- All
- Favorite
- Popular
- Most rated
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | TDZ6-WS |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–6000 rpm |
| Max RCF | 4800 × g |
| Max Capacity | 4 × 100 mL |
| Rotor Configuration | Horizontal Swing-Out |
| Application Class | Cell & Bacterial Separation |
| Drive System | Brushless Frequency-Controlled Motor |
| Control Interface | TFT Color Touchscreen + Digital Display |
| Acceleration/Deceleration Profiles | 10 selectable ramps |
| Stored Programs | 20 user-defined protocols |
| Timer Range | 0–99 h 59 min, continuous, or momentary spin |
| Power Consumption | 500 W |
| Noise Level | ≤65 dB(A) |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Electrical Supply | AC 220 V, 50 Hz |
| Rotor Recognition | Visual on-screen rotor diagram display |
| Safety Features | Automatic imbalance detection, motorized safety door lock, stainless steel chamber, multi-stage vibration damping system |
| Brand | Hesiyi |
|---|---|
| Model | 3H24RI |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 24,000 rpm |
| Max RCF | 41,470 ×g |
| Max Capacity | 4 × 100 mL |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10 selectable rates |
| Noise Level | ≤60 dB(A) |
| Power Supply | 220 V, 50 Hz |
| Dimensions (L×W×H) | 710 × 630 × 350 mm |
| Weight | 75 kg |
| Refrigerant | R404a (non-CFC) |
| Rotor Recognition | Automatic |
| Display | 4.3″ TFT color touchscreen |
| Programmable Methods | 100 stored protocols |
| Motor | Brushless DC frequency-controlled motor |
| Safety | Triple-layer steel rotor chamber, imbalance detection, overspeed protection, overtemperature cutoff, auto-lock door mechanism |
| Brand | Hexi |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | RH2010SF-I |
| Price Range | USD 4,200–7,000 |
| Moisture Measurement Range | 40%–97% (w/w) |
| Accuracy | ±2% of reading |
| Display | TFT-LCD digital interface |
| Single-Measurement Duration | 5–6 s |
| Net Weight | 7 kg |
| Dimensions | 340 × 240 × 200 mm |
| Portability | Integrated carrying handle |
| Compliance Standard | Q/AELE 003–2020 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model Series | ATX & ATY |
| Measurement Principle | Electromagnetic Force Compensation (EMFC) |
| Max Capacity | 220 g (ATX224/ATY224) to 62 g (ATY64) |
| Minimum Readability | 0.1 mg |
| Repeatability | ±0.1 mg |
| Linearity Error | ±0.2 mg |
| Stabilization Time | ≤2.5 s |
| Pan Size | 91 mm diameter |
| Calibration | Internal Auto-Calibration with External Weights |
| Compliance | ISO/IEC 17025, ASTM E898, USP <41>, GLP/GMP-ready |
| Interface | RS-232, USB (optional), Direct Windows Data Transfer (No Driver Required) |
| Environmental Adaptation | Adjustable Filter Settings (Stability/Response Trade-off) |
| Sensor Architecture | Monolithic UniBloc Dual-Lever EMFC Sensor |
| [Brand | Heshi |
|---|---|
| Origin | Hunan, China |
| Model | xiti-HT12MM |
| Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 2200 ×g |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1 min – 99 h 59 min |
| Motor | High-Torque Brushless DC Motor |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 120 W |
| Dimensions (W×D×H) | 550 × 440 × 330 mm |
| Weight | 35 kg |
| Rotor Capacity | 12 × 15 mL tubes |
| Rotor Types | SERO rotor (4000 rpm / 1842 ×g), HLS rotor (4200 rpm / 2200 ×g) |
| Compliance | Designed for GLP-compliant clinical and research workflows] |
| Brand | HEREXI |
|---|---|
| Origin | Hunan, China |
| Model | H/T12MM |
| Centrifuge Type | Benchtop Low-Speed Centrifuge |
| Maximum Capacity | 12 microtubes or 12 blood typing cards (6- or 8-column gel cards) |
| Max Speed | 4000 rpm |
| Max RCF | 2200 ×g |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Weight | 35 kg |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 200 W |
| Rotor Types | SERO rotor (for RBC washing and serology), HLS rotor (for lymphocyte separation), Blood Typing Card rotor (for 6-/8-column microgel cards and 24-well formats) |
| Control System | Microprocessor-based with automatic imbalance detection |
| Compliance | Designed for GLP-compliant clinical laboratories performing immunohematology testing per CLSI EP12-A2 and ISO 15189 requirements |
| Brand | Denver |
|---|---|
| Origin | USA |
| Model | MXX Series Portable Electronic Balance |
| Capacity Range | 210 g to 10,000 g |
| Readability | 0.01 g to 1 g |
| Pan Size | Ø97 mm or 142 × 130 mm |
| Repeatability | ≤ ±0.01 g to ±1 g |
| Linearity | ≤ ±0.03 g to ±2 g |
| Power | AC adapter or rechargeable battery |
| Display | Backlit LCD |
| Interface | RS232 or USB (optional) |
| IP Rating | Splash-resistant sealed keypad |
| Pan Material | Stainless steel |
| Built-in applications | Counting, Percentage weighing, Hold function, Formula summation, Density determination, Unit conversion |
| [Brand | HeXi |
|---|---|
| Model | LT5Y |
| Type | Floor-standing Low-speed Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 4500 ×g |
| Max Capacity | 4 × 100 mL (horizontal rotor) |
| Temperature Range | Ambient to 70 °C |
| Temp. Accuracy | ±2 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1 min – 99 h 59 min |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 600 × 490 × 760 mm |
| Weight | 70 kg |
| Compliance | GB/T 6533–2012, IEC 61131-2:2007, EN 61000-6-3:2011 (EMC), CE, NEMA 4-rated HMI] |
| Brand | Herexi |
|---|---|
| Origin | Hunan, China |
| Model | HR/T16MM |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 16,500 rpm) |
| Max. Capacity | 24 × 1.5/2.0 mL |
| Max. RCF | 18,780 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 680 × 350 × 300 mm |
| Certifications | CFDA Registered & Manufactured, ISO 9001:2015, ISO 13485:2016 |
| Rotor Material | Forged Aviation-Grade Aluminum |
| Refrigerant | R404a (non-ozone-depleting) |
| Safety | Airtight Biocontainment Rotor with RoHS 2015/863–compliant Silicone Seal, Triple-Layer Steel Protection, Automatic Motor-Driven Door Lock, Real-time Imbalance Detection, Over-speed/Over-temp/Under-voltage/Over-voltage Protection |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LT7Y |
| Instrument Type | Floor-standing Centrifuge |
| Speed Class | Low-speed Centrifuge (≤5000 rpm) |
| Function | Standard Centrifuge for ASTM D95 / GB/T 6533-2012 Compliance |
| Configuration | Horizontal Swing-out Rotor |
| Maximum Capacity | 4 × 4 × 100 mL |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4500 × g |
| Dimensions (W×D×H) | 600 × 490 × 760 mm |
| Weight | 270 kg |
| Temperature Control Range | Ambient to 70 °C |
| Temperature Accuracy | ±2 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1 min – 99 h 59 min (continuous & short-spin modes) |
| Noise Level | ≤65 dB(A) |
| Drive System | High-torque AC/DC brushless frequency-converter motor with microprocessor control |
| Control Interface | Mitsubishi PLC (IEC 61131-2:2007, EMC Directive 2014/30/EU) + Weinview HMI (NEMA 4, CE certified) |
| Chamber Material | Austenitic 304 stainless steel |
| Safety | Triple-layer steel protective housing, automatic rotor imbalance detection, dual-damping suspension, interlocked motorized door lock (NEMA 4-rated), adjustable leveling feet with casters |
| Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registration & Manufacturing License |
| [Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | LR8M |
| Type | Floor-Standing Refrigerated Centrifuge |
| Max Capacity | 4 × 150 mL (horizontal) / 6 × 1000 mL (horizontal) |
| Max Speed | 8,000 rpm |
| Max RCF | 11,377 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Programs Stored | 16 user-defined |
| Display | TFT-LCD touch interface with multilingual support (EN/CN) |
| Noise Level | <65 dB(A) |
| Dimensions (W×D×H) | 840 × 730 × 950 mm |
| Weight | 270 kg |
| Power Supply | AC 220 V / 50 Hz |
| Total Power | 4.0 kW |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Refrigerant | R404a (non-ozone-depleting) |
| Motor | High-torque AC frequency-controlled motor |
| Control System | Mitsubishi PLC (IEC 61131-2:2007 compliant), Weinview HMI (NEMA4, CE certified)] |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Product Line | UX Series |
| Measurement Principle | Electromagnetic Force Compensation (EMFC) |
| Response Time (UX-S models) | 0.7 s |
| Display Resolution | 0.001 g to 0.1 g |
| Weighing Pan Dimensions | 108 × 105 mm or 170 × 180 mm |
| Power Consumption | ≤12 VA |
| Unit Modes | g, ct, %, pcs, dwt, oz, lb, etc. |
| Compliance | ISO 9001–certified manufacturing |
| Brand | Hercy |
|---|---|
| Origin | Hunan, China |
| Model | CGF-TD4 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–3100 rpm |
| Max RCF | 3100 × g |
| Max Capacity | 8 × 10 mL |
| Rotor Type | Fixed-Angle Rotor |
| Application Class | Cellular/Bacterial Separation |
| Dimensions (L×W×H) | 380 × 260 × 310 mm |
| Weight (incl. rotor) | 17 kg |
| Power Supply | AC 220 V, 50 Hz |
| Speed Accuracy | ±30 rpm |
| Noise Level | ≤60 dB(A) |
| Operating Environment | 5–40 °C, RH ≤80%, non-corrosive/non-explosive atmosphere |
| Compliance | Designed for GLP-aligned dental regenerative workflows |
| Software Features | 4 pre-programmed CGF protocols (CGF-S1×4), A-PRF-S2, i-PRF-S3, PGRF-S4, auto-RCF calculation, parameter memory, TFT color touch interface |
| Drive System | Brushless DC inverter motor with PWM speed control |
| Safety | Interlocked motorized door, automatic imbalance detection & auto-balance compensation, steel chassis with epoxy powder coating |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TDL6M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Class | Low-Speed Centrifuge (max 6500 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Separation Target | Biological Macromolecules |
| Max Capacity | 4 × 500 mL |
| Max Speed | 6500 rpm |
| Max RCF | 4800 × g |
| Dimensions | 630 × 760 × 400 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp Control Accuracy | ±1 °C |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Motor | High-Torque Brushless Frequency-Controlled AC Motor |
| Drive & Control | Microprocessor-Based Digital Control System |
| Acceleration/Deceleration | 10 Adjustable Ramp Profiles |
| Programmable Protocols | 20 Predefined & User-Editable Methods |
| Display | 4.3-inch TFT True-Color Touchscreen with Dual Touch/Keypad Interface |
| Data Logging | Automatic Run Parameter Recording (Time, Speed, RCF, Temp, Rotor ID) |
| Rotor Recognition | Manual Input (No Auto-ID Sensor) |
| Construction | Full Steel Frame with Stainless Steel Centrifuge Chamber |
| Door Lock | Electromechanical Quiet-Lock System |
| Weight | 110 kg |
| Rated Power | 1.8 kW |
| Brand | Hershey |
|---|---|
| Model | ES5000-2 |
| Max Capacity | 5000 g |
| Readability | 1 g |
| Repeatability | 1 g |
| Linearity | ±1 g |
| Stabilization Time | 1.5 s |
| Operating Temperature | 10–35 °C |
| Power Supply | AC 220 V, 50 Hz |
| Pan Dimensions (per pan) | 175 × 175 mm |
| Environmental Compliance | Designed for ISO 13485-aligned blood bank environments |
| Calibration | Manual |
| Built-in Counterweight Set | 49 g total (2×3 g, 2×4 g, 1×5 g, 1×10 g, 1×20 g), silicone-rubber encapsulated, non-toxic, certified to ≤0.1 g per piece accuracy |
| Brand | HEREXI |
|---|---|
| Origin | Hunan, China |
| Model | TD5A |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–5500 rpm |
| Max RCF | 4800 ×g |
| Max Capacity | 4 × 250 mL |
| Rotor Types | Fixed-Angle & Swinging-Bucket Rotors |
| Display | 4.3″ TFT True-Color Touchscreen |
| Control System | Microprocessor-Controlled Brushless Frequency-Conversion Motor |
| Acceleration/Deceleration Profiles | 10 Adjustable Steps |
| Programmable Methods | 20 User-Defined Protocols |
| Timer Range | 0–99 h 59 min |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Net Weight | 35 kg |
| Chamber Material | Stainless Steel (AISI 304) |
| Safety Certification | CE-compliant design per IEC 61010-2-020 |
| Brand | Herx |
|---|---|
| Origin | Hunan, China |
| Model | TDZ4 Dental & Oral Implant Medical Centrifuge |
| Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 2600 ×g |
| Max Capacity | 24 × 10 mL |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤60 dB(A) |
| Dimensions (L×W×H) | 500×450×280 mm |
| Weight (with rotor) | 20 kg |
| Power Supply | AC 220 V, 50 Hz |
| Motor | High-torque brushless DC motor |
| Control System | Microprocessor-based with TFT-LCD touchscreen + physical keys |
| Certifications | CFDA registered, ISO 13485:2016 & ISO 9001:2015 compliant |
| Safety | RoHS-compliant silicone sealing gasket, 304 stainless steel centrifuge chamber, triple-layer steel protection housing, auto-locking lid mechanism |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich HR/T16M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | General-Purpose Refrigerated Centrifugation |
| Configuration | Fixed-Angle Rotor System |
| Max Capacity | 4 × 100 mL |
| Max Speed | 16,000 rpm |
| Max RCF | 19,600 × g |
| Dimensions | 710 × 630 × 350 mm |
| Refrigeration | R404a refrigerant with imported non-CFC compressor |
| Temp Range | −20 °C to +40 °C |
| Temp Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step programmable |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Weight | 73 kg |
| Certifications | CFDA Registered & Manufactured, ISO 9001:2015, ISO 13485:2016 |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TDZ5-WS |
| Instrument Type | Benchtop Centrifuge |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 4800 × g |
| Speed Accuracy | ±50 rpm |
| Timer Range | 0–99 h 59 min |
| Number of Presets | 20 |
| Drive System | AC Brushless Inverter Motor |
| Control System | Microprocessor-Based with TFT Touchscreen Display |
| Chamber Material | Stainless Steel (304) |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Weight | 25 kg |
| Noise Level | ≤65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Total Power | 350 W |
| Acceleration/Deceleration Profiles | 10-step selectable |
| Rotor Types | Fixed-angle and Swing-out Configurations |
| Rotor Compatibility | 12 × 15 mL, 18 × 10 mL, 24 × 10 mL, 4 × 50 mL, 4 × 100 mL, 16 × 15 mL, 24 × 5 mL (vacutainer) |
| Brand | Hesii |
|---|---|
| Origin | Hunan, China |
| Model | TD5A |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 4000 rpm |
| Maximum RCF | 2100 ×g |
| Maximum Capacity | 4 × 50 mL |
| Acceleration/Deceleration | 10-step programmable |
| Timer Range | 1 min – 99 h 59 min, continuous, or short-spin mode |
| Speed Accuracy | ±50 rpm |
| Drive System | High-torque brushless DC frequency-controlled motor |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 600 × 540 × 360 mm |
| Weight | 35 kg |
| Certifications | CFDA备案 & production license, ISO 9001:2015, ISO 13485:2016 |
| Rotor Compatibility | Sterilizable angular rotors for 10 mL, 20 mL, and 50 mL Luer-lock syringes |
| Brand | Herxi |
|---|---|
| Origin | Hunan, China |
| Model | TDZ4-WS |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 4000 rpm |
| Max RCF | 2650 ×g |
| Max Capacity | 4 × 100 mL |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Motor | High-Torque Brushless DC Motor |
| Control System | Microprocessor-Based with TFT-LCD Touch + Keypad Interface |
| Acceleration/Deceleration | 10-step programmable |
| Programmable Methods | 20 user-defined protocols |
| Safety Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registered |
| Compliance | RoHS 2015/863 (Seal Material), GLP-Compatible Audit Trail Logging Enabled |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | TDZ4 |
| Centrifuge Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 4000 rpm |
| Max RCF | 2320 ×g |
| Max Capacity | 4 × 100 mL (or 12 × 20 mL / 18 × 10 mL / 24 × 10 mL) |
| Speed Accuracy | ±30 rpm |
| Timer Range | 0–99 h 59 min / Continuous / Short-Term Spin |
| Noise Level | ≤60 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight (with rotor) | 20 kg |
| Dimensions (L×W×H) | 500 × 450 × 280 mm |
| Drive System | Brushless Frequency-Controlled Motor |
| Control Interface | TFT True-Color Touchscreen |
| Safety Features | Electromechanical Door Lock, Stainless Steel Chamber, Multi-Stage Damping System, Automatic Rotor Balance Detection |
| Programmability | 20 User-Defined Protocols |
| Construction | Full Steel Frame, Ergonomic Streamlined Housing |
| Brand | Hettich |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Hettich HR20M |
| Instrument Type | Floor-Standing Centrifuge |
| Speed Range | 10,000–30,000 rpm (High-Speed) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 6 × 500 mL |
| Max Speed | 20,000 rpm |
| Max RCF | 48,745 × g |
| Dimensions | 840 × 730 × 960 mm |
| Temperature Range | −20 °C to +40 °C |
| Refrigerant | R404a (non-ozone-depleting, EPA SNAP-approved) |
| Control System | Mitsubishi PLC (compliant with EU EMC Directive 2014/30/EU & IEC 61131-2:2007), Weintek HMI (NEMA 4-rated, CE-certified) |
| Safety Certifications | ISO 9001:2015, ISO 13485:2016, CFDA Registration & Manufacturing License |
| Rotor Material | Aerospace-grade forged aluminum (angle rotors only) |
| Sealing | Integrated silicone O-ring (RoHS 2015/863 compliant) |
| Drive | High-torque AC frequency-controlled motor |
| Braking | 10-step programmable deceleration |
| Acceleration | 10-step programmable acceleration |
| Programs | 16 user-defined protocols |
| Data Display | Real-time curves for speed ramping, RCF integration, and temperature profiling |
| Structural Integrity | Triple-damping system, stainless-steel centrifuge chamber, three-layer steel safety housing, mechanical door interlock |
| Mobility | Dual-position casters with leveling feet |
| Brand | Hershey |
|---|---|
| Origin | Hunan, China |
| Model | HR21M |
| Instrument Type | Floor-standing centrifuge |
| Speed Range | 10,000–30,000 rpm (max 21,000 rpm) |
| Refrigerated | Yes |
| Configuration | Horizontal rotor compatible |
| Max Capacity | 4 × 1000 mL |
| Max RCF | 53,741 × g |
| Dimensions | 820 × 710 × 950 mm |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Acceleration/Deceleration | 10-step control |
| Programs | 16 user-defined |
| Noise Level | ≤65 dB(A) |
| Power | 4.0 kW |
| Weight | 240 kg |
| Compliance | ISO 9001:2015, ISO 13485:2016, CFDA registered |
| Safety | RoHS-compliant silicone sealing, NEMA4-rated HMI, CE/EMC (2014/30/EU), IEC 61131-2:2007, mechanical door lock, triple-damping suspension |
Show next