| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 3163 |
| Detection Principle | Heated Diode (HD) Sensor |
| Sensitivity | 4 g/year (0.15 oz/yr) |
| Detectable Refrigerants | R22, R134a, R404A, R410A, R507, R438A, and all CFCs, HCFCs, HFCs |
| Operating Temperature | −18 °C to +50 °C |
| Storage Temperature | 0 °C to +50 °C |
| Relative Humidity Range | 20–80 % RH |
| Weight | 500 g (incl. batteries) |
| Dimensions | 270 × 60 × 61 mm |
| Power Supply | 2 × D-cell batteries |
| Battery Life | ~16 h continuous operation |
| Sensor Lifetime | 80–100 h (approx. 1 year under typical field use) |
| Compliance | EN 14624:2012, SAE J1627, EU Regulation (EC) No 842/2006 & (EU) No 517/2014 (F-gas Regulation) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0563 3164 |
| Detection Sensitivity | <3 g/year (per EN 14624:2012) |
| Detectable Refrigerants | R134a, R22, R404A, H₂, CFCs, HCFCs, HFCs (NH₃ requires optional probe) |
| Operating Temperature | -20 °C to +50 °C |
| Relative Humidity Range | 20–80 % RH |
| Response Time | <1 s |
| Warm-up Time | <50 s |
| Weight | 348 g |
| Dimensions (L×W×H) | 190 × 57 × 42 mm |
| Gooseneck Length | 370 mm |
| Battery | Integrated NiMH pack (6 cells), ~6 h continuous operation |
| Storage Temperature | -25 °C to +70 °C |
| Alarm Type | Visual (LED color shift: green → red) and audible (adjustable tone) |
| Compliance | EN 14624:2012 |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 320 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±2 ppm (0–39.9 ppm CO) |
| Repeatability | ±5% of reading (40–500 ppm CO) |
| Response Time | < 40 s |
| Stability | ±5% of reading (40–500 ppm CO) |
| Measured Gases | O₂, CO |
| Compliance | EN 50379-1 to -3, 1st BImSchV, TÜV-certified |
| Included Sensors | Integrated O₂ sensor, built-in CO sensor, combustion air temperature sensor, thermocouple input in probe connector |
| Optional Accessories | Multi-hole probe, flexible flue gas probe, differential pressure probe |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 320 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Range (O₂) | 0–21 % vol |
| Measurement Range (CO) | 0–500 ppm |
| Accuracy (O₂) | ±0.2 % vol |
| Accuracy (CO) | ±2 ppm (0–39.9 ppm), ±5 % of reading (40–500 ppm) |
| Repeatability | ±5 % of reading (40–500 ppm) |
| Response Time (t₉₀) | < 40 s |
| Stability | ±5 % of reading (40–500 ppm) |
| Operating Temperature | –5 to +45 °C |
| Display | Backlit graphical LCD |
| Power Supply | Rechargeable Li-ion battery (up to 6 h operation) |
| Compliance | EN 50379-1, EN 50379-2, EN 50379-3, 1st BImSchV, TÜV-certified |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 330-1LL |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy (O₂/CO) | ±0.2 vol.% |
| Repeatability | ±0.2 vol.% |
| Stability | ±0.2 vol.% |
| Response Range (O₂) | 0–21 vol.% |
| Measured Gases | O₂, CO (H₂-compensated), CO₂, NO |
| Display | High-Resolution Color Graphic LCD |
| Battery Life | Up to 6 hours (removable Li-ion) |
| Sensor Lifetime | Up to 6 years (O₂ and CO sensors) |
| Data Logging | Continuous curve recording with time-stamped measurement data |
| Probe Interface | Modular probe system with secure locking mechanism |
| Compliance | Designed for EN 50379-1, EN 50379-2, and applicable EU emission monitoring directives |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 330-2 |
| Instrument Type | Portable Flue Gas Analyzer |
| O₂ Measurement Range | 0–21 vol.% |
| O₂ Accuracy | ±0.2 vol.% |
| CO Measurement (H₂-compensated) | 0–8,000 ppm |
| CO Accuracy | ±10 ppm or ±10% of reading (0–200 ppm), ±20 ppm or ±5% (201–2,000 ppm), ±10% (2,001–8,000 ppm) |
| NOlow Range | 0–300 ppm |
| NOlow Accuracy | ±2 ppm (0–39.9 ppm), ±5% of reading (40–300 ppm) |
| Response Time (t₉₀) | <60 s for CO, <40 s for O₂/CO₂, <30 s for NO/NOlow |
| Pressure Measurement Range | 0–300 hPa |
| Vacuum/Overpressure Range | −9.99 to +40 hPa |
| Data Storage Capacity | 500,000 readings |
| Display | Color graphic LCD (240 × 320 pixels) |
| Weight | 600 g (without battery) |
| Dimensions | 270 × 90 × 65 mm |
| Operating Temperature | −5 °C to +45 °C |
| Flue Gas Temperature Range | −20 °C to +50 °C |
| Battery | Rechargeable Li-ion, 3.7 V / 2.6 Ah |
| Power Supply | 6 V / 1.2 A adapter |
| Compliance | EN 50379-2, 1st BImSchV, TÜV-certified for O₂, °C, hPa and H₂-compensated CO measurement |
| Warranty | 3 years on O₂/CO/CO-H₂ sensors |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3341 |
| Instrument Type | Portable Flue Gas Analyzer |
| Differential Pressure Accuracy | ±0.5 hPa (–49.9 to +49.9 hPa) |
| Repeatability | < 2 % |
| Response Time | < 20 s |
| Stability | ±1.5 % of reading (remaining pressure range) |
| Measured Gases | CO, COlow, NO, NOlow, NO₂, SO₂ (CO-interference-resistant SO₂ sensor up to 10,000 ppm CO) |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 340 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5% (gas readings) |
| Repeatability | ≤2% |
| Response Time | <20 s (O₂), <30–40 s (CO, NO, NO₂, SO₂, COlow, NOlow) |
| Stability | ≤5% over 2 h |
| Measurable Gases | CO, COlow, NO, NOlow, NO₂, SO₂, O₂, differential pressure, absolute pressure, flue gas temperature, combustion efficiency, flue gas loss, dew point, CO₂ (calculated) |
| Differential Pressure Range | −200 to +200 hPa |
| O₂ Range | 0–25 vol.% |
| CO Range | 0–10,000 ppm |
| COlow Range | 0–500 ppm |
| NO Range | 0–4,000 ppm |
| NOlow Range | 0–300 ppm |
| NO₂ Range | 0–500 ppm |
| SO₂ Range | 0–5,000 ppm |
| Temperature Range | −40 to +1200 °C |
| Operating Temperature | −5 to +50 °C |
| Battery Life | >6 h (pump on, backlight off, 20 °C) |
| Weight | 960 g |
| Dimensions | 283 × 103 × 65 mm |
| Enclosure | TPE/PC, IP40 |
| Display | Graphic LCD, 160 × 240 pixels |
| Power | Rechargeable Li-ion battery (3.7 V / 2.4 Ah) + external adapter (6.3 V / 2 A) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 340 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5% (gas sensors), ±0.5 hPa (differential pressure, -49.9 to +49.9 hPa) |
| Repeatability | ≤2% |
| Response Time | <20 s (O₂), <30–40 s (CO, NO, NO₂, SO₂, COlow, NOlow) |
| Stability | ≤5% |
| Measured Gases | CO, COlow, NO, NOlow, NO₂, SO₂, O₂, differential pressure, flue gas temperature, ambient temperature, draft, efficiency, flue gas loss, dew point, CO₂ (calculated) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | testo 340 |
| Pricing | Upon Request |
| Display | Graphical, 160 × 240 pixels |
| Operating Temperature | −5 to +50 °C |
| Storage Temperature | −20 to +50 °C |
| Weight | 960 g |
| Standard Sensors | O₂, Differential Pressure / Flow Velocity |
| Sensor Slots | 3 configurable (O₂ pre-installed |
| Expandable Range | Single-sensor or full-sensor range extension option |
| Pump | Automatic flow-controlled sampling pump |
| Data Logging | Internal memory |
| Connectivity | USB interface for easyEmission PC software (optional) |
| Fuel Library | 10 preloaded + 10 user-defined fuels |
| Compliance | Designed for EN 50379-1/2, DIN EN 15548-1, VDI 3862, and applicable EU emission monitoring directives |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3520 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measured Gases | CO, CO₂, NO, NO₂, SO₂, O₂ (standard), optional H₂S, CₓHᵧ, and infrared CO₂ |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3520 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measurable Gases | CO, CO₂, NO, NO₂, SO₂, H₂S, and CₓHᵧ |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3521 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measurable Gases | CO, CO₂, NO, NO₂, SO₂, H₂S, CₓHᵧ |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy (Gas Sensors) | ±5% of reading (typical, per ISO 12039 & EN 15267-3) |
| Response Time (t₉₅) | 20 s |
| Detection Gases (Configurable) | O₂, CO, NO, NO₂, SO₂, H₂S, CₓHᵧ, CO₂ (NDIR) |
| Operating Temperature | −5 °C to +45 °C |
| Storage Temperature | −20 °C to +50 °C |
| Weight | 440 g |
| Dimensions | 88 × 38 × 220 mm |
| Data Memory | 2 MB (up to 250,000 measurement values) |
| Battery Life | Up to 5 h (without wireless transmission) |
| Protection Class | IP40 |
| Temperature Probe Compatibility | K-type (−200 °C to +1370 °C), S-type (0 °C to +1760 °C), ambient probe (−20 °C to +50 °C) |
| Flow Velocity Range | 0–40 m/s |
| Dew Point Calculation Range | 0–99.9 °Ctd |
| O₂ Measurement (Electrochemical) | 0–25 Vol.% (±0.2 Vol.% accuracy) |
| CO Measurement (Electrochemical, H₂-compensated) | 0–10,000 ppm (±5% rdg or ±10 ppm, whichever greater) |
| CO₂ Measurement (NDIR) | 0–50 Vol.% (±0.3 Vol.% at 0–25 Vol.%, ±0.5 Vol.% at >25 Vol.%) |
| Optional Modules | Peltier gas conditioning unit, automatic condensate removal pump, fresh air valve (5× range extension), single-channel range extender (0×/2×/5×/10×/20×/40×), 11–40 V DC input, integrated flow sensor with auto-zero pressure compensation |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | testo 350 |
| Pricing | Upon Request |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0632 3521 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | ±5 % of reading |
| Repeatability | ≤2 % |
| Response Time | 10 s |
| Stability | ±5 % |
| Measured Gases | CO, CO₂, NO, NO₂, SO₂, H₂S, and CₓHᵧ |
| Brand | testo |
|---|---|
| Origin | Shenzhen, China |
| Model | testo 350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S), NDIR (CO₂, CxHy), Catalytic Combustion (CxHy) |
| Response Time (t95) | 20 s (O₂), <30 s (SO₂), <40 s (CO), <10 s (CO₂ via NDIR) |
| Accuracy | ±5% of reading (typical for electrochemical sensors), ±4 ppm (SO₂, low range), ±0.3 Vol.% + 1% (CO₂, NDIR) |
| Detection Parameters | O₂, CO, NO, NO₂, SO₂, SO₂low, H₂S, CO₂ (calculated & NDIR), CxHy (CH₄, C₃H₈, C₄H₁₀), differential pressure, ambient & flue gas temperature, velocity, dew point, efficiency, heat loss |
| Sensor Interference Compensation | CO-compensated SO₂ and SO₂low sensors (up to 10,000 ppm CO), H₂-compensated CO and COlow |
| Preconditioning | Integrated high-efficiency gas conditioning module with condensate separation, multi-stage particulate filtration, automatic dilution for high-concentration sampling |
| Connectivity | testo DataBus interface (supports up to 16 analyzers in cascade), USB, Bluetooth, Wi-Fi, LIMS-compatible data export |
| Operating Temperature | −5 °C to +45 °C |
| Battery Life | Up to 5 h (rechargeable Li-ion) |
| Dimensions | 330 × 128 × 438 mm |
| Weight | 4800 g |
| IP Rating | IP40 |
| Max. Dust Load | 20 g/m³ |
| Max. Flue Gas Pressure | −300 mbar (vacuum) / +50 mbar (overpressure) |
| Max. Flue Gas Temp (via probe) | 1800 °C (Type S) |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | testo 350 |
| Instrument Type | Portable Flue Gas Analyzer |
| Measurement Principle | Electrochemical (O₂, CO, NO, NO₂, SO₂, H₂S), NDIR (CO₂), Catalytic Combustion (CxHy) |
| Accuracy | ±5% of reading (for most gases, with low-range exceptions) |
| Response Time (t₉₅) | 20 s |
| Detection Gases (Configurable) | O₂, CO, COlow, NO, NOlow, NO₂, SO₂, H₂S, CO₂ (NDIR), CxHy (CH₄/C₃H₈/C₄H₁₀) |
| Operating Temperature | −5 to +45 °C |
| Storage Temperature | −20 to +50 °C |
| Dimensions | 88 × 38 × 220 mm |
| Weight | 440 g |
| Battery Life | Up to 5 h (without wireless) |
| Memory Capacity | 2 MB (~250,000 measurement values) |
| Protection Class | IP40 |
| Data Connectivity | Bluetooth® 4.0, USB, optional WLAN module |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 370 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy (Indication Error) | < ±2% of full scale |
| Repeatability | < ±2% of full scale |
| Response Time (T90) | ≤90 s |
| Long-Term Stability | < ±2% of full scale |
| Measurable Gases | CO, NO, N₂O, NO₂, NH₃, CH₄, HCl, SO₂, CO₂, H₂O, O₂ |
| Calibration | Zero calibration using ambient air only |
| Gas Supply Requirement | None (no instrument air required) |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | TESTO340 |
| Instrument Type | Portable Flue Gas Analyzer |
| Indication Error | < ±5% |
| Repeatability | < ±5% |
| Response Time | < 40 s |
| Stability | < ±5% |
| Measurable Gases | SO₂, CO, COlow, NO, NOlow, NO₂, O₂ |
| Differential Pressure & Flow Velocity Measurement | Built-in |
| Sensor Architecture | Modular, 3 Expandable Sensor Slots (O₂ standard |
| Fuel Database | 10 Predefined + 10 User-Defined Fuels |
| Data Interface | USB to easyEmission PC Software |
| Compliance | Designed for EN 50379-1/-2, EN 15545, VDI 3862, and applicable EPA Method 6C/7E prerequisites |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | <5% |
| Repeatability | <2% |
| Response Time | <90 s |
| Stability | <5% |
| Measured Gases | O₂, CO, NO, NO₂, SO₂ |
| Optional Sensors | CO₂ (IR), H₂S |
| Sampling Flow Rate | 1.0 L/min (regulated) |
| Data Storage Capacity | 250,000 values |
| Operating Temperature Range | –0 °C to +1000 °C (with high-temp probe) |
| Differential Pressure Range | –200 to +200 hPa |
| IP Rating | IP40 |
| Weight | 4.8 kg |
| Dimensions | 330 × 128 × 438 mm |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | TFC-30 |
| Pricing | Upon Request |
| Flow Rate Options | 5–30 L/min, 3–30 L/min, 1–15 L/min, 5–25 L/min |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1‰ |
| Maximum Negative Pressure | ≥15,000 Pa |
| Charging Current | 300 mA |
| Power Supply | 10 V DC / 220 V AC, 50 Hz |
| Operating Temperature | −25 to +45 °C |
| Noise Level | ≤60 dB(A) |
| Relative Humidity | ≤85% RH |
| Dimensions | 200 × 160 × 140 mm |
| Battery | Built-in Ni-MH rechargeable battery (fully charged voltage ≈12 V, runtime ≈4 h continuous) |
| Display | LCD with real-time countdown and flow indication |
| Control | Microprocessor-based timer with pause/resume function, programmable 00:00–99:59 (hh:mm) countdown |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TFC-30S |
| Pricing | Available Upon Request |
| Flow Options | 5–30 L/min, 3–30 L/min, 1–15 L/min, or 5–25 L/min |
| Flow Accuracy | ≤ ±2.5% of full scale |
| Timing Accuracy | ≤ ±0.1% |
| Maximum Vacuum | ≥15,000 Pa |
| Charging Current | 300 mA (standard) |
| Power Supply | 10 V DC (rechargeable Ni-Cd battery) / 220 V AC, 50 Hz |
| Battery Runtime | ~3 hours continuous operation per full charge |
| Timer Range | 1 min to 99 h 59 min (programmable countdown) |
| Compliance | Designed for ISO 7708:1995 and GB/T 17061–1997 compliant airborne particulate sampling |
| Origin | Hubei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Origin | Yes |
| Model | TH-2000 |
| Pricing | Upon Request |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | TH-30 |
| Pricing | Available Upon Request |
| Flow Range Options | 5–30 L/min, 3–30 L/min, 5–25 L/min, or 10–25 L/min |
| Sampling Duration | Up to 99 h 59 min |
| Vacuum Pressure | >3000 Pa |
| Operating Temperature | −20 °C to +40 °C |
| Relative Humidity | ≤85% RH |
| Dimensions | 180 × 130 × 125 mm |
| Weight | ~2.0 kg |
| Noise Level | <80 dB(A) |
| Continuous Runtime | >180 min (fully charged) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TH-30S |
| Pricing | Available Upon Request |
| Flow Range Options | 5–30 L/min |
| Constant-Flow Control | Microprocessor-Based |
| Display | LCD |
| Power Supply | AC/DC Dual-Mode, Optional Rechargeable Ni-Cd Battery |
| Negative Pressure | >3000 Pa |
| Timer Range | 0–99 h 59 min |
| Continuous Operation | ≥180 min |
| Noise Level | <80 dB(A) |
| Operating Temperature | −20 °C to +40 °C |
| Relative Humidity | ≤85 % RH |
| Dimensions | 180 × 130 × 125 mm |
| Weight | ≈2.0 kg |
| Sampling Targets | Respirable Fraction (BMRC-curve compliant at 20 L/min) and Total Dust |
| Impact Plate | Φ25 mm glass slide coated with silicone oil |
| Compliance Reference | BMRC (British Medical Research Council) respirable dust convention |
| Origin | Hubei, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TH-502 |
| Pricing | Upon Request |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Type | Online Gas Analyzer |
| Model | THA100 |
| Detection Principle | NDIR (Non-Dispersive Infrared) |
| Measured Gas | NH₃ |
| Range | 0–300 ppm and 0–100% vol |
| Operating Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Repeatability | ±1% FS |
| Linearity Error | ±2% FS |
| Response Time (T90) | ≤25 s |
| Temperature Drift | ±2% FS (5–45 °C) |
| Interference Error | ±2% FS |
| Output | 4–20 mA analog, 8 relay outputs |
| Display | Color LCD with touch interface |
| Optional Configuration | Dual-gas IR + O₂ sensor (electrochemical or zirconia) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | THA100-NH3 |
| Instrument Type | Online Gas Analyzer |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Target Gas | NH₃ (Ammonia) |
| Range | 0–300 ppm and 0–100% vol (dual-range configuration) |
| Operating Temperature | 5–45 °C |
| Stability | ±2% FS / 7 days |
| Repeatability | ≤1% FS |
| Linearity Error | ±2% FS |
| Response Time (T90) | ≤25 s |
| Temperature Drift | ±2% FS (5–45 °C) |
| Interference Error | ±2% FS |
| Output | 4–20 mA analog current loop |
| Digital I/O | 8 isolated relay outputs |
| Display | Color LCD with capacitive touch interface |
| Optional O₂ Channel | Yes (electrochemical or paramagnetic sensor integration) |
| Brand | TH-analyzer |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | THA100NO |
| Instrument Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Type | Online Fixed-Mount Analyzer |
| Response Time (T90) | ≤25 s |
| Repeatability | ±1% FS |
| Measurement Range (NO) | 0–500 mg/m³ or 0–50% vol |
| Operating Temperature | 5–45 °C |
| Zero/Full-Scale Stability | ±2% FS / 7 days |
| Linearity Error | ±2% FS |
| Temperature Drift | ±2% FS (5–45 °C) |
| Interference Error | ±2% FS |
| Pressure Compensation | Yes |
| Output | 4–20 mA analog, 8 isolated relay outputs |
| Display | Color LCD with capacitive touch interface |
| Multi-Gas Capability | Up to 3 components (e.g., NO + optional O₂ + one additional IR-active gas) |
| Optical Core | MEMS-based pulsed infrared source, dual-channel pyroelectric detector |
| Environmental Compliance | Designed for continuous operation in industrial CEMS and laboratory-grade monitoring environments |