Food Specialized Instruments
Filter
Showing 601–630 of 796 results
| Brand | Sanotac |
|---|---|
| Model | B1001 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Protein Quantification Analyzer |
| Detection Principle | Magnetic Immuno-Chromatographic Assay (MIC) coupled with Dual-Wavelength UV-Vis Absorption Spectrophotometry |
| Wavelength Range | 190–700 nm (simultaneous dual-wavelength detection) |
| Wavelength Repeatability | ±0.2 nm |
| Wavelength Accuracy | ±1 nm |
| Detection Limit | 5×10⁻⁹ g/mL |
| Recovery Rate | 99% |
| Optical Path Length | Adjustable (1–5 mm) |
| Baseline Noise | ±0.5×10⁻⁵ AU (254 nm, TC = 1 s) |
| Baseline Drift | 1.5×10⁻⁴ AU (254 nm, 1 h) |
| Absorbance Range | 0–3 AU |
| Time Constants | 0.1 / 0.2 / 0.5 / 1.0 / 2.0 / 5.0 / 10.0 s |
| Light Source | Integrated Deuterium Lamp + Tungsten-Halogen Lamp (auto-switching) |
| Flow Cell Interfaces | 1/16″ for analytical/semi-preparative, 1/8″ for preparative applications |
| Data Interface | USB + RS-232 |
| Software Compliance | FDA 21 CFR Part 11, CFDA GxP, GLP/GMP-ready audit trail and electronic signature support |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-ATP |
| Display | 3.5-inch full-color touchscreen (≥5-color UI) |
| Processor | 32-bit high-speed data processing IC |
| Detection Time | 15 s |
| Measurement Interference | ±5% or ±5 RLU |
| Operating Temperature | 5–40 °C |
| Operating Humidity | 20–85% RH |
| Output Unit | RLU (Relative Light Unit) |
| Pass/Fail Auto-Judgment | Yes |
| Compliance Reporting | Automatic pass rate statistics |
| Built-in Calibration Light Source | Yes |
| Power-On Self-Test Duration | 30 s |
| Connectivity | Mini-USB port + integrated Wi-Fi module |
| Software Delivery | Dedicated USB drive (no CD) |
| Dimensions (W×H×D) | 188 × 77 × 37 mm |
| Power Supply | Rechargeable lithium-ion battery |
| Standby Life (20 °C) | 6 months |
| Standard Accessories | Host unit, aluminum carrying case, driver USB stick, PC data cable, desktop data analysis software, Chinese user manual |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-JMTY |
| Price | USD 340 (approx.) |
| Dimensions | 850 × 200 × 130 mm |
| Measurement Range | 0–600 mL (Scale I) and 400–1000 mL (Scale II) |
| Displacement Medium | Rapeseed (1–2 mm particle size) |
| Accuracy | ≤ ±1.0% |
| Repeatability | ≤ ±0.8% |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-JMTY |
| Price | USD 340 (FOB) |
| Dimensions | 850 × 200 × 130 mm |
| Measurement Range | 0–600 mL (Scale I), 400–1000 mL (Scale II) |
| Displacement Medium | Rapeseed (1–2 mm particle size) |
| Accuracy | ≤ ±1.0% |
| Repeatability | ≤ ±0.8% |
| Brand | Santiyiqi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ST-L01T |
| Price | USD 1,390 (approx. based on ¥9,800 at 1 USD = ¥7.1) |
| Brand | Santiyiqi |
|---|---|
| Model | ST-PA |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price | USD 2,800 (approx.) |
| Dimensions | 160 × 70 × 30 mm |
| Weight | 350 g |
| Battery Capacity | 1000 mAh |
| Operating Time | 4 h |
| Sampling Interval | ≤1 s |
| Accuracy Range | 70–85% |
| Measurement Uncertainty | ±15–30% |
| Measured Parameters | Total Viable Count (TVC), pH, Total Volatile Basic Nitrogen (TVB-N), Freshness Index, CIELAB Color Coordinates (L*, a*, b*) |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GCB-28 |
| Power Supply | 220 V AC |
| Sample Capacity | 28 positions |
| Temperature Control Accuracy | ±0.1 °C |
| Brand | Saprete |
|---|---|
| Model | GCT-28A |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Power Supply | 220 V AC |
| Sample Capacity | 28 positions |
| Temperature Control Accuracy | ±0.1°C |
| Data Storage | Up to 4 Historical Test Groups |
| Compliance | Designed for GB/T 17891–2018, ISO 6647-1:2022, and AACCI Method 61-02 |
| Brand | Saprete |
|---|---|
| Model | GCT-8A |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Power Supply | 220 V AC |
| Sample Capacity | 8 positions |
| Temperature Control Accuracy | ±0.1 °C |
| Operating Ambient Temperature | 25 °C (constant) |
| Data Storage | Up to 4 historical test records |
| Optional Accessory | Rice Gel Sample Preparation Mill |
| Brand | Saprete |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Saprete Instrument Co., Ltd. |
| Type | Domestic |
| Model | HP-4A |
| Power Supply | 220 V AC |
| Compliance | Designed per GB/T 25222–2010 |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SBA-40E |
| Pricing | Available Upon Request |
| Brand | Schaller |
|---|---|
| Origin | Austria |
| Model | RH2 |
| Water Activity Range | 0.03–0.99 aw |
| Resolution | 0.001 aw |
| Calibration Accuracy | ±0.01 aw (at 0.10–0.80 aw) |
| Temperature Range | Not specified (sensor-dependent) |
| Relative Humidity Range | Sensor-dependent |
| RH Resolution | 0.1 %RH |
| Temperature Resolution | 0.1 °C |
| Dew Point Range | −55 to +60 °C |
| Absolute Humidity Range | 0–130 g/m³ |
| Absolute Humidity Resolution | 0.1 g/m³ |
| Equilibrium Moisture Content (Wood) | 2–30 %, 0.1 % resolution |
| Equilibrium Moisture Content (Granules) | 0.1 % resolution |
| Data Storage Capacity | 10,000 measurements |
| Dimensions | 145 × 75 × 30 mm |
| Weight | 210 g (with batteries) |
| Power Supply | 4 × 1.5 V AA alkaline batteries |
| Display Languages | English, German, French, Spanish, Portuguese, Italian, Russian, Czech, Polish |
| Compliance | EN ISO 21807 |
| Brand | SDM |
|---|---|
| Origin | Italy |
| Model | 2440 |
| Temperature Range | Ambient to 210 °C (±0.1 °C stability) |
| Compliance | ASTM D2440, IP 307, ISO 7624, IP 48, IP 280, IP 306, IP 335, EN 61125-A/B/C |
| Construction | Double-walled stainless steel housing with thermal insulation |
| Temperature Control | PID controller with PT100A sensor and over-temperature alarm |
| Heating System | Stainless steel immersion heater |
| Agitation | Motor-driven magnetic stirrer |
| Safety Features | Low-level liquid sensor with visual alarm, drain cock, ventilated lid with ports for flowmeter and absorption tube |
| Power Supply | 220 V, 50/60 Hz |
| Origin | China |
|---|---|
| Manufacturer Type | Distributor |
| Model | S-Series |
| Capacity Range | HJ-400-S to HJ-1500-S |
| Pelleting Accuracy | 100% Single-Seed Encapsulation |
| Applicable Materials | Vegetable, Cereal, Cotton, Oilseed, Forage, and Forestry Seeds |
| Core Technology | German RTF (Rotational Torque Fluidization) Coating System |
| Compliance | Designed for ISO 9001-certified seed processing environments |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SEN582 |
| Light Source | Simulated D65 Illuminant |
| Color Space | CIE L*a*b* |
| Bran Speck Content | Ratio of bran speck area to total sample surface area (%) |
| Whiteness | Blue-light Whiteness (Wb) |
| Display | Large LCD Touchscreen |
| Whiteness Resolution | ≤0.1 |
| Bran Speck Repeatability | Relative difference between duplicate measurements < 10% of arithmetic mean |
| Colorimetric Repeatability | ΔE*ab ≤ 0.5 |
| Preheat Time | 30 min |
| Power Supply | 220 V ±10%, 50 Hz |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤85% RH |
| Compliance | GB/T 27628–2011, Verified by National Grain Quality Inspection Center |
| Brand | SENTE |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Producer |
| Country of Origin | China |
| Model | ST109A |
| Pricing | Available Upon Request |
| Brand | SENTE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | STAW100 |
| Instrument Category | Beer-Specific Analyzer |
| Application | Laboratory Use |
| Distillation Time | 40 min |
| Ethanol Concentration Range | 0–65% v/v |
| pH of Condensate (Reference) | 7 |
| Dimensions (L×W×H) | 960 × 575 × 410 mm |
| Weight | 60 kg |
| Key | Origin: Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | SGD-IV |
| Pricing | Available Upon Request |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 421 × 342 × 230 mm |
| Weight | 12 kg |
| Display | Integrated LCD Panel |
| Sensitivity | 0.01% (w/v, expressed as glucose) |
| Linear Range | 0.01–1.00% (w/v, expressed as glucose) |
| Assay Time | ≤ 3 minutes |
| Brand | Shanda |
|---|---|
| Model | SD-GCT-28A |
| Sample Capacity | 28 positions |
| Power Supply | 220–230 V, 50 Hz |
| Operating Temperature Range | 5–40 °C |
| Relative Humidity | 10–85% |
| Temperature Control Accuracy | 25 °C ± 2 °C |
| Software | PC-based workstation software with real-time hardware monitoring, error code display, Excel export, color-coded batch labeling, and historical data retrieval |
| Optional Accessories | Rice sample preparation mill, dedicated PC, water-cooling unit |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | SD-HQMG |
| Price | USD 1,390 (FOB) |
| Function Type | Multi-analyte Detection Platform |
| Sample Scope | Universal for Cereals, Oilseeds, Feed Matrices, and Processed Food Commodities |
| Main Controller | ARM Cortex-A7 |
| Detection Channels | ≥12 independent optical channels |
| Display | 10.1-inch HD vertical capacitive touchscreen (1280×800) |
| Communication Interfaces | Integrated Wi-Fi (802.11 b/g/n), RJ45 Ethernet port, USB 2.0 host/device |
| Power Supply | DC 12 V — compatible with vehicle power outlets |
| Data Storage | Internal eMMC (16 GB) + USB flash drive support (FAT32/exFAT) |
| Dimensions (W×D×H) | 430 × 350 × 190 mm |
| Net Weight | 5.1 kg |
| Light Source | Precision imported quad-wavelength cold LED source (450 nm, 520 nm, 590 nm, 630 nm) |
| Processor | Rockchip RK3288 (ARM Cortex-A17 quad-core, 1.8 GHz) |
| Brand | Shanda |
|---|---|
| Model | SD-PE-T |
| Type | Electronic Farinograph |
| Power Supply | 220 V AC, 50 Hz |
| Motor Power | 300 W |
| Rotational Speed Range | 2–200 ±1 rpm (adjustable, real-time display) |
| Speed Ratio (Fast/Slow Blades) | 1.5:1 |
| Torque Measurement Range | 0–20 N·m |
| Torque Sensor Accuracy | ≤0.3% FS |
| Bowl Capacity | 300 g |
| Torque Unit Calibration | (9.8 ± 0.2) mN·m per Farinograph Unit (FU) |
| Measuring Range | 0–2000 FU |
| Water Addition Accuracy | ±0.2 mL (for 300 g dough) |
| Water Bath Pressure | ≤340 mbar |
| Water Circulation Flow Rate | 15 L/min (auto-fill enabled) |
| Dough Temperature Control | 30 ± 0.2 °C (PID-controlled water jacket) |
| Temperature Setting Range (Incubation Chamber) | 20–50 °C |
| Chamber Temperature Stability | ±0.2 °C |
| Chamber Power | 1200 W |
| Chamber Display | 5-inch embedded LCD touch screen |
| Safety Features | Overload protection (bowl), mechanical/electrical interlock (mixer), real-time heating element monitoring, automatic alarm on anomaly |
| Material | Imported stainless steel (bowl & blades), corrosion-resistant surface-treated structural components |
| Compliance Standards | ICC 115/1, AACC 54-21, ISO 5530-1, GB/T 14614 |
| Data Handling | Multi-file curve overlay (unlimited), custom color/name assignment, cross-brand farinogram import (legacy formats), real-time interruption & interim calculation, encrypted storage, export to CSV/Excel, GLP-compliant audit trail (via Smart Pbox integration) |
| Software | Windows 7/10 native, perpetual license, free lifetime updates |
| Service | Annual certified standard-sample calibration (with CNAS-accredited reference material certificate), two free post-warranty calibration & maintenance visits (Years 2–3), third-party performance evaluation report issued by national metrology institute |
| Connectivity | Real-time multi-terminal data viewing (requires Smart Pbox gateway) |
| Brand | Shanda |
|---|---|
| Model | SD-RXS |
| Origin | Shandong, China |
| Measurement Principle | Compression-based Gravimetric Method (NY/T 821–2004) |
| Force Range | 0–3000 N |
| Resolution | 0.1 N |
| Accuracy | ±1% FS |
| Compression Speed | 1–300 mm/min |
| Dwell Time | 1–3600 s |
| Deformation Range | 1–70 mm |
| Platen Diameter | 110 mm |
| Parallelism | <0.05 mm |
| Dimensions | 450 × 450 × 680 mm |
| Weight | ~45 kg |
| Power Supply | AC 220 V, 50 Hz |
| Brand | Ruixin |
|---|---|
| Origin | Shanghai, China |
| Model | JT-102M |
| Detection Principle | Colloidal Gold Immunochromatographic Assay (CGIA) with CCD-based quantitative optical densitometry |
| Wavelength Range | 380–680 nm |
| Detection Time | ≤8 min per sample |
| Repeatability (CV) | ≤1% (standard test strip) |
| Inter-batch Variation | <3% |
| Detection Channels | Single-channel |
| Quantitative Output | T/C ratio, colorimetric intensity, line intensity calibration |
| LOD for DON | 200 ppb |
| Quantitative Range for DON | 200–8000 ppb |
| Data Storage | ≥100,000 records (32 GB internal SSD) |
| Connectivity | Wi-Fi 5 (802.11ac), Bluetooth 4.2, USB 2.0, optional 4G LTE module |
| Power Supply | AC 220 V / DC 5 V / Internal Li-ion battery (≥24 h standby) |
| Display | 8.1″ capacitive touchscreen (1280×800), Windows OS |
| Processor | Intel quad-core (14 nm), 2 GB RAM, integrated graphics |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST-149 |
| Price Range | USD 28,000–71,000 |
| Standard Compliance | GB/T 21121-2007, ISO 6886:2006, JIS CDM 2.4.28.2-93 |
| Sample Mass | 3 g |
| Temperature Control Range | Ambient to 220 °C |
| Max Safety Cut-off | 260 °C |
| Heating Method | Metal Bath with Four Independent Zones |
| Air Flow Range | 1–30 L/h at 25 °C and 101.325 kPa |
| Conductivity Measurement Range | 0–500 µS/cm |
| Conductivity Resolution | 0.1 µS/cm |
| Data Storage Capacity | 199 test records |
| Output Format | CSV / Excel via USB flash drive |
| Display | 7-inch color LCD touchscreen |
| Software | Embedded & PC-compatible OSI calculation engine with second-derivative induction point detection |
| Dimensions (W×D×H) | 420 × 390 × 480 mm |
| Net Weight | 26 kg |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ST006 |
| Power Supply | 220 V, 50 Hz |
| Stirring Rod Mass | 25 g ± 0.05 g |
| Viscometer Tube Inner Diameter | 21 mm ± 0.02 mm |
| Outer Diameter | 23.8 mm ± 0.25 mm |
| Internal Height | 220 mm ± 0.3 mm |
| Heater Power | 600 W |
| Measurement Accuracy | < 5% |
| Package Dimensions | 550 × 475 × 510 mm |
| Net Weight | 36 kg |
| Brand | Shengtai Instruments |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | ST-1700 |
| Weight | 65 kg |
| Dimensions | 67 × 51 × 79 cm (L×W×H) |
| Roller Speed (Fast/Slow) | 1200 / 550 rpm |
| Power Supply | AC 380 V / 50 Hz or AC 220 V / 50 Hz |
| Grinding Capacity | 0–100 g/min |
| Flour Yield | 60–70 % |
| Ash Content (dry basis) | ≤0.7 % |
| Roller Diameter × Length | φ70 × 30 mm |
| Motor Power | 550 W |
| Brand | Shengtai (SENTE) |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | ST109C |
| Price Range | USD 7,000 – 14,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | EZ Test |
| Price Range | USD 14,000 – 42,000 |
| Brand | Skalar |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SP2000 Beer |
| Instrument Category | Beer-Specific Analyzer |
| Application Environment | Laboratory |
| Cycle Time per Sample | 8 min |
| Alcohol Content Detection | Not Applicable |
| pH Range | –2.0 to +16.0 |
| Dimensions (L × W × H) | 75 × 70 × 121 cm |
| Weight | 90 kg |
| Brand | SMS |
|---|---|
| Origin | United Kingdom |
| Model | DR/DIS |
| Application | Dough bubble expansion rheometry |
| Measurement Principle | Piston-driven volumetric inflation with real-time pressure–volume–time profiling |
| Compliance | Designed for ASTM AACC 54-30A, ISO 21502, and GLP-aligned bakery R&D workflows |
| Software | Windows-native data acquisition & analysis suite with macro scripting, spreadsheet-integrated calculations, and export-ready charting |