| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | <1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Detectable Particle Sizes | 0.3, 0.5, 5.0 µm (Model 3888) |
| Maximum Concentration | 2,000,000 particles/ft³ |
| Sampling Duration | 6 sec–99 min 59 sec |
| Count Alarm Range | 1–9,999,999 |
| Compliance | ISO 21501-4, JIS B 9921, GB/T 16292-2010, Annex 1 of EU GMP, FDA Guidance for Aseptic Processing |
| Data Storage | 10,000 records (CSV format) |
| Communication | USB (Host & Device), RS485, Ethernet, Wi-Fi |
| Power | Dual 3.7 V / 2600 mAh rechargeable Li-ion batteries or AC adapter (100–240 V) |
| Battery Life | Up to 5 h (single-test mode) |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Dimensions | 100 × 213 × 55 mm (W × H × D) |
| Weight | 650 g (body only, excluding batteries) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3888 / 3889 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3888 / 3889 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | <1 particle per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | ≤±30% FS |
| Particle Size Channels | 0.3, 0.5, 5.0 µm (3888) |
| Max Concentration | 2,000,000 particles/ft³ |
| Sampling Duration | 6 sec – 99 min 59 sec |
| Data Storage | 10,000 records (CSV) |
| Communication | Dual USB (Host/Device), RS485, Ethernet, WiFi |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Power | Rechargeable Li-ion battery (3.7 V, 2600 mAh), AC adapter (100–240 V) |
| Battery Life | ~5 h (single-test mode) |
| Dimensions | 100 × 213 × 55 mm (W × H × D) |
| Weight | 650 g (body only, no battery) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3905 |
| Flow Rate | 28.3 L/min |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% ±20% at 0.3 µm (ISO 21501-4 compliant) |
| Repeatability | ≤±10% FS |
| Size Resolution | <15% at 0.3 µm (ISO 21501-4) |
| Maximum Concentration | 500,000 particles/ft³ |
| Sampling Time Range | 6 sec – 23 h 59 min 59 sec |
| Data Storage | 10,000 sample records (internal), USB-expandable |
| Display | 6.4-inch full-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, FDA 21 CFR Part 11 (audit trail enabled), EU GMP Annex 1, JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3905 |
| Flow Rate | 28.3 L/min |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (simultaneous) |
| Counting Efficiency | 50 ± 20% @ 0.3 µm (ISO 21501-4 compliant) |
| Maximum Concentration | 500,000 particles/ft³ |
| Size Resolution | <15% @ 0.3 µm (ISO 21501-4) |
| Display | 6.4-inch full-color touchscreen |
| Data Storage | 10,000 measurement records (internal), USB-expandable |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, USP <788>, FDA 21 CFR Part 11 (audit trail enabled), EC GMP Annex 1, JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3910 |
| Flow Rate | 50 L/min |
| Flow Accuracy | <1 particle/5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | <±30% FS |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (simultaneous) |
| Counting Efficiency | 50±20% @ 0.3 µm (ISO 21501-4 compliant) |
| Max Concentration | 300,000 particles/ft³ |
| Size Resolution | <15% @ 0.5 µm (ISO 21501-4) |
| Zero Count | JIS-compliant |
| Data Storage | 10,000 sample records (expandable via USB drive) |
| Display | 6.4-inch true-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, GB 50333–2013, EU GMP Annex 1, USP <788>, FDA 21 CFR Part 11 (audit trail enabled), JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3910 |
| Flow Rate | 50 L/min |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | 50 ± 20% @ 0.3 µm (ISO 21501-4 compliant) |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Timing Accuracy | ±1 s per 6-min sampling |
| Flow Accuracy | <1 particle deviation per 5 min |
| Data Storage | 10,000 sample records (expandable via USB drive) |
| Display | 6.4-inch true-color touchscreen |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, GB/T 16292–2010, JJF 1190–2008, EU GMP Annex 1, US FDA 21 CFR Part 11 (audit trail enabled), JIS B 9921 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3920 |
| Flow Rate | 100 L/min |
| Simultaneous Channel Count | 6 |
| Detectable Particle Sizes | 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm |
| Compliance | ISO 14644-1, ISO 21501-4, USP <788>, FDA 21 CFR Part 11, GMP (2010), GB/T 16292–2010, EC GMP, British Standard BS EN ISO 14644 |
| Data Storage Capacity | 10,000 measurement records with geotagging (map coding) |
| Display | 6.4-inch full-color touchscreen |
| Power | Rechargeable Li-ion battery (dual-slot), AC 100–240 V |
| Weight | ~4.5 kg (without battery), ~5.0 kg (with battery) |
| Dimensions | 200 × 205 × 250 mm |
| Communication | USB, Ethernet, optional environmental sensor interface |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3920 |
| Flow Rate | 100 L/min |
| Particle Size Channels | 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (simultaneous) |
| Counting Efficiency | ≥50% ±20% at 0.5 µm (ISO 21501-4 compliant) |
| Maximum Concentration | 300,000 particles/ft³ |
| Repeatability | ≤±10% FS |
| Size Resolution | <15% at 0.5 µm (ISO 21501-4) |
| Flow Accuracy | <1 particle deviation per 5 min |
| Timing Accuracy | <±30% FS |
| Indication Error | <±30% FS |
| Data Storage | 10,000 measurement sets with geotagging (map coding) |
| Compliance | ISO 14644-1:2015, ISO 14644-2015, EU GMP Annex 1, USP <788>, FDA 21 CFR Part 11 (audit trail & electronic signature support), GB/T 16292–2010, GB 50333–2013, BS 5295, Federal Standard 209E |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3920 |
| Flow Rate | 100 L/min |
| Particle Size Channels | 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% ±20% at 0.5 µm (ISO 21501-4 compliant) |
| Maximum Concentration | 300,000 particles/ft³ |
| Repeatability | ≤±10% FS |
| Flow Accuracy | <1 particle deviation per 5 min |
| Timing Accuracy | <±30% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | <±30% FS |
| Data Storage | 10,000 measurement sets with geotagging (map coding) |
| Compliance | ISO 14644-1:2015, ISO 14644-2:2015, EU GMP Annex 1, USP <788>, FDA 21 CFR Part 11 (audit trail & electronic signature support), GB/T 16292–2010, GB 50333–2013, British Standard BS EN ISO 14644, Federal Standard 209E (repealed but referenced) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 µm, 0.3 µm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" Color Touchscreen LCD |
| Communication | RS-485, Ethernet, USB (Host/Device) |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1 CFM) |
| Particle Size Channels | 0.3 & 0.5 μm (3718-A) / 0.5 & 5.0 μm (3719-A) |
| Light Source | Long-life Laser Diode |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14644-1:2015 |
| Data Storage | 2,000 Sample Records with Redundant Backup |
| Output Interfaces | RS485, Modbus RTU/TCP/IP, 4–20 mA Analog Output |
| Power Supply | DC 9–28 V, PoE, or AC 100–240 V |
| Enclosure Material | 316 Stainless Steel with VHP/Alcohol-Vapor Resistant Sealing |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 133 × 95 × 80 mm |
| Weight | 1.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 3720-06 |
| Pricing | Available Upon Request |
| Particle Size Channels | Selectable 2–4 channels from 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (standard configuration: 0.5 & 5.0 µm) |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 1,000,000 particles/ft³ |
| Data Storage | 5,000 measurement records (2,000 in volatile buffer with redundancy) |
| Housing Material | 316 stainless steel with VHP- and ethanol vapor-resistant sealed enclosure |
| Vacuum Sampling Pump | Removable and serviceable |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Communication Interfaces | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Alarm Output | Configurable 0–100% threshold, relay ON/OFF |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −10–50 °C, ≤95% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | 3720-06 |
| Instrument Type | Online Particle Counter |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Detectable Particle Sizes | 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (user-selectable 2–4 channels, factory-configured) |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Max. Concentration | 1,000,000 particles/ft³ |
| Data Storage | 5,000 records (2,000-record buffer + redundancy backup) |
| Enclosure Material | 316 stainless steel with VHP- and ethanol vapor-resistant sealing |
| Vacuum Sampling Pump | Removable and serviceable |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Communication | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SDM-II |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Detection Principle | Laser Scattering (90° Forward Light Scattering) |
| Safety Rating | Non-Explosive |
| Communication Interface | RS485 |
| Zero & Span Auto-Calibration | Yes |
| Alarm Threshold Setting | Yes |
| Built-in Dehumidification | Yes |
| Filter Membrane Sampling Module | Included |
| Compliance | ISO 12103-1 A2 Fine Test Dust Compatible, Meets JIS B 7960 for Optical Dust Monitors |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SDM-II |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | PM2.5, PM10, TSP |
| Measurement Range | 0.001–30.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Zero & Span Auto-Calibration | Yes |
| Alarm Threshold Setting | Yes |
| Automatic Dehumidification | Yes |
| Communication Interface | RS485 |
| Power Supply | DC 10–15 V, 2 A |
| Dimensions (w/o case) | 250 × 350 × 170 mm |
| Weight (w/o case) | ~4.5 kg |
| Weight (with case) | ~8 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | SDM-II+ |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | PM2.5, PM10, TSP |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Sampling Flow Rate | 1.7 L/min |
| Zero & Span Auto-Calibration | Yes |
| Humidity Compensation | Integrated Automatic Dehumidification |
| Alarm Threshold Setting | Configurable Concentration Limit |
| Communication Interface | RS485 |
| Power Supply | DC 10–15 V, 2 A |
| Dimensions (W×H×D) | 250 × 350 × 170 mm (unit only) |
| Weight | ~4.5 kg (unit only) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Kanomax SXYC-508 |
| Operating Principle | Optical Scattering (β-ray attenuation & integrated gravimetric verification) |
| Safety Rating | Non-explosion-proof |
| Dust Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Noise Range | 30–130 dB(A) |
| Noise Accuracy | ±0.5 dB |
| Atmospheric Pressure Range | 10–1100 hPa |
| Pressure Accuracy | ±0.3 hPa |
| Wind Speed Range | 0.00–70.0 m/s |
| Wind Speed Accuracy | ±0.03 m/s |
| Wind Direction Range | 0–360° |
| Direction Accuracy | ±0.5° |
| Temperature Range | −50–100°C |
| Humidity Range | 0–100% RH |
| Temp/Humidity Accuracy | ±0.5°C / ±3% RH |
| Power Consumption | 30 W |
| Power Supply | AC 220 V ±10% with backup battery (≥6 h runtime) |
| Data Protocol Compliance | HJ/T 212–2005 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | SXYC-508 |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Safety Classification | Non-explosion-proof |
| Compliance Standard | HJ/T 212–2005 |
| Detection Principle | Beta-ray attenuation (integrated gravimetric reference via filter sampling) |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC2002 |
| Detection Targets | Trace Impurity Analysis in High-Purity Gases (He, H₂, N₂, CO₂, etc.) |
| Temperature Control Precision | ±0.01 °C |
| EPC/EFC Pressure Accuracy | 0.001 psi |
| EPC/EFC Flow Accuracy | 0.001 mL/min |
| Column Oven Cooling Time | ≤5 min (350 °C → 50 °C) |
| Max Programmed Temperature Ramps | 16 stages (extendable to unlimited) |
| Detector Options | TCD, FID, ECD, FPD |
| Data Interface | RJ45 Ethernet (TCP/IP), Embedded Chromatography Workstation |
| Remote Control Capacity | Up to 253 units per workstation |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | GC9800 (N₂/CO₂/THC Configuration) |
| Detection Targets | Trace Impurities in High-Purity Gases (He, H₂, N₂, CO₂, CH₄, CO, O₂, Total Hydrocarbons) |
| Detectors | TCD (TC-1H) + FID + Ni Catalyst Methanizer |
| Temperature Range | 8 °C above ambient to 400 °C |
| Temperature Control Accuracy | ±0.5% |
| Max. Programmed Ramps | 8 steps |
| Ramp Rate | 0–39 °C/min (0.1 °C/min increment) |
| TCD LOD | H₂ ≤ 0.5 ppm, O₂ ≤ 1 ppm, N₂ ≤ 3 ppm |
| FID LOD | CO 0.1–0.2 ppm, THC ≤ 2 ppm (Ar carrier) |
| Linear Range | FID 10⁷, TCD 10⁵ |
| Baseline Noise | FID ≤ 1×10⁻¹³ A, TCD ≤ 10 µV |
| Baseline Drift | FID ≤ 5×10⁻¹³ A/30 min, TCD ≤ 60 µV/30 min |
| Stabilization Time | FID ≤ 1 h, TCD ≤ 2 h |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | GC9800 High-Purity Gas Analyzer |
| Detection Targets | Trace impurity analysis in high-purity gases (He, H₂, N₂, CO₂, CH₄, O₂, CO, NH₃, Ar, etc.) |
| Detector | TC-1H Thermal Conductivity Detector (TCD) |
| TCD Sensitivity | ≥5000–10000 mV·mL/mg (benzene) |
| Baseline Noise | ≤0.01 mV |
| Baseline Drift | ≤0.1 mV/30 min |
| Linear Range | 10⁵ |
| Oven Temperature Range | 8°C above ambient to 400°C |
| Temperature Control Accuracy | ±0.5% |
| Programmable Temperature Ramping | 8-step |
| Ramp Rate | 0–39°C/min (0.1°C/min increment) |
| Ramp Reproducibility | ≤1% |
| Communication Interface | 10/100M Ethernet |
| Remote Control Capacity | Up to 253 units per workstation |
| Column Oven | Large-volume oven with automatic rear-door opening |
| Near-Ambient Operation | Enabled down to ambient +8°C |
| Self-Diagnostic System | Real-time fault localization and type identification |
| Over-Temperature Protection | Independent thermal cutoff for all six temperature zones |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GC9800 (N/SF₆/FPD) |
| Detection Targets | HCl, SiH₄, CF₄, SO₂F₂, S₂OF₂, S₂OF₁₀ (ppm-level trace impurities in ultra-high-purity SF₆) |
| FPD Sensitivity | ≤5.0×10⁻¹¹ g/s (n-hexadecane) |
| Baseline Noise | ≤0.1 mV |
| Baseline Drift | ≤0.5 mV / 0.5 h |
| Oven Temp Range | 8 °C above ambient to 400 °C |
| Temperature Control Accuracy | ±0.5% |
| Programmable Temperature Steps | 8 |
| Ramp Rate | 0–39 °C/min (0.1 °C/min increment) |
| Retention Time Reproducibility | ≤1% RSD |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GC9800N/TFH |
| Detection Targets | Trace impurities in high-purity helium (Ne, O₂, N₂, H₂, CO₂, CH₄), hydrogen, nitrogen, and carbon dioxide |
| Detectors | TCD (TC-1H) + FID + Ni methanizer |
| Minimum Detectable Concentration | Ne: 0.18 ppb v/v, O₂: 0.09 ppb v/v, N₂: 0.08 ppb v/v |
| Temperature Range | 8 °C above ambient to 400 °C |
| Temperature Control Accuracy | ±0.5% |
| Programmable Temperature Ramping | 8-step, 0–39 °C/min (0.1 °C/min increment) |
| Baseline Noise | ≤0.01 mV |
| Baseline Drift | ≤0.1 mV/30 min |
| Linear Range | 10⁵ |
| Column Oven | Motorized auto-back-opening, near-ambient operation (≥8 °C above ambient) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HG-37N |
| Price Range | USD 68,000 – 136,000 (FOB Japan) |
| Measurement Principle | Cold Vapor Atomic Absorption Spectroscopy (CVAAS) with Dry Oxidation-Reduction Conversion |
| Measurement Range | 0–50 µg/m³N or 0–1000 µg/m³N (switchable) |
| Response Time | ≤90 s |
| Repeatability | ±1% of reading |
| Linearity Error | ±2% of full scale |
| Zero Drift | ≤±1% per week |
| Sample Gas Flow Rate | 300 mL/min |
| Calibration Interval | Recommended every 30 days |
| Interference Resistance | Immune to Cl⁻, SO₂, NOₓ, H₂O vapor, and particulate carryover under ISO 15202-compliant sampling conditions |
| Compliance | Designed to meet EPA Method 29, ASTM D6784-22, and EN 14181 QAL1 requirements for mercury CEMS |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | KHC-2000B |
| Price | USD 860 (FOB) |
| Brand | Meiko Rika |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Needle EX |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Rate Range | 2 L/min |
| Maximum Vacuum Pressure | 0.5 bar |
| Flow Stability | <5% |
| Flowmeter Accuracy | ±2% |
| Service Life at Max Flow & Backpressure | >5,000 hours |
| Reusability | 25–30 cycles after thermal desorption |
| Compatible Manual Pumps | AP-20N, AP-20B (KITAGAWA) |
| Sample Volumes | 10 mL, 50 mL, 100 mL |
| Target Analytes | VOCs (e.g., ethanol, ethyl acetate, isopropanol, toluene, xylene), trimethylamine, short-chain fatty acids (propionic, isobutyric, n-butyric, isovaleric acid), and other trace organic vapors |
| Brand | Kōmyō Rikka (Komyo Rikka) |
|---|---|
| Origin | Japan |
| Model | AP-20N |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Rate Range | 2 L/min |
| Sample Volume Settings | 10 mL, 50 mL, 100 mL |
| Construction Material | Blue Antimicrobial Polymer Housing |
| Compatible With | GC Needle Extractors (e.g., Needle EX series) |
| Suitable For | Volatile Organic Compounds (VOCs) including gasoline vapors, kerosene fumes, fatty acids, floral volatiles, and organic solvents |
| Brand | Ko-mei Rikagaku |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 131 |
| Pricing | Upon Request |
| Brand | Koemco |
|---|---|
| Origin | Japan |
| Model | DSP-550T |
| Instrument Type | General-Purpose Gas Sampler |
| Configuration | Single-Channel Sampling Pump |
| Flow Range | 50–550 mL/min |
| Maximum Vacuum Pressure | 5,000 Pa |
| Flow Stability | ±10 mL/min |
| Flowmeter Accuracy | ±10 mL/min |
| Service Life at Max Flow & Backpressure | 10,000 hours |
| Continuous Operation Duration at Max Flow & Backpressure | 12 hours |
| Power Source | 4× AA Alkaline or Ni-MH (2000 mAh) |
| Runtime (Alkaline) | ~11 h @ 300 mL/min, ~6 h @ 500 mL/min |
| Runtime (Ni-MH) | ~15 h @ 300 mL/min, ~12 h @ 500 mL/min |