Gas Detector
Filter
Showing 841–870 of 2985 results
| Brand | Eranntex |
|---|---|
| Model | PTM600-HBr |
| Detection Principle | Electrochemical (standard), Optional IR/PID/TC/Catalytic Combustion |
| Detection Range | 0.001 ppm to 99.999 %Vol (auto-ranging, specified at order) |
| Resolution | 0.001 ppm (low-range), 0.001 %Vol (high-range) |
| Display | 3.5-inch HD color TFT screen |
| Protection Rating | IP66 |
| Ingress Protection | Dust-tight, powerful water jet resistant |
| Safety Certification | Intrinsically Safe (Ex ib IIB T4 Gb), CMC Certified |
| Sampling Method | Built-in explosion-proof diaphragm pump with integrated hydrophobic particulate filter |
| Sampling Distance | >10 m (with standard sampling hose) |
| Data Storage | Standard 100,000 records (expandable via SD card or USB mass storage) |
| Communication Interfaces | USB 2.0, RS232, Bluetooth 5.0 |
| Power Supply | 10,800 mAh Li-polymer battery (rechargeable via USB, supports hot-swap operation) |
| Operating Temperature | −40 °C to +70 °C (instrument) |
| Environmental Compensation | Integrated capacitive digital temperature/humidity sensor (optional) with real-time sensor compensation |
| Alarm Types | Dual-level (low/high), range, TWA, STEL |
| Calibration | Multi-point span calibration, zero auto-tracking, calibration log with timestamp and operator ID |
| Compliance | Meets GB/T 34004–2017, JJG 693–2011, ISO 16000-25, ASTM D6792, and supports 21 CFR Part 11 audit trail when used with compliant host software |
| Brand | Eranntex |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | PTM600-N2O |
| Detection Principle | Infrared (IR), Electrochemical (EC), PID, Catalytic Combustion, Thermal Conductivity |
| Detection Range (N₂O) | 0–100 ppm / 0–5000 ppm / 0–100% Vol (IR-based, selectable at order) |
| Resolution | 0.001 ppm (0–10 ppm), 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 0.001% Vol (0–99.999% Vol) |
| Accuracy | ≤±2% FS |
| Response Time (T90) | ≤20 s |
| Recovery Time | ≤30 s |
| Sampling Method | Integrated pump suction (800 mL/min) with particulate/moisture filter |
| Display | 3.5″ color TFT LCD (320×240) |
| Operating Temperature | −40°C to +70°C |
| IP Rating | IP66 |
| Explosion Protection | Exia II CT4 (Intrinsically Safe) |
| Battery | 3.7 VDC, 10800 mAh Li-polymer (rechargeable, with overcharge/overdischarge/short-circuit/thermal protection) |
| Data Storage | Standard 100,000 records |
| Communication | Bluetooth v5.0, USB, RS232 (auto-recognizing) |
| Certifications | CMC (China Metrology Accreditation), GB standard-compliant |
| Brand | Eranntex |
|---|---|
| Model | PTM600-NOX |
| Detection Principle | Electrochemical (standard for NOₓ), optional IR/PID/Catalytic Bead/Thermal Conductivity |
| Detection Range | 0–100 ppm (NOₓ, standard), extendable to 0–5000 ppm or 0–100% Vol |
| Resolution | 0.01 ppm (0–100 ppm), 0.1 ppm (0–1000 ppm), 1 ppm (>1000 ppm) |
| Accuracy | ≤±2% FS |
| Response Time (T90) | ≤20 s |
| Operating Temperature | −40 °C to +70 °C |
| IP Rating | IP66 |
| Intrinsic Safety Certification | Ex ia II C T4 |
| Battery | 10,800 mAh Li-polymer, continuous operation >12 h |
| Display | 3.5″ 320×240 color TFT LCD |
| Data Storage | 100,000 records (expandable via SD/UVC/USB) |
| Communication | Bluetooth v5.0, USB-C, RS232 |
| Pump Flow Rate | 800 mL/min |
| Weight | 2.5 kg |
| Dimensions | 255 × 210 × 125 mm (L×H×W) |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Model | Halo Sense |
| Monitoring Parameters | VOCs, Acid Gases, Formaldehyde |
| Environmental Operating Range | Temperature 10–30 °C, Relative Humidity 30–80 % RH |
| Power Consumption | 10 W |
| Electrical Supply | 100–240 V AC, 50–60 Hz |
| Sensor Technology | Semiconductor & Electrochemical Sensors (gas-specific) |
| Mounting Options | Benchtop or Wall-Mounted |
| Status Indication | Smart RGB Light Band |
| Data Acquisition | eGuard Software (PC & Mobile) |
| Compliance Context | Designed for GLP-aligned lab environments |
| Brand | Erlab |
|---|---|
| Origin | France |
| Model | Halo Sense |
| Detection Targets | VOCs, Acidic Gases, Formaldehyde |
| Sensor Types | Metal Oxide Semiconductor (VOC), Electrochemical (Acid & Formaldehyde) |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Power Consumption | 10 W |
| Enclosure Material | Lightweight, Durable Plastic |
| Mounting Options | Wall-mounted or Desktop |
| Weight | 1 kg |
| Compliance | CE, RoHS, EN 61000-6-3, EN 61000-6-1 |
| Software Platform | eGuard Cloud-Enabled Monitoring Suite |
| Data Connectivity | Ethernet (RJ45), Wi-Fi (optional), USB for local configuration |
| Alarm Output | Visual (RGB Status Light Band), Audible (85 dB @ 30 cm), Push Notifications via eGuard App |
| Brand | Erlab |
|---|---|
| Model | Halo Sense |
| Detection Targets | VOCs, Formaldehyde, Acidic Gases |
| Sensor Types | Semiconductor (VOCs), Electrochemical (Formaldehyde & Acidic Gases) |
| Mounting | Wall-mounted or Desktop |
| Power Supply | 100–240 V AC, 50–60 Hz |
| Power Consumption | 10 W |
| Enclosure Material | Impact-resistant polymer |
| Weight | 1 kg |
| Connectivity | Ethernet (LAN), USB (for local PC connection), Wi-Fi-enabled via eGuard software |
| Compliance | CE, RoHS, FCC Class B |
| Software Platform | eGuard v3.2+ (Windows/macOS/iOS/Android) |
| Data Logging | Local storage + cloud-synced (optional), audit-trail enabled |
| Alarm Output | Visual (RGB status ring with dynamic pulse pattern), Audible (adjustable 65–85 dB SPL), Relay contact (dry contact, 250 VAC/2 A) |
| Operating Temperature | 5–40 °C |
| Relative Humidity Range | 20–80 % RH (non-condensing) |
| Brand | Ersatec |
|---|---|
| Origin | Germany |
| Model | SmartFID |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Portable |
| Typical Configuration | Composite VOC Analyzer |
| Measurement Range | 0–100,000 ppm (as C₃H₈) |
| Resolution | 0.01 ppm |
| Accuracy | ±1.0% of reading |
| Response Time (T₉₀) | 1.5 s |
| Operating Temperature (Gas Path) | Up to 200 °C (optional to 230 °C) |
| Sample Flow Rate | 0.8–1.0 L/min |
| Power Supply | 115–230 VAC, 48–63 Hz, 120–150 W |
| Dimensions | 420 × 470 × 310 mm |
| Weight | 16 kg |
| Fuel Gas | H₂ (Grade 5, hydrocarbon residual <0.5 ppm, 3 bar) or H₂/He mixture |
| Zero Gas | Built-in catalytic hydrocarbon scrubber or carbon filter |
| Analog Outputs | Two user-configurable 0/4–20 mA |
| Digital Outputs | Three programmable relay contacts (250 V AC, 1 A) |
| Data Storage | Internal XML logging, USB export to Excel-compatible format |
| Brand | Ersatech |
|---|---|
| Model | SmartFID ST |
| Origin | Germany |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Online Analyzer |
| Configuration | Composite VOC Analyzer |
| Measurement Range | 0–100,000 ppm (as C₃H₈) |
| Resolution | 0.01 ppm |
| Accuracy | ±1.0% of reading |
| Response Time (T₉₀) | <1.5 s |
| Operating Temperature of Wetted Parts | 200 °C |
| Power Supply | 115–230 VAC, 48–63 Hz, max. 350 W |
| Dimensions | 177 × 445 × 365 mm (4U, 19″ rack-mountable) |
| Weight | 9 kg |
| Analog Outputs | Two user-configurable 0/4–20 mA |
| Digital Outputs | Three programmable relay contacts (250 V AC, 1 A) |
| Sample Flow Rate | ~1.2 L/min |
| Zero Drift | ≤0.5% of full scale per month |
| Span Drift | ≤2.8% of full scale per week |
| Linearity | ±1.0% of selected range |
| Oxygen Interference | <4% at 80 ppm C₃H₈ |
| Warm-up Time | 25 min |
| [Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | ESA-3 |
| Pricing | Available Upon Request |
| Flow Range Options | 0.1–3 L/min or 1–5 L/min |
| Power Supply | AC/DC Dual Mode with Optional Rechargeable Ni-MH Battery |
| Max Vacuum Pressure | ≥25 kPa |
| Rated Load Flow | ≥2.5 L/min |
| Flow Accuracy | Class 2.5 |
| Flow Stability | ≤±5% |
| Timer Accuracy | ≤±1% |
| Operating Temperature | –10 to 40 °C |
| Dimensions | 137 × 88 × 45 mm |
| Weight | <0.5 kg (incl. battery) |
| Compliance | Aligns with GBZ/T 192.2–2007 (Methods for Monitoring Hazardous Substances in Workplace Air), BMRC Inhalable Dust Separation Curve] |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ET5101 |
| Price Range | USD 7,000–14,000 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) Compliant Portable Analyzer |
| Indication Error | ±0.2% FS |
| Repeatability | <2% RSD |
| Response Time | ≤15 s (T90) |
| Stability | <5% drift over 8 h |
| Measured Parameters | Particulate Matter (PM) concentration via gravimetric filtration + Flue Gas composition (O₂, SO₂, NO, NO₂, CO, CO₂) |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 6080 EGAC |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 0.5 m³/h or 1.0 m³/h (critical orifice) |
| User Interface | 15" Color XGA + PCAP Touchscreen |
| Data Communication | Ethernet TCP/IP, USB 2.0 |
| Relative Humidity Range | 10–80 % RH (non-condensing) |
| Operating Temperature | 20–30 °C |
| Power Supply | 220 ± 22 VAC, 50 ± 0.5 Hz |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GC6010 |
| Pricing | Available Upon Request |
| Measurement Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Analytes | Non-Methane Hydrocarbons (NMHC), Benzene-Toluene-Ethylbenzene-Xylenes (BTEX) |
| Column Configuration | One Packed Column + One Empty Column (for THC) + One Dedicated Packed Column (for BTEX) |
| Detector | Dual FID Units (Dedicated or Shared via Valve Switching) |
| Oven Temperature Control | 120 °C (BTEX), 150 °C (NMHC), ±0.5 °C Stability |
| Carrier Gas | Hydrocarbon-Free Air |
| Analysis Cycle | < 120 s (NMHC), < 180 s (BTEX) |
| Response Time (T90) | < 20 s |
| Signal Output | RS-232 / RS-485 (Modbus RTU) |
| Power Supply | 220 ± 22 VAC, 50 ± 0.5 Hz |
| Operating Ambient | 0–50 °C |
| Sample Line Heating | Full High-Temperature Zone (≥150 °C), No Cold Spots |
| Valving | 5-Position, 10-Port Rotary Valve with Patented Back-Flush Capability |
| Compliance | GB/T 39786–2021, HJ 1012–2018, HJ 1078–2019 |
| Brand | ETI |
|---|---|
| Model | IES-200 |
| Origin | Guangdong, China |
| Instrument Type | Continuous Ambient Air Monitoring System |
| Measured Parameters | SO₂, CO, NO₂, O₃, TVOC, PM₁.₀, PM₂.₅, PM₁₀ |
| Detection Principle | Electrochemical (SO₂/CO/NO₂/O₃), PID (TVOC), Laser Scattering (PM) |
| Range | SO₂ 0–2 ppm |
| Resolution | SO₂ 0.05 ppm |
| Response Time (t₉₀) | SO₂/CO/NO₂/O₃ ≤90 s |
| Accuracy | ±5% of reading (gas) |
| Linearity Error | ±2% FS |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TiH200 |
| Pricing | Upon Request |
| Measurement Principle | Optical Colorimetry (Long-Path Liquid-Phase Absorption Spectrophotometry) |
| Measurement Range | 0–100 / 500 / 1000 / 5000 ppb (user-selectable full-scale ranges) |
| Resolution | 0.001 ppb |
| Repeatability | ≤2% RSD |
| Sampling Method | Integrated Diaphragm Pump |
| Response Time (t₉₀) | ≤150 s |
| Operating Temperature | 5–40 °C |
| Relative Humidity Range | 10–95% RH (non-condensing) |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TiH201 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Wet-Chemical Derivatization + Long-Path Optical Absorption (Indophenol Blue Method) |
| Compliance | Designed for continuous ambient air and industrial stack monitoring per EPA Method IO-5 (Ammonia by Indophenol Blue), ASTM D1426–22 (Standard Test Methods for Nitrogen in Water), and aligned with ISO 8573-1:2010 (for compressed air quality assessment where applicable) |
| Brand | ETI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TiH203 |
| Pricing | Available Upon Request |
| [Brand | East & West Analytical Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable PID Gas Analyzer |
| Detection Principle | Vacuum Ultraviolet (VUV) Photoionization |
| Configuration | Multi-compound VOC Analyzer |
| Compliance | Designed for field-deployable environmental and occupational safety monitoring] |
| Brand | EXPEC / Spectrometer Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Type | Online Fixed Installation |
| Model | EXPEC 1950 |
| Detection Principle | Open-Path Fourier Transform Infrared Spectroscopy |
| Detector | Stirling-Cooled MCT (Mercury Cadmium Telluride) |
| Measurement Range | ppb to % v/v (gas-dependent) |
| Optical Path Length | Adjustable (typically 10–500 m) |
| Spectral Resolution | ≤0.5 cm⁻¹ |
| Wavelength Range | 600–4000 cm⁻¹ (2.5–16.7 µm) |
| Data Output | Real-time qualitative & quantitative spectra, alarm-triggered reports, time-series concentration logs |
| Compliance | Designed for industrial environmental monitoring per ISO 14001, EPA Method 320, and ASTM D6348-19 guidance |
| Software | Embedded OP-FTIR analysis suite with spectral fingerprint library, auto-background correction, and neural network-based multicomponent deconvolution |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 2000 FT |
| Instrument Type | In-situ Extractive Hot-Wet CEMS |
| Measurement Principle | Fourier Transform Infrared (FTIR) Spectroscopy for Gaseous Pollutants & Moisture |
| Operating Temperature | Full-path 180 °C High-Temperature Heating |
| Spectral Resolution | Standard FTIR Configuration |
| Multi-component Capability | Simultaneous Quantification of ≥12 Gases |
| Compliance | Designed to Meet GB/T 16157, HJ 75–2017, HJ 76–2017, and EU EN 15267 / EN 14181 Requirements |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EXPEC 2000 |
| Pricing | Upon Request |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3500 Plus |
| Instrument Type | Portable |
| Detection Principle | Gas Chromatography–Mass Spectrometry (GC-MS) and Direct Electron Ionization Mass Spectrometry (EI-MS) |
| Configuration | Dual-Channel Integrated VOCs Analyzer |
| Compliance | Designed for field-deployable environmental monitoring per ISO 16000-6, ASTM D6196, and EPA Method TO-15/TO-17 frameworks |
| Sample Introduction | Real-time direct inlet + automated thermal desorption GC-MS module |
| Brand | EXPEC (Spectrum Technologies) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CEMS-2000 B FT |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Linearity Error | ≤ ±2% F.S. |
| Drift (Span) | ≤ ±2% F.S. / 7 days |
| Response Time | ≤ 180 s (with 50 m heated sampling line) |
| Zero Drift | ≤ ±2% F.S. / 7 days |
| Measured Gases | SO₂, NO, NO₂, NOₓ, NH₃, HCl, HF, CO, CO₂, O₂, H₂O |
| Brand | EXPEC (Pubetech) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Mobile Atmospheric Monitoring Vehicle |
| Pricing | Available Upon Request |
| Brand | EXPEC (Pubichem) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TRACE 8000 |
| Instrument Type | Online VOC Analyzer |
| Ion Source | Dual-Anode Hollow Cathode Lamp with H₂O Reagent Ion Chemistry |
| Mass Analyzer | Vertical-Entry Reflectron Time-of-Flight (TOF) |
| Detection Mode | Soft Chemical Ionization (PCI) via H₃O⁺ Transfer |
| Typical LOD | <100 pptv (sub-ppb) for C₂–C₁₀ VOCs |
| Operating Mode | Unattended Continuous Monitoring |
| Compliance Framework | Designed for ISO 16000-22, ASTM D6196-20, and EPA Method TO-15/TO-17 compatible workflows |
| Brand | SmartGas |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | YKC Series |
| Pricing | Upon Request |
| Output Options | Analog (4–20 mA / 0–10 V) and Digital (RS485 Modbus RTU, factory-configurable) |
| Maximum Stroke | 2540 mm (100 in) |
| Body Diameter × Length | 89 mm × 89 mm |
| Weight | 907 g |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FC-1A |
| Pricing | Available Upon Request |
| Flow Range | 3–30 L/min |
| Negative Pressure | >2500 Pa |
| Flowmeter Accuracy | Class 2.5 |
| Timer Range | 0–99 min (±0.1% error) |
| Battery Runtime | >3 h (Ni-Cd, 9.6 V / 4.5 Ah) |
| Operating Temp. | 0–40 °C |
| Relative Humidity | <95% RH |
| Power Consumption | <1.0 A |
| Dimensions (H×W×D) | 230 × 135 × 110 mm |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FC-4 |
| Pricing | Available Upon Request |
| Flow Range | 3–25 L/min (dual-channel, continuously adjustable) |
| Vacuum Pressure | >2500 Pa |
| Flowmeter Accuracy | Class 2.5 |
| Timer Range | 0–99 min (timing error ≤0.1%) |
| Battery Runtime | >3 hours (continuous operation) |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <95% RH |
| Power Supply | 9.6 V / 4.5 Ah Ni-Cd rechargeable battery |
| Operating Current | <1.2 A |
| Dimensions (H×W×D) | 230 × 140 × 140 mm |
| Standard Kit Includes | 1× main unit, 2× sampling heads, 2× filter cassettes, 2× boxes of standard 37-mm or 25-mm membrane filters (e.g., PVC, mixed cellulose ester), 1× AC adapter cable, 1× tripod mount, 1× user manual, 1× certificate of conformity, 1× aluminum carrying case |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FCC-25 |
| Pricing | Upon Request |
| Sampling Flow Rate | 20 L/min |
| Maximum Vacuum Pressure | >3000 Pa |
| Load Capacity | ≥1000 Pa |
| Dust Fraction Collection | Total Dust & Respirable Dust |
| Timer Range | 0–99 min (adjustable) |
| Continuous Operation Time | >120 min |
| Sound Pressure Level | ≤70 dB(A) |
| Explosion Protection | Intrinsic Safety ibI (150 °C) |
| Operating Temperature | −5 to 35 °C |
| Relative Humidity Limit | ≤95% RH |
| Dimensions | 200 × 140 × 80 mm |
| Housing Material | Reinforced ABS with Anti-Moisture, Anti-Dust & Anti-Static Treatment |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FCC-3000G |
| Pricing | Available Upon Request |
| Sampling Flow Rate | 2 L/min |
| Vacuum Pressure | >5000 Pa |
| Load Capacity | >2000 Pa |
| Dust Fraction Collection | Total Dust & Respirable Dust |
| Continuous Operation Time | >10 h |
| Sound Pressure Level | <60 dB(A) |
| Explosion Protection | Intrinsic Safety, Exib I |
| Operating Temperature | 0–35 °C |
| Relative Humidity | <95% RH |
| Dimensions (L×W×H) | 120 × 80 × 42 mm |
| Weight | 450 g |
| Power Supply | 5× Ni-MH rechargeable cells (1.3 Ah each), series-connected |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FCS-10 |
| Price Range | USD 280 – 700 |
| Power Supply | DC 11.1 V (4.5 Ah Li-ion battery) / AC 220 V ±10%, 50 Hz |
| Flow Range | 1–10 L/min or 1–15 L/min (selectable) |
| Vacuum Pressure | >1500 Pa |
| Flowmeter Accuracy | ±2.5% F.S. |
| Flow Stability | ≤±5% |
| Sampling Flow Error | ≤±5% |
| Noise Level | <75 dB(A) |
| Timer Range | 1 min – 99 h 59 min |
| Timer Accuracy | ≤±0.1% |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | <95% RH |
| Charging Current | 1 A |
| Continuous Operation Time | >5 h |
| Dimensions | 205 × 135 × 115 mm |
| Weight | 2.3 kg |