RH |
| Atmospheric Pressure Range | 500–1100 mbar |
| Pressure Resolution | 0.1 mbar |
| Pressure Accuracy | ±2 mbar |
| Brand | EcoTech |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | METOS® |
| Pricing | Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 2035 |
| Pricing | Available Upon Request |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | As, Hg, Cu, Pb, Cd, Zn, Fe, Ni, Co, Mn, Bi, Sb, Tl, Cr, Se, Te |
| Analysis Time | <5 minutes per sample |
| Current Range Accuracy | ±0.025% |
| Potential Resolution | ±0.2 mV |
| Electrode Options | scTRACE Gold electrode or disposable screen-printed electrodes (SPE) |
| Power Supply | Rechargeable Li-ion battery |
| Compliance | Designed to meet WHO drinking water guideline requirements for heavy metals |
| Software | Integrated VA software with pre-validated ASTM/ISO-aligned methods |
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm AG (in collaboration with ECN & Applikon) |
| Model | MARGA 2S |
| Instrument Type | Online Continuous Monitor |
| Compliance | EPA ETV Verified |
| Software | MARGA Control Suite v5.x |
| Data Output | Real-time ion concentrations (µg/m³), hourly time resolution |
| Sample Streams | Simultaneous PM₂.₅, PM₁₀, gaseous HNO₃, HCl, NH₃, SO₂, HCOOH, CH₃COOH |
| Detection Principle | Wet-chemical absorption + Dual IC (Ion Chromatography) |
| Automation Level | Fully unattended operation up to 168 h |
| Remote Capability | Secure web-based monitoring, diagnostic access, and parameter control via TLS-encrypted interface |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MARS |
| Pricing | Upon Request |
| Brand | Metrohm |
|---|---|
| Model | PILS |
| Origin | Imported (Switzerland/USA) |
| Manufacturer | Metrohm AG (via Applikon BV) |
| Power Supply | 110–240 V, 50/60 Hz |
| Sampling Time | 15 min – 1 h |
| Aerosol Size Range | 0.01–10 µm |
| Liquid Collection Medium | Deionized Water |
| Compatibility | Ion Chromatography (IC), including Metrohm and third-party systems |
| Internal Standard Integration | Yes |
| Self-Cleaning Function | Yes |
| Flow Rate Limiting | 1 m³/h |
| Compliance | Designed for GLP/GMP-aligned environmental monitoring workflows |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Models | TitrIC System 1, TitrIC System 2, TitrIC System 3 |
| Pricing | Available upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | 6000TOCi |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis |
| Measurement Range | 0–2000 ppb C |
| Accuracy | ±3% |
| Resolution | 0.001 ppb C |
| Detection Limit | 0.025 ppb C |
| Repeatability | ≤3% |