Gas Detector
Filter
Showing 1711–1740 of 3002 results
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Resolution | ≤15% (vs. 0.3 µm PSL) |
| Counting Efficiency | 50±20% at 0.1 µm, 100±10% at 0.15–0.2 µm PSL |
| Max Concentration | 10⁷ particles/m³ |
| Particle Channels | 0.1 µm & 0.3 µm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" color TFT touchscreen |
| Interface | USB Host/Device, Ethernet, RS-485 |
| Data Storage | 10,000 records (CSV) |
| Operating Environment | 15–35°C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 µm, 0.3 µm |
| Maximum Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | up to 10,000 records in CSV format |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Resolution | ≤15% (relative to 0.3 μm PSL) |
| Counting Efficiency | 50±20% at 0.1 μm, 100±10% at 0.15–0.2 μm PSL |
| Max. Concentration | 10⁷ particles/m³ |
| False Count Rate | <1 count/35 min |
| Measurement Channels | 0.1 μm and 0.3 μm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3″ color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | Internal memory (10,000 records, CSV format) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Channels | 0.1 µm, 0.3 µm |
| Maximum Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3" color TFT touchscreen |
| Communication | RS-485, Ethernet (10/100BASE-TX), USB Host/Device |
| Data Storage | up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Principle | Light Scattering |
| Calibration Standards | Compliant with JIS B9921 and ISO 21501-4 |
| Channel Configuration | Dual-channel (0.1 µm, 0.3 µm) |
| Maximum Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| False Count Rate | <1 count per 35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3" color TFT touchscreen |
| Communication Interfaces | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | Internal memory (up to 10,000 records, CSV format) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Model | 3950-00 |
| Detection Principle | Light Scattering |
| Particle Channels | 0.1 µm, 0.3 µm |
| Nominal Flow Rate | 2.83 L/min (0.1 CFM) |
| Accuracy | ±5% |
| Compliance | ISO 21501-4 & JIS B9921 |
| Display | 4.3" Color Touchscreen LCD |
| Communication | RS-458, Ethernet, USB (Host/Device) |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Max. Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| False Count Rate | <1 count per 35 min |
| Size Resolution | ≤15% (at 0.3 µm PSL) |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Channels | 0.1 μm & 0.3 μm |
| Detection Principle | Light Scattering |
| Compliance | JIS B9921 & ISO 21501-4 |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% @ 0.1 μm PSL, 100±10% @ 0.15–0.2 μm PSL |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (vs. 0.3 μm PSL) |
| Display | 4.3″ Color TFT Touchscreen |
| Communication | RS-485, Ethernet (10/100BASE-T), USB Host/Device |
| Data Storage | Internal CSV (up to 10,000 records) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Principle | Light Scattering |
| Channel Sizes | 0.1 µm and 0.3 µm |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 µm (PSL), 100±10% at 0.15–0.2 µm (PSL) |
| Size Resolution | ≤15% (vs. 0.3 µm PSL) |
| Operating Temp. | 15–35 °C, RH: 0–85% non-condensing |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Display | 4.3" color TFT touchscreen |
| Interface | USB Host/Device, Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | Internal CSV (up to 10,000 records) |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 µm and 0.3 µm |
| Counting Efficiency | 50 ± 20% at 0.1 µm (PSL), 100 ± 10% at 0.15–0.2 µm (PSL) |
| Maximum Concentration | 10⁷ particles/m³ |
| False Count Rate | <1 count per 35 min |
| Size Resolution | ≤15% (relative to 0.3 µm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | up to 10,000 records in CSV format |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Threshold | 0.1 µm and 0.3 µm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" color TFT touchscreen |
| Communication | RS-485, Ethernet, USB Host/Device |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm, 0.3 μm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 μm (PSL), 100±10% at 0.15–0.2 μm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 μm PSL) |
| Display | 4.3" color TFT touchscreen |
| Communication | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | 10,000 records, CSV format |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm & 0.3 μm |
| Measurement Principle | Light Scattering |
| Compliance | JIS B9921 & ISO 21501-4 |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% at 0.1 μm (PSL), 100±10% at 0.15–0.2 μm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (relative to 0.3 μm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Interface | USB (Host/Device), Ethernet, RS-485 (9600–38400 baud) |
| Data Storage | 10,000 records (CSV) |
| Operating Environment | 15–35°C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm & 0.3 μm |
| Max Concentration | 10⁷ particles/m³ |
| Counting Efficiency | 50±20% @ 0.1 μm (PSL), 100±10% @ 0.15–0.2 μm (PSL) |
| False Count Rate | <1 count/35 min |
| Size Resolution | ≤15% (vs. 0.3 μm PSL) |
| Display | 4.3″ color TFT touchscreen |
| Communication | RS-485, Ethernet (10/100BASE-T), USB Host/Device |
| Data Storage | internal memory (10,000 records, CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Compliance | JIS B9921, ISO 21501-4 |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm & 0.3 μm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" Color Touchscreen LCD |
| Communication | RS-485, Ethernet, USB (Host/Device) |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3950-00 |
| Flow Rate | 2.83 L/min (0.1 CFM) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±1 s per 6 min |
| Repeatability | ±5% |
| Size Distribution Error | ±15% |
| Indication Error | ±30% |
| Particle Detection Channels | 0.1 μm & 0.3 μm |
| Compliance | JIS B9921 & ISO 21501-4 |
| Display | 4.3" Color Touchscreen LCD |
| Communication | RS-485, Ethernet, USB (Host/Device) |
| Data Storage | Up to 10,000 records (CSV) |
| Operating Environment | 15–35 °C, 0–85% RH (non-condensing) |
| Dimensions | 150 × 163 × 228 mm |
| Weight | 3.4 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Supported Languages | English, French, Spanish, Portuguese, Chinese |
| Max Simultaneous Units Controlled via PC | 4 |
| Data Export Format | Microsoft Excel |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | Kanomax 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Calculation Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Language Options | English, French, Spanish, Portuguese, Chinese |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Particle Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch full-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units controlled simultaneously via single PC |
| Data Export Format | Microsoft Excel (.xlsx) |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 29 CFR 1910.134, CSA Z94.4–18 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | KANOMAX 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host×2, Device×1), Ethernet×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Max Simultaneous Units Controlled via PC | 4 |
| Data Export Format | Microsoft Excel |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C, 3000-C1 |
| Particle Size Range | 0.02–1.0 µm (3000-0C), 0.015–1.0 µm (3000-C1) |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Concentration Range | 0–100,000 particles/cm³ |
| Fit Factor Calculation | Direct Cout/Cin ratio |
| Test Agent | ≥99.5% isopropanol or ethanol |
| Display | 7-inch full-color touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions (W×H×D) | 208×117×262 mm (3000-0C), 208×152×263 mm (3000-C1) |
| Weight | 2.3 kg (3000-0C), 3.1 kg (3000-C1) |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, HSE INDG 479, GB 19083–2010, GB 2626–2019, GB/T 32610–2016 |
| Software | Windows 7/8/10, .NET Framework 3.5, Excel-compatible reporting |
| Communication | USB, Ethernet, Wi-Fi |
| Multi-unit Control | Up to 4 units per PC |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-C1 |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Challenge Agent | Isopropyl Alcohol (≥99.5% purity) or Ethanol |
| Display | 7-inch true-color touchscreen |
| Operating Temperature | 10–35 °C |
| Relative Humidity | 20–85% RH (non-condensing) |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm (W × H × D) |
| Weight | 2.3 kg |
| Compliance Standards | OSHA 1910.134, CSA Z94.4, ANSI/AIHA Z88.10, UK HSE Guidance, GB 2626–2019, GB 19083–2010 |
| Communication Interfaces | USB, Ethernet, Wi-Fi |
| Software Compatibility | Windows 7/8/10, .NET Framework 3.5 |
| Data Export Format | Microsoft Excel (.xlsx) |
| Multi-unit Control | Up to 4 units per PC |
| Language Options | English, Japanese, Chinese, French, Spanish, Portuguese |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | AccuFIT 9000 |
| Particle Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch full-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Supported Languages | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units simultaneously via single PC |
| Data Export Format | Microsoft Excel |
| Compliance | GB 2626–2019, GB 19083–2010, OSHA 1910.134, CSA Z94.4, ANSI/ASSP Z88.10 |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 3000-0C |
| Concentration Range | 0–100,000 particles/cm³ |
| Particle Size Range | 0.02–1.0 µm |
| Sampling Flow Rate | 100 cm³/min |
| Total Flow Rate | 700 cm³/min |
| Fit Factor Measurement Method | Direct (Cout/Cin) |
| Test Aerosol | 99.5% ethanol + analytical-grade isopropanol |
| Display | 7-inch true-color touchscreen |
| Communication Interfaces | USB (Host ×2, Device ×1), Ethernet ×1, Wi-Fi enabled |
| Operating Temperature | 15–35 °C |
| Power Supply | AC 110–240 V, 50/60 Hz |
| Dimensions | 208 × 117 × 262 mm |
| Weight | 2.1 kg |
| Language Support | English, French, Spanish, Portuguese, Chinese |
| Multi-unit Control | Up to 4 units simultaneously via single PC |
| Data Export Format | Microsoft Excel |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 3080 |
| Flow Rate | 100 L/min |
| Accuracy | ±2.5% |
| Sampling Principle | Andersen Impaction (6-stage cascade impactor) |
| Impact Velocity | <20 m/s |
| Sampling Volume Range | 20–6000 L |
| Interval Time | 10 s–1 h |
| Delay Time | 0 s–23 h 59 min 59 s |
| Sampling Cycles | 2–300 or continuous |
| Petri Dish Compatibility | 90–100 mm and 55–84 mm |
| Exhaust Filter Class | ISO Class 3 |
| Display | 4.3-inch color touchscreen |
| Data Storage | 10,000 internal records + USB export (CSV format) |
| Communication | USB, RS-485 (Modbus RTU) |
| Power Supply | Li-ion rechargeable battery (7 h operation) + AC 100–240 V adapter |
| Operating Environment | 0–40 °C, 0–90% RH (non-condensing) |
| Weight | 3.2 kg |
| Dimensions | 136 × 235 × 133 mm |
| User Management | 64 editable users with multi-level permission control and audit trail |
| Remote Control | IR remote (supports up to 5 units simultaneously) |
| Language Support | English, Japanese, Chinese |
| Alarm | Visual & audible flow deviation alert |
| Materials | 316 stainless steel sampling head |
| Compliance | Designed for ISO 14698-1, ISO 14644-1/2, EU GMP Annex 1, USP <1116>, and FDA 21 CFR Part 11-ready data integrity architecture |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | CRMS |
| Price Range | USD 14,000 – 28,000 |
| Instrument Type | Online Continuous Monitoring System |
| Flow Rate | High-Flow (1 CFM / 28.3 L/min and 0.1 CFM / 2.83 L/min options) |
| Flow Accuracy | < ±1 count per 5 min |
| Timing Accuracy | ±1 s within 6-min sampling |
| Repeatability | ≤ ±10% FS |
| Particle Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Brand | KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EP-CRMS |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Instrument Type | Online Continuous Monitoring System |
| Flow Rate | High-Flow (28.3 L/min standard configuration) |
| Flow Accuracy | < ±1 particle per 5 min |
| Timing Accuracy | ±1 s over 6-min sampling interval |
| Repeatability | ≤ ±10% FS |
| Particle Size Distribution Error | ≤ ±30% |
| Indication Error | < ±30% FS |
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | EP-CRMS |
| Type | Online Particle & Environmental Monitoring System |
| Compliance | EU GMP Annex 1, FDA 21 CFR Part 11, ISO 14644-1/2, ISO 21501-4, ISO 14698-1, USP <797>/<800>, China GMP 2010, GB/T 16292–16293, GB 50591-2010 |
| Particle Sensor Options | 0.3/0.5 µm, 0.5/5.0 µm, or multi-channel (0.3–10.0 µm, 2–4 selectable sizes) |
| Flow Rates | 2.83 L/min (0.1 CFM) or 28.3 L/min (1.0 CFM) |
| Laser Source | Long-life diode (>100,000 hr MTBF) |
| Data Storage | Up to 4,320 records per sensor with timestamp, audit trail, and CRC integrity check |
| Communication | RS485 (Modbus RTU/TCP), 4–20 mA, Ethernet (select models) |
| Power | DC 9–28 V or AC 100–240 V |
| Enclosure Material | 316 stainless steel sampling heads |
| Vacuum System | Dual redundant dry-running oil-free rotary vane pumps (N+1 configuration) |
| Alarm Logic | Multi-level (Alert/Action/Alarm), configurable thresholds, real-time audible/visual notification, and automated equipment interlock (e.g., filler stop/start) |
| Software Features | Electronic signatures, 21 CFR Part 11-compliant audit trail, UCL calculation per ISO 14644-1, automated report generation (PDF/Excel), trend analysis, historical data review, and backup archiving |
| Brand | Kanomax |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | EP-CRMS |
| Instrument Type | Online Particle Monitoring System |
| Flow Rate | High-Flow (28.3 L/min standard) |
| Flow Accuracy | <1 count deviation per 5 min |
| Timing Accuracy | ±1 s over 6-min sampling |
| Repeatability | ≤±10% FS |
| Size Distribution Error | ≤±30% |
| Indication Error | <±30% FS |
| Compliance | ISO 21501-4, JIS B 9921, ISO 14698-1, FDA 21 CFR Part 11, EU GMP Annex 1, GB/T 16292–16293, GB 50591-2010 |
| Data Storage | Up to 2,000 sample records per sensor |
| Communication | RS485 (Modbus RTU/TCP), optional 4–20 mA |
| Power Supply | DC 9–28 V or AC 100–240 V (50–60 Hz) |
| Laser Source | Long-life semiconductor diode (MTBF >100,000 h) |
| Key | Brand: KANOMAX |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EP-CRMS |
| Instrument Type | Online Monitoring System |
| Flow Rate | High-Flow (28.3 L/min standard) |
| Flow Accuracy | <1 count deviation per 5 min |
| Timing Accuracy | ±1 s over 6-min sampling interval |
| Repeatability | ≤±10% FS |
| Particle Size Distribution Error | ≤±30% |
| Indication Error | <±30% FS |
| Brand | KANOMAX |
|---|---|
| Origin | Japan |
| Instrument Type | Handheld Particle Counter |
| Flow Rate | 2.83 L/min ±5% |
| Detectable Particle Sizes | 0.3, 0.5, 1.0, 3.0, 5.0 µm (3887Pro) |
| Display | 3.5-inch resistive touchscreen |
| Light Source | Laser diode |
| Counting Efficiency Compliance | ISO 21501-4 & JIS B9921 |
| Max. Concentration | 2,000,000 particles/ft³ |
| Coincidence Loss | <5% at 2,000,000 particles/ft³ |
| Data Storage Capacity | 7,000 sample records |
| Power Supply | Rechargeable Li-ion battery (≈5 h operation) + USB-C AC adapter |
| Dimensions | 87 × 200 × 55 mm |
| Weight | ≈600 g |
| Operating Environment | 10–40 °C, 0–85% RH (non-condensing) |
| Communication Interfaces | USB & RS-485 |