| Brand | Korno |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GT-1000-THT |
| Detection Principle | Electrochemical |
| Form Factor | Portable, Pump-Suction |
| Measurement Range | 0–20 ppm / 0–50 ppm / 0–100 ppm (selectable) |
| Resolution | 0.01 ppm (0–100 ppm range) |
| Accuracy | ≤ ±3% FS (dependent on sensor batch and calibration status) |
| Linearity Error | ≤ ±2% FS |
| Zero Drift | ≤ ±2% FS |
| Repeatability | ≤ ±2% FS |
| Response Time (T90) | ≤ 20 s |
| Recovery Time | ≤ 20 s |
| IP Rating | IP67 |
| Explosion Protection Certification | Ex ib IIB T4 Gb (Certificate No.: CLEx25.9119) |
| Conformity | GB/T 3836.1–2021 & GB/T 3836.4–2021 |
| Operating Temperature | –20 °C to +50 °C |
| Operating Humidity | ≤ 95% RH (non-condensing) |
| Power Supply | DC 3.7 V, 3800 mAh or 7200 mAh rechargeable polymer battery |
| Dimensions | 257 × 90 × 65 mm (L×W×H) |
| Weight | 0.5 kg (net) |
| Brand | Korno |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GT-903-SF6 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Detection Gas | Sulfur Hexafluoride (SF₆) |
| Measurement Range | 0–100 / 1000 / 2000 / 10,000 ppm |
| Resolution | 1 ppm (0–10,000 ppm) |
| Response Time (T90) | ≤20 s |
| Accuracy | ≤±3% FS |
| Linearity Error | ≤±2% FS |
| Zero Drift | ≤±2% FS |
| Recovery Time | ≤20 s |
| Sensor Expandability | Up to 4 optional gas sensors |
| Explosion Protection Certification | CLEx25.9118 (IECEx / ATEX-compliant design per GB/T 3836.1 & GB/T 3836.4–2021) |
| Ingress Protection | IP67 |
| Operating Temperature | −20 °C to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Pressure Range | 88–112 kPa |
| Battery | 3800 mAh rechargeable polymer lithium-ion |
| Charging | USB-C (compatible with PC, power bank, wall adapter) |
| Data Storage | 120,000 records (real-time or scheduled logging) |
| Calibration | Full software-controlled auto-calibration |
| Safety Features | Overvoltage protection, overcharge protection, ESD shielding, magnetic field immunity |
| Dimensions | 180 × 85 × 55 mm (L×W×H) |
| Weight | 0.5 kg (net) |
| Brand | Korno |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | GT-903-THT |
| Detection Principle | Electrochemical |
| Portability | Portable (Pump-Suction) |
| Measurement Range | 0.1–100 mg/m³ (configurable) |
| Sensitivity | Fast response |
| Accuracy | ≤±3% FS (sensor-dependent) |
| Response Time | ≤20 s (T90) |
| Resolution | 0.01 ppm (0–100 ppm range) |
| Linearity Error | ≤±2% FS |
| Zero Drift | ≤±1% FS |
| Recovery Time | ≤20 s |
| Sensor Capacity | Up to 4 interchangeable sensors |
| Repeatability | ≤±2% FS |
| Explosion Protection Certification | CLEx25.9118 |
| Ingress Protection | IP67 |
| Metrological Approval | 2017C125-44 |
| Operating Temperature | −20 to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Operating Pressure | 88–112 kPa |
| Battery | 3.7 V DC / 3800 mAh Li-polymer rechargeable |
| Display | 2.4″ industrial-grade color LCD |
| Data Storage | 30,800 × 4 groups (real-time/timed) |
| Connectivity | USB interface for data export |
| Optional Sensors | Temperature & humidity module (−20 to +50 °C / 0–100% RH) |
| Standards Compliance | GB/T 3836.1–2021, GB/T 3836.4–2021 |
| Brand | Korno |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | MOT500-CO2 |
| Detection Gas | CO₂ |
| Sensor Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Ranges | 0–500 / 1000 / 2000 / 5000 / 10,000 / 50,000 ppm |
| Resolution | 1 ppm (≤50,000 ppm), 0.01 %VOL (0–100 %VOL) |
| Response Time (T90) | ≤20 s |
| Accuracy | ≤±3% FS |
| Linearity Error | ≤±1% FS |
| Zero Drift | ≤±2% FS |
| Repeatability | ≤±1% FS |
| Explosion Protection Certification | CCRI24.8021X |
| IP Rating | IP66 |
| Operating Temperature | −20 to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Power Supply | 24 VDC (12–30 VDC) |
| Output Signals | 4–20 mA (16-bit), RS485 (Modbus RTU), 0–5 V / 0–10 V, 2× relay (NO/NC, 125 VAC/0.3 A, 30 VDC/1 A) |
| Installation Options | Wall-mount, pipe-mount (M40×1.5 mm thread), flow-through |
| Enclosure Material | Die-cast aluminum with sandblasted anodized or fluorocarbon coating |
| Dimensions (L×W×H) | 226 × 215 × 85 mm |
| Net Weight | 1.7 kg |
| Compliance Standards | GB/T 3836.1–2021, GB/T 3836.2–2021, GB/T 3836.31–2021 |
| Brand | Korno |
|---|---|
| Model | MOT500-He |
| Detection Gas | Helium (He) |
| Sensor Type | Imported Thermal Conductivity Sensor |
| Measurement Ranges | 0–10%, 0–50%, or 0–100% VOL |
| Resolution | 0.01% VOL |
| Response Time (T90) | ≤20 s |
| Accuracy | ≤±3% FS |
| Linearity Error | ≤±1% FS |
| Zero Drift | ≤±2% FS |
| Recovery Time | ≤20 s |
| Sensor Expansion | Up to 6 configurable gas sensors |
| Explosion Protection Certification | CCRI24.8021X |
| Ingress Protection | IP66 |
| Operating Temperature | −20 to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Power Supply | 24 VDC (12–30 VDC) |
| Output Signals | 4–20 mA (16-bit, 1 km), RS485 (MODBUS RTU, 2 km), 0–5 V / 0–10 V, 2× relay outputs (expandable to 3) |
| Installation Options | Wall-mount, threaded pipe mount (M40×1.5 mm), flow-through |
| Communication Options | Cable (3/4-core), TCP/IP (fiber/Ethernet), GPRS (optional), 433 MHz wireless (2–10 km, optional) |
| Housing | Die-cast aluminum with sandblasted oxidation/fluorocarbon coating |
| Dimensions & Weight | 226 × 215 × 85 mm (L×W×H), 1.7 kg (net) |
| Compliance | GB/T 3836.1–2021, GB/T 3836.2–2021, GB/T 3836.31–2021 |
| Brand | Korno |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | MOT500-SF6 |
| Instrument Type | Online Fixed-Mount Detector |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Measurement Range | 0–100 / 1000 / 2000 / 10000 ppm or 0–20% / 0–100% vol SF₆ |
| Resolution | 1 ppm (0–10000 ppm), 0.01% vol (0–100% vol) |
| Response Time (T90) | ≤20 s |
| Accuracy | ≤±3% FS |
| Linearity Error | ≤±1% FS |
| Zero Drift | ≤±2% FS |
| Recovery Time | ≤20 s |
| Sensor Expandability | Up to 6 gas channels (optional) |
| Repeatability | ≤±1% FS |
| Explosion Protection Certification | CCRI24.8021X (Ex d IIB T4 Gb / Ex tb IIIC T130°C Db) |
| Ingress Protection | IP66 |
| Operating Temperature | −20 to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Power Supply | 24 VDC (12–30 VDC) |
| Output Signals | 4–20 mA (16-bit), RS485 (Modbus RTU), 0–5 V / 0–10 V, 2× relay (expandable to 3) |
| Communication Options | Cable (≤2 km), TCP/IP (fiber/Ethernet), GPRS (optional), 433 MHz wireless (2–10 km) |
| Installation | Wall-mount, threaded pipe (M40×1.5 mm), flow-through |
| Enclosure Material | Die-cast aluminum with sandblasted anodized/fluorocarbon coating |
| Dimensions & Weight | 226 × 215 × 85 mm (L×W×H), 1.7 kg (net) |
| Compliance | GB/T 3836.1–2021, GB/T 3836.2–2021, GB/T 3836.31–2021 |
| Brand | Korno |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | MOT500-THT |
| Detection Principle | Electrochemical Sensor |
| Installation Type | Fixed |
| Measurement Range | 0–20 ppm / 0–50 ppm / 0–100 ppm (selectable) |
| Resolution | 0.01 ppm (for 0–100 ppm range) |
| Accuracy | ≤±3% FS (dependent on sensor batch and calibration) |
| Linearity Error | ≤±1% FS |
| Zero Drift | ≤±2% FS |
| Repeatability | ≤±1% FS |
| Response Time (T90) | ≤20 s |
| Recovery Time | ≤20 s |
| Enclosure Rating | IP66 |
| Explosion Protection Certification | CCRI24.8021X (compliant with GB/T 3836.1–2021, GB/T 3836.2–2021, GB/T 3836.31–2021) |
| Operating Temperature | −20 to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| Power Supply | 24 VDC (12–30 VDC) |
| Output Signals | 4–20 mA (16-bit precision, up to 1 km), RS485 (MODBUS RTU, up to 2 km), 0–5 V / 0–10 V analog, 2× SPDT relays (expandable to 3) |
| Communication Options | Cable (3/4-core), TCP/IP (fiber/Ethernet, optional), GPRS (optional), 433 MHz wireless (2–10 km, optional) |
| Mounting | Wall-mount, pipe-mount (M40×1.5 mm thread), flow-through configuration |
| Gas Sampling | Diffusion, flow-through, or pump-aspirated (configurable) |
| Sensor Expansion | Up to 6 electrochemical sensors (multi-gas capability) |
| Housing Material | Die-cast aluminum with sandblasted oxidation + fluorocarbon coating |
| Dimensions & Weight | 198 × 162 × 85 mm (L×W×H), 1.5 kg (net) |
| Brand | York Instrument |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | KULITE BG Series |
| Pricing | Upon Request |
| Brand | Labthink |
|---|---|
| Model | FT-F1 |
| Type | Benchtop Fogging Test Instrument |
| Standards Compliance | ISO 6452, DIN 75201, SAE J1756, QB/T 2728, BS EN 14288, PV 3920, PV 3015, ES-X83231, NES M0161, D45 1727, GM 9305P, TSM 0503G |
| Temperature Range (Hot Plate) | Ambient to 150 °C (optional up to 280 °C) |
| Temperature Control Accuracy | ±0.1 °C at 150 °C |
| Cold Plate Temperature Range | 0–100 °C |
| Cold Plate Control Accuracy | ±0.1 °C |
| Resolution | 0.1 °C |
| Accuracy | ±2% of reading |
| Response Time | <10 min |
| Measurement Methods | Gloss Loss Method (standard), Haze Method (optional), Gravimetric Method (standard, balance not included) |
| Sample Capacity | 6 parallel test positions |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (Hot Unit) | 670 × 490 × 540 mm (L×W×H) |
| Net Weight (Hot Unit, no heat transfer fluid) | 32 kg |
| Dimensions (Cold Unit) | 400 × 220 × 520 mm |
| Net Weight (Cold Unit, no coolant) | 15 kg |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Model | 4500 MkIII |
| Measurement Principle | Optical Light Scattering |
| Safety Classification | Non-Explosive Atmosphere Rated |
| Dust Concentration Range | 0–10 to 0–10,000 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1.5% of reading |
| Relative Error | ±1.5% |
| Compliance | ASTM D6216, EN 13284-2, EN 15267-3 QAL1 Certified |
| Brand | LAND |
|---|---|
| Origin | UK |
| Model | 4650-PM |
| Measurement Principle | Forward-Scatter Laser Light Scattering |
| Safety Rating | Non-Explosive |
| Measurement Range | 0–15 to 0–200 mg/m³ |
| Resolution | 0.01 mg/m³ |
| Accuracy | ±1% of reading |
| Relative Error | ≤1% |
| Operating Temperature | up to 500 °C (930 °F) |
| Compliance | U.S. EPA Performance Specification 11 (PS-11), applicable to MATS and Boiler MACT requirements |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lancom 4 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy (Full Scale) | ±2% |
| Repeatability | ±2% |
| Response Time (T90) | 60 s |
| Long-Term Stability (24 h) | ±2% |
| Measurable Gases | CO, O₂, NO, NO₂, CO₂, H₂S, SO₂, CₓHᵧ (up to 9 gases simultaneously) |
| Display | High-Resolution Color TFT Screen |
| Language Support | English, French, German, Italian, Spanish, Chinese (custom languages available on request) |
| Data Interface | USB 2.0 (PC connectivity & USB flash drive support) |
| Weight | 6 kg (13.2 lbs) |
| Compliance | ASTM D6522 (when used with integrated sample drying probe) |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | LJ-DCY |
| Price | USD 5,000 (FOB Qingdao) |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Atmospheric Heavy Metal Analyzer |
| Model | AOA 200 |
| Measurement Principle | X-ray Fluorescence (XRF) Spectrometry combined with β-ray Absorption and Automated Airborne Particulate Enrichment |
| Measurement Range | Heavy Metals: 0–100 µg/m³ |
| PM₂.₅/PM₁₀ Mass Concentration | 0–10 mg/m³ |
| Detection Limits | Heavy Metals: sub-ng/m³ level (1-hour sampling at 16.7 L/min) |
| Particulate Matter | <1 µg/m³ (24-hour average) |
| Filter Cartridge Lifetime | ~30 days under continuous hourly sampling mode |
| Operating Temperature | −40 °C to +50 °C |
| Operating Humidity | 0–90 %RH (non-condensing) |
| Ambient Pressure Range | 86–116 kPa |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | AOA 200CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Heated Extractive Sampling + Isokinetic Particulate Sampling + Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Target Analytes | Pb, Cr, Cd, As, Hg, Ni, Zn, Cu, Mn, Sb (as particulate-bound species) |
| Sampling Interval | Programmable (default 15 min) |
| Data Output Interfaces | RS232/RS485, USB, GPRS, ADSL, Ethernet |
| Radiation Safety | Fully Shielded ED-XRF Module with <0.1 µSv/h external dose rate |
| QC Protocol | Internal Standard Element Monitoring for Drift Correction |
| Compliance Framework | Designed to support EPA Method 29 / ISO 14956 / HJ 657–2013 / HJ 93–2013 alignment |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Atmospheric Heavy Metal Analyzer |
| Model | GaOA |
| Measurement Principle | X-ray Fluorescence (XRF) Spectrometry |
| Measurement Range | 0–100 µg/m³ |
| Detection Limit | 1 ng/m³ (1-hour sampling at 16.7 L/min) |
| Filter Tape Replacement Interval | One roll lasts ~30 days under hourly sampling |
| Operating Temperature | −40 °C to +50 °C |
| Operating Relative Humidity | 0–90% RH (non-condensing) |
| Ambient Pressure Range | 80–106 kPa |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Product Category | Atmospheric Heavy Metal & Sulfur Compound Online Analyzer |
| Model | SPAS |
| Price Range | USD 140,000 – 210,000 (FOB Jiangsu) |
| Compliance | CE-marked for industrial environmental monitoring |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MODEL3020 |
| Pricing | Available Upon Request |
| Measurement Principle | Laser Backscatter |
| Output Signal | 4–20 mA (max. load 500 Ω) |
| Power Supply | DC 16–24 V ±10% |
| Power Consumption | ≤3 W |
| Operating Temperature | −40 °C to +65 °C |
| Relative Humidity | 0–100 % RH |
| Max. Process Gas Temperature | 300 °C (custom high-temp option available) |
| Accuracy | ±2 % FS |
| Detection Limit | 2 mg/m³ |
| Measurement Range | 0–200 mg/m³ (standard), extendable to 0–10 g/m³ (configurable) |
| Flue Diameter Compatibility | 1–15 m |
| Flue Wall Thickness Limit | ≤400 mm |
| Optical Installation | Single-ended, alignment-free |
| Enclosure Dimensions | 160 × 160 × 250 mm |
| Weight | 4 kg |
| IP Rating | IP65 (with optional rain shield) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SootMaster |
| Instrument Type | Continuous Emission Monitoring System (CEMS) for Soot |
| Application Domain | In-situ, time-resolved soot volume fraction and primary particle size distribution imaging in combustion flows |
| Brand | LCTech |
|---|---|
| Origin | Germany |
| Model | DEXTech 16 |
| Weight | 280 kg |
| Compliance Standards | GB 5009.205–2013, GB 5009.190–2014, GB/T 28643–2012, HJ 77.1–2008, HJ 77.2–2008, HJ 77.3–2008, HJ 77.4–2008 |
| Brand | LCTech |
|---|---|
| Origin | Germany |
| Model | DEXTech Pure |
| Weight | 40 kg |
| Compliance | GB 5009.205–2013, GB 5009.190–2014, GB/T 28643–2012, HJ 77.1–2008, HJ 77.2–2008, HJ 77.3–2008, HJ 77.4–2008 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LD-3F |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | LD-5C |
| Price | ¥27,800 |
| Sampling Method | Real-time Laser Scattering with Optional Filter-Based Gravimetric Validation |
| Particle Size Selectivity | PM₁₀ / PM₅ / PM₂.₅ via Interchangeable Impactors |
| Concentration Range | LD-5C(L): 0.01–100 mg/m³ |
| LD-5C(H) | 0.001–10 mg/m³ |
| Detection Limit | LD-5C(L): 0.1 mg/m³ |
| LD-5C(H) | 0.001 mg/m³ |
| Display | Backlit LCD with Chinese Character Menu |
| Data Storage | 99 Cyclic Records |
| Sampling Duration | Configurable from 0.1 min to user-defined intervals (1–9999 s) |
| Communication Interfaces | RS232 Serial Port, Thermal Printer Output, 0–1 V Analog Output, Digital TTL-Level Output |
| Power Supply | Rechargeable Ni-MH Battery (8 h continuous operation), AC/DC Adapter Included |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | LD-5C(B) |
| Pricing | Available Upon Request |
| Measurement Principle | 90° Light Scattering (Laser Nephelometry) |
| Particle Size Cutpoints | PM₁₀, PM₅, PM₂.₅, TSP |
| Detection Sensitivity | 0.001 mg/m³ (high), 0.01 mg/m³ (low) |
| Accuracy | ±10% |
| Repeatability | ±2% |
| Measurement Range | 0.001–10 mg/m³ and 0.01–100 mg/m³ |
| Flow Control | Constant-Flow Pump (Adjustable, Certified for ISO/CEN/NIOSH Sampling Protocols) |
| Data Storage | 99 cyclic records (standard mode) |
| Sampling Duration | 0.1 min to 9,999 min (user-definable) |
| Alarm Threshold | Up to 65 mg/m³ (configurable) |
| Output Interfaces | RS232 serial port, analog output (0–1 V), digital TTL-level output, thermal printer port |
| Power Supply | Rechargeable Ni-MH battery pack (4 × 1.2 V), 8 h continuous operation |
| Weight | 2.4 kg |
| Compliance | GBZ1-2002, GBZ2-2002, WS/T206-2001, LD98-1996, TB/T2323-92, Hygiene Norms for HVAC Systems (MoH [2006] No.58) |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LDAR Management Platform |
| Pricing | Available Upon Request |
| Detection Principle | Software-Based Workflow Orchestration with Integration to Field Instruments (e.g., FID, PID, OGI) |
| Instrument Type | Cloud-Hosted SaaS Platform for Online Data Aggregation & Compliance Reporting |
| Typical Configuration | Web Portal + Mobile Application + API Integrations |
| Sampling Method | Instrument-Agnostic Data Ingestion (Manual Entry, Bluetooth/Wi-Fi Upload, CSV/API Import) |
| Detection Scope | Comprehensive LDAR Program Lifecycle Management (Leak Identification, Tagging, Scheduling, Repair Tracking, EPA/China MEP Compliance Reporting) |
| Resolution | Configurable by User-Defined Tag Hierarchy and Measurement Unit Mapping |
| Accuracy | Dependent on Connected Field Instrument Calibration & Data Entry Integrity |
| Response Time | Real-Time Dashboard Updates (Sub-Second UI Refresh |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Model | 3800Plus |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Compliance | HJ 1012–2018 |
| Power Supply | Integrated rechargeable battery + external DC/AC input |
| Dimensions (incl. internal gas cylinders & battery) | ≤ 420 × 320 × 180 mm |
| Weight | < 12.5 kg |
| Sample Inlet | Built-in diaphragm pump with flow control |
| Column Configuration | Dual-capillary column system with backflush capability |
| Detection Range | Methane (0.1–10,000 ppm), NMHC (0.05–10,000 ppm as propane), BTEX (0.1–500 ppb to ppm, compound-dependent) |
| Analysis Cycle Time | 60–180 s per sample (configurable) |
| Brand | Leshi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | 9100 ODS |
| Price Range | USD 365,000 – 408,000 |
| Measurement Principle | Fourier Transform Infrared Spectroscopy (FTIR) |
| Application Domain | Environmental Compliance & Industrial Emissions Monitoring |
| Detection Principle | FTIR Absorption Spectroscopy |
| Accuracy | ≤ ±2% of Full Scale |
| Target Gases | 30 Primary ODS Compounds (e.g., CFC-11, CFC-12, HCFC-22, HCFC-141b, Halon-1211, Halon-1301, CCl₄, CH₃Br, etc.) |
| Response Time | ≤ 120 s |
| Repeatability | < 2% of Full Scale |