| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Micromac 1000 |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principle | Colorimetric Flow Analysis (CFA) with Loop Flow Reactor (LFA) |
| Max Parameters per Cycle | 4 |
| Detection Limit | Sub-ppb to ppm range (method-dependent) |
| Sample Volume per Analysis | 20–30 mL |
| Reagent Consumption | < 500 µL per test |
| Dilution Ratio | Up to 1:100 (factory-calibrated) |
| Data Storage Capacity | 400 records (date, time, absorbance, concentration) |
| Output Signals | 4–20 mA (400 Ω load), 0–5 V, RS-232 (RS-485 optional) |
| Power Supply | 12 V DC |
| Power Consumption | 3 W (standby), 10 W (active) |
| Operating Temperature | 5–40 °C |
| IP Rating | IP55 (IP65 optional) |
| Dimensions (L×H×W) | 550 × 350 × 110 mm |
| Weight | 13 kg (excluding reagents) |
| Sample Temp. Range | 10–30 °C |
| Sample Turbidity/Color | No restriction (blank correction applied) |
| pH Range (method-dependent) | 3–12 |
| Reaction Cell Pathlength | 10–50 mm (50 mm for seawater) |
| Detector | Dual-beam silicon photodetector, multi-wavelength LED source |
| Flow System | Integrated peristaltic sampling pump + LFA reactor (10 mL volume) |
| Compliance | EPA, ISO, and DIN standard methods implemented |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MICROMAC 1000 |
| Pricing | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYSTEA Micromac C |
| Pricing | Upon Request |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China (Distributed) |
| Model | SYSTEA Micromac C |
| Measurement Principles | Colorimetric Spectrophotometry (UV-Vis) |
| Analytes | Nitrate-N, Nitrite-N, Ammonia-N, Orthophosphate, Silicate, Sulfate, Total Phosphorus, Total Nitrogen |
| Detection Method | Batch-type Flow-Through Cell with LED-based Photometric Detection |
| Operating Modes | Manual, Cyclic, Triggered, Continuous |
| Communication Interfaces | RS232, RS485, 4–20 mA analog output |
| Optional | Ethernet interface, Pre-treatment module, Dual-waste separation (toxic/non-toxic), Leak detection sensor, Reagent level monitoring |
| Compliance Support | Designed for continuous unattended operation in GLP-aligned environmental monitoring labs |
| Brand | SYSTEA |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Micromac C |
| Pricing | Available Upon Request |
| Brand | Micrometrix |
|---|---|
| Origin | USA |
| Model | SCM-1 |
| Measurement Range | −1000 to +1000 mV |
| Output | 4–20 mA, ±10 V, 0–10 V |
| Display | LED, millivolt resolution |
| Flow Rate | 1 L/min (standard), 5 GPM (optional) |
| Inlet/Outlet | 1/2″ barb inlet, 3/4″ barb outlet |
| Response Time | 1 second |
| Accuracy | ±0.1% of full scale |
| Enclosure | NEMA 4X, IP65 |
| Power | 230 VAC |
| Probe Materials | Delrin®, 316 stainless steel, PTFE |
| Sensor Serviceability | Replaceable piston, disposable PTFE sleeve, field-swappable electrodes |
| Communication | Modbus RTU (optional) |
| Alarm Outputs | Dual SPDT relays with adjustable setpoints |
| Zero & Sensitivity Adjustment | Front-panel accessible, continuous analog tuning |
| Diagnostic Indication | Flashing LED status indicator |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SCM-2 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NTH-310F |
| Price Range | USD 13,500 – 27,000 (FOB) |
| Frequency Range | 100 kHz – 6.5 GHz |
| Measurement Accuracy | ±3 dB (100 MHz – 3.3 GHz) |
| Electric Field Range | 0.01 – 9999 V/m |
| Magnetic Field Range | 0.0001 – 265.3 A/m |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | MicroStation AquaSense |
| Pricing | Available Upon Request |
| Brand | Huiyan |
|---|---|
| Model | MHJ-3 |
| Instrument Type | Microwave Power Density Meter |
| Frequency Range | 0.9–3 GHz |
| Antenna Gain | >2 dBi |
| Measurement Range | 0.2 µW/cm² to 20 mW/cm² |
| Dimensions | 118 mm × 60 mm × 39 mm |
| Weight | <80 g |
| Power Supply | Passive (RF-powered, no battery required) |
| Compliance | Designed for IEC 60705:2017 (Household Microwave Ovens – Methods for Measuring Performance) and FDA 21 CFR §1030.10 (Performance Standard for Microwave and Radio Frequency Emitting Products) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ML-91 |
| Price | USD 950 (FOB Jiangsu) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | 66 % ±15 % RH |
| Atmospheric Pressure | 750 mmHg ±30 mmHg |
| Frequency Band | 3–33 cm (i.e., 0.9–10 GHz) |
| Power Density Range | 0.2 µW/cm² to 20 mW/cm² |
| Display | 3-digit LED, auto-ranging across 200 µW/cm² / 2 mW/cm² / 20 mW/cm² scales with LED range indicators |
| Alarm Threshold | Adjustable, default ≥5 mW/cm² |
| Calibration Field Accuracy | ±0.75 dB |
| Full-Scale Indication Error (at rated voltage) | ≤±1.5 % |
| Indicator Dimensions | 82 mm × 40 mm × 172 mm |
| Net Weight | 0.8 kg |
| Brand | Huiyan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MY8C-1 |
| Price | Upon Request |
| Microwave Frequency | 2450 MHz ± 50 MHz |
| Output Power Range | 0–200 W (continuous, linearly adjustable) |
| Waveguide Standard | GB/T BJ-26 (FD-26 flange) |
| Cavity Material | Stainless Steel |
| Control Interface | Industrial-grade color touchscreen with embedded microcomputer controller |
| Power Density Monitoring | Real-time display of source output power and cavity-internal power density |
| Calibration | User-configurable power density calibration coefficient |
| Data Visualization | Real-time power density trend curve (sampling-based) |
| Operation Modes | Dual-mode dynamic power density regulation |
| Radiation Mode | Waveguide-fed cavity irradiation or free-space radiation via optional waveguide antenna |
| Brand | Microwise |
|---|---|
| Origin | Denmark |
| Model | BallastWISE |
| Portability | Portable |
| Biological Target | Algal and zooplanktonic organisms |
| Operating Temperature | 0–40 °C |
| Reagent Storage Temperature | 0–40 °C |
| Repeatability | ±1% |
| Sample Throughput | Per batch |
| Analysis Time | 5 s |
| Detection Principle | Dual-mode fluorescence imaging + motility-based viability assessment |
| Size Classes Quantified | 10–50 µm and >50 µm |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Cement Waste Heat Power Generation Water Quality Test Kit |
| Measurement Principle | Visual Colorimetric Analysis (Standardized Reagent-Based Method) |
| Test Parameters | Phosphate (3–120 ppm), Chloride (2 mg/L detection limit |
| Test Frequency | 190–300 determinations per reagent vial |
| Compliance | Designed for routine industrial water monitoring in accordance with ISO 9001-supported QA/QC workflows and aligned with ASTM D511 (chloride), ASTM D5845 (phosphate), and ISO 6059 (hardness) test method principles |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | NOVA 60 |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | COD, Heavy Metals, Ammonia-Nitrogen (NH₄-N), Cyanide |
| Key Features | Integrated photometric measurement platform with 12-wavelength LED optical system (240–820 nm), 126 pre-programmed methods covering 50 water quality parameters, 1000-test data storage, compatibility with 16 mm tubes and 10/20/50 mm cuvettes, temperature-compensated optics, battery-powered (9 V, 40 h continuous operation) |
| Brand | Starwood |
|---|---|
| Model | ZLFI00001 |
| Membrane Diameter | 47 mm |
| Membrane Pore Size | 0.45 µm |
| Test Pressure | 2.0–2.2 bar (29–32 psi) |
| SDI Calculation Interval | 0–5–15 min |
| Compliance | ASTM D4189-95 |
| Includes | Pressure Regulator, 47 mm Filter Holder, ASTM-Compliant Mixed Cellulose Ester (MCE) Membranes |
| Accessories Required | 500 mL Graduated Cylinder (±5 mL graduation), Stopwatch (±0.2 s resolution) |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Pharo 100 |
| Wavelength Range | 320–1100 nm |
| Light Source | Tungsten Halogen Lamp |
| Optical System | Stabilized Single-Beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (A < 0.600) |
| Cuvette Compatibility | 16 mm round, 10/20/50 mm square (auto-recognized) |
| Scan Increment | 1 nm |
| Data Storage | 1000 measurement results + 4 MB for spectral/dynamic data |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS-232 |
| IP Rating | IP31 |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm (L×H×W) |
| Weight | ~3.7 kg |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | Pharo 300 |
| Wavelength Range | 190–1100 nm |
| Light Source | Xenon flashlamp |
| Optical System | Stabilized single-beam |
| Spectral Bandwidth | 4 nm |
| Wavelength Resolution | 1 nm |
| Wavelength Accuracy | ±1 nm |
| Absorbance Range | ±3.3 A |
| Absorbance Resolution | 0.001 A |
| Absorbance Accuracy | ±0.003 A (A < 0.600 A) |
| Scan Increment | 1 nm |
| Cuvette Types | 16 mm round |
| Barcode Recognition | Full support for Spectroquant® pre-filled tubes and reagent sets |
| AQA Levels | AQA 1 (wavelength verification), AQA 2 (system performance verification), AQA 3 (matrix interference screening) |
| Data Storage | 1000 measurement results |
| Interfaces | 1× USB-A, 1× USB-B, 1× RS-232 |
| Display | Backlit graphical LCD |
| Languages | English, German, Spanish, French, Italian, Simplified Chinese |
| IP Rating | IP31 |
| Operating Temperature | +10 °C to +35 °C |
| Dimensions | 404 × 197 × 314 mm (L × H × W) |
| Weight | ~3.7 kg (without battery) |
| Brand | Millipore |
|---|---|
| Origin | Germany |
| Model | HY-lite |
| Portability | Handheld, Battery-Powered |
| Detection Principle | Firefly Luciferase–Mediated Bioluminescence |
| Measurement Range | 0.01–999.9 RLU (Relative Light Units) |
| Response Time | ≤60 seconds |
| Data Storage Capacity | 2,000 test records |
| Interface | USB 2.0 for PC connectivity |
| Optional Peripherals | Integrated thermal printer module, surface swab pens, liquid sampling pens, jet fuel test kits, free ATP assay pens, ATP calibration standards (0.0 ng/mL) |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned hygiene verification workflows |
| Brand | Millipore |
|---|---|
| Origin | Switzerland |
| Model | MAS-100 CG Ex |
| Sampling Principle | Impaction-based Active Separation |
| Flow Rates | 50 L/min and 100 L/min (selectable, constant) |
| Flow Measurement Accuracy | ±0% to +10% at 50 L/min or 100 L/min over absolute pressure range of 1.5 bar to 10 bar |
| Total Operating Time | Approx. 3.5 h per battery charge |
| Ambient Temperature Range | 0–40°C |
| Ambient Relative Humidity | Up to 80% RH at ≤31°C, linearly decreasing to 50% RH at 40°C |
| Certifications | ATEX II 2G Ex db IIB T4 Gb / II 2D Ex tb IIIC T135°C Db (for use in Zone 1 & Zone 21 hazardous areas) |
| Brand | Millipore |
|---|---|
| Origin | Switzerland |
| Model | MAS-100 ECO |
| Sampling Principle | Impaction-based Active Air Sampling |
| Flow Range | 1–1000 L/min |
| Flow Accuracy | ±4% at 100 L/min |
| Total Operating Time | Approx. 3 hours |
| Operating Temperature | 0–40 °C |
| Operating Relative Humidity | 0–80% RH (non-condensing) |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MVP ICON™ |
| Pricing | Available Upon Request |
| Brand | Mingguang Lihua |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SG-1 |
| Weight | 50 g |
| Power Supply | Rechargeable Lithium Battery |
| Operating Modes | Manual & Auto (30 s cycle) |
| Continuous Operation Time | Up to 16 minutes |
| Refill Cartridge | Replaceable top-mounted cartridge containing food-grade propylene glycol and glycerol |
| Illumination | Integrated LED light for low-light visibility |
| Compliance | RoHS-compliant formulation |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SDCY-6000D |
| Automation Level | Semi-Automatic |
| Sampling Depth | 1200 mm |
| Sampling Capacity | 0–5 kg per cycle |
| Max Particle Size | 60 mm |
| Motor Power | 1.2 kW |
| Operating Voltage | 220 V AC |
| Sampler Weight | 20 kg |
| Auger Tube Diameter | Φ133 mm |
| Overall Dimensions | 1660 × 500 × 300 mm |
| Brand | Minhope |
|---|---|
| Model | MH1200-G |
| Origin | Shandong, China |
| Instrument Type | Integrated Ambient Air Sampler for TSP, PM₁₀, PM₂.₅, Heavy Metals, Fluorides, and Semi-Volatile Organic Compounds (SVOCs) |
| Compliance | JJG 943–2011, HJ 618–2011, HJ 93–2013, HJ 691–2014 |
| Operating Modes | Instant, Timed, and Volume-Based Sampling |
| Environmental Parameter Compensation | Real-time Temperature & Barometric Pressure Measurement with Flow Correction |
| Enclosure | Weather-Resistant, Compact, Low-Noise Design |
| Power Consumption | Low |
| Weight | Lightweight for Field Deployment |
| Brand | Minhope |
|---|---|
| Model | MH3010-E |
| Construction Material | Titanium Alloy Probe Body |
| Heating Zones | Dual-Zone (Probe Tip & Filter Holder) |
| Compliance | HJ 77.2–2008, HJ/T 365–2007, GB/T 16157–1996, JJG 680–2007, JJG 968–2002 |
| Application | Isokinetic Sampling of Gas-Phase and Particulate-Bound Dioxins/Furans from Municipal Solid Waste Incinerators and Hazardous Waste Combustors |
| Operating Temperature Range | Ambient to 250 °C (adjustable, ±1 °C stability) |
| Probe Length | Standard 1.2 m (custom lengths available) |
| Filter Holder | Quartz Fiber Filter + Polyurethane Foam (PUF) Sorbent Trap |
| Pitot Tube | Rotatable, Stainless Steel, Integrated with Differential Pressure Sensor |
| Data Interface | Analog 4–20 mA outputs for temperature, velocity, and static/dynamic pressure |
| Origin | UK |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Minimet Automatic Weather Station |
| Price | Upon Request |
| Brand | MINSPEC |
|---|---|
| Model | MP-5600Plus |
| Origin | Shandong, China |
| Detection Targets | ODS (CFCs, HCFCs, Halons, Methyl Bromide), VOCs, SVOCs |
| Sample Matrices | Ambient Air, Water (via Headspace), Soil (via Purge-and-Trap or Thermal Desorption), Refrigerant Gases |
| Compliance | GB/T 32210–2015, HJ 11223–2021, HJ 1227–2021, HJ 1058–2019 |
| Detection Principle | Capillary GC separation coupled with linear ion trap MS detection |
| Ionization Mode | Electron Ionization (EI), inertized high-temperature source (up to 300 °C) |
| Preconcentration | Integrated cryogenic trapping (down to 0 °C) |
| Mass Analyzer | Dual-curved linear ion trap |
| Dynamic Range | 7 orders of magnitude |
| Internal Standard Delivery | Automated, inertized, programmable syringe-based introduction |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Model | Aluminum Ion Detector |
| Type | Portable Multi-Ion Analyzer |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed for Field-Deployable Water Quality Monitoring per ISO 10523, ASTM D3590, and EPA Method 200.7 (ICP-OES reference correlation) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Quartz Crystal Microbalance (QCM) with Gold-Plated Fluoride-Specific Sensor Chip |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Regulatory Compliance | Designed for ISO 10523, ASTM D4192, and EPA Method 300.0–compatible workflows |
| Software Interface | USB-C–enabled embedded firmware with real-time data streaming and CSV export |