| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Thermo Scientific |
| Pricing | Available Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | FGD-CEMS |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Dilution Extraction with UV/IR Absorption and Paramagnetic/O2 Electrochemical Detection |
| Key Parameters | SO₂, NOₓ, CO, O₂, Flow Rate, Temperature, Static Pressure, Particulate Matter (PM), Relative Humidity, Total Reduced Sulfur (TRS), H₂S |
| Compliance Framework | EPA Performance Specifications (PS-2, PS-3, PS-5, PS-15), EN 15267, ISO 14001, US EPA Method 6C, Method 7E, Method 10, Method 3A, ASTM D6522, ASTM D5197 |
| Data Integrity | 21 CFR Part 11–compliant audit trail, GLP/GMP-ready reporting |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Thermo Scientific FH62C14 |
| Measurement Principle | Beta Ray Attenuation |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Range | 0–5,000 µg/m³ or 0–10,000 µg/m³ (selectable) |
| LOD | 4 µg/m³ (1-hr avg), 1 µg/m³ (24-hr avg) |
| Flow Rate | 1 m³/h (16.7 L/min) |
| Radioisotope | ¹⁴C sealed source in BaCO₃ matrix |
| Activity | <3.7 MBq (<100 µCi), exempt under U.S. NRC regulations |
| Data Storage | >1 year of half-hourly mass concentration averages |
| Flow Mode Options | Standard temperature & pressure (STP) or actual ambient flow |
| Interference Compensation | Automatic correction for ambient radioactivity |
| Environmental Robustness | Immune to vibration and diurnal temperature fluctuations |
| Communication | Dual RS-232 serial ports for remote control and data export |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | FH62C14 |
| Measurement Method | Beta-Ray Absorption |
| Measured Parameter | PM2.5 |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Activity | <3.7 MBq (<100 μCi) |
| Measurement Range | 0–5000 μg/m³ or 0–10000 μg/m³ |
| LOD (24-h avg) | <1 μg/m³ |
| LOD (1-h avg) | <4 μg/m³ |
| Accuracy | ±2 μg/m³ (24-h) |
| Resolution | ±1 μg/m³ (instantaneous) |
| Correlation Coefficient | R > 0.98 |
| Sampling Flow Rate | 1 m³/h (16.67 L/min), adjustable 0–20 L/min via built-in critical orifice |
| Operating Temperature | −30 °C to +60 °C |
| Data Averaging Intervals | 0.5, 1, 3, and 24 hours |
| Storage Capacity | >1 year of half-hourly averages |
| Communication Interfaces | Dual RS-232 serial ports |
| Analog Outputs | 4–20 mA or 0–10 V |
| Power Supply (Analyzer) | 100–240 VAC, 50/60 Hz, 15 W |
| Power Supply (Pump) | 220–240 VAC, 50/60 Hz, 100 W |
| Dimensions (Analyzer) | 483 mm (W) × 311 mm (H) × 330 mm (D) |
| Weight (Analyzer) | 22.5 kg |
| Dimensions (Pump) | 210 mm (W) × 222 mm (H) × 108 mm (D) |
| Weight (Pump) | 8.16 kg |
| Regulatory Certifications | U.S. EPA and California Air Resources Board (CARB) equivalency for PM₂.₅ and PM₁₀ |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Thermo Scientific GM-5000 |
| Measurement Principle | Optical Scattering (for PM), Electrochemical (for SO₂, NO₂, NO, CO), Photoionization Detection (for TVOC), UV Absorption (for O₃) |
| Measured Parameters | PM₂.₅, PM₁₀, SO₂, NO₂, NO, O₃, CO, TVOC |
| Measurement Range | PM₂.₅ / PM₁₀: 0–1500 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 0–500 ppb |
| CO | 0–50 ppm |
| TVOC | 0–40 ppm |
| Sampling Interval | 10 s |
| Sample Flow Rate | >1.5 L/min |
| Detection Limits | PM₂.₅ / PM₁₀ <1.0 µg/m³ |
| SO₂ / NO₂ / NO / O₃ | 5 ppb |
| CO | 0.02 ppm |
| TVOC | 5 ppb |
| Flow Stability | ±2.5% of full scale (all sensors) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | GM-5000 |
| Instrument Type | Online Fixed-Station Monitor |
| Measured Gases | NO₂, SO₂, O₃, CO |
| Response Time (T90) | 120 s (all sensors) |
| Measurement Accuracy | ±10 ppb (gaseous pollutants) |
| Measurement Ranges | NO₂: 0–20 ppm |
| SO₂ | 0–50 ppm |
| O₃ | 0–20 ppm |
| CO | 0–500 ppm |
| PM₂.₅ | 0–1500 µg/m³ |
| PM₁₀ | 0–1500 µg/m³ |
| Detection Limits (2σ) | NO₂: 30 ppb |
| SO₂ | 40 ppb |
| O₃ | 30 ppb |
| CO | 25 ppb |
| PM₂.₅ & PM₁₀ | <1.0 µg/m³ |
| Linearity | ±5% of full scale |
| Zero Drift | ±1% of full scale |
| Repeatability | ±2.5% of full scale |
| Resolution | 10 ppb (gases), 0.1 µg/m³ (PM) |
| Sample Flow Rate | >1.5 L/min |
| Data Logging Interval | 1 min to 1 h |
| Onboard Storage | >500,000 records (~1 year) |
| Operating Temperature | –10 °C to +45 °C |
| Operating Humidity | 15–90% RH (non-condensing) |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Dimensions | 406 mm (H) × 305 mm (W) × 152 mm (D) |
| Weight | 5 kg |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Hg CEMS |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | 3880i |
| Instrument Type | Flue Gas PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM) |
| Traceability | NIST-traceable mass concentration |
| Compliance | EPA PS-11, QA/QC Procedure 2, Method 5/17 Verified |
| Range | 0–250 mg/m³ (extendable to 0–5 mg/m³ low-range mode) |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integrated) |
| Response Time (T90) | 15 min |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Purge Air | 80 slpm at 0.55–0.7 MPa |
| Max Flue Gas Temp | 200 °C |
| Operating Ambient Temp (Controller) | 4–50 °C, non-condensing |
| Analog Outputs | 6 × 0–100 mV / 1/5/10 V, 6 × 0–20 mA / 4–20 mA |
| Digital I/O | 1 power-fail alarm, 10 relay outputs |
| Probe Dimensions | 1117.85 mm (W) × 474.73 mm (H) × 7.09 mm (D), with 914/1524 mm sheath |
| Probe Weight | 59 kg |
| Controller Dimensions | 482.6 mm (19″ W) × 189.5 mm (H) × 655.32 mm (D) |
| Controller Weight | 25 kg |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | 5012, MAAP |
| Measurement Principle | Multi-angle absorption photometry |
| Measured Parameters | BC (Black Carbon), PM₁₀, PM₂.₅ |
| Detection Limit (2-min avg) | <100 ng/m³ BC, <0.66 M/m Babs |
| Detection Limit (10-min avg) | <50 ng/m³ BC, <0.33 M/m Babs |
| Detection Limit (30-min avg) | <20 ng/m³ BC, <0.13 M/m Babs |
| Flow Rate | 0.5–1.4 m³/h (16.7 L/min nominal) |
| Linearity Error | <1% @ 16.7 L/min |
| Filter Medium | Glass fiber tape (~40 m length) |
| Data Storage | 18,560 concentration values |
| Operating Temperature | −20 to +50 °C |
| Power | Instrument: 100–240 V, 50/60 Hz, 30 W |
| Pump | 220–240 V, 50/60 Hz, 100 W |
| Dimensions (Instrument) | 483 × 311 × 330 mm (W×H×D) |
| Weight (Instrument) | 22.5 kg |
| Pump Dimensions | 210 × 222 × 108 mm |
| Pump Weight | 6.1 kg |
| Analog Output | 0/4–20 mA or 0–10 V |
| Digital Interface | Dual RS-232 serial ports |
| Sampling Efficiency | >98% duty cycle |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Model 5014i Beta |
| Measurement Principle | Beta-ray attenuation |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Radioisotope Source | Carbon-14 (¹⁴C) |
| Range Options | 0–1.0 / 2.0 / 3.0 / 5.0 / 10.0 mg/m³ (equivalent to 0–100 / 1,000 / 2,000 / 3,000 / 5,000 / 10,000 µg/m³) |
| LOD | 6 µg/m³ (0.5-hr avg), 4 µg/m³ (1-hr avg), 3 µg/m³ (3-hr avg), 1 µg/m³ (24-hr avg) |
| Resolution | 1 µg/m³ |
| Accuracy | ±5% (mass measurement, NIST-traceable membrane standards) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Thermo Scientific 5030 SHARP (High-Volume Sampling Configuration) |
| Instrument Type | High-Volume Ambient Air Sampler |
| Sampling Path | Single-Channel |
| Flow Range | PM₁₀ & PM₂.₅: 40 SCFM (1,133 L/min) |
| Flow Accuracy | Mass Flow Control: ±2.5% deviation over 24 h |
| Volumetric Flow Control | <1% deviation over 24 h |
| Power | 750 W (Mass Flow) / 840 W (Volumetric Flow) |
| Motor | 0.6 HP (Mass Flow) / 0.1 HP (Volumetric Flow) |
| Compliance | EPA Reference Method for PM₁₀/PM₂.₅ (40 CFR Part 53), ISO 12103-1, ASTM D1424 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Type | Imported Instrument |
| Model | 5030i |
| Measurement Principle | Beta-ray Absorption + Light Scattering (Nephelometry) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Detection Limit | <0.5 µg/m³ (1-hr, 2σ), <0.2 µg/m³ (24-hr, 2σ) |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±5% (mass-based, traceable to NIST) |
| Range | 0–10,000 µg/m³ (7 full-scale options) |
| Flow Rate | 16.67 L/min (1 m³/h), ±2% accuracy |
| Operating Temperature | Sample gas: −30 to +50 °C |
| Analyzer enclosure | +4 to +50 °C |
| Power | 100–240 VAC, 50/60 Hz, max 880 W |
| Dimensions | 425 mm (W) × 584 mm (D) × 219 mm (H) |
| Weight | 19 kg |
| Compliance | US EPA Federal Equivalent Method (FEM) for PM₂.₅ and PM₁₀, CE, UL 61010-1, CSA C22.2 No. 61010-1, FCC Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Reference/Equivalent Method PM Sampler |
| Models | Partisol 2000i (single-channel), Partisol 2000i-D (dual-channel) |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min (2000i-D), Coarse Particle Flow Rate: 1.67 L/min (2000i-D) |
| Total Flow Range | 5–17 L/min (2000i) |
| Data Storage | 86 days @ 5-min intervals, 32 filter records |
| Operating Temperature | −40 °C to +50 °C |
| Power | 1.1 A @ 240 VAC |
| Dimensions (H×W×D) | 1620 mm × 1175 mm × 927.5 mm (base unit) |
| Weight | 37.2 kg (2000i), 38.6 kg (2000i-D) |
| Compliance | U.S. EPA RFPS-0498-117 (PM₂.₅), RFPS-1298-126 (PM₁₀), RFPS-0509-175 (Coarse PM) |
| Filter Format | Dual 47 mm filter holders (2000i-D), single 47 mm holder (2000i) |
| Cut Points | PM₂.₅ (cyclone or impactor), PM₁₀ (inlet), Coarse PM (PM₁₀–PM₂.₅ via virtual impactor in 2000i-D) |
| Interface | RS-232, USB, Ethernet |
| Software | iPort™ Communications Suite, Activol™ Flow Management System |
| Safety Certification | CE EN 61326 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 2000i-D / 2000i |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15 L/min |
| Coarse Particle Flow Rate | 1.67 L/min |
| Filter Format | Dual 47 mm membrane holders |
| Data Logging Interval | 5 min |
| Internal Memory Capacity | 86 days @ 5-min intervals + 32 filter records |
| Communication Interfaces | RS-232, USB, Enhanced Ethernet (iPort™) |
| Operating Temperature Range | −40 °C to +50 °C |
| Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), Equivalent Method for PM₁₀ and Coarse PM (PM₁₀–PM₂.₅), ASTM D6216, ISO 7708 |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 2015i/2025i-D |
| Typical Configuration | EPA Reference/Equivalent Method PM₂.₅ and Coarse PM Sampler |
| Flow Control | Mass Flow Controller (MFC) |
| Fine Particle Flow Rate | 15.0 L/min ±2% |
| Coarse Particle Flow Rate | 1.67 L/min ±2% |
| Filter Format | Dual 47 mm membrane filters per sampling cycle |
| Filter Capacity | Up to 16 filter cassettes (32 total filters) |
| Data Logging Interval | 5-minute resolution |
| Internal Memory | 86 days of operational data (5-min intervals) + 32 filter cycle records |
| Communication Interfaces | RS-232, USB 2.0, Ethernet (10/100 Mbps), iPort™ embedded communications module |
| Operating Temperature Range | −40 °C to +50 °C |
| Regulatory Compliance | U.S. EPA Reference Method for PM₂.₅ (40 CFR Part 53), EPA Equivalent Method for PM₂.₅ and Coarse PM (PM₁₀–PM₂.₅), ISO 12103-1, ASTM D1739, EN 12341 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Models | Partisol 2025i, Partisol 2025i-D |
| Flow Control | Activol Mass Flow Controller |
| Volume Flow Range | 1.67–15 L/min |
| Flow Accuracy | ±2% of setpoint |
| Operating Temperature | −40 °C to +50 °C |
| Power Requirement | 1.5 A @ 240 VAC |
| Data Storage | 86 days at 5-minute intervals + 32 filter records |
| Compliance | U.S. EPA Reference Methods RFPS-0498-118 (PM₂.₅), RFPS-1298-127 (PM₁₀), RFPS-0509-176 (Coarse PM) |
| Safety Certification | CE / EN 61326 |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | PDM3600 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Safety Rating | Non-explosion-proof |
| Measurement Range | 0–200 mg/m³ |
| Resolution | 0.05 mg/m³ (1σ, 30-sec average) |
| Accuracy | ±25% of reference method (for concentrations >0.2 mg/m³) |
| Relative Humidity Range | 0–100% RH |
| Operating Temperature | −20°C to +40°C |
| Mass Sensor Temperature Range | 0°C to +60°C |
| Sampling Flow Rate | 2.2 L/min (±2% σ in lab |
| Minimum Detectable Load | 0.1 mg |
| Maximum Load Capacity | 4 mg |
| Dimensions (Monitor Housing) | 24.31 cm W × 8.26 cm D (excl. clip) / 8.69 cm D (incl. clip) × 17.15 cm H (excl. PTO) / 19.30 cm H (incl. PTO) |
| Weight (Monitor) | 2.27 kg |
| Umbilical Cable | 167 cm long, 0.51 kg |
| TEOM Sensor Module | 5.82 cm W × 4.9 cm D × 7.75 cm H |
| Charging Module | 7.21 cm W × 15.25 cm D × 19.38 cm H, 1.42 kg |
| Power Supply | Dual internal lithium-ion battery packs |
| Compliance | MSHA Approval No. 19-A040002-0 |
| EN 61326-1 | 2005 |
| Charger | ANSI/UL 1012, Class 2, 7th Ed. (Apr 29, 2005) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | PDM 3700 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Safety Rating | Intrinsically Safe (MSHA/NIOSH Certified) |
| Measurement Range | 0–200 mg/m³ |
| Resolution | ±25% of reference method (for concentrations >0.2 mg/m³) |
| Accuracy | ±2% (2σ, laboratory), ±5% (2σ, underground coal mine) |
| Relative Error | ±25% of reference method (for concentrations >0.2 mg/m³) |
| Sampling Flow Rate | 2.2 L/min (±2% at lab, ±5% in mine) |
| Mass Sensitivity | 0.05 mg/m³ (1σ, 30-sec average) |
| Operating Temperature | −20 °C to +40 °C |
| Sensor Temperature Range | 0 °C to +60 °C |
| Relative Humidity | 0–100% RH (non-condensing) |
| Minimum Detectable Load | 0.1 mg |
| Maximum Load Capacity | 4 mg |
| Power Supply | Rechargeable Li-ion battery pack |
| Compliance | NIOSH TC-74CPDM-02, MSHA 18-A140015-0, PA BFE 2-15, 30 CFR Part 74, EN 61326-1:2005, FCC Part 15 Subpart B, UN 3480 (Li-ion transport) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | pDR-1500 |
| Measurement Principle | Optical Light Scattering (880 nm IR) with Gravimetric Calibration Capability |
| Measured Parameters | PM₁₀, PM₂.₅ (with optional cyclone cutters) |
| Measurement Range | 0.001–400 mg/m³ (auto-ranging) |
| Sampling Flow Rate | 1.0–3.5 L/min |
| Minimum Detectable Concentration | 0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Flow Stability | ±5% of reading (traceable to SAE test protocols) |
| Resolution | 0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Accuracy | ±5% of reading (traceable to SAE standards) |
| Precision | ±2% of reading or ±0.005 mg/m³ (1-s avg) |
| Scattering Coefficient Range | ~1.5×10⁻⁶–0.6 m⁻¹ @ λ = 880 nm |
| Aerodynamic Particle Size Range | 1–10 µm |
| Optical Detection Angle | 90° |
| RH Compensation | Built-in relative humidity correction algorithm |
| Operating Temperature | –10°C to +50°C |
| Storage Temperature | –20°C to +70°C |
| Humidity Range | 10–95% RH (non-condensing) |
| Data Logging Interval | 1 s to 1 h |
| Total Memory Capacity | >500,000 data points |
| Power Supply | Internal rechargeable Li-ion battery (≥12 h field operation) + external DC input |
| Connectivity | Wi-Fi 802.11 b/g/n, iOS/Android mobile app support |
| Physical Dimensions | 181 mm (H) × 143 mm (W) × 84 mm (D) |
| Weight | 1.2 kg |
| Filter Medium | 37 mm glass fiber filter (for gravimetric validation) |
| Flow Control | Active volumetric flow control with linear flow path design |
| Inlet Configuration | Helical inlet for representative sampling without cyclone |
| Zero Calibration | Integrated HEPA-filtered zero air source |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | pDR/ADR-1500 |
| Measurement Principle | Nephelometric Light Scattering (880 nm LED) |
| Measured Parameter | PM₂.₅ (also configurable for PM₁, PM₄, PM₁₀ via interchangeable cyclones) |
| Flow Control | True Volumetric Flow Control with Digital Pressure Feedback |
| Humidity Compensation | Integrated Heated RH Sensor & Algorithmic Correction |
| Compliance | NIOSH Methods 0500 & 0600, ACGIH-Traceable Cyclones |
| Data Storage | >500,000 records |
| Display | Dual-line LCD (16×2 characters) |
| Dimensions (pDR-1500) | 181 × 143 × 84 mm |
| Dimensions (ADR-1500) | 533 × 431 × 215 mm |
| Weight (ADR-1500) | 12.9 kg |
| IP Rating | IP65 (ADR-1500) |
| Power Options | AC, DC, or Internal Rechargeable Battery |
| Communication Interfaces | USB, RS-232, 0–2 V / 4–20 mA Analog Outputs, Optional Wireless Module |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | PM CEMS |
| Measurement Principle | Dual-Method (Beta Attenuation + Tapered Element Oscillating Microbalance, TEOM™) |
| Measured Parameter | Particulate Matter Mass Concentration (PM₁₀, PM₂.₅, or Total Suspended Particulates) |
| Range | 0–250 mg/m³ |
| Accuracy | ±20% (uncorrected), ±10% (source-corrected) |
| Detection Limit | 0.25 mg/m³ (15-min integration) |
| Response Time (T₉₀) | 15 min |
| Operating Flue Gas Temperature | ≤200 °C |
| Ambient Operating Temperature (Controller) | 4–50 °C |
| Power Supply | 200–240 VAC, 50/60 Hz, 30 A |
| Instrument Air | 80 slpm at 0.55–0.7 MPa (75–100 psi) |
| Probe Dimensions | 1117.85 mm W × 914/1524 mm L (sheath length options) × 474.73 mm H × 307.09 mm D |
| Probe Weight | 59 kg (130 lbs) |
| Controller Dimensions | 482.6 mm W × 218.95 mm H × 655.32 mm D |
| Controller Weight | 25 kg (55 lbs) |
| Analog Outputs | 6 voltage (0–100 mV, 1/5/10 V), 6 current (0–20 mA, 4–20 mA) |
| Digital/Relay Outputs | 1 power-fail alarm, 10 configurable relay outputs |
| Compliance | EPA PS-11, QA Procedure 2, Method 5/17 verified |
| Calibration Traceability | NIST-traceable mass reference |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Thermo |
| Pricing | Upon Request |
| Brand | Thermo Scientific |
|---|---|
| Model | SCR-CEMS |
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Instrument Type | Flue Gas Continuous Emission Monitoring System (CEMS) |
| Measurement Parameters | NH₃, NO, NO₂, NOₓ, O₂ |
| Dilution Ratio | Fixed 100:1 (adjustable via calibrated sonic orifice) |
| Dilution Air Supply Requirement | 0.6 MPa, ≥20 L/min |
| Sample Flow Rate | 50–300 mL/min (typ. 50 mL/min) |
| NH₃ Conversion Furnace | Integrated within probe head |
| Probe Material | Hastelloy C-276 / Inconel 625 (corrosion-resistant high-temp alloy) |
| Compliance | EPA Performance Specification 15 (PS-15), EN 15267-3, ISO 14956, US EPA Method 7E, ASTM D6522 |
| Software | Thermo Scientific™ CEMS Pro v5.x with 21 CFR Part 11-compliant audit trail and GLP/GMP data integrity features |
| Data Output | 4–20 mA analog, Modbus TCP/IP, OPC UA, FTP/SCP |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405 |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Measured Parameter | PM₂.₅ |
| Regulatory Designation | U.S. EPA Equivalent Method for PM₁₀ (EQPM-1090-079) |
| Operating Temperature Range (Sample Gas) | −40 °C to +60 °C |
| Enclosure Operating Temperature | 2 °C to 40 °C |
| Full-Scale Range | 0–1,000,000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy (Mass Measurement) | ±0.75% |
| Precision | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Data Averaging Intervals | 10 s to 3600 s (default: 10 min) |
| Long-term | 30 min, 1 h, 8 h, 24 h |
| Sampling Flow Rate | 3 L/min (main), 13.67 L/min (bypass) |
| Data Output Frequency | Every 2 seconds |
| Analog Outputs | 8 configurable (0–1 V or 0–5 V DC) |
| Digital I/O | 2 relay alarms, 4 analog inputs (0–5 V DC, user-scaled) |
| Communication Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Internal Data Storage | 500,000 records |
| Filter Medium | Pallflex TX40, 13 mm effective diameter |
| Power Requirements | Instrument: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum Pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 425 mm × 475 mm × 738 mm |
| Weight | 18 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TEOM 1405-D |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM™) |
| Measured Parameters | PM₁₀, PM₂.₅, and PM<sub>coarse</sub> (PM₁₀ − PM₂.₅) |
| Data Averaging Intervals | 10 s to 24 h |
| Mass Concentration Range | 0–1,000,000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Mass Measurement Uncertainty | ±0.75% |
| Sampling Flow Rates | Fine channel: 3.0 L/min |
| Coarse channel | 1.67 L/min |
| Bypass | 12.0 L/min |
| Operating Ambient Temperature | −40 °C to +60 °C (sensor/control unit maintained at 2–40 °C) |
| Communication Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Analog I/O | 8 configurable 0–1 V or 0–5 V outputs |
| Power Requirements | Main unit: 100–240 VAC, 440 VA, 47–63 Hz |
| Vacuum pump | 120 VAC/60 Hz (4.25 A) or 240 VAC/50 Hz (2.25 A) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 73.8 in (1080 mm × 1207.5 mm × 1875 mm) |
| Weight | 18 kg |
| Compliance | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Model | TEOM 1405-F |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) with Filter Dynamic Measurement System (FDMS) |
| Measured Parameters | PM₁₀ and PM₂.₅ |
| Regulatory Designation | U.S. EPA Equivalent Method for PM₂.₅ (EQPM-0609-181) |
| Operating Temperature Range | -40 °C to +60 °C (sample gas) |
| Flow Rates | Main flow = 3.0 L/min |
| Mass Resolution | 0.1 µg/m³ |
| Accuracy | ±2.0 µg/m³ (1-hr average), ±1.0 µg/m³ (24-hr average) |
| Mass Measurement Uncertainty | ±0.75% (NIST-traceable) |
| Data Output Interval | Configurable from 10 seconds to 24 hours |
| Default | 6-minute update of 1-hr and 24-hr rolling averages |
| Data Storage Capacity | 500,000 records |
| Communication Interfaces | Ethernet, USB, RS-232, RS-485, FTP server |
| Analog I/O | 8 configurable analog outputs (0–1 V or 0–5 V DC), 4 analog inputs (0–5 V DC), 2 relay alarms |
| Power Requirements | 100–240 VAC, 440 VA, 47–63 Hz (main unit) |
| Dimensions (W×D×H) | 42.5 in × 47.5 in × 137.8 in (1080 mm × 1207.5 mm × 3500 mm) |
| Weight | 33 kg |
| Safety Certifications | CE (EN 61326, EN 61010-1), UL 61010-1:2004, CSA C22.2 No. 61010-1:2004, FCC Part 15 Subpart B Class B |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Category | Imported |
| Model | TEOM 1405-F |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Regulatory Designation | U.S. EPA Equivalent Method for PM2.5 (EQPM-0609-181) |
| Particle Size Fractions | PM2.5, PM10, PM1, TSP |
| Data Interfaces | Ethernet, USB, RS232, RS485, FTP Server |
| User Interface | Touchscreen LCD |
| Flow Control | Activol™ Dynamic Mass Flow Control |
| Integrated System | Filter Dynamic Measurement System (FDMS), Sensor Module, and Control Unit in Single Enclosure |
| Environmental Compensation | Heated Sample Inlet with Relative Humidity and Temperature Regulation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Thermo Scientific TEOM 1405DF / 1405F |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅, TSP, PM₁.₀ |
| Measurement Range | 0–1,000,000 µg/m³ |
| Detection Limit | 0.1 µg/m³ |
| Sampling Flow Rate | 3 L/min (main), 12–13.67 L/min (bypass) |
| Flow Stability | ±75% for mass measurement |
| Data Storage Capacity | 5,000,000 records |
| Reporting Interval | 6-minute updates with 1-hour rolling averages |
| Accuracy | ±2.0 µg/m³ (1-hr avg), ±1.0 µg/m³ (24-hr avg) |
| Resolution | 0.1 µg/m³ |
| Calibration Traceability | NIST-traceable mass and flow standards |
| Compliance | Designed to meet U.S. EPA Reference Method EQPM-0899-007 (PM₂.₅), EQPM-0899-008 (PM₁₀), ISO 20581, and applicable EN 12341 requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model Series | Thermo Scientific TEOM |
| Measurement Principle | Tapered Element Oscillating Microbalance (TEOM) |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Measurement Range | 0–1,000,000 µg/m³ |
| Measurement Interval | Real-time mass measurement with 6-minute data updates and 1-hour rolling averages |
| Sample Flow Rate | 3 L/min (1405F) |
| Fine-mode flow | 3 L/min / Coarse-mode flow: 1.67 L/min (1405DF) |
| Detection Limit | 0.1 µg/m³ |
| Flow Stability | ±75% during mass measurement |
| Data Storage Capacity | 5,000,000 records |
| Accuracy | ±2.0 µg/m³ (1-hr average), ±1.0 µg/m³ (24-hr average for 1405F) |
| Resolution | 0.1 µg/m³ |
| Bypass Flow | 12 L/min (1405DF), 13.67 L/min (1405F) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Continuous Emission Monitoring System (CEMS) |
| Model | TRS CEMS |
| Measurement Principle | Thermal Oxidation + Pulsed Fluorescence SO₂ Detection |
| Detection Targets | H₂S, CH₃SH, CH₃SCH₃, CH₃SSCH₃, CS₂, COS (reported as SO₂-equivalent concentration) |
| Dilution Ratio | 20:1 to 200:1 |
| Sample Flow Rate | 400–800 cc/min |
| Oxidation Furnace Max Temp | 1093 °C |
| SO₂ Scrubber Efficiency | >99.9% |
| Detection Limit | 0.5 ppb (300-sec avg) |
| Accuracy | ±1% of reading or ±1 ppb |
| Response Time (T₉₀) | 80 s |
| Zero Drift (24 h) | <1 ppb |
| Span Drift (24 h) | ±1% FS |
| Operating Temperature Range | 0–45 °C (analyzer), –40–50 °C (probe) |
| Output Options | 4–20 mA (isolated, optional), RS232/RS485, TCP/IP, 10 status relays |
| Compliance | Designed for EPA Method 15/16A, ASTM D5502, ISO 14687, and supports 21 CFR Part 11 audit trail requirements in configured software mode |