| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Piezoelectric Microbalance (QCM) |
| Particle Size Range | 0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5) |
| Concentration Range | 0.01–10.00 mg/m³ |
| Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Sampling Duration | Fixed modes (24 s, 120 s) or user-defined (10–3600 s) |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery / AC adapter (100–240 V AC) |
| Battery Life | ~4.5 h continuous operation |
| Charging Time | 5–8 h |
| Dimensions (W×L×H) | 65 × 182 × 150 mm |
| Weight | ~1.75 kg |
| Auto-Cleaning Alert | Yes (triggered upon crystal mass loading threshold exceedance) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Operating Principle | Tapered Element Oscillating Microbalance (TEOM™-style piezoelectric resonant frequency shift) |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤±2% |
| Particle Size Range | 0.1–10 µm (PM₁₀ mode) |
| Sample Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery or AC adapter (100–240 V AC) |
| Battery Life | ~4.5 hours continuous operation |
| Charging Time | 5–8 hours |
| Dimensions | 65 × 182 × 150 mm (W × L × H) |
| Weight | ~1.75 kg |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for occupational hygiene and environmental monitoring per ISO 7708, ISO/IEC 17025-aligned operational practices, and compatible with OSHA/NIOSH PM sampling protocols |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Piezoelectric Microbalance (PMB) |
| Particle Size Range | 0.1–10 µm (PM10), 0.1–2.5 µm (PM2.5) |
| Measurement Range | 0.01–10.00 mg/m³ |
| Sampling Flow Rate | 1.0 L/min |
| Data Storage Capacity | 500 measurement records |
| Communication Interface | RS-232C |
| Power Supply | Rechargeable Ni-MH battery / AC adapter (100–240 V AC) |
| Operating Time | ~4.5 h (fully charged) |
| Charging Time | 5–8 h |
| Dimensions | 65 × 182 × 150 mm (W × L × H) |
| Weight | ~1.75 kg |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for indoor/outdoor ambient air monitoring per ISO 7708, EN 481, and JIS Z 8901 dust classification frameworks |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KD11 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™-style piezoelectric resonant frequency shift) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C |
| Configurable Sampling Interval | 10–3600 seconds (preset options: 24 s, 120 s) |
| Cleaning Alert | Auto-notification upon crystal mass loading threshold exceedance |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | KD11 |
| Operating Principle | Tapered Element Oscillating Microbalance (TEOM™-style microgravimetric method) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0.01–10.00 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C |
| Sampling Duration Options | Fixed modes (24 s, 120 s) or user-defined (10–3600 s) |
| Maintenance Alert | Automatic crystal contamination warning |
| Brand | KANOMAX |
|---|---|
| Origin | China (Liaoning) |
| Model | 3000-0C+ |
| Instrument Type | Online Fit Testing System |
| Flow Rate | Sampling Flow 100 cm³/min |
| Particle Size Range | 0.02–1.0 µm |
| Concentration Range | 0–100,000 particles/cm³ |
| Fit Factor Calculation Method | Direct Cout/Cin Ratio |
| Test Agent | Isopropanol or Ethanol (≥99.5% purity) |
| Display | 7-inch TFT color touchscreen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Data Interface | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Report Format | Microsoft Excel (.xlsx) |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −20–50 °C, 0–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W×H×D) |
| Weight | 2.3 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Instrument Type | Aerosol-Based Quantitative Fit Tester |
| Particle Detection Method | Condensation Particle Counter (CPC) |
| Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Concentration Range | 0–100,000 particles/cm³ |
| Fit Factor Calculation | Direct Cout/Cin Ratio |
| Challenge Agent | ≥99.5% purity isopropanol or ethanol |
| Display | 7-inch full-color touchscreen |
| Languages | English, Japanese, Chinese, French, Spanish, Portuguese |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.1, HSE INDG479, GB 2626–2019, GB 19083–2010, GB/T 32610–2016 |
| Data Interface | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Report Output | Microsoft Excel format |
| Operating Environment | 10–35 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −20–50 °C, 0–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W×H×D) |
| Weight | 2.3 kg |
| Accessories Included | Isopropanol reagent kit, sealing cap, reagent rod, zero-count filter, mesh filter, sampling tube, user manual, AC adapter, stylus, USB cable, Ethernet cable, software DVD, USB flash drive |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Volume Range | 20–6000 L |
| Sampling Duration | Up to 7 h (battery operation) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 certified filter |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| User Management | 64 configurable users with multi-level permissions and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Volume Range | 20–6000 L |
| Sampling Time Range | Up to 7 h (battery operation) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 HEPA filter integrated |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV format) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Sample Support | 90–100 mm or 55–84 mm Petri dishes |
| User Management | 64 configurable users with multi-level permission control and audit trail |
| Remote Control | Infrared remote (supports up to 5 units simultaneously) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Sampling Principle | Andersen Impaction |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Sampling Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Cycle Count | 2–300 cycles or continuous |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Display | 4.3-inch color touchscreen |
| Communication | USB, RS-485 (Modbus RTU) |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Alarm | Visual & audible flow deviation alert |
| Exhaust Filtration | Integrated ISO Class 3 filter |
| Sampling Head Material | 316 stainless steel |
| Compatible Petri Dishes | 90–100 mm or 55–84 mm |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Sampling Principle | Andersen Impaction |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Volume Range | 20–6000 L |
| Sampling Duration | Up to 7 h on battery |
| Display | 4.3-inch color touchscreen |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| Impactor Stages | 6-stage Andersen design |
| Impact Velocity | <20 m/s |
| Exhaust Filtration | ISO Class 3 HEPA filter |
| Culture Dish Compatibility | 90–100 mm and 55–84 mm Petri dishes |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| User Management | 64 editable users with multi-level permissions and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Language Support | English, Japanese, Chinese |
| Alarm System | Visual & audible alerts for flow deviation, low battery, door open, filter saturation |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS485 (Modbus RTU) |
| Sample Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Power Supply | Li-ion rechargeable battery + AC adapter (100–240 V) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Battery Runtime | 7 h |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Sample Volume Range | 20–6000 L |
| Sampling Interval | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Power Supply | Li-ion rechargeable battery + AC 100–240 V adapter |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Duration | Up to 7 h (battery) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Volume Range | 20–6000 L |
| Time Interval Setting | 10 s–1 h |
| Delay Start | 0 s–23 h 59 min 59 s |
| Cycle Count | 2–300 cycles or continuous mode |
| Culture Dish Compatibility | 90–100 mm and 55–84 mm Petri dishes |
| Exhaust Filtration | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Time Range | 10 s to 1 h |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Principle | Andersen Impaction |
| Impactor Stages | 6-stage |
| Impact Velocity | <20 m/s |
| Sample Volume Range | 20–6000 L |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery (7 h runtime) + AC adapter (100–240 V) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Alarm | Visual & audible flow anomaly alert |
| Exhaust Filtration | Integrated ISO Class 3 filter |
| Sampling Head Material | 316 stainless steel |
| Language Support | English, Japanese, Chinese |
| Optional Accessories | Tripod, high-pressure gas sampling kit, thermal printer |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Flow Accuracy | ±2.5% |
| Sampling Volume Range | 20–6000 L |
| Timing Range | 10 s to 1 h (delay: 0 s to 23 h 59 min 59 s) |
| Sampling Cycles | 2–300 or continuous |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–90% RH (non-condensing) |
| Sampling Head Material | 316 Stainless Steel |
| Impactor Stages | 6-stage Andersen design |
| Impact Velocity | <20 m/s |
| Exhaust Filter Class | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power | Rechargeable Li-ion battery (7 h runtime) + AC adapter (100–240 V) |
| Dimensions | 136 × 235 × 133 mm |
| Weight | 3.2 kg |
| Language Support | English, Japanese, Chinese |
| User Management | 64 editable users with multi-level permission and audit trail |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 μm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1000 CPM / 0–1 V |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V (corresponding to 0–1,000 CPM or 0–10,000 CPM) |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Concentration Range | 0.001–10.000 mg/m³ |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V (corresponding to 0–1000 CPM or 0–10,000 CPM) |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V (corresponding to 0–1,000 CPM or 0–10,000 CPM) |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443+ |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1000 CPM / 0–1 V |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Laser Light Scattering |
| Particle Size Range | 0.1–10 μm |
| Measurement Range | 0.001–10.000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% |
| Relative Error | ≤±2% |
| Data Storage Capacity | 100,000 records |
| Communication Interface | USB |
| Analog Output | 0–1 V corresponding to 0–1000 CPM or 0–10,000 CPM |
| Dimensions | 162 mm (W) × 60 mm (D) × 109 mm (H) |
| Weight | Approx. 1.3 kg (including rechargeable battery) |
| Safety Classification | Non-explosion-proof |
| Compliance | Meets China’s Ministry of Health PM₁₀ monitoring requirements |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3443 |
| Measurement Principle | Optical Light Scattering (90° detection geometry) |
| Particle Size Range | 0.1–10 μm |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±10% of reading |
| Relative Error | ≤ ±2% |
| Sampling Duration | Programmable from 10 to 3600 seconds (preset modes: 24 s and 120 s) |
| Data Storage Capacity | 500 records |
| Communication Interface | RS-232C compliant |
| Safety Classification | Non-explosion-proof |
| Compliance | Designed for indoor/outdoor ambient air quality monitoring per ISO 17025-aligned laboratory practices and compatible with GLP data integrity workflows |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Max. Detectable Concentration | 2,000,000 counts/ft³ |
| Data Storage Capacity | 4,320 records |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Power Options | DC 12–24 V, AC 100–240 V, PoE, or DC battery |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85 %RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Internal Vacuum Pump Lifetime | 8,000 h |
| MTBF | ≥10 years |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3715-06D |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Light Source | Long-life laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B 9921 |
| Maximum Detectable Concentration | 2,000,000 counts/ft³ |
| Communication Protocols | RS-485, Modbus RTU/TCP/IP |
| Data Storage Capacity | 4,320 records |
| Power Supply Options | DC 12–24 V, AC 100–240 V, PoE, or external DC source |
| Operating Temperature | 10–30 °C |
| Operating Humidity | 20–85% RH (non-condensing) |
| Dimensions | 217 × 69 × 110 mm |
| Weight | 1.4 kg |
| Built-in Vacuum Pump Lifetime | 8,000 h |
| MTBF | ≥10 years |
| Display | 4.3-inch capacitive touchscreen |
| Status Indicators | Count, Flow, Laser, Alarm |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | 3720-06 |
| Price | Upon Request |
| Particle Size Channels | Selectable 2–4 from 0.3, 0.5, 0.7, 1.0, 3.0, 5.0, 10.0 µm (factory-configured |
| default | 0.5 & 5.0 µm) |
| Flow Rate | 28.3 L/min (1.0 CFM) |
| Light Source | Long-life Class II Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Detectable Concentration | 1,000,000 particles/ft³ |
| Data Storage | 5,000 full test records + 2,000 buffered measurements with redundancy backup |
| Housing Material | 316 Stainless Steel Enclosure with VHP- and ethanol vapor-resistant sealing |
| Vacuum Sampling Pump | Removable and serviceable |
| Power Supply | DC 15–28 V, PoE (IEEE 802.3af), or AC 100–240 V |
| Communication Interfaces | Ethernet (Modbus TCP/IP), RS-485 (Modbus RTU), 4–20 mA analog output |
| Alarm Output | Configurable ON/OFF per channel (0–100% threshold) |
| Operating Environment | 10–30 °C, 20–85% RH (non-condensing) |
| Storage Conditions | −10–50 °C, ≤95% RH (non-condensing) |
| Dimensions | 180 × 110 × 190 mm |
| Weight | 4.0 kg |
| MTBF | ≥10 years |
| Warranty | 3 years |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3887D |
| Instrument Type | Handheld Particle Counter |
| Sampling Flow Rate | 2.83 L/min (0.1 cfm) |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm |
| Data Storage Capacity | 7,000 records |
| Operating Interface | Chinese-language LCD display |
| Sampling Duration Range | 10 sec to 99 min 59 sec |
| Count Alarm Range | 1–70,000,000 particles per cubic foot |
| Power Supply | 4× AA Ni-MH rechargeable batteries (charger included) or AC adapter (100–240 V AC) |
| Dimensions | 108(W) × 68(D) × 196(H) mm |
| Weight | ~680 g (without batteries) |
| Compliance Standards | GB/T 16292–2010, ISO 14644-1:2015, China GMP (2010) Annex 1 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Detectable Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Count Range | 1–70,000,000 counts |
| Sampling Modes | Single, Repeat, Continuous, Calculate, Remote, GB/T 16292, ISO 14644-1 |
| Data Storage Capacity | 7,000 sample records |
| Power | Rechargeable Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3888, 3889, 3889-01 |
| Flow Rate | 2.83 L/min |
| Particle Size Channels | 0.3/0.5/5.0 µm (3888) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | < ±1 s over 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Size Distribution Error | ≤ ±30% |
| Indication Error | ≤ ±30% FS |
| Compliance | ISO 21501-4, JIS B9921, GB/T 16292–2010, Annex I of EU GMP Guidelines (2022), FDA Guidance for Aseptic Processing Environments |
| Data Storage | 10,000 sample records (CSV format) |
| Communication | Dual USB (Host/Device), RS485, Ethernet, Wi-Fi (via docking station) |
| Operating Temp. | 10–40 °C |
| RH | 0–85% non-condensing |
| Battery Life | Up to 5 h (single-test mode) |
| Weight | 650 g (body only, no battery) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3888 / 3889 |
| Sampling Flow Rate | 2.83 L/min |
| Detectable Particle Sizes | 0.3, 0.5, 5.0 µm (3888) or 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (3889) |
| Light Source | Laser Diode |
| Counting Efficiency | Compliant with ISO 21501-4 and JIS B9921 |
| Maximum Concentration | 2,000,000 particles/ft³ |
| Sampling Time Range | 6 sec – 99 min 59 sec |
| Sampling Modes | Single, Repeat, Continuous, Calculate, ISO, GB |
| Data Storage Capacity | 10,000 records (CSV format) |
| Communication Interfaces | Dual USB (Host/Device), RS485, Ethernet, WiFi |
| Operating Temperature | 10–40 °C |
| Relative Humidity | 0–85 % RH (non-condensing) |
| Dimensions | 100 × 213 × 55 mm (W × H × D) |
| Weight | 650 g (body only, battery excluded) |
| Battery Life | Up to 5 hours (single-test mode) |
| Language Support | English, Chinese, Japanese, Spanish |
| Regulatory Compliance | ISO 21501-4, JIS B9921, GB/T 16292–2010, Annex 1 of EU GMP, FDA Guidance for Aseptic Processing |