Food Specialized Instruments
Filter
Showing 691–720 of 796 results
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CLA-FS3L |
| Price Range | USD 14,000 – 28,000 |
| Brand | AGDIA |
|---|---|
| Origin | USA |
| Model | ISK66800/0025 |
| Format | Lateral Flow Immunoassay (LFIA) |
| Target | ToBRFV coat protein |
| Detection Limit | ≤1 ng/mL in infected leaf or fruit tissue extracts |
| Assay Time | 10–15 minutes |
| Storage | 2–8 °C, desiccated |
| Shelf Life | 18 months from manufacture |
| Regulatory Status | For research and diagnostic use only |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | SJ-12A |
| Power Supply | 220 V AC / 50 Hz |
| Price Range | USD 16,500 – 27,500 (FOB China) |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Model | TGL-I / TGL-II / TGL-III |
| Power Supply | 220 V AC, 50 Hz |
| Application | Paddy husking for糙米 (brown rice) preparation in grain quality testing |
| Compliance | GB/T 5495–2008 “Grain and Oil Inspection — Determination of Brown Rice Yield” |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TGY-15A |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 500 W |
| Dimensions (W×D×H) | 630 × 445 × 413 mm |
| Sample Capacity | 15 positions |
| Minimum Dispensing Volume | 20 µL |
| Dispensing Accuracy | ≤0.5% |
| Titration Error | ≤0.25% |
| Color Response Time | ≤10 ms |
| Detection Time (15 samples) | ~40 min (sample-dependent) |
| Temperature Control Range | 30–80 °C |
| Endpoint Detection Method | Non-contact spectrophotometric colorimetry |
| Reagent Auto-selection | Starch indicator, saturated potassium iodide solution, Grade III water |
| Titration Mode | Automatic colorimetric titration with blank correction |
| Stirring | Adjustable-speed magnetic stirring |
| Cleaning | Fully automated fluidic line rinse |
| Calibration | Multi-point user-defined calibration support |
| Data Output | Real-time thermal printing + cloud upload via Wi-Fi or Ethernet |
| Control Interface | 10-inch capacitive touchscreen or remote web-based management |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Model | TMJ-II |
| Gluten Washing Time | 5 min (standard) |
| Mixer Speed | 120 rpm ±1 rpm |
| Dough Mixing Time | 20 s |
| Washing Flow Rate | 40–60 mL/min (adjustable, nominal 50 mL/min) |
| Centrifugation Speed | 6000 rpm |
| Centrifugation Sieve Aperture | 500 µm |
| Index Sieve Aperture | 600 µm |
| Drying Temperature Range | 150–200 °C |
| Power | 650 W |
| Dimensions | 400 × 380 × 270 mm |
| Voltage/Frequency | 220 V / 50 Hz |
| Compliance | GB/T 5506.1–2008 |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Model | TNM-I |
| Sample Capacity | 10–20 g (optimal: ~16 g) |
| Broken Grain Rate | ≤5% for Japonica rice, ≤10% for Indica rice |
| Grinding Chamber Diameter | 95 mm |
| Time Setting Range | 1–99 s (adjustable in 1-s increments) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Net Weight | 3.5 kg |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Model | TON-IV |
| Instrument Category | Aflatoxin Analyzers |
| Detection Principle | Fluorescent Quantitative Immunoassay (Lateral Flow Immunochromatography) |
| Target Analytes | Aflatoxin B1 & M1, Zearalenone, Deoxynivalenol (DON), Fumonisin, Ochratoxin A, T-2 Toxin |
| Detection Range | 0.1 ppb – 10 ppm (for AFB1 and DON) |
| Limit of Detection (LOD) | 0.1 ppb (for AFB1 and DON) |
| Coefficient of Variation (CV) | ≤0.8% |
| Throughput | 4 parallel channels |
| Sample Processing | Fully automated extraction, vortexing, transfer, and assay incubation |
| System Architecture | Sealed XYZ robotic platform with integrated cleaning station |
| Compliance | Designed for GLP-compliant environments |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Model | TON-IVB |
| Power Supply | 220 V / 50 Hz |
| Dimensions | 400 × 380 × 270 mm |
| Rated Power | 500 W |
| Sample Throughput | 1–4 samples per run |
| Sample Preparation | Automated magnetic stirring (programmable timing) + positive-pressure filtration |
| Liquid Handling | Disposable TIP pipette tips |
| Detection Method | Time-resolved fluorescence immunochromatography (TRFIA) |
| Compliant Standards | LS/T 6143–2023, LS/T 6112–2015, LS/T 6114–2015, KJ 201702, KJ 202201, KJ 202106 |
| Analytes | Aflatoxin B₁ (LOD: 0.5 µg/kg, Range: 0–75 µg/kg), Deoxynivalenol (LOD: 25 µg/kg, Range: 0–5000 µg/kg), Zearalenone (LOD: 5 µg/kg, Range: 0–1000 µg/kg), Ochratoxin A (LOD: 1 µg/kg, Range: 0–500 µg/kg), T-2 Toxin (LOD: 25 µg/kg, Range: 0–5000 µg/kg), Fumonisins (LOD: 50 µg/kg, Range: 0–5000 µg/kg) |
| Recovery Rate | 80–125% |
| Coefficient of Variation (CV) | ≤12% |
| Brand | Tongxintianbo |
|---|---|
| Model | TRI-III |
| Origin | Beijing, China |
| Power Supply | 220 V / 50 Hz |
| Dimensions | 500 × 450 × 350 mm |
| Power Consumption | 500 W |
| Endpoint Detection | Colorimetric (variable-spectrum photometric sensor) |
| Color Response Time | 10 ms |
| Minimum Dispensing Volume | 0.001 mL |
| Sample Cup Capacity | 50 mL / 100 mL (customizable) |
| Dispensing Accuracy | ≤0.25% per 10 mL |
| Dispensing Precision (RSD) | ≤0.5% per 10 mL |
| Titration Error | ≤0.25% per 10 mL |
| Display | 7-inch capacitive touchscreen |
| Communication Interfaces | RS232, Wi-Fi |
| Sample Handling | Magnetic stirring |
| Automation Features | Auto-blank correction, auto-pipette cleaning, cup-empty detection, adaptive titration speed control, endpoint overshoot recognition and stop |
| Brand | Tongxintianbo |
|---|---|
| Model | TRI-III-ZF (1-, 2-, 4-, or 8-channel configuration) |
| Origin | Beijing, China |
| Power Supply | 220 V AC / 50 Hz |
| Channel Options | Single, Dual, Quad, or Octal |
| Compliance | Designed for GB/T 15684–2015, ISO 660, and AOAC Official Method 940.28 |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TX-GBR8 |
| Power Supply | 220 V AC, 50 Hz |
| Throughput | 8 samples per run |
| Compliance | GB/T 17891–2018, NY/T 234—2016 |
| Brand | Tongxintianbo |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TX-IGS100 |
| Power Supply | 220 V AC, 50 Hz |
| Detection Principle | High-Resolution Digital Imaging + AI-Powered Morphological Classification |
| Connectivity | Ethernet & USB 2.0 |
| Data Output | CSV, PDF, XML (GLP-compliant audit trail optional) |
| Compliance | GB/T 5494–2019, ISO 7971-2:2017, AOAC 992.15 |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DPCZ-II |
| Detection Wavelength | 650 nm |
| Measurement Accuracy | ±0.001 (absorbance unit) |
| Sample Types | Rice, Corn, Wheat, and other cereal grains |
| Measurement Time | ~60 seconds per sample |
| Operating Temperature Range | 20–30 °C |
| Power Supply | 220 ±1 V AC |
| Software Platform | Windows-based proprietary control software |
| Compliance | Designed for routine QC in food-grade laboratories compliant with GB/T 15683-2008 (Chinese national standard for amylose determination in rice) |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HZF-150 |
| Motor Power | 0.2 kW |
| Torque Range | 1–10 N·m |
| Accuracy | ≤5% of full scale |
| Main Mixer Blade Speed | 63 ±1 rpm |
| Auxiliary Mixer Blade Speed | 94.5 ±1 rpm |
| Time Axis Range | 0–20 min |
| Resistance Axis Range | 0–1000 FU |
| Sample Mass | 300 g or 50 g (interchangeable bowls) |
| Torque Sensitivity | 9.8 mN·m/FU (300 g bowl), 1.96 mN·m/FU (50 g bowl) |
| Chart Speed | 1.00 mm/min |
| Data Format | Microsoft Access (.accdb) |
| Interface | USB 2.0, hot-pluggable |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | JSWL-II |
| Price | USD 20,800 (FOB) |
| Detection Principle | Near-Infrared (NIR) Transmittance Spectroscopy |
| Wavelength Range | 700–1050 nm |
| Spectral Resolution | < 7 nm |
| Detector | 256-element Si photodiode array |
| Measurement Mode | Transmittance |
| Sample Form | Whole-grain brown rice and milled rice (indica & japonica) |
| Key Parameters Measured | Moisture, Protein, Amylose Content, Taste Score (Rice Taste Value) |
| Measurement Time | < 180 s |
| Operating Temperature | −10 °C to 40 °C |
| Relative Humidity Limit | ≤ 85 % RH |
| Weight | < 15 kg |
| Power Options | AC 110–220 V, DC 12–15 V (external battery), or internal Li-polymer battery (≥2 h runtime) |
| Display | 8-inch capacitive multi-touch TFT color screen |
| Storage | ≥16 GB SSD |
| Connectivity | Dual USB 2.0 ports, Ethernet, Wi-Fi |
| Software | Embedded OS with model management, audit-trail-capable data logging, GLP-compliant metadata tagging (date/time, operator ID, sample ID, calibration status) |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JXFM110 |
| Price Range | USD 1,250 – 1,680 |
| Power Supply | AC 220 ±10 V, 50 Hz |
| Motor Power | 750 W |
| Grinding Chamber Diameter | 110 mm |
| Hammer Rotational Speed | 16,800 rpm |
| Sieve Aperture Options | 0.5 mm, 0.8 mm, 1.5 mm |
| Net Weight | 51 kg |
| Noise Level | <72 dB(A) |
| Thermal Protection | Built-in motor temperature cutoff switch (auto-restart upon cooling) |
| Feed Control | Compatible with optional automated feeder for high-moisture and hulled cereals |
| Sample Compatibility | Wheat, rice (paddy), corn, barley, oats, rye, sorghum, soybean meal |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | JYSY30×8 |
| Price | USD 920 (approx.) |
| Sieve Diameter | 300 mm |
| Sieve Height | 30 mm |
| Orbit Diameter | 50 mm |
| Rotational Speed | 260 rpm |
| Sample Mass | 50.0 g |
| Timer Range | 0–999 s |
| Motor Power | 60 W |
| Standard Sieve Set | CQ10 (25 mesh), CQ16 (41 mesh), CQ20 (51 mesh), CQ27 (69 mesh), CB30 (76 mesh), CB36 (91 mesh), CB42 (107 mesh) |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KDN-08C |
| Product Category | Protein Determinator |
| Measurement Principle | Kjeldahl Method |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Variants | KDN-10D / KDN-15D / KDN-20D / KDN-15S / KDN-20S |
| Pricing | Upon Request |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Producer |
| Country of Origin | China |
| Model | LTJM-2099 |
| Quotation | Upon Request |
| Sample Capacity | 150–180 g |
| Dehulling Efficiency | ≥100% |
| Broken Kernel Rate | ≤5% for Japonica paddy, ≤10% for Indica paddy |
| Net Weight | 15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Motor Power | 850 W |
| Milling Time Range | 10–90 s (adjustable) |
| Time Display | Digital |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | MJ-IIA |
| Price | USD 1,080 (FOB) |
| Stirring Speed | 120 rpm ±2 rpm |
| Fine Washing Sieve | 80 µm (200 mesh) |
| Coarse Metal Sieve | 80 µm (26 mesh) |
| Washing Liquid Flow Rate | 50–56 mL/min |
| Kneading Time Range | 1–59 s (adjustable in 1-s increments) |
| Washing Time Range | 1–59 s or 1–9 min (dual digital display) |
| Centrifugation Time Range | 1–59 s or 1–9 min (dual digital display) |
| Centrifuge Speed | 3,000 rpm / 6,000 rpm ±5 rpm (selectable) |
| Centrifuge Sieve Box Aperture | 500 µm |
| Centrifugal Acceleration | 2,000 g |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MJ-IIA |
| Price | USD 1,100 (FOB) |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MJ-IIIA |
| Price | USD 1,750 (approx.) |
| Compliance | GB/T 5506–2008, SB/T 10248–1995 |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Wet Gluten Recovery Precision | ≤5% RSD between duplicate tests |
| Gluten Index Accuracy | ±11 units (index 70–100), ±15 units (index <70) |
| Washing Flow Rate | 50–56 mL/min |
| Stirring Speed | 120 rpm ±2 rpm |
| Fine Sieve | 80 µm (200 mesh) stainless steel |
| Coarse Sieve | 800 µm (26 mesh) stainless steel |
| Centrifugation Speeds | 3,000 rpm & 6,000 rpm ±5 rpm |
| Centrifuge Sieve Aperture | 500 µm (centrifuge basket), 600 µm (gluten index sieve) |
| Kneading Time Range | 1–59 s (1-s increments) |
| Washing Time Range | 1–59 s or 1–9 min (digital display) |
| Centrifugation Time Range | 1–59 s or 1–9 min (digital display) |
| Drying Temperature Range | 150–200 °C |
| Operating Humidity | <90% RH |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NY-12DG |
| Price | ¥38,000 |
| Detection Channels | 12 (spectrophotometric) + 3 (colloidal gold) |
| Display | 10.1-inch capacitive touchscreen |
| OS | Android-based embedded system |
| Wavelengths | 410 nm / 412 nm |
| Photometric Accuracy | ±2.0% transmittance |
| Photometric Repeatability | ≤0.2% |
| 3-Minute Stability | ≤0.2% |
| Data Storage | Internal + SD card expansion |
| Connectivity | Dual USB, Wi-Fi, Bluetooth, RJ45, optional 4G/5G & GPS/AGPS |
| Printing | Integrated thermal printer for test reports and peel-off traceability certificates |
| Compliance | Designed for alignment with GB/T 5009.199–2003, NY/T 448–2001, and ISO/IEC 17025 laboratory practice frameworks |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | NY-16DA |
| Detection Method | Enzyme Inhibition Assay |
| Measurement Range | 0–100% inhibition rate |
| Quantitative Range | 0–20 mg/kg |
| Number of Channels | 16 |
| Photometric Accuracy (Transmittance) | ≤ ±1.5% |
| Photometric Repeatability (Absorbance) | ≤ 0.005 A |
| Stability | ≤ 1.0% T drift (or ≤ 0.005 A) within 3 min after 20-min warm-up |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NY-1D |
| Price | USD 495 (approx.) |
| Measurement Error | ±5% |
| Transmittance Accuracy | ±3% |
| Transmittance Repeatability | ±2% |
| Linearity Error | ±5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 35–85% RH |
| Power Supply | Built-in 3.7 V Li-ion Battery + External 5 V DC Input |
| Display | Backlit Chinese LCD |
| Data Storage Capacity | 500 test records |
| Interface | USB 2.0 |
| Key Switches | Panasonic tactile membrane keys |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NY-1D |
| Price | USD 495 (approx.) |
| Photometric Accuracy (Transmittance) | ±3% |
| Photometric Repeatability (Transmittance) | ±2% |
| Linearity Error | ±5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 35–85% RH |
| Power Supply | Built-in 3.7 V Li-ion Battery + External 5 V DC Input |
| Data Storage Capacity | 500 Test Records |
| Interface | USB 2.0 |
| Display | Backlit Chinese LCD |
| Keypad | Panasonic Tactile Membrane Switches |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NY-8DA |
| Detection Method | Enzyme Inhibition Spectrophotometry |
| Measurement Range (Inhibition Rate) | 0–100% |
| Number of Channels | 8 |
| Measurement Error | ±10% |
| Quantitative Range | 0–20 mg/kg |
| Photometric Accuracy (Transmittance) | ≤±1.5% |
| Photometric Repeatability (Absorbance) | ≤0.005 A |
| Stability (3-min Drift after 20-min Warm-up) | ΔT ≤1.0% (or ΔA ≤0.005) |
| Brand | Top Cloud-agri |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NY-IC |
| Detection Principle | Competitive Gold Immunochromatographic Assay |
| Sample Types | Fresh tea leaves and dried tea (e.g., green tea, black tea, oolong tea, scented tea) |
| Number of Test Channels | 1 |
| Measurement Error | ≤3.5% |
| Limit of Detection (LOD) | 0.05 mg/kg in tea matrix |
| Semi-quantitative Range | <0.05 / 0.05–0.5 / >0.5 mg/kg |
| Sensitivity in Tea Infusion | 0.005 mg/L |
| Accuracy | ≥91.5% |
| False Positive Rate | <3.5% |
| False Negative Rate | <3.5% |