Add to compare
BrandHamamatsu
OriginJapan
ManufacturerHamamatsu Photonics K.K.
Product TypeResearch-Use-Only (RUO) Digital Pathology Scanner
ModelC13210-01
Imaging ModesBrightfield and Fluorescence
Scan FieldFull-slide panoramic imaging
ThroughputHigh-throughput (up to 60 slides per load)
OperationFully automated
Form FactorBenchtop
Optical Resolution0.46 µm/pixel (20×), 0.23 µm/pixel (40×)
Slide Capacity60 standard slides (26 mm × 76 mm, 0.9–1.2 mm thickness) or 30 dual-format slides (52 mm × 76 mm, optional)
Scan Speed~60 s per 15 mm × 15 mm field at 20×
Objective20× (N.A. 0.75), user-selectable 20×/40× scanning mode
Focus MethodPre-focus map + Z-stack acquisition capability
Barcode ReaderIntegrated 1D barcode scanner (2D optional)
Output FormatJPEG-compressed pyramidal TIFF-compatible tiles with embedded slide metadata
Power SupplyAC 100–240 V, 50/60 Hz
Power Consumption~225 VA
Regulatory StatusRUO in USA, Canada, Israel, Turkey
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu Photonics (BHP)
OriginJapan
ModelA12801-01
MountingC-mount to C-mount (linear configuration)
Input MountC-mount (female)
Output MountC-mount (male)
Relay Lens Magnification1.0×
Field of View (W-VIEW mode)13 mm × 6.4 mm
Field of View (Bypass mode)13 mm × 13 mm
Transmission Wavelength Range400–800 nm
Peak Transmission (Bypass mode)≥97%
Dichroic Mirror Compatibility25.2 mm × 35.6 mm (±0.1 mm, max thickness 2.0 mm)
Bandpass Filter CompatibilityØ25.4 mm (−0/+0.6 mm tolerance, max thickness 6.0 mm)
Chromatic Aberration CorrectionIntegrated achromatizing lens unit for magnification matching between channels
Operating Temperature0–40 °C
Storage Temperature−10–50 °C
Relative Humidity (non-condensing)≤70%
Mode SwitchingManual dichroic insertion/removal for W-VIEW ↔ Bypass operation
Optical Path GeometryCollinear, symmetric design for upright and inverted microscopes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu Photonics (BHP)
OriginHungary
ManufacturerMediso Medical Imaging Systems
Instrument TypeNuclear Medicine SPECT Scanner
Detector ConfigurationDual-Head, Variable-Angle
Acquisition ModesPlanar & Tomographic (SPECT)
Key HardwareFully Digital High-Resolution Detectors, Integrated Single-Board Electronics, Motorized Collimator Changer, NIR-Based Patient Contour Mapping
Field of View (FOV)≥530 mm × 390 mm
Energy Range40–600 keV
Intrinsic Spatial Resolution≤3.6 mm FWHM
Maximum Count Rate≥220 kcps
Intrinsic Uniformity (Differential/Integral)≤1.9% / ≤2.4%
Intrinsic Spatial Linearity (Differential/Absolute)≤0.18 mm / ≤0.38 mm
Gantry Dimensions (L×W×H)1160 × 1520 × 1500 mm
Total System Weight2200 kg
Patient Table (L×W×H)2000 × 800 × 650 mm
Weight350 kg
Collimator Cart (L×W×H)750 × 560 × 1250 mm
Weight125 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu Photonics (BHP)
ModelBHP6601
TypeSingle-Head Gamma Camera-Based SPECT System
Effective Field of View≥510 mm × 390 mm
Energy Range50–400 keV
Intrinsic Spatial Resolution≤3.8 mm FWHM
Maximum Count Rate≥140 kcps
Intrinsic Uniformity (Differential)≤2.2%
(Integral)≤2.8%
Dimensions (System)170 × 183 × 200 cm
Weight (System)1950 kg
Patient Table266 × 57 × 65 cm, 250 kg
Power Cabinet43 × 50 × 96 cm, 47 kg
Collimator Cart (Single)71 × 83 × 124 cm, 180 kg
SoftwareFull-featured, Chinese-language native interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu Photonics
OriginChina (Hebei)
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic
ModelBHP9608
PricingUpon Request
Application DomainResearch
Imaging ModalityBrightfield Scanning
Scan CoverageWhole-Slide Imaging (WSI)
ThroughputHigh-Throughput
Operation ModeFully Automatic
Form FactorBenchtop
Optical Resolution≤0.25 µm/pixel (at 40× objective)
Slide Capacity20-slides per batch
Scan Speed~30 seconds per slide (40×, brightfield)
Loading/Unloading Time≤15 minutes for 20 slides (40×)
Compatible StainerSakura Tissue-Tek® Prisma® 4768 20-slide stainer
Software PlatformNDP.view2 / NDP.scan
ComplianceCE-IVD, ISO 13485, FDA-listed (Class II), GLP/GMP-ready audit trail support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelC15711-02
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelC13220-01
Application FieldResearch
Imaging ModalityBrightfield Scanning
Scan CoverageWhole-Slide Imaging (WSI)
ThroughputHigh-Throughput
Operation ModeFully Automated
Form FactorBenchtop
Spatial Resolution0.23 µm/pixel (40×), 0.46 µm/pixel (20×)
Slide Capacity360 standard glass slides (26 mm × 76 mm, thickness 0.9–1.2 mm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu Photonics (BHP)
ModelBHP6602
TypeCompact Planar Gamma Camera for Small-Animal and Human Thyroid/Parathyroid Imaging
OriginHebei, China
Regulatory ApprovalsNMPA (ex-SFDA) Certified, FDA 510(k) Cleared
Field of View (FOV)≥150 mm
Energy Range70–364 keV (optimized for ⁹⁹ᵐTc, ¹²³I, ¹³¹I)
Intrinsic Spatial Resolution≤3.8 mm FWHM
Maximum Count Rate≥150 kcps
Intrinsic Uniformity≤±3.0% integral, ≤±0.5% differential
Intrinsic Spatial Linearity Error≤0.4 mm
Dimensions (L×W×H)1192 × 804 × 1268 mm (low position) / 1468 mm (high position)
Weight147 kg
PACS IntegrationYes
Software InterfaceFull Chinese GUI with quantitative analysis modules for thyroid area/weight, renal time-activity curves, gated blood pool, and static bone imaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu Photonics (BHP)
OriginHebei, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelBHP6603
Instrument TypeRadionuclide Imaging System
Power Supply220 V AC ±10%, 50–60 Hz, 8 A, Single-Phase, 1.7 kVA
Thermal Dissipation5100 kJ/h
Operating Temperature15–30 °C (59–86 °F), Max Temp. Ramp Rate: ±3 °C/h
Relative Humidity20–70 % RH
System Weight1500 kg (3307 lb)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHamamatsu
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelC13299
PricingUpon Request
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0