| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Japan |
| Model | A12801-01 |
| Mounting | C-mount to C-mount (linear configuration) |
| Input Mount | C-mount (female) |
| Output Mount | C-mount (male) |
| Relay Lens Magnification | 1.0× |
| Field of View (W-VIEW mode) | 13 mm × 6.4 mm |
| Field of View (Bypass mode) | 13 mm × 13 mm |
| Transmission Wavelength Range | 400–800 nm |
| Peak Transmission (Bypass mode) | ≥97% |
| Dichroic Mirror Compatibility | 25.2 mm × 35.6 mm (±0.1 mm, max thickness 2.0 mm) |
| Bandpass Filter Compatibility | Ø25.4 mm (−0/+0.6 mm tolerance, max thickness 6.0 mm) |
| Chromatic Aberration Correction | Integrated achromatizing lens unit for magnification matching between channels |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −10–50 °C |
| Relative Humidity (non-condensing) | ≤70% |
| Mode Switching | Manual dichroic insertion/removal for W-VIEW ↔ Bypass operation |
| Optical Path Geometry | Collinear, symmetric design for upright and inverted microscopes |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Hungary |
| Manufacturer | Mediso Medical Imaging Systems |
| Instrument Type | Nuclear Medicine SPECT Scanner |
| Detector Configuration | Dual-Head, Variable-Angle |
| Acquisition Modes | Planar & Tomographic (SPECT) |
| Key Hardware | Fully Digital High-Resolution Detectors, Integrated Single-Board Electronics, Motorized Collimator Changer, NIR-Based Patient Contour Mapping |
| Field of View (FOV) | ≥530 mm × 390 mm |
| Energy Range | 40–600 keV |
| Intrinsic Spatial Resolution | ≤3.6 mm FWHM |
| Maximum Count Rate | ≥220 kcps |
| Intrinsic Uniformity (Differential/Integral) | ≤1.9% / ≤2.4% |
| Intrinsic Spatial Linearity (Differential/Absolute) | ≤0.18 mm / ≤0.38 mm |
| Gantry Dimensions (L×W×H) | 1160 × 1520 × 1500 mm |
| Total System Weight | 2200 kg |
| Patient Table (L×W×H) | 2000 × 800 × 650 mm |
| Weight | 350 kg |
| Collimator Cart (L×W×H) | 750 × 560 × 1250 mm |
| Weight | 125 kg |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP6601 |
| Type | Single-Head Gamma Camera-Based SPECT System |
| Effective Field of View | ≥510 mm × 390 mm |
| Energy Range | 50–400 keV |
| Intrinsic Spatial Resolution | ≤3.8 mm FWHM |
| Maximum Count Rate | ≥140 kcps |
| Intrinsic Uniformity (Differential) | ≤2.2% |
| (Integral) | ≤2.8% |
| Dimensions (System) | 170 × 183 × 200 cm |
| Weight (System) | 1950 kg |
| Patient Table | 266 × 57 × 65 cm, 250 kg |
| Power Cabinet | 43 × 50 × 96 cm, 47 kg |
| Collimator Cart (Single) | 71 × 83 × 124 cm, 180 kg |
| Software | Full-featured, Chinese-language native interface |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP6602 |
| Type | Compact Planar Gamma Camera for Small-Animal and Human Thyroid/Parathyroid Imaging |
| Origin | Hebei, China |
| Regulatory Approvals | NMPA (ex-SFDA) Certified, FDA 510(k) Cleared |
| Field of View (FOV) | ≥150 mm |
| Energy Range | 70–364 keV (optimized for ⁹⁹ᵐTc, ¹²³I, ¹³¹I) |
| Intrinsic Spatial Resolution | ≤3.8 mm FWHM |
| Maximum Count Rate | ≥150 kcps |
| Intrinsic Uniformity | ≤±3.0% integral, ≤±0.5% differential |
| Intrinsic Spatial Linearity Error | ≤0.4 mm |
| Dimensions (L×W×H) | 1192 × 804 × 1268 mm (low position) / 1468 mm (high position) |
| Weight | 147 kg |
| PACS Integration | Yes |
| Software Interface | Full Chinese GUI with quantitative analysis modules for thyroid area/weight, renal time-activity curves, gated blood pool, and static bone imaging |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BHP6603 |
| Instrument Type | Radionuclide Imaging System |
| Power Supply | 220 V AC ±10%, 50–60 Hz, 8 A, Single-Phase, 1.7 kVA |
| Thermal Dissipation | 5100 kJ/h |
| Operating Temperature | 15–30 °C (59–86 °F), Max Temp. Ramp Rate: ±3 °C/h |
| Relative Humidity | 20–70 % RH |
| System Weight | 1500 kg (3307 lb) |