Gas Detector
Filter
Showing 2341–2370 of 2968 results
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | IMPACT |
| Flow Rate | 10 L/min |
| Cut-Point Options | 2.5 µm (PM₂.₅) or 10 µm (PM₁₀) |
| Impactor Stage | Single-stage inertial impactor |
| Collection Media | 37 mm pre-oiled porous plastic impaction disc + 47 mm filter (quartz/PTFE) |
| Dimensions | 7 cm (D) × 5 cm (H) × 10 cm (L) |
| Weight | 0.23 kg |
| Material | Anodized aluminum inlet with brass barbed fitting for 3/8" ID tubing |
| Patented Design | US Patent No. 7,334,453 |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | IMPACT |
| Flow Rate | 10 L/min |
| Filter Diameter | 47 mm |
| Compatible Pump | Leland Legacy (recommended) |
| Sampling Target | PM₁₀, PM₂.₅, and PM₁₀–₂.₅ fractionated collection |
| Impact Substrate | Pre-oiled disposable impaction plate |
| Design | Removable filter holder, rain shield optional, rapid-mount bracket optional |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Impingers |
| Pricing | Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | IOM |
| Sampling Flow Rate | 2 L/min |
| 50% Cut-Point | 100 µm (at 2 L/min) |
| Filter Diameter | 25 mm |
| Housing Material | Heat-resistant polypropylene (plastic) or stainless steel |
| Max Operating Temperature | 100 °C (plastic), 200 °C (stainless steel) |
| Weight | <55 g (plastic version, including cassette) |
| Dimensions | 8.5 × 2.8 cm |
| Inlet Tubing ID | 6.25 mm (1/4″) |
| Compliance | ACGIH Inhalable Fraction, ISO/CEN EN 13205, HSE MDHS 14/4, MDHS 6/3 (with accessory head), MDHS 25/3 (stainless only), NIOSH Method 5700, OSHA PNOR, Australian Inhalable PM Standard |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Leland Legacy |
| Flow Range | 5–15 L/min |
| Constant Flow Accuracy | ±5% of setpoint |
| Battery Runtime | ≥24 h at 5 L/min (typical) |
| Data Logging | Yes (start/end time, volume, temperature, barometric pressure, pump status) |
| Noise Level | 62.5 dB (bare pump), 52 dB (with optional noise-reduction enclosure, 224-89) |
| Operating Temperature | 0–45 °C |
| Dimensions | 20.0 × 10.0 × 7.0 cm |
| Weight | 1000 g |
| Enclosure | ESD-safe thermoplastic with rubber overmold and integrated belt clip |
| Power | Rechargeable Li-ion battery |
| Timer Range | 1–99999 min (up to 69 days) |
| Flow Compensation | Automatic restart on blockage |
| Built-in particle trap | Yes |
| Compliance | CE-marked per EU directives |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | OVS |
| Tube Dimensions | 138 mm × 7.5 mm OD |
| Flow Rate | 1 L/min (typical) |
| Analytical Compatibility | GC or HPLC |
| Adsorbent Configurations | Dual-bed (e.g., XAD-2 270/140 mg, Tenax, Silica Gel, XAD-7) |
| Filter Type | Glass fiber (G), PTFE (T), Quartz (Q), Foam (F) |
| Storage Requirement | Refrigerated or frozen |
| Compliance | Designed for OSHA, NIOSH, and EPA sampling methods |
| Packaging | Individually sealed in inert, low-background packaging |
| Shelf Life | Limited — refer to lot-specific expiration date |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | PEM |
| Flow Rates | 2, 4, or 10 L/min |
| Filter Diameter | 37 mm |
| Compliance | EPA Method IP-10A |
| Recommended Pumps | AirChek TOUCH (220–5000TC) for 2 & 4 L/min |
| Filter Type | PTFE membrane |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | PMI |
| Flow Rate | 3 L/min |
| Cut-Point Options | 2.5 µm (PM₂.₅), 10 µm (PM₁₀), or 2.5–10 µm (PM Coarse) |
| Housing Material | Precision-machined aluminum (inlet), PVC (exhaust), Delrin® filter cassette with stainless steel support mesh |
| Impactor Substrate | 25 mm pre-oiled porous plastic disc (disposable, reduces particle bounce) or optional 25 mm filter for chemical analysis |
| Final Filter | 37 mm diameter, media-dependent (e.g., PVC, PTFE, quartz, Teflon) |
| Dimensions (w/o clamp) | 2 in (5.1 cm) dia × 1 in (2.6 cm) H |
| Weight | 2.5 oz (70.9 g) |
| Inlet Tubing ID | 1/4 in |
| Patented Design | US Patent No. 7,334,453 |
| Compliance | EPA-defined PM₂.₅ and PM₁₀ size-selective sampling per 40 CFR Part 53 and ISO 7708 |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | PMI Series |
| Flow Rate | 3 L/min |
| Cut-Point | 10 µm (PM₁₀) or 2.5 µm (PM₂.₅) |
| Filter Diameter | 37 mm |
| Impactor Substrate | 25 mm disposable pre-oiled porous plastic disk |
| Weight | 71 g |
| Compliance | EPA-defined PM₂.₅ and PM₁₀ sampling criteria |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Pocket Pump TOUCH (220-1000TC) |
| Flow Range | 20–500 mL/min (constant-flow mode) |
| Backpressure Compensation | Up to 20 in. H₂O |
| Flow Stability | ±5% of setpoint or ±3 mL/min, whichever is greater |
| Flowmeter Accuracy | ±0.5% of reading |
| Operating Time | ≥20 hours at maximum flow and backpressure |
| Power Source | Rechargeable Li-ion battery (3.6 V, 2.6 Ah) |
| Dimensions | 8.1 × 9.7 × 3.8 cm |
| Weight | 235 g |
| Ingress Protection | IP64 |
| Certifications | CE, UL Intrinsically Safe |
| Brand | SKC |
|---|---|
| Origin | USA |
| Product Line | Porapak Series |
| Tube Dimensions (OD × Length) | 6 mm × 40–110 mm |
| Sorbent Mass | 35–175 mg per section |
| Dual-Bed Configuration | Yes (e.g., 88/44 mg, 100/50 mg, 150/75 mg) |
| End Caps | Glass Wool or Polyethylene Frit |
| Separator | Stainless Steel or Glass |
| Packaging | Individually sealed in foil pouches, 10 tubes per pack |
| Part Numbers | 50226-59-01, 50226-114, 50226-115, 50226-59-03, 50226-59-04, 50226-116A |
| Compliance | Compatible with EPA Methods TO-1, TO-2, TO-14A, TO-15, and ISO 16017-1 |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | PUF Tube |
| Compliance | EPA TO-10A, EPA IP-8, ASTM D4861, ASTM D4947, ASTM D6209, EPA IP-7, EPA TO-4A, TO-9A, TO-13A, EPA Method 600/8-80-038 |
| Dimensions (Small) | 22 mm OD × 100 mm L |
| Dimensions (Large) | 65 mm OD × 125 mm L |
| Flow Rate Range (Small) | 1–5 L/min |
| Sampling Duration (Small) | Up to 24 h |
| Adsorbent Configuration | Pure PUF, PUF/Glass Fiber, PUF/Tenax/PUF, PUF/XAD-2/PUF |
| Pre-cleaned Adsorbent | Yes |
| Background Performance | Low-blank, solvent-rinsed |
| Packaging | Individually sealed in inert foil pouches |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | QT30 / QuickTake 30 |
| Sampling Method | Six-Stage Andersen Impaction |
| Collection Efficiency | ≥98% |
| Operating Noise | ≤60 dB(A) |
| Power Supply | Rechargeable Li-ion Battery (5 h runtime) or AC/DC Adapter |
| Sampling Duration | 0–999 min adjustable |
| Petri Dish Size | 90 mm standard |
| Weight | 2.2 kg |
| Dimensions (Sampler) | 23.6 × 21.3 × 8.9 cm |
| Flow Calibration Device | SKC 4046 Digital Flow Calibrator |
| Flow Range | 2.5–300 L/min |
| Flow Accuracy | ±2% of reading or ±0.05 STD L/min (whichever is greater) |
| 4046 Dimensions | 183 × 64 × 53 mm |
| 4046 Power | 7.5 VDC ±1.5 V, peak current 300 mA |
| Manual Elevating Platform | max height 3 m, dual tray options (47×37 cm and 42×32 cm), aluminum construction with anti-slip rubber surface |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | SamplePro FlexFilm |
| Material | Proprietary low-adsorption polymer film |
| Max Operating Temperature | 60°C (140°F) |
| VOC Background | Lower than Tedlar® |
| VOC Stability | Equivalent to Tedlar® |
| Compatible Gases | VOCs, CO, CO₂, CH₄, SF₆, VSCs |
| Volume Range | 0.5 L to 100 L |
| Fitting Options | Single polypropylene valve/septum or dual stainless steel valves |
| Sterility | Non-sterile, single-use only |
| Compliance | Designed for EPA Method TO-15, ASTM D5466, ISO 16000-6, and OSHA ID-253 sampling protocols |
| Brand | SKC |
|---|---|
| Origin | USA |
| Type | Imported Gas Sampling Sorbent Tube |
| Model | Silica Gel Sorbent Tube |
| Compliance | NIOSH, OSHA, ASTM, EPA Methods |
| Key Dimensions | 6–10 mm OD × 70–210 mm Length |
| Adsorbent Mass Range | 100–3750 mg per segment |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Sioutas Impactor |
| Flow Rate | 9 L/min |
| Cut Points | 2.5 µm, 1.0 µm, 0.5 µm, 0.25 µm |
| Collection Substrate | 25 mm PTFE filters (stages 1–4), optional 37 mm backup filter (<0.25 µm) |
| Pressure Drop | Low at 9 L/min for 24-h sampling |
| Compliance | Designed for OSHA, NIOSH, and ISO 7708-compliant personal aerosol monitoring |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | SWYPEs |
| Type | Single-use, compound-specific colorimetric surface and skin wipe indicator for workplace chemical contamination detection |
| Compliance | Designed for OSHA, NIOSH, and ACGIH exposure assessment workflows |
| Intended Use | Qualitative on-site detection of surface-resident and dermal chemical residues (e.g., aldehydes, amines, hydrazines, organophosphates, heavy metal ions) |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Tedlar |
| Material | DuPont™ Tedlar® Polyvinyl Fluoride (PVF) Film |
| Thickness | 2 mil (50.8 µm) |
| Temperature Range | -72°C to +107°C |
| VOC Recovery | ≥80% after ≥48 hours |
| Compliance | EPA Method TO-14A, TO-15, and TCLP-compatible |
| Fitting Options | Single polypropylene inlet/outlet or dual stainless steel valves |
| Volume Options | 1 L, 3 L, 5 L |
| Base Contamination | Ultra-low VOC background |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Tenax |
| Type | Thermal Desorption Sorbent Tube for Volatile Organic Compounds (VOCs) Sampling |
| Compliance | NIOSH 1501, OSHA ID-259, ASTM D6196, EPA TO-17, IP-1B |
| Adsorbent Options | Tenax TA (poly(2,6-diphenyl-p-phenylene oxide)), Tenax GR (graphitized carbon black–Tenax composite) |
| Tube Dimensions | 6 mm × 70 mm to 16 mm × 125 mm |
| Adsorbent Mass Range | 20 mg to 11.6 g per bed |
| Construction | Stainless steel (SS) or glass (GS) tube body with precision-sieved adsorbent beds and optional backup layer |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vac-U-Chamber |
| Pricing | Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | VOC Chek 575 |
| Instrument Type | Portable |
| Compliance | ASTM D6246-08, ANSI/ISEA 104-1998 (R2009) |
| Sampling Principle | Diffusion-based passive collection |
| Target Analytes | Benzene, toluene, xylene (BTX), ethylbenzene, perchloroethylene, trichloroethylene, methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), styrene, butyl acetate, ethylene oxide (specialized variant), methanol (specialized variant) |
| Adsorbent Options | Activated charcoal, Carbopack™ X, Carbograph™ 1TD, and other SKC-certified sorbents |
| Validated Exposure Durations | 15 min–24 h (compound- and configuration-dependent) |
| Reporting Limit Compatibility | GC-FID, GC-MS, HPLC-UV |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEMS-V100 |
| Price Range | USD 42,000–70,000 (FOB) |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ≤±5% F.S. (range >200 μmol/mol) |
| Repeatability | RSD ≤3% |
| Response Time | <5 min |
| Stability | ≤20% (emission standard ≥100 μmol/mol) |
| Analytes | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Total Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes), Volatile Organic Compounds (VOCs) |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Detection Range | 0–50 / 500 / 5000 ppm (as CH₄, adjustable) |
| LOD | 0.05 ppm (0–50 ppm range) |
| Zero Drift | ±1% F.S. or 0.1 ppm |
| Span Drift | ±1% F.S. or 0.1 ppm |
| Analysis Cycle | 1 min (standard) |
| Sample Flow Rate | 600 mL/min (analysis) |
| Calibration Interval | User-configurable (e.g., daily, weekly, monthly) |
| Output Interface | Modbus TCP, 4–20 mA, RS232, RS485 |
| Operating Environment | 0–45 °C, <90% RH (non-condensing) |
| Storage | −20–60 °C, <90% RH |
| Required Gases | High-purity H₂, zero-air, N₂, CH₄ calibration gas |
| Power Supply | 220 V AC, 50/60 Hz, 1500 W |
| Enclosure | 19″ rack-mount industrial cabinet |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CEMS-X100 |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Accuracy | ±10% |
| Repeatability | ≤2% |
| Response Time | As low as 5 minutes (dependent on flue gas conditions) |
| Long-term Stability | ≤5% |
| Measurable Elements | Pb, Cu, Cd, Cr, Zn, Ni, and over 20 other heavy metals |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | EAD-100 Series |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Measurement Principle | Optical Light Scattering |
| Measured Parameters | PM₁₀, PM₂.₅ |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | EAQM-100S |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Measured Parameters | SO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀, Temperature, Relative Humidity, Wind Speed, Wind Direction, Atmospheric Pressure, TVOC |
| Measurement Principles | Optical Scattering (PM), Electrochemical Sensors (CO, NO₂, SO₂, O₃), Photoionization Detection (TVOC), Capacitive/Thermal Hygrometry & Thermistor-based Temperature Sensing, Ultrasonic Anemometry (Wind), Piezoresistive Barometry |
| Calibration | Dual-mode (Automated Zero/Span Drift Compensation + Manual Field Calibration via Remote Command) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | EPM-100 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Measurement Principle | Beta-ray Absorption (C-14 source) |
| Safety Classification | Non-explosion-proof |
| Measurement Range | 0–20 mg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ±20% (full scale) |
| Relative Error | ≤20% |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | EPM-2050 |
| Price Range | USD 21,000 – 35,000 (FOB) |
| Measurement Method | Beta-ray Absorption (β-ray) |
| Measured Parameters | PM₂.₅, PM₁₀, TSP |
| Radioisotope Source | Carbon-14 (¹⁴C), Activity ≤ 100 µCi |
| Detection Limit | ≤ 2 µg/m³ (24-hr avg) |
| Concentration Range | 0–1000 µg/m³ or 0–10,000 µg/m³ |
| Resolution | 0.1 µg/m³ |
| Accuracy | ≤ ±5% (24-hr avg) |
| Flow Rate | 16.67 L/min (±2% stability) |
| Measurement Cycle | Adjustable, ≤ 60 min |
| Parallelism | ≤ ±10% |
| Display Interval | Default 1 hr, user-configurable |
| Operating Temp. (Analyzer) | 15–40 °C |
| Operating Humidity | ≤ 90% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Dimensions (L×W×H) | 417 × 483 × 382 mm |
| Weight | 25 kg (analyzer), 7.5 kg (pump) |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EVOCs-1000 |
| Pricing | Available Upon Request |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EVOCs-2000 |
| Detection Principle | Gas Chromatography with Flame Ionization Detection (GC-FID) |
| Instrument Type | Online Analytical System |
| Typical Configuration | Dual-Channel GC-Based VOC Analyzer (C₂–C₅ and C₆–C₁₂) |
| Measurement Range | Quantitative analysis of ≥57 speciated VOCs per HJ 1010–2018 |
| Resolution | Peak resolution ≥1.0 for critical pairs — cyclopentane/isopentane, 2,3-dimethylpentane/2-methylhexane, and o-xylene/styrene |
| Accuracy | ±10% relative to certified reference standards |
| Brand | SkyRay Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | TVOC-800 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Portable |
| Typical Configuration | TVOC Analyzer |
| Detection Range | 0–20 / 200 / 1000 ppm (field-selectable) |
| Resolution | ≤10 ppb |
| Accuracy | ≤±10% of Full Scale |
| Response Time | ≤20 s |