- All
- Favorite
- Popular
- Most rated
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8024 NC SOIL SPECIAL |
| Detection Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | Total Carbon (TC), Total Nitrogen (TN) |
| Optional Coupling | TIC DISCOVER for Total Inorganic Carbon (TIC) |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Column Temperature Range | 30–110 °C |
| Sample Types | Soils, Fertilizers, Sludges, Sediments, Plant Tissues |
| Automation Level | Fully Automated with Motorized/Pneumatic/Manual Sampler Options |
| Software Control | PC-based with Touchscreen Interface |
| Compliance Ready | Supports GLP/GMP audit trails, ASTM D5373, ISO 10694, USP <281>, EN 15936 |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MTM-EC |
| Instrument Type | Multi-Functional Tribological Tester |
| Maximum Friction Force | 75 N |
| Temperature Range | Ambient to 150 °C |
| Contact Pressure Range | 0–1.25 GPa (standard), up to 3.1 GPa (optional) |
| Sliding Speed | −4 to +4 m/s |
| Electrochemical Potential Range | ±60 V (high range), ±10 V (low range) |
| Current Range | 0–3.5 A (high), 0–200 mA (low) |
| Measurement Noise | ±120 mV / ±20 mA (high), ±20 mV / ±0.4 mA (low) |
| Sample Volume | 30 mL (10 mL with optional filler kit) |
| Dimensions (H×W×D) | 400 × 400 × 600 mm |
| Weight | 30 kg |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | CP610 |
| Temperature Range | –70 °C to +30 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Cooling Capacity | 600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C |
| Cooling Rate | ~30 °C/h (average) |
| Sample Capacity | 4-position rotating bath |
| Bath Volume | 3.8 L |
| Dimensions | 42 × 53 × 66 cm |
| Weight | ~68 kg |
| Power Supply | 220 V, 10 A, 50/60 Hz, single-phase |
| Compliance | ASTM D97, ASTM D2500, ISO 3016, ISO 2084, IP 15, GB/T 6986, GB/T 3536 |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7 |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Accuracy | < 0.0025% |
| Potential Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (2 × 10⁻¹⁸ A) |
| Small-Signal Rise Time | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 002‐001‐003 |
| Testing Principle | Timken EP Test (ASTM D2509, ASTM D2782, SH/T 0203) |
| Maximum Applied Load | 92,300 psi (on 0.022 in. wide Timken test block) |
| Rotational Speed | 800 rpm ± 5 rpm (adjustable up to 850 rpm) |
| Test Duration | 10 min ± 15 s |
| Temperature Control Range | Ambient to 120 °C (digital PID controller with fluid circulation system) |
| Oil Reservoir Capacity | 3 L (heated, pumped, valve-controlled |
| Grease Auto-Feeder Rate | 45 ± 9 g/min |
| Drive Motor | 2 HP, unidirectional, with RPM display |
| Load Application | Static load via 10:1 lever arm |
| Sample Types | Liquid lubricants and greases |
| Compliance | ASTM D2509, ASTM D2782, SH/T 0203 |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PLGA Nanoparticle Encapsulation System |
| Carrier Material | Poly(lactic-co-glycolic acid) (PLGA) |
| Encapsulation Method | Continuous-Flow Microfluidics |
| Particle Uniformity (CV) | ≤5% |
| Typical Particle Size Range | 100–500 nm |
| Encapsulation Efficiency | 30–100% |
| Batch-to-Batch Reproducibility | High |
| Compliance Context | Designed for R&D and preclinical GMP-aligned nanomedicine process development |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 001-001-331 |
| Test Type | Friction and Wear |
| Load Capacity (Standard) | 805 lbf |
| Load Capacity (Optional) | 1300 lbf |
| Speed Range | Programmable RPM Control |
| Temperature Range (Standard Chamber) | Ambient to 200 °C |
| Temperature Range (Pressurized Chamber, Optional) | Ambient to 250 °C |
| Sub-ambient Testing | Available with External Chiller |
| Friction Force Measurement Range (Standard) | 0–250 lbf |
| Friction Force Measurement Range (Optional Low-Load Sensor) | 0–25 lbf |
| Compliant Standards | ASTM D2714, D2981, D3704, D2509, D2782, G77 |
| Test Geometries | Block-on-Ring, Conforming Block-on-Ring, Timken Canted Cylinder, Chip-on-Ring, Ball-on-Ring |
| Brand | Core Separations |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BenchTop Series |
| Price Range | USD $65,000 – $105,000 (FOB) |
| Max Operating Temperature | 150 °C |
| Max System Pressure | 689 bar |
| CO₂ Mass Flow Rate | up to 15 g/min |
| Co-solvent Pump Pressure Rating | 689 bar |
| Extractor Vessel Volume | Standard 100 mL (configurable) |
| Temperature Control Accuracy | ±0.5 °C |
| Pressure Control Stability | ±2 bar |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS2100E-F / TBS3000 |
| Price | Upon Request |
| Dimensions (Viscometer) | 18 × 30.5 × 35.5 cm |
| Dimensions (Control Unit) | 46 × 46 × 15 cm |
| Dimensions (Auto-sampler, optional) | 46 × 51 × 61 cm |
| Weight (Viscometer) | 15.5 kg |
| Weight (Control Unit) | 9 kg |
| Weight (Auto-sampler) | 25.4 kg |
| Voltage | 220–240 V AC |
| Frequency | 50/60 Hz |
| Sample Volume | 50 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Temperature Range | 40 °C to 200 °C (±0.1 °C stability) |
| Shear Rate Range | 5×10⁴ s⁻¹ to 7×10⁶ s⁻¹ |
| Speed Steps | 12 discrete settings (800–8000 rpm) |
| Overtemperature Protection | Programmable safety limit |
| Compliance | CE-marked |
| Shipping Weight (Manual System) | 68 kg |
| Shipping Weight (Auto System) | 72.5 kg |
| Shipping Dimensions (Manual) | 61 × 81 × 89 cm |
| Shipping Dimensions (Auto) | 61 × 81 × 127 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BLB701 / BLB702 / BLB DIN |
| Product Type | Laboratory Instrument |
| Test Parameter | Low-Temperature Apparent Viscosity (ASTM D2983, IP 295, GB/T 6538) |
| Compliance | ASTM D2983, IP 295, GB/T 6538 |
| Dimensions (W×D×H) | 48 × 53 × 66 cm |
| Weight | ~68 kg |
| Voltage | 220 VAC, 50/60 Hz, Single Phase |
| Fuse Rating | BLB701: 10 A |
| BLB702 | 2 × 10 A |
| BLB-DIN | 12 A max |
| Cooling Capacity | 600 W at 0 °C, 300 W at −40 °C, 100 W at −70 °C |
| Heating Capacity | 600 W |
| Temperature Range | BLB701: 30 °C to −40 °C |
| BLB702 | 30 °C to −70 °C |
| BLB-DIN | 30 °C to −55 °C |
| Viewing Window | ~41 × 23 cm |
| Sample Capacity | 12-position bath |
| Bath Volume | 3.8 L |
| Safety Features | High-pressure cutoff, over-temperature limit, low-fluid-level detection and auto-shutdown |
| Certification | CE |
| Shipping Weight | 122–136 kg |
| Shipping Dimensions | 81 × 76 × 104 cm |
| Brand | Core Separations |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BDS |
| Extraction Volume | 50–100 L |
| Maximum Operating Pressure | 80 bar |
| Maximum Mass Flow Rate | 500 g/min (non-condensing) / 2 kg/min (with −20 °C condensation) |
| Brand | Paeonia Innovations |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Instrument Type | Online |
| Wavenumber Range | 900–1800 cm⁻¹ |
| Dimensions | 50 × 55 × 60 mm |
| Weight | 450 g |
| Response Time | 0.3 s |
| Operating Pressure | 0–5 bar |
| Operating Temperature | −15 °C to +60 °C |
| Flow Path Fitting | 1/8″ NPT or Swagelok |
| Power Supply | 5 V DC via USB-C |
| Software Platform | Windows 10 & 11 Native Application for Real-Time Data Acquisition and Instrument Control |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TFAB |
| Product Type | Laboratory Instrument |
| Test Parameter | Foam Characteristics |
| Compliance Standards | ASTM D892, IP 146, ISO 6247 |
| Dimensions (W×D×H) | 61 × 61 × 53 cm |
| Weight | 72.5 kg |
| Power Supply | 220 V, Single-phase, 10 A, 50/60 Hz |
| Heating Medium | Forced Air |
| Motor | DC-driven, maintenance-free |
| Aeration Head | Stainless steel cylindrical head with pre-heated air supply |
| Air Flow System | Dual integrated mass flow meters |
| Air Flow Rate | 94–200 mL/min (±5 mL/min) |
| Temperature Range | 20–175 °C (±0.1 °C) |
| Test Programs | Four standardized sequences (I: 24 °C, II: 93.5 °C, III: 24 °C, IV: 150 °C) |
| Sample Volume | 200 mL |
| Test Capacity | Six 1000-mL graduated cylinders |
| Display | Touchscreen controller with real-time digital readouts, programmable alarms, and elapsed time tracking |
| Safety | Dual thermal protection (fuse + current-limiting fuse), CE certified |
| Shipping Weight/Dimensions | ~90 kg / 71 × 71 × 122 cm |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Model | KV801 / KV802 / KV803 |
| Temperature Range | KV801: +30 °C to –40 °C |
| KV802 | +30 °C to –70 °C |
| KV803 | +40 °C to 150 °C |
| Temperature Stability | ±0.1 °C (digital) / ±0.01 °C (analog) for KV801/KV802 |
| Cooling Capacity | 600 W at 0 °C, 300 W at –40 °C, 100 W at –70 °C |
| Heating Capacity | 1500 W (KV803 only) |
| Bath Volume | ~11.5 L |
| Sample Capacity | 4 capillary viscometers (KV801/KV802), 6 capillary viscometers (KV803) |
| Dimensions (W×D×H) | 42 cm × 53 cm × 66 cm |
| Net Weight | ~68 kg |
| Shipping Weight | 122–136 kg |
| Shipping Dimensions (W×D×H) | 81 cm × 76 cm × 104 cm |
| Power Supply | KV801/KV802: 208–220 V, 10 A, 50/60 Hz |
| KV803 | 220 V, 8 A, 50/60 Hz |
| Refrigerants | R410A (KV801), R507/R508B (KV802) |
| Compressor | 1/3 HP |
| Viewing Window | 41 cm × 23 cm |
| Compliance | ASTM D445, GB/T 265 |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | HPR |
| Instrument Type | Reciprocating Tribological Tester |
| Maximum Friction Force | 1–10 N |
| Temperature Range | Ambient to 130 °C |
| Load Range | 1–10 N |
| Contact Pressure | 0–1.4 GPa |
| Frequency Range | 10–200 Hz |
| Stroke Length | 20 µm–1.8 mm |
| Chamber Pressure Range | 10⁻⁵ torr to 10 bar |
| Sample Volume Capacity | 15 mL |
| Chamber Design | Fully Sealed, Removable & Pressure/Vacuum-Retentive |
| Brand | Syrris |
|---|---|
| Origin | United Kingdom |
| Model | Atlas-sodium |
| Vessel Capacities | 100, 160, 300, 450 mL |
| Construction Material | Stainless Steel 316 (standard), optional Hastelloy or Titanium |
| Maximum Operating Pressure | 200 bar |
| Maximum Temperature | 250 °C |
| Mechanical Stirring Speed | up to 800 rpm |
| Magnetic Stirring Speed | up to 1200 rpm |
| Pressure Control | Automated via integrated pressure control module |
| Gas Selection | Up to 3 gases, switchable via front panel or PC software |
| Safety Certification | PED 2014/68/EU and ASME Section VIII compliant |
| Data Logging | Real-time recording of temperature, pressure, stirring speed, gas selection status, and event timestamps |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | FAL400 |
| Compliance | ASTM D3241, IP 323, GB/T 9169 |
| Heating Tube Certification | ASTM D3241 Table 2 Note c, IP 323 Table A.1 |
| Automation | Fully automated air purge (1.5 L/min), pre-test pump priming (60 s), flow verification at start/end |
| Pump System | Dual HPLC-grade precision pumps, pulse-free flow delivery |
| Control System | Embedded microprocessor (non-Windows), corrosion-resistant color touchscreen |
| Safety | Interlocked safety shield with real-time alarm |
| Filtration | Integrated activated carbon fume scrubber |
| Optional Accessory | FAL430 Deposit Rating Ellipsometer (ellipsometric thickness & 3D topography measurement) |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Motorized Zero-Blank Autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Software Interface | Dedicated Windows-based acquisition and reporting software with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Isotope Interface | Integrated IDMicro EA port for coupling to isotope ratio mass spectrometers (IRMS) |
| Power & Gas Management | Standby mode reduces carrier gas consumption (He or Ar), energy use, and idle time |
| Brand | Tannas & King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TBS 3000 |
| Product Type | Laboratory Instrument |
| Test Parameter | HTHS Viscosity |
| Compliance Standards | ASTM D4683, ASTM D6616, SAE J300, GB/T 6538 |
| Dimensions (W × D × H) | 66 × 66 × 48 cm |
| Weight | 38.5 kg |
| Power Supply | 100–240 VAC, ≤6 A, 50/60 Hz |
| Viscosity Range | 1–30 mPa·s (cP) |
| Sample Volume | 40 mL (recommended) |
| Test Duration per Sample | ~5–7 min |
| Auto-sampler Capacity | 1–40 samples per sequence |
| Temperature Control Setpoints | 80 °C, 100 °C, 150 °C (±0.1 °C) |
| Shear Rate Range | 5×10⁵ s⁻¹ to 3×10⁶ s⁻¹ (dependent on fluid viscosity and temperature) |
| Display | Digital touchscreen interface |
| Safety Features | Automatic torque motor and stator heater shutdown upon power interruption |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (optional O) |
| Detection | Thermal Conductivity Detector (TCD), self-calibrating, reference-gas-free |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated microprocessor-controlled system with PC integration |
| Sample Introduction | Pneumatic and Zero-Blank electric autosamplers |
| Isotope Ratio Compatibility | Yes (MS-coupling enabled) |
| Compliance Framework | Designed for GLP/GMP environments |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | ABS |
| Power Supply | 100–230 V AC, 750 VA |
| Operating Temperature | 15–35 °C |
| Operating Humidity | 20–80 % RH (non-condensing) |
| Weight | 34 kg |
| Dimensions | Not specified |
| Compressed Air Requirement | ASTM D5001-compliant (≤0.1 ppm hydrocarbons), dry and oil-free |
| Deionized Water Reservoir Capacity | ~1000 tests per fill |
| Control | Microprocessor-based, fully automated |
| Environmental Compliance | Designed for ISO/IEC 17025-aligned laboratories |
| Software Interface | PC-based control and data logging with audit-trail capability |
| Brand | Core Separations |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Subcritical Water Extraction System |
| Price Range | USD 210,000 – 280,000 |
| Max Temperature | 400 °C |
| Max Pressure | 550 bar |
| Flow Rate Range | 5–200 g/min |
| Brand | Falex |
|---|---|
| Origin | USA |
| Model | 450-001-002 |
| Heating Tube Temperature Range | 300–450 °C |
| Temperature Control Accuracy | ±2 °C |
| Flow Rate Range | 0.55–10.0 mL/min |
| Pressure Range | 0–200 psi |
| Test Duration | 2.5–500 hours |
| Sample Reservoir Temperature | 100–210 °C |
| Sample Volume | 100 mL–1 L |
| Compliance | SAE ARP 5996B, SAE AS5780 |
| Brand | Tannas&King |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | TanEV WCT |
| Product Type | Laboratory Instrument |
| Compliance | SAE J3200 (in development), ASTM method under preparation |
Show next