| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C11011-01W |
| Pricing | Available Upon Request |
| Measurement Principle | Optical Interferometry (Infrared Coherence-Domain Reflectometry) |
| Light Source | Infrared LED (1300 nm) |
| Spot Size | Ø60 µm |
| Working Distance | 155 mm (optional C11011-01WL: 1000 mm) |
| Thickness Range (SiO₂ on Glass) | 25 µm – 2900 µm |
| Thickness Range (Si on SiO₂/Si substrate) | 10 µm – 1200 µm |
| Repeatability (Si film, 6 µm nominal) | ±100 nm (1σ) |
| Accuracy (Si film) | ±0.5 µm for t < 500 µm |
| Measurement Speed | 60 Hz (22.2 ms per point, acquisition only) |
| Layer Capability | Single-layer standard |
| Detection Method | Peak-detection algorithm applied to interference fringe envelope |
| Output Interface | RS-232C, PIPE, USB 2.0 |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 50 W |
| Compliance | CE-marked |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | C9692 |
| Pricing | Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C7700-01 |
| Price | Upon Request |
| Spectral Response Range | 200 nm – 850 nm |
| Time Resolution | < 5 ps |
| Scan Repetition Rate | Single-shot to 1 kHz (max) |
| Dynamic Range | > 1:1000 (up to 10,000:1 under optimized conditions) |
| Sweep Duration | 500 ps – 1 ms |
| Effective Photocathode Length | 17 mm |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Control Interface | IEEE-488 (GPIB) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model Series | Quantaurus-Tau |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer | Hamamatsu Photonics K.K. |
| Type | Imported Instrument |
| Model | C10178-01 |
| Light Source | Halogen Lamp |
| Wavelength Range | 400 nm to 1100 nm |
| Spot Size | Approx. φ1 mm |
| Working Distance | 10 mm |
| Measurable Thickness Range (on Glass Substrate) | 20 nm to 50 µm |
| Thickness Repeatability (SiO₂, 400 nm) | 0.01 nm |
| Thickness Accuracy (on Glass) | ±0.4 % |
| Maximum Detectable Layers | 10 |
| Analysis Methods | FFT-based Interference Analysis, Curve Fitting, Complex Refractive Index (n, k) Modeling |
| Measurement Speed | 19 ms per point (acquisition only) |
| Fiber Interface | φ12 mm Sleeve-Type |
| Communication Interfaces | RS-232C, PIPE, Ethernet, USB 2.0 |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz |
| Power Consumption | 250 W |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | C11209-110 |
| Pricing | Upon Request |
| Sensor Type | Non-cooled MPPC (S12571-010C) |
| Active Area | 1 × 1 mm² |
| Pixel Count | 10,000 |
| Pixel Pitch | 10 µm |
| Operating Voltage | +5 V DC |
| Spectral Response Range | Enhanced short-wavelength sensitivity (peak ~420 nm) |
| Temperature Compensation | Integrated analog circuitry |
| Package Dimensions | Compact OEM module (see mechanical drawing per datasheet) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer | Hamamatsu Photonics K.K. |
| Type | Imported Instrument |
| Model | C11665-01 |
| Light Source | LED (940–1000 nm) |
| Measurable Thickness Range (Glass) | 0.5 µm to 700 µm |
| Measurable Thickness Range (Silicon) | 0.5 µm to 300 µm |
| Repeatability (Si, 6 µm film) | ±0.1 nm |
| Accuracy (Si) | ±1 % (within calibration standard traceability) |
| Spot Size | Approx. φ1 mm |
| Working Distance | 5 mm |
| Max. Analyzable Layers | 10 |
| Analysis Methods | FFT-based interference fringe analysis, multi-layer optical modeling, n/k dispersion fitting |
| Measurement Time per Point | 19 ms (acquisition only, excluding computation) |
| Fiber Interface | FC-type |
| External Control | RS-232C and Ethernet |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 85 W |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | C6138 |
| Pricing | Available Upon Request |
| Spectral Response Range | 280–850 nm |
| Temporal Resolution | 200 fs (typical) |
| Scan Repetition Rate | Single-shot to 100 Hz (max) |
| Dynamic Range | >1:10 |
| Sweep Duration | 20 ps – 1 ns |
| Effective Photocathode Length | 3 mm |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Interface | GPIB (with HPD-TA readout system) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C11627-01 |
| Price | Upon Request |
| Measurement Principle | Spectral Interferometry (White-Light Coherence Scanning) |
| Measurable Thickness Range (on Glass Substrate) | 20 nm to 50 µm |
| Repeatability (SiO₂, 400 nm film) | 0.02 nm (1σ) |
| Accuracy (Glass Substrate) | ±0.4 % (per VLSI Standard Calibration Certificate) |
| Light Source | Broadband LED |
| Wavelength Range | 420 nm – 720 nm |
| Spot Size | Approx. Ø1 mm |
| Working Distance | 10 mm |
| Max. Detectable Layers | 10 |
| Analysis Methods | FFT-based Coherence Peak Detection, Least-Squares Curve Fitting, Refractive Index (n) & Extinction Coefficient (k) Extraction |
| Measurement Speed | 19 ms per data point (acquisition only, excluding analysis) |
| Fiber Interface | FC-type |
| External Control Interfaces | RS-232C, Ethernet |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | 70 W |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C11293-02 |
| Price | Upon Request |
| Spectral Response Range | 1000 nm – 1650 nm |
| Time Resolution | <20 ps |
| Scan Repetition Frequency | 20 MHz |
| Scan Duration Range | 1 ns – 10 ms |
| Effective Photocathode Length | 4.5 mm |
| Photocathode Material | InP/InGaAs |
| Photocathode Operating Temperature | −100 °C |
| Cooling Method | Thermoelectric + Optional Cryogenic Support |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C9536 |
| Price | Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Category | Streak Camera Series |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer | Hamamatsu Photonics K.K. |
| Type | Imported Instrument |
| Model | C11295 |
| Pricing | Upon Request |
| Measurement Principle | Spectral Coherence Interferometry |
| Max. Measurement Points | 15 |
| Thickness Range (on glass, SiO₂-equivalent) | 20 nm to 100 μm |
| Repeatability (400 nm SiO₂ film) | 0.02 nm (1σ) |
| Accuracy (on glass) | ±0.4 % |
| Wavelength Range | 320 nm – 1000 nm |
| Spot Size | Approx. φ1 mm |
| Working Distance | 10 mm |
| Max. Layers Analyzable | 10 |
| Analysis Methods | FFT-based spectral analysis & optical model fitting |
| Measurement Time per Point | 19 ms (acquisition only) |
| Light Source | Xenon lamp |
| Fiber Interface | SMA |
| External Control Interfaces | Ethernet, USB 2.0 (main unit), RS-232C (light source) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Power Consumption | ~330 W (2-channel) to ~450 W (15-channel) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer | Hamamatsu Photonics K.K. |
| Type | Imported Instrument |
| Model | C10910 |
| Pricing | Upon Request |
| Spectral Response | 200–850 nm |
| Time Resolution | <1 ps to <20 ps (depending on scan unit) |
| Scan Repetition Rate | Single-shot to 250 MHz |
| Scan Duration Range | 100 ps to 1 ms |
| Dynamic Range | >1:25 to >1:1000 |
| Effective Photocathode Length | 4.42 mm |
| Power Supply | AC 100–240 V, 50/60 Hz |
Show next