Empowering Scientific Discovery

Global Analytical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginItaly
ModelECS 8024 NC SOIL SPECIAL
Detection PrincipleHigh-Temperature Catalytic Combustion (Dumas Method)
Elements MeasuredTotal Carbon (TC), Total Nitrogen (TN)
Optional CouplingTIC DISCOVER for Total Inorganic Carbon (TIC)
Detector TypeThermal Conductivity Detector (TCD)
Column Temperature Range30–110 °C
Sample TypesSoils, Fertilizers, Sludges, Sediments, Plant Tissues
Automation LevelFully Automated with Motorized/Pneumatic/Manual Sampler Options
Software ControlPC-based with Touchscreen Interface
Compliance ReadySupports GLP/GMP audit trails, ASTM D5373, ISO 10694, USP <281>, EN 15936
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPCS Instruments
OriginUnited Kingdom
ModelMTM-EC
Instrument TypeMulti-Functional Tribological Tester
Maximum Friction Force75 N
Temperature RangeAmbient to 150 °C
Contact Pressure Range0–1.25 GPa (standard), up to 3.1 GPa (optional)
Sliding Speed−4 to +4 m/s
Electrochemical Potential Range±60 V (high range), ±10 V (low range)
Current Range0–3.5 A (high), 0–200 mA (low)
Measurement Noise±120 mV / ±20 mA (high), ±20 mV / ±0.4 mA (low)
Sample Volume30 mL (10 mL with optional filler kit)
Dimensions (H×W×D)400 × 400 × 600 mm
Weight30 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
ModelCP610
Temperature Range–70 °C to +30 °C
Temperature Control Accuracy±0.1 °C
Cooling Capacity600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C
Cooling Rate~30 °C/h (average)
Sample Capacity4-position rotating bath
Bath Volume3.8 L
Dimensions42 × 53 × 66 cm
Weight~68 kg
Power Supply220 V, 10 A, 50/60 Hz, single-phase
ComplianceASTM D97, ASTM D2500, ISO 3016, ISO 2084, IP 15, GB/T 6986, GB/T 3536
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZahner
OriginGermany
ModelIM7
Instrument TypeElectrochemical Workstation
Channel CountSingle-Channel
Current Range±3 A
Current Accuracy< 0.0025%
Potential Range±15 V
EIS Frequency Range10 µHz – 8 MHz
Input Impedance>10 TΩ
ADC Resolution32-bit
Voltage Resolution2.5 nV / 7.5 nV
Current Resolution±2 aA (2 × 10⁻¹⁸ A)
Small-Signal Rise Time150 ns – 200 µs (5 auto-ranging steps)
IR CompensationReal-time, adaptive
Grounding ModeSwitchable floating/grounded
Communication InterfaceGigabit Ethernet
Internal Storage40 GB SSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
Model002‐001‐003
Testing PrincipleTimken EP Test (ASTM D2509, ASTM D2782, SH/T 0203)
Maximum Applied Load92,300 psi (on 0.022 in. wide Timken test block)
Rotational Speed800 rpm ± 5 rpm (adjustable up to 850 rpm)
Test Duration10 min ± 15 s
Temperature Control RangeAmbient to 120 °C (digital PID controller with fluid circulation system)
Oil Reservoir Capacity3 L (heated, pumped, valve-controlled
Grease Auto-Feeder Rate45 ± 9 g/min
Drive Motor2 HP, unidirectional, with RPM display
Load ApplicationStatic load via 10:1 lever arm
Sample TypesLiquid lubricants and greases
ComplianceASTM D2509, ASTM D2782, SH/T 0203
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDolomite
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPLGA Nanoparticle Encapsulation System
Carrier MaterialPoly(lactic-co-glycolic acid) (PLGA)
Encapsulation MethodContinuous-Flow Microfluidics
Particle Uniformity (CV)≤5%
Typical Particle Size Range100–500 nm
Encapsulation Efficiency30–100%
Batch-to-Batch ReproducibilityHigh
Compliance ContextDesigned for R&D and preclinical GMP-aligned nanomedicine process development
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
Model001-001-331
Test TypeFriction and Wear
Load Capacity (Standard)805 lbf
Load Capacity (Optional)1300 lbf
Speed RangeProgrammable RPM Control
Temperature Range (Standard Chamber)Ambient to 200 °C
Temperature Range (Pressurized Chamber, Optional)Ambient to 250 °C
Sub-ambient TestingAvailable with External Chiller
Friction Force Measurement Range (Standard)0–250 lbf
Friction Force Measurement Range (Optional Low-Load Sensor)0–25 lbf
Compliant StandardsASTM D2714, D2981, D3704, D2509, D2782, G77
Test GeometriesBlock-on-Ring, Conforming Block-on-Ring, Timken Canted Cylinder, Chip-on-Ring, Ball-on-Ring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCore Separations
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelBenchTop Series
Price RangeUSD $65,000 – $105,000 (FOB)
Max Operating Temperature150 °C
Max System Pressure689 bar
CO₂ Mass Flow Rateup to 15 g/min
Co-solvent Pump Pressure Rating689 bar
Extractor Vessel VolumeStandard 100 mL (configurable)
Temperature Control Accuracy±0.5 °C
Pressure Control Stability±2 bar
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTBS2100E-F / TBS3000
PriceUpon Request
Dimensions (Viscometer)18 × 30.5 × 35.5 cm
Dimensions (Control Unit)46 × 46 × 15 cm
Dimensions (Auto-sampler, optional)46 × 51 × 61 cm
Weight (Viscometer)15.5 kg
Weight (Control Unit)9 kg
Weight (Auto-sampler)25.4 kg
Voltage220–240 V AC
Frequency50/60 Hz
Sample Volume50 mL (recommended)
Test Duration per Sample~5–7 min
Temperature Range40 °C to 200 °C (±0.1 °C stability)
Shear Rate Range5×10⁴ s⁻¹ to 7×10⁶ s⁻¹
Speed Steps12 discrete settings (800–8000 rpm)
Overtemperature ProtectionProgrammable safety limit
ComplianceCE-marked
Shipping Weight (Manual System)68 kg
Shipping Weight (Auto System)72.5 kg
Shipping Dimensions (Manual)61 × 81 × 89 cm
Shipping Dimensions (Auto)61 × 81 × 127 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBLB701 / BLB702 / BLB DIN
Product TypeLaboratory Instrument
Test ParameterLow-Temperature Apparent Viscosity (ASTM D2983, IP 295, GB/T 6538)
ComplianceASTM D2983, IP 295, GB/T 6538
Dimensions (W×D×H)48 × 53 × 66 cm
Weight~68 kg
Voltage220 VAC, 50/60 Hz, Single Phase
Fuse RatingBLB701: 10 A
BLB7022 × 10 A
BLB-DIN12 A max
Cooling Capacity600 W at 0 °C, 300 W at −40 °C, 100 W at −70 °C
Heating Capacity600 W
Temperature RangeBLB701: 30 °C to −40 °C
BLB70230 °C to −70 °C
BLB-DIN30 °C to −55 °C
Viewing Window~41 × 23 cm
Sample Capacity12-position bath
Bath Volume3.8 L
Safety FeaturesHigh-pressure cutoff, over-temperature limit, low-fluid-level detection and auto-shutdown
CertificationCE
Shipping Weight122–136 kg
Shipping Dimensions81 × 76 × 104 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCore Separations
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBDS
Extraction Volume50–100 L
Maximum Operating Pressure80 bar
Maximum Mass Flow Rate500 g/min (non-condensing) / 2 kg/min (with −20 °C condensation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPaeonia Innovations
OriginSingapore
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPaeonia IR
Instrument TypeOnline
Wavenumber Range900–1800 cm⁻¹
Dimensions50 × 55 × 60 mm
Weight450 g
Response Time0.3 s
Operating Pressure0–5 bar
Operating Temperature−15 °C to +60 °C
Flow Path Fitting1/8″ NPT or Swagelok
Power Supply5 V DC via USB-C
Software PlatformWindows 10 & 11 Native Application for Real-Time Data Acquisition and Instrument Control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTFAB
Product TypeLaboratory Instrument
Test ParameterFoam Characteristics
Compliance StandardsASTM D892, IP 146, ISO 6247
Dimensions (W×D×H)61 × 61 × 53 cm
Weight72.5 kg
Power Supply220 V, Single-phase, 10 A, 50/60 Hz
Heating MediumForced Air
MotorDC-driven, maintenance-free
Aeration HeadStainless steel cylindrical head with pre-heated air supply
Air Flow SystemDual integrated mass flow meters
Air Flow Rate94–200 mL/min (±5 mL/min)
Temperature Range20–175 °C (±0.1 °C)
Test ProgramsFour standardized sequences (I: 24 °C, II: 93.5 °C, III: 24 °C, IV: 150 °C)
Sample Volume200 mL
Test CapacitySix 1000-mL graduated cylinders
DisplayTouchscreen controller with real-time digital readouts, programmable alarms, and elapsed time tracking
SafetyDual thermal protection (fuse + current-limiting fuse), CE certified
Shipping Weight/Dimensions~90 kg / 71 × 71 × 122 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
ModelKV801 / KV802 / KV803
Temperature RangeKV801: +30 °C to –40 °C
KV802+30 °C to –70 °C
KV803+40 °C to 150 °C
Temperature Stability±0.1 °C (digital) / ±0.01 °C (analog) for KV801/KV802
Cooling Capacity600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C
Heating Capacity1500 W (KV803 only)
Bath Volume~11.5 L
Sample Capacity4 capillary viscometers (KV801/KV802), 6 capillary viscometers (KV803)
Dimensions (W×D×H)42 cm × 53 cm × 66 cm
Net Weight~68 kg
Shipping Weight122–136 kg
Shipping Dimensions (W×D×H)81 cm × 76 cm × 104 cm
Power SupplyKV801/KV802: 208–220 V, 10 A, 50/60 Hz
KV803220 V, 8 A, 50/60 Hz
RefrigerantsR410A (KV801), R507/R508B (KV802)
Compressor1/3 HP
Viewing Window41 cm × 23 cm
ComplianceASTM D445, GB/T 265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPCS Instruments
OriginUnited Kingdom
ModelHPR
Instrument TypeReciprocating Tribological Tester
Maximum Friction Force1–10 N
Temperature RangeAmbient to 130 °C
Load Range1–10 N
Contact Pressure0–1.4 GPa
Frequency Range10–200 Hz
Stroke Length20 µm–1.8 mm
Chamber Pressure Range10⁻⁵ torr to 10 bar
Sample Volume Capacity15 mL
Chamber DesignFully Sealed, Removable & Pressure/Vacuum-Retentive
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSyrris
OriginUnited Kingdom
ModelAtlas-sodium
Vessel Capacities100, 160, 300, 450 mL
Construction MaterialStainless Steel 316 (standard), optional Hastelloy or Titanium
Maximum Operating Pressure200 bar
Maximum Temperature250 °C
Mechanical Stirring Speedup to 800 rpm
Magnetic Stirring Speedup to 1200 rpm
Pressure ControlAutomated via integrated pressure control module
Gas SelectionUp to 3 gases, switchable via front panel or PC software
Safety CertificationPED 2014/68/EU and ASME Section VIII compliant
Data LoggingReal-time recording of temperature, pressure, stirring speed, gas selection status, and event timestamps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
ModelFAL400
ComplianceASTM D3241, IP 323, GB/T 9169
Heating Tube CertificationASTM D3241 Table 2 Note c, IP 323 Table A.1
AutomationFully automated air purge (1.5 L/min), pre-test pump priming (60 s), flow verification at start/end
Pump SystemDual HPLC-grade precision pumps, pulse-free flow delivery
Control SystemEmbedded microprocessor (non-Windows), corrosion-resistant color touchscreen
SafetyInterlocked safety shield with real-time alarm
FiltrationIntegrated activated carbon fume scrubber
Optional AccessoryFAL430 Deposit Rating Ellipsometer (ellipsometric thickness & 3D topography measurement)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginItaly
ModelECS 8020
Analysis PrincipleHigh-Temperature Catalytic Combustion (Dumas Method)
Elements DeterminedC, H, N, S (O optional)
Detection MethodThermal Conductivity Detection (TCD)
Chromatographic SeparationIsothermal GC column (30–110 °C)
Automation LevelFully automated with microprocessor control and PC integration
Sample Introduction OptionsManual, Pneumatic, Motorized Zero-Blank Autosampler
Detector FeaturesReference-gas-free TCD with auto-calibration
Software InterfaceDedicated Windows-based acquisition and reporting software with audit trail capability
Compliance SupportDesigned for GLP/GMP environments
Isotope InterfaceIntegrated IDMicro EA port for coupling to isotope ratio mass spectrometers (IRMS)
Power & Gas ManagementStandby mode reduces carrier gas consumption (He or Ar), energy use, and idle time
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas & King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTBS 3000
Product TypeLaboratory Instrument
Test ParameterHTHS Viscosity
Compliance StandardsASTM D4683, ASTM D6616, SAE J300, GB/T 6538
Dimensions (W × D × H)66 × 66 × 48 cm
Weight38.5 kg
Power Supply100–240 VAC, ≤6 A, 50/60 Hz
Viscosity Range1–30 mPa·s (cP)
Sample Volume40 mL (recommended)
Test Duration per Sample~5–7 min
Auto-sampler Capacity1–40 samples per sequence
Temperature Control Setpoints80 °C, 100 °C, 150 °C (±0.1 °C)
Shear Rate Range5×10⁵ s⁻¹ to 3×10⁶ s⁻¹ (dependent on fluid viscosity and temperature)
DisplayDigital touchscreen interface
Safety FeaturesAutomatic torque motor and stator heater shutdown upon power interruption
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNC Technologies
OriginItaly
ModelECS 4010
Analysis PrincipleHigh-Temperature Catalytic Combustion (Dumas Method)
Elements MeasuredC, H, N, S (optional O)
DetectionThermal Conductivity Detector (TCD), self-calibrating, reference-gas-free
Chromatographic SeparationIsothermal GC column (30–110 °C)
Automation LevelFully automated microprocessor-controlled system with PC integration
Sample IntroductionPneumatic and Zero-Blank electric autosamplers
Isotope Ratio CompatibilityYes (MS-coupling enabled)
Compliance FrameworkDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPCS Instruments
OriginUnited Kingdom
ModelABS
Power Supply100–230 V AC, 750 VA
Operating Temperature15–35 °C
Operating Humidity20–80 % RH (non-condensing)
Weight34 kg
DimensionsNot specified
Compressed Air RequirementASTM D5001-compliant (≤0.1 ppm hydrocarbons), dry and oil-free
Deionized Water Reservoir Capacity~1000 tests per fill
ControlMicroprocessor-based, fully automated
Environmental ComplianceDesigned for ISO/IEC 17025-aligned laboratories
Software InterfacePC-based control and data logging with audit-trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCore Separations
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSubcritical Water Extraction System
Price RangeUSD 210,000 – 280,000
Max Temperature400 °C
Max Pressure550 bar
Flow Rate Range5–200 g/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFalex
OriginUSA
Model450-001-002
Heating Tube Temperature Range300–450 °C
Temperature Control Accuracy±2 °C
Flow Rate Range0.55–10.0 mL/min
Pressure Range0–200 psi
Test Duration2.5–500 hours
Sample Reservoir Temperature100–210 °C
Sample Volume100 mL–1 L
ComplianceSAE ARP 5996B, SAE AS5780
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTannas&King
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelTanEV WCT
Product TypeLaboratory Instrument
ComplianceSAE J3200 (in development), ASTM method under preparation
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0