- All
- Favorite
- Popular
- Most rated
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Model | RTK-PC-1 |
| Maximum Pressure | 4.0 GPa |
| Pressure Range | 0.3 MPa – 4.0 GPa |
| Sample Diameter | 3–7 mm |
| Temperature Range | Ambient – 1600 °C |
| Temperature Control Accuracy | ±1 °C |
| Pressure Control Accuracy (with auto-pressurization) | ±0.03 GPa |
| System Type | Static High-Pressure Piston-Cylinder |
| Frame Load Capacity | 100-ton hydraulic press |
| Vacuum Capability | Not applicable (GPa misassigned |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Software | RTK PC Control Suite (Windows-based, real-time pressure/temperature logging, audit trail enabled) |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Model | Rocktek-1 |
| Max Operating Temperature | 1800 °C |
| Max Static Pressure | 4 GPa |
| Heating Method | Resistive (Graphite or Ceramic Heating Elements) |
| Pressure Generation | Hydraulic or Mechanical Piston-Based Static Press System |
| Compliance | Designed for laboratory-scale static high-pressure synthesis per ASTM E2567 and ISO 13320 principles (application-specific calibration required) |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK Rapid Thermal Flash Sintering System |
| Heating Element | Silicon Molybdenum (MoSi₂) Rods |
| Maximum Temperature | ≤1600 °C (1 h rating) |
| Operating Temperature Range | Up to 1550 °C |
| Temperature Uniformity Zone | 150 mm (within ±1 °C) |
| Heating Zone Length | 300 mm |
| Tube Dimensions | Alumina (99.7% Al₂O₃), Ø100 mm |
| Vacuum Performance | Ultimate Pressure ≤2×10⁻³ mbar, Pumping Speed 16.5 m³/h |
| Insulation | High-Purity Alumina Fiber Blanket |
| External Casing | Dual-Layer Water-Cooled Stainless Steel Shell (Surface Temp. <60 °C) |
| Viewing Port | Integrated Quartz Observation Window on Inlet Flange |
| Temperature Monitoring | Dual-Channel IR Pyrometer (Sample Surface) + Thermocouple (Furnace Ambient) |
| Power Supply Interface | Programmable DC Source (Voltage/Current Setpoint, Ramp Control) |
| Data Acquisition | 50 ms Sampling Interval, Real-Time V–t / I–t Plotting, Excel Export (CSV-compatible) |
| Control Architecture | PID + Programmable Ramp-Soak Profiles |
| Software Compliance | Audit Trail Ready, Timestamped Event Logging, Configurable Communication Protocols (RS485/Modbus TCP) |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK1000 |
| Pressure Control Accuracy | ±10 PSI |
| Max Sample Pressure | >20 GPa |
| Max Sample Temperature | >2000 °C |
| Temperature Accuracy | ±1 °C |
| Control Architecture | PLC-Based Closed-Loop Servo System with Ethernet Communication |
| Programmable Segments | 9-Step Pressure-Time Profile |
| Drive Mechanism | Dual-Mode — Hydraulic (Low-Pressure Rapid Stroke) + Precision Servo Motor (High-Pressure Fine Regulation) |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Model | RTK-003 |
| Max Operating Temperature | 2000 °C (Rated: 2100 °C) |
| Temperature Control | Single-zone PID |
| Ramp Rate | 0–20 °C/min (adjustable) |
| Ultimate Vacuum | ≤30 Pa (achieved within ≤30 min) |
| Pressure Rise Rate | ≤0.65 Pa/h |
| Heating System | Cage-type graphite heater |
| Cooling Method | Forced recirculating water cooling (furnace shell, top/bottom flanges, copper electrodes, cables) |
| Control Architecture | Industrial PC + high-performance hybrid logic controller |
| Operation Modes | Fully automatic / local manual |
| Data Logging | Real-time acquisition of temperature, vacuum pressure, runtime |
| Compliance Support | GLP-compliant data integrity (audit trail, user access control, electronic signature readiness per FDA 21 CFR Part 11) |
| Brand | Rocktek |
|---|---|
| Model | DIA / D-DIA |
| Type | Kawai-Style Multi-Anvil Apparatus |
| Maximum Load Capacity | 1000–2000 metric tons |
| Sample Pressure Range | >20 GPa |
| Sample Temperature Range | >2000 °C |
| Anvil Material | Tungsten Carbide (WC) |
| Stroke | 150 mm |
| Low-Pressure Drive | Hydraulic System |
| High-Pressure Fine Control | Servo-Motor-Driven with PLC Feedback Loop |
| Pressure Control Accuracy | ±0.5 bar |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Model | RTK-PC-2 |
| Pressure Range | 0–4 GPa |
| Temperature Range | 25–1800 °C |
| Chamber Diameter Options | 10 / 13 / 19 mm |
| Automation | Fully Automated Pressure Ramp & Hold |
| Heating/Cooling Rate Control | Yes |
| Continuous Operation Duration | Hours to Days |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Model | RTK-Kawai Large-Volume Multi-Anvil Press |
| Maximum Load Capacity | 1000–2000 metric tons |
| Maximum Pressure | >20 GPa |
| Maximum Temperature | >2000 °C |
| Anvil Material | Tungsten Carbide (WC) |
| Stroke | 150 mm |
| Low-Pressure Drive | Hydraulic System |
| High-Pressure Regulation | Servo-Motor-Controlled Precision Actuation |
| Pressure Control Accuracy | ±0.5 bar |
| Control Architecture | PLC-Based Segmented Programmable Logic with Real-Time Digital Pressure Feedback |
| Communication Interface | Ethernet (TCP/IP) to Host PC |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Brand | Rocktek |
|---|---|
| Model | Kawai-01 |
| Type | Walker-Type Multi-Anvil High-Pressure Apparatus |
| Maximum Pressure | >20 GPa |
| Maximum Temperature | >2000 °C |
| Press Capacity | 1000–2000 metric tons |
| Stroke | 50 mm |
| Pressure Control Accuracy | ±0.5 bar |
| Low-Pressure Drive | Hydraulic System |
| High-Pressure Fine Control | Servo Motor + PLC |
| Pressure Sensing | Digital Pressure Transducer |
| Communication Interface | Ethernet-based Industrial Protocol |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Origin | Wuhan, Hubei, China |
| Manufacturer Role | Authorized Distributor |
| Brand | Rocktek |
|---|---|
| Origin | Wuhan, Hubei, China |
| Manufacturer | Hubei Rocktek Instrument Co., Ltd. |
| Configuration | Kawai-type 6–8 anvil assembly |
| Max. Load Capacity | 1000–2000 tons |
| Max. Sample Pressure | >20 GPa |
| Max. Sample Temperature | >2000 °C |
| Piston Stroke | 150 mm |
| Low-Pressure Drive | Hydraulic system |
| High-Pressure Regulation | Servo-motor-controlled with PLC |
| Pressure Control Accuracy | ±0.5 bar |
| Control Interface | Ethernet-enabled digital pressure sensor feedback loop |
| Compliance | Designed for GLP-compliant research environments |
| Software Integration | Real-time pressure/time profiling with event logging and remote monitoring capability |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK04 |
| Pricing | Upon Request |
| Pressure Range | 0–4 GPa |
| Temperature Range | 25–1800 °C |
| Sample Chamber Diameter Options | 10 mm / 13 mm / 19 mm |
| Continuous Operation Duration | Hours to Multiple Days |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Cubic-01 |
| Pricing | Available Upon Request |
| Pressure Generation Principle | DIA-type Multi-Anvil Apparatus |
| Maximum Pressure | >20 GPa |
| Maximum Temperature | >2000 °C |
| Load Capacity Options | 1000 ton / 2000 ton |
| Low-Pressure Drive | Hydraulic System |
| High-Pressure Regulation | Servo-Motor-Controlled Precision Actuation |
| Pressure Control Accuracy | ±0.5 bar |
| Control Architecture | PLC-Based Segmented Programmable Logic with Real-Time Digital Pressure Feedback |
| Communication Interface | Ethernet (Modbus TCP / OPC UA compatible) |
| Operating Mode | Fully Automated Closed-Loop Pressure & Time Profiling |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | RTK-ZYJ01 |
| Pricing | Available Upon Request |
| Maximum Pressure (Piston-Cylinder) | 2.0 GPa |
| Maximum Pressure (Bridgman Anvil) | 5.0 GPa |
| Temperature Range (Piston-Cylinder) | Up to 1600 °C |
| Temperature Range (Bridgman Anvil) | Up to 1000 °C |
| Sample Dimensions (Piston-Cylinder) | Ø4 × 6 mm |
| Sample Dimensions (Bridgman Anvil) | Ø5 × 1.8 mm |
| Pressure Rise Time | ≤20 ms |
| Pressure Ramp Rate (Piston-Cylinder) | 1–2 GPa/20 ms |
| Pressure Ramp Rate (Bridgman Anvil) | 3–10 GPa/20 ms |
| Brand | Rocktek |
|---|---|
| Model | RTK-PC-II |
| Origin | Hubei, China |
| Maximum Pressure | 4.5 GPa |
| Pressure Control Accuracy | ±0.03 GPa |
| Temperature Range | Ambient to 1600 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Diameter | 3–7 mm |
| Drive System | Dual-piston hydraulic actuation via 250 T / 300 T press |
| Control Interface | RTK PC Software with real-time pressure & temperature monitoring |
| Safety Features | Overpressure protection, thermal overload cutoff, chiller interlock |
| Brand | Rocktek |
|---|---|
| Origin | Hubei, China |
| Model | RTK Piston-Cylinder High-Pressure Apparatus (Automated) |
| Pressure Range | 0–4 GPa |
| Temperature Range | 25–1800 °C |
| Sample Chamber Diameter Options | 10 / 13 / 19 mm |
| Automation | Fully automated pressure ramping and isobaric hold |
| Thermal Ramp & Cool-down Rate | Programmable |
| Continuous Operation Duration | Hours to multi-day stable runs |
| Compliance | Designed for GLP-aligned research environments |
Show next
