| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Model | S4-PULSAR |
| Principle | Non-Dispersive Infrared (NDIR) with Gas Filter Correlation (GFC) |
| Type | Online Fixed-Mount Analyzer |
| Response Time | Gas- and concentration-dependent (typically < 15 s for major components) |
| Repeatability | ±0.5 ppm or ±1% of full scale (whichever is greater) for CO, CO₂, NO, SO₂, N₂O, CH₄, HCl, O₂ |
| Linearity | Better than ±1% FS |
| Display | 5.7″ color TFT touchscreen |
| Data Storage | Integrated SD card logging (all channels, timestamped) |
| Connectivity | USB host/device port |
| Software | Free PC-based data acquisition and configuration suite included |
| Compliance | Designed for continuous emissions monitoring (CEM) and laboratory-grade trace gas analysis |
| Sample Compatibility | Dry or humidified gas streams |
| Brand | SIGNAL |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOLAR |
| Detection Principle | Heated Flame Ionization Detector (HFID) |
| Instrument Type | Online Continuous Analyzer |
| Typical Configuration | Dual-Channel VOC & NMHC Analyzer |
| Measurement Ranges | 0–1 ppm, 0–10 ppm, 0–1,000 ppm, 0–10,000 ppm |
| Resolution | ±1% of reading |
| Accuracy | ±1% of reading |
| Brand | Signal |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Solar-01 |
| Pricing | Upon Request |
| Detection Principle | Heated Flame Ionization Detector (HFID) |
| Instrument Type | Online Analyzer |
| Typical Configuration | Compound VOC Analyzer |
| Resolution | ±1% of reading |
| Response Time | <2 seconds |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SIM 6300 |
| Pricing | Upon Request |
| Air Velocity | 600 mm/s |
| Air Exchange Rate | Up to 500 dm³/h |
| Exterior Material | Anodized Aluminum |
| Viewing Window Dimensions | 680 × 680 mm |
| Adjustable Sample Height | ±20 mm |
| Weight | 143 kg |
| Ozone Concentration Range | 25–1000 ppm (PPHM) |
| Power Consumption | Max. 1000 W |
| Brand | Sinoptic |
|---|---|
| Model | mLAS-700 |
| Measurement Range | 0–20 ppm NH₃ |
| Accuracy | ±0.1 ppm |
| Response Time | ≤15 s |
| Repeatability | ±0.5% FS over 30 min |
| Operating Temperature | −20 to +55 °C |
| Output Interface | MODBUS RTU (RS-485) |
| Optical Path | Single-pass, Reference-free |
| Customization Options | High-temperature optical cell |
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Sintering Machine Desulfurization |
| Price | Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | UAV-Mounted Integrated Sensor Payload |
| Price Range | USD 140,000 – 210,000 |
| Product Category | Atmospheric Heavy Metal & Particulate Matter Online Analyzer |
| Measurement Principle | Laser Scattering (PM), Electrochemical (SO₂, NO₂, CO, O₃), Photoionization (VOC), Optical Absorption (optional heavy metal speciation via integrated micro-XRF or LIBS module*) |
| Measurement Range | TSP, PM₁₀ (0–1999 µg/m³), PM₂.₅ (0–999 µg/m³), O₃/SO₂/NO₂ (0–1 ppm), CO (0–200 ppm), VOC (0–50 ppm) |
| Detection Limit | 1–10 ppb (gas species) |
| Filter Replacement Interval | 30 days (under typical urban ambient conditions) |
| Operating Temperature | −30 °C to +60 °C |
| Operating Humidity | 15–95% RH (non-condensing) |
| Ambient Pressure Range | 80–106 kPa |
| Power Supply | 12–24 V DC |
| Weight | 950 g (7-parameter standard configuration) |
| Dimensions | 220 × 145 × 60 mm |
| Battery Endurance | ≥10 h continuous operation (with onboard LiPo power management) |
| Data Transmission | Dual-mode GPRS + 2.4 GHz RF telemetry (AES-128 encrypted) |
| Compliance | ISO 9001-certified manufacturing |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | 224-PCXR8 |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 5–5000 mL/min (UL-certified) |
| Weight | 964 g (34 oz) |
| Dimensions | 13 × 11.9 × 4.8 cm (5.1 × 4.7 × 1.9 in) |
| Battery | Rechargeable 6.0-V NiMH (3.5 Ah) or NiCd (2.0 Ah) |
| Operating Temperature | 0–40 °C |
| Flow Accuracy | ±5% of setpoint after calibration |
| Timer Range | 1–9999 min (±0.05% accuracy) |
| Intrinsic Safety Certification | UL Listed for Class I, Div. 1 & 2, Groups A–D |
| EMC Compliance | EN 55022, FCC Part 15 Class B, EN 50082-1 |
| Brand | SKC |
|---|---|
| Origin | USA |
| Product Type | Imported Air Sampling Filter Membranes |
| Material Options | Cellulose Ester (MCE), Polyvinyl Chloride (PVC), Polytetrafluoroethylene (PTFE), Polycarbonate (PC), Silver (Ag), Glass Fiber (GF), Quartz (QZ), Gelatin (GEL) |
| Available Diameters | 13 mm, 25 mm, 37 mm, 47 mm, 90 mm, 102 mm, 8×10 inch |
| Pore Sizes | 0.3–10 µm (material-dependent) |
| Packaging | 25–1000 pieces per box |
| Sterilization | Gamma-irradiated (Gelatin), Autoclavable (PTFE, PC, Ag, GF, QZ), Solvent-compatible (Ag, MCE, PTFE) |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | AirChek Connect Pump |
| Instrument Type | Handheld Air Sampling Pump |
| Sampling Configuration | Single-Channel Gas Sampler |
| Flow Range | 5–5000 mL/min |
| Pressure Compensation | Up to 60 in H₂O (at 1000 mL/min) |
| Flow Stability | ±5% |
| Flowmeter Accuracy | ±5% |
| Battery Life | ≥50,000 hours MTBF |
| Runtime | >40 h at 2000 mL/min |
| Inlet Pressure Sensitivity | ±0.3 in Hg |
| Operating Temperature | –20 °C to +45 °C |
| Certifications | ATEX/IECEx Zone 0, UL Class I/II/III, ISO 13137:2013 compliant |
| Weight | 550 g |
| Dimensions | 10.4 × 9.4 × 7.1 cm |
| Noise Level | 51.7 dB(A) @ 1 m (with 37 mm, 0.8 µm MCE filter) |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | AirChek ESSENTIAL |
| Certification | UL/ATEX Intrinsically Safe |
| Flow Range | 5–5000 mL/min |
| Backpressure Compensation | Up to 50 in. H₂O at –2 L/min |
| Battery Life | >40 hours (typical use) |
| Display | Backlit LCD with touch-sensitive interface |
| Sensor Type | Isothermal mass flow sensor |
| Enclosure | ESD-safe, slip-resistant, ruggedized polymer housing |
| Compliance | Meets OSHA, NIOSH, and ISO 13137 requirements for personal air sampling |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | AirChek Touch (220-5000TC) |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 5–5000 mL/min |
| Backpressure Compensation | Up to 50 in. H₂O |
| Flow Control | Constant-Flow with Isothermal Compensation |
| Flow Accuracy | ±5% of setpoint |
| Battery Life | ≥20 hours at 2000 mL/min |
| Expected Service Life | 10 years under maximum flow and backpressure conditions |
| Certifications | UL Class I, Div. 1 (Groups A–D), Class II, Div. 1 (Groups E–G), Class III, Div. 1 |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Airchek XR5000 |
| Flow Range | 5–5000 mL/min |
| Flow Accuracy | ±5% after calibration |
| Timer Accuracy | ±1 min at 25°C |
| Backpressure Compensation | up to 2000 mL/min @ 50 in. H₂O |
| Charging Time | 4–8 hours |
| Operating Temperature | 0–45°C (32–113°F) |
| Storage Temperature | −20–35°C (−4–113°F) |
| Charging Temperature | 0–45°C (32–113°F) |
| Display | LCD with blue LED status indicators |
| Keypad | 3-button interface |
| Time Format | 12- or 24-hour selectable |
| Volume Calculation | Real-time flow × elapsed time |
| Sampling Duration Setting | 1–9999 minutes (auto-rollover to 1 after overflow) |
| Fault Recovery | Auto-restart every 15 s for up to 5 attempts upon flow error |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | AirChek XR5000 |
| Flow Range | 5–5000 mL/min |
| Power Options | High-Capacity Li-ion (4-cell, 7.4 V, 4.4 Ah), Standard Li-ion (2-cell, 7.4 V, 2.2 Ah), or Alkaline Batteries |
| Accuracy | ±5% of set flow rate with active backpressure compensation |
| Operating Temperature | 0–45 °C |
| Storage Temperature | −20–45 °C |
| Timer Range | 1–9999 min (6.8 days) |
| Compliance | CE-marked, RFI/EMI-shielded for use in hazardous locations, UL-listed |
| Safety Features | Auto-shutdown on sustained low-flow (<15 s recovery), 5-attempt auto-restart sequence, low-battery sleep mode after 15 s idle, automatic pump stop after 5 min inactivity |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | AirChek52 |
| Flow Range | 5–3000 mL/min (5–500 mL/min with Low-Flow Kit) |
| Backpressure Compensation | Up to 25 in. H₂O |
| Operating Time | >8 h at 2000 mL/min & 25 in. H₂O |
| Flow Accuracy | ±5% after calibration |
| Weight | 566 g |
| Dimensions | 12.7 × 7.6 × 4.4 cm |
| Display | LCD showing sampling time, flow status, low-battery warning, and flow error alert |
| Auto-Shutoff | Enabled upon ±5% flow deviation |
| Safety Certification | UL & cUL Listed |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | AirLite® |
| Flow Range | 5–3000 mL/min (5–500 mL/min with optional Low-Flow Kit) |
| Backpressure Compensation | Up to 30 in. H₂O |
| Battery Life | ≥8 hours at full flow range using alkaline AA batteries |
| Flow Accuracy | ±5% after calibration |
| Weight | 340 g |
| Dimensions | 10.1 × 7.9 × 4.8 cm |
| Power Supply | Two 1.5 V AA alkaline batteries |
| Display | LED indicators for sampling status, flow condition, and low-battery warning |
| Auto-Shutdown | Activates when flow error exceeds ±5% |
| Built-in | Flow pulse dampener, particulate filter |
| External Mounting | Dedicated orifice for impactor bottle bracket |
| EMI/RFI Shielding | Conductive polymer housing compliant with IEC 61000-4 series immunity standards |
| Certifications | Meets OSHA, NIOSH, and ISO 13137 requirements for personal air sampling pumps |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Anasorb CSC Activated Carbon Sorbent Tube |
| Pricing | Available Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Anasorb Sorbent Tubes |
| Type | Pre-packed, Certified Air Sampling Sorbent Tubes for Occupational & Environmental Monitoring |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | BioLite+ |
| Flow Rate | 62 L/min (max) |
| Max Backpressure | 850 mbar |
| Power Supply | 120 V AC or 230 V AC |
| Operating Temperature | 0–40 °C |
| Operating Humidity | 0–95% RH |
| Noise Level | 61–66 dB(A) at 1 m |
| Dimensions | 162 × 209 × 303 mm |
| Weight | 7.25 kg |
| Enclosure | Steel housing with integrated handle |
| IP Rating | IP20 |
| Flow Control | Manual adjustment with built-in backpressure gauge |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | BioSampler® |
| Flow Rate | 12.5 L/min |
| Construction | Borosilicate Glass |
| Sterilization | Autoclavable |
| Sampling Duration | Up to 8 hours |
| Collection Medium | Aqueous or viscous liquid (e.g., ViaTrap® mineral oil) |
| Inlet/Outlet | Standard ground-glass joints |
| Compatible Pump | SKC BioLite® sonic-flow pump |
| Nozzle Configuration | Triple tangential jets at optimized angles |
| Particle Size Cut-off | Approx. ≤10 µm aerodynamic diameter (human inhalable fraction) |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | BioStage (228-9611) |
| Flow Rate | 28.3 L/min |
| Material | Anodized aluminum (inlet cone & base plate, autoclavable) |
| O-Ring | Duro 50 / BUNA-N (non-autoclavable) |
| Impaction Stage | 400 nozzles (0.25 mm diameter) |
| Cut-Off Size (D50) | 0.6 µm |
| Sampling Medium | 90–100 mm standard agar plates |
| Compliance | NIOSH Methods 0800 & 0801, ACGIH Bioaerosol Sampling Guidelines |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Button |
| Sampling Flow Rate | 4 L/min |
| Cut-Off Diameter | 100 µm (aerodynamic) |
| Sampler Type | Cassette-style filter-based inhalable sampler |
| Inlet Material | Conductive stainless steel |
| Filter Holder | 25 mm diameter |
| Compatible Filters | MCE, PVC, polycarbonate, gelatin |
| Calibration Adapter | Included |
| Compliance | ISO 7708:1995, CEN 13205:2002, ACGIH® Inhalable Fraction Criteria |
| Reusable | Yes |
| O-Ring Materials | PTFE (inlet), BUNA-N (body) |
| Mounting | Stainless steel and nylon clip |
| Transport Case | Conductive plastic carrying case |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Chromosorb |
| Pricing | Available Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | TD Tube |
| Adsorbent | Carbopack X |
| Tube Material | SilcoNert 2000-coated stainless steel |
| Dimensions | 3.5 in × 0.25 in OD |
| Diffusion Rate (Benzene) | 0.67 mL/min |
| Compliance | EPA Method 325A, HSE MDHS 104 |
| Analytical Method | GC-FID or GC-MS per EPA Method 325B |
| Storage Requirement | Use within 30 days after conditioning |
| Fitting | Brass Swagelok nut with PTFE ferrule |
| Includes | Diffusion cap (P/N 10526-100), shelter (P/N 526-100), barcode & orientation arrow marking |
| Sample Duration | 14-day integrated sampling |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | DNPH-Silica |
| Dimensions (ID × Length) | 6 mm × 100 mm or 8 mm × 115 mm |
| Sorbent Mass | 300/150 mg (6×100 mm) or 1500/300/150 mg (8×115 mm) |
| Sorbent | High-Purity Silica Coated with DNPH |
| Compliance | HJ 683–2014, HJ/T 400–2007, GB/T 39897–2021, GB/T 27630–2011, NIOSH 2016, EPA TO-11A, MDHS 102, ASTM D5197/D6196 |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DPS |
| Pricing | Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DPS-PM2.5 |
| Pricing | Contact for Quote |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Flite 3 |
| Flow Range | 2,000–20,000 mL/min |
| Power Options | Rechargeable Lead-Acid Battery (3.2 Ah or 7 Ah) or AC Adapter |
| Operating Temperature | −5 to 50 °C |
| Housing | Rugged Steel Enclosure with Integrated Handle |
| Dimensions | 11.5 × 20.6 × 17.8 cm |
| Weight | 2.24 kg (bare), 3.56 kg (with 3.2 Ah battery), 4.48 kg (with 7 Ah battery) |
| Compliance | Designed for ASTM D6330, ISO 16000-2, NIOSH Method 7400/7402, and OSHA ID-160 applications |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Grab Air |
| Flow Rate | 1.0 L/min |
| Power Source | Single 9V Alkaline Battery |
| Battery Life | ~1000 L at 1.0 L/min |
| Dimensions | 10.8 × 6.3 × 2.7 cm (4.25 × 2.5 × 1.1 in) |
| Weight | 186 g (6.6 oz) |
| Pump Type | Diaphragm |
| Intrinsic Safety | Not certified for hazardous or explosive atmospheres |
| Sample Interface | Direct bag connection via outlet port |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | HAZ-DUST 7204 |
| Sensor Type | 90° Optical Light Scattering (880 nm) |
| Measurement Range | 0.001–500 mg/m³ (1–500,000 µg/m³) |
| Resolution | 1 µg/m³ |
| Accuracy | ±10% vs. gravimetric filter mass (SAE Fine Test Dust, ISO 12103-1 A2) |
| PM Size Coverage | 0.1–100 µm |
| Cut-Point Compatibility | IOM (2.0 L/min), GS-3 Cyclone (2.75 L/min, 4 µm), Thoracic (2.0 L/min), Chest (2.0 L/min) |
| Flow Control | 1–5 L/min, maintained within ±5% across backpressures up to 70 inH₂O |
| Display | 3.5″ 24-bit resistive color touchscreen with auto-brightness |
| Battery | Rechargeable Li-ion (7.4 V, 3350 mAh) |
| Operating Temp | 0–50 °C |
| Humidity | 0–95% RH non-condensing |
| Data Storage | 43,200 points |
| Sampling Intervals | 1, 4, 10, or 60 s |
| Compliance | CEN/ISO 7708, OSHA Silica Rule (29 CFR 1926.1153), MSHA DPM standards |
| Software | DustComm Pro (Windows 10+) |
| Certifications | CE, UL, CB, CUL, PSE, RCM |