| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabStart-aw |
| Instrument Type | Portable |
| Measurement Range | 0.030–1.000 aw |
| Accuracy | ±0.01 aw |
| Temperature Range | 15–30 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Backlit LCD (shows aw, temperature, RH%) |
| Weight | 1 kg |
| Sample Cup Capacity | 20 reusable cups included |
| Calibration Standard | Non-consumable, multi-year service life |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabStart-aw |
| Measurement Range | 0.030–1.000 aw |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Sensor Type | CM-4 Capacitive Electrolyte Sensor |
| Temperature Control | None (ambient measurement only) |
| Temperature Range for Measurement | 15–30 °C |
| Temperature Accuracy | ±0.3 K |
| Resolution | 0.01 aw |
| Accuracy | ±0.03 aw |
| Display | Backlit LCD (aw, °C, %RH) |
| Sample Cups | 20 reusable stainless-steel cups included |
| Data Storage | None (real-time readout only) |
| Power Supply | 90–264 VAC, 50–60 Hz |
| Dimensions (H×W×D) | 85 × 140 × 225 mm |
| Weight | 1.2 kg |
| Brand | NovaSina |
|---|---|
| Origin | Switzerland |
| Model | LabSwift-aw |
| Instrument Type | Portable |
| Measurement Range | 0.03–1.000 a<sub>w</sub> |
| Accuracy | ±0.001 a<sub>w</sub> |
| Temperature Operating Range | 5–45 °C |
| Host Weight | 1.2 kg |
| Calibration | Factory-performed 6-point calibration |
| Data Storage | Integrated SD card |
| Display | Large LCD |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabSwift-aw |
| Measurement Range | 0.03–1.000 aw |
| Resolution | 0.01 aw |
| Accuracy | ±0.01 aw |
| Temperature Range | 5–45 °C |
| Temperature Accuracy | ±0.15 K |
| Weight | 1.2 kg |
| Data Storage | SD card |
| Calibration | Factory 6-point certified calibration |
| Sensor Type | CM-2 dual-electrolyte resistive sensor |
| Compliance | NIST-traceable, FDA-recommended, ISO 21807 compliant |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabTouch-aw |
| Measurement Range | 0.030–1.000 aw |
| Temperature Control Range | 15–30 °C |
| Accuracy | ±0.001 aw |
| Temperature Accuracy | ±0.1 °C |
| Display | Full-color TFT touchscreen |
| Probe Type | Patented Resistive Electrolyte Sensor (REMS) |
| Standard Reference | Long-life saturated salt solution standards |
| Host Weight | 1 kg |
| Compliance | NIST-traceable calibration, FDA-recognized methodology, ISO 21807, AOAC 975.34, USP <1112> |
| Brand | Novasina |
|---|---|
| Origin | Switzerland |
| Model | LabTouch-aw |
| Measurement Range | 0.030–1.000 aw |
| Operating Temperature | 5–45 °C |
| Temperature Control Range | 15–30 °C |
| Temperature Accuracy | ±0.15 K |
| Water Activity Resolution | 0.01 aw |
| Water Activity Accuracy | ±0.005 aw |
| Display | Large LCD touch screen |
| Data Storage | Internal memory for test data and methods |
| Connectivity | SD card, RS-232, USB |
| Dimensions (H×W×D) | 105 × 200 × 300 mm |
| Weight | 2.8 kg |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NPS-20 |
| Pricing | Upon Request |
| Brand | NORMALAB |
|---|---|
| Origin | France |
| Model | NTB Classic |
| Temperature Range | Ambient to 250 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Repeatability | ±0.02 °C |
| Temperature Display Resolution | 0.1 °C |
| Controller Precision | 0.01 °C |
| Test Positions | 6–9 |
| Compliance | ASTM D130, ASTM D4048, ISO 2160, IP 154, DIN 51759, NF M 07-015, GB/T 5096, SH/T 0023 |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | nuBeam |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | V1.2 |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–8000 mbar (max. 115 psi) |
| Bubble Point Accuracy | ±75 mbar |
| Diffusion Flow Accuracy | ±4% |
| Bubble Point Range | 590–6900 mbar |
| Diffusion Flow Range | 1–180 mL/min |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (L×W×H) | 400 × 240 × 270 mm (base) + 220 mm (height with display module) |
| Weight | 7.5 kg |
| Display | 3.2″ monochrome LCD |
| Data Storage | 20 test records |
| Language | Chinese only |
| Test Modes | Bubble Point (fully automated), Diffusion Flow (semi-automated), Hold Pressure (pressure decay) |
| Sample Compatibility | Symmetric & asymmetric membranes |
| Cleanroom Suitability | ISO Class B and above |
| Compliance | Designed to support execution of ASTM F838-22, USP <1207>, EP 2.6.27, and ISO 13408-2 integrity test protocols |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | 6.0 |
| Price | USD 11,800 (approx.) |
| Power Supply | 100–240 VAC, 50 Hz, 120 W |
| Operating Pressure Range | 100–10,000 mbar (14.5–145 psi) |
| Environmental Operating Conditions | 5–40 °C, 10–80% RH |
| Dimensions (mm) | 400 D × 240 W × 270 H₁ × 220 H₂ |
| Weight | 8 kg |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Water Intrusion Accuracy | ±0.01 mL |
| Net Volume Test Accuracy | ±4% |
| Bubble Point Range | 100–8,000 mbar |
| Diffusion Flow Range | 1–600 mL/min |
| Water Intrusion Range | 0.01–100 mL/min |
| Pre-stored Protocols | 80 |
| Audit Trail Events | 16+ logged parameters (user, timestamp, method, pressure, flow, pass/fail status, etc.) |
| Data Storage Capacity | >5,000 test records (unlimited with USB backup) |
| Display | 7" high-resolution color touchscreen |
| Interface Options | RS232, USB, optional industrial bus (e.g., Modbus TCP, Profibus DP) and analog I/O |
| Language Support | English & Chinese |
| Compliance | Fully aligned with USP <1207>, EP 2.6.27, ISO 13408-2, and FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | NYX |
|---|---|
| Model | CCT |
| Origin | Tianjin, China |
| Manufacturer | NYX (OEM/ODM Capable) |
| Compliance | GB/T 38304–2019, EN 511:2006, ISO 5085-1:1977 |
| Test Principle | Two-Plate Heat Flow Method (Steady-State Thermal Resistance Measurement) |
| Sample Diameter | ≈85 mm |
| Test Duration | ≤2 hours per specimen |
| Repeatability | <5% RSD (typical <1% between replicate runs) |
| Data Output | XML-formatted log files compliant with ISO/IEC 17025 traceability requirements |
| System Components | Precision aluminum test plates (hot/cold), climate-controlled chamber (±0.2°C stability), calibrated heat flux sensor array, real-time DAQ module, proprietary thermal resistance analysis software |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DKS-2 |
| Price Range | USD 1,400 – 4,200 |
| Test Chamber Volume | ~15 L (Ø250 mm × 340 mm) |
| Reaction Cylinder | Ø165 mm × 225 mm (H) |
| Impeller Diameter | 140 mm (Stainless Steel) |
| Impeller Speed | ~270 rpm |
| Sample Holders | Stainless Steel Clip Set (12 pieces) |
| Dimensions (L×W×H) | 46 × 46 × 77 cm |
| Power Supply | AC 220 V, 50 Hz, 25 W |
| Environmental Requirements | 20 ± 2 °C, 65 ± 2 % RH |
| Compliance Standards | JIS L 0855, ISO 105-G01, GB/T 11039.1–2005 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DT 200 |
| Pricing | Available Upon Request |
| Construction Material | ASTM A240 316L Stainless Steel |
| Chamber Internal Diameter | 100 mm |
| Chamber Internal Height | 20 ± 1 mm |
| Base Plate Central Opening | 50 mm |
| Optional Sample Cutting Die | 120 ± 1 mm |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GB/T 18426 |
| Price Range | USD 420 – 535 |
| Brand | NYX |
|---|---|
| Model | HG/T 2871 Compression Block |
| Material | Silicone Rubber (Shore A Hardness >75) |
| Dimensions | Three Sizes — Ø80 mm (for shoe length >240 mm), Ø70 mm (200–240 mm), Ø60 mm ( <200 mm) |
| Compliance | Conforms to HG/T 2871–2022 Clause 5.3.4 and Figure 1 / Table 1 |
| Manufacturing | Molded-in-one-piece, odorless, domestically produced in Tianjin, China |
| Package | 12 pieces per set (4 of each size) |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HY-760BX |
| Pricing | Upon Request |
| Control System | PLC-based Touchscreen Interface |
| Test Stations | 12 independent channels |
| Max. Sample Capacity | 12 specimens (standard configuration) |
| Specimen Type | Dumbbell-shaped or square cross-section rubber/plastic strips |
| Clamping Method | Four-sided mechanical clamping |
| Stroke Adjustment Range | 0–100 mm (continuously adjustable) |
| Test Speed | 60–300 rpm ±10 rpm |
| Drive Mechanism | Motor-driven eccentric cam + precision linkage system with linear guide columns |
| Failure Detection | Real-time individual channel break detection with autonomous counter halt |
| Safety Features | Interlocked transparent safety guard enclosure |
| Compliance Standards | GB/T 1688–2021, ISO 6943:1985, ASTM D430–18, DIN 53509-1:2006 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HY-767C |
| Price Range | USD 4,200 – 7,000 |
| Rotational Speed | 20–60 rpm |
| Sample Holder Span Adjustment | 200–400 mm |
| Drum Inner Diameter | 190 ± 2 mm |
| Drum Material | High-resilience synthetic rubber (dimensionally stable) |
| Max Timer Duration (Forward/Reverse) | 17 h 59 min each |
| Control Interface | Touchscreen with programmable cycle logic |
| Rotation Reversal | Automatic directional switch at preset intervals |
| Safety Features | Interlocked transparent safety door, circuit breaker, emergency stop |
| Motor Type | Brushless DC motor with load-independent speed stability |
| Pause Function | Real-time operational suspension via front-panel button |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HY-8760 |
| Pricing | Available Upon Request |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NC-703-2 |
| Price Range | USD 1,400 – 21,000 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PRLT |
| Measurement Range | 100 mm |
| Resolution | 0.02 mm |
| Compliance | GB/T 20991–2009, EN ISO 20344:2011 Section 5.3 |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | PST |
| Price Range | USD 1,400 – 4,200 |
| Sample Size | 102 × 204 mm (4 × 8 in) |
| Test Platform | 102 × 102 mm (4 × 4 in) |
| Central Aperture Diameter | 38.1 mm (1.5 in) |
| Loading Plunger Diameter | 25.4 mm (1 in) |
| Stroke | 57 mm (2.25 in) |
| Load Cell Options | 200 N (20 kgf) or 500 N (50 kgf), digital, unit-switchable (N/kgf/lbf) |
| Loading Mechanism | Pneumatic actuation |
| Loading Time | 1.7 ± 0.3 s over full stroke |
| Optional PC Software | Real-time force vs. displacement curve with peak force capture |
| Brand | NYX |
|---|---|
| Origin | Tianjin, China |
| Manufacturer | NYX Instrument Co., Ltd. |
| Model | TPP-Ⅱ |
| Compliance Standards | GB 8965.1-2009, GA 434, ISO 17492, ASTM F2700, ASTM F2703, NFPA 1971, NFPA 2112 |
| Heat Flux | 83 kW/m² ± 2 kW/m² |
| Meker Burner Output | 800–1200 BTU/min |
| Radiant Source | 9 × T150 quartz infrared tubes |
| Calorimeter | Copper disk with three embedded thermocouples (1.2 mm diameter, 0.13 mm depth) |
| Radiation Sensor | SB-type water-cooled sensor (0–100 kW/m²), NIST-traceable calibration certificate included |
| Gas Flow Control | Mass flow meter (±2% accuracy, >3 L/min range) |
| Automation | Pneumatic shield actuation and auto-specimen loading |
| Software | Integrated thermal injury prediction module (1st- and 2nd-degree burn curves), user-calibratable heat flux and thermocouple validation tools |
| Power Supply | 220 V AC, 50 Hz |
| Brand | NYX |
|---|---|
| Model | WFT |
| Standard Compliance | GB/T 34844–2017, GB/T 16797–2017 |
| Applied Force | 9.8 N |
| Stroke Length | 20 mm |
| Reciprocating Frequency | 160 cycles/min |
| Rotational Speed of Abrading Head | (10 ± 1) °/s |
| Effective Abrading Diameter | 39 mm |
| Overall Abrading Head Outer Diameter | 65 mm |
| Specimen Size | 135 mm × 90 mm |
| Total Mass of Abrading Head + Circular Plate | 366 g ± 0.5 g |
| Dimensions (L×W×H) | 50 × 40 × 35 cm |
| Net Weight | 25 kg |
| Brand | NYX |
|---|---|
| Model | WVH |
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Price | USD 720 (FOB Tianjin) |
| Test Principle | Gravimetric Measurement via Mass Change After 8-Hour Exposure to Saturated Water Vapor |
| Compliance Standards | GB/T 20991, EN ISO 20344:2011 Section 6.7, ISO 17699:2005 Section 4.2, GB/T 12624–2009 Section 6.5, EN 420:2003 & EN 420:2009, QB/T 4024–2010 Annex A |
| Sample Holders | 8-position, 6-position or 3-position test rack |
| Test Cup Inner Diameters | Φ35 mm (footwear), Φ56 mm (gloves), Φ43 mm & Φ85 mm (optional) |
| Test Duration | Fixed 8-hour exposure cycle |
| Measurement Resolution | 0.1 mg (requires external analytical balance, not included) |
| Brand | OASIS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LZ-7000 |
| Detection Method | Combined Spectrophotometric and Dry-Chemistry Assay |
| Measurement Range | 0–100% inhibition |
| Number of Channels | 36 |
| Measurement Error | ≤5% |
| Limit of Detection (LOD) | 0.01 mg/kg |
| Display | Color capacitive touchscreen |
| Storage | MicroSD (TF) card expandable |
| Connectivity | Wi-Fi, Bluetooth, Ethernet |
| Interfaces | USB 2.0, RJ45 Ethernet, HDMI |
| Power Supply | DC 12 V (adapter included) |
| Battery | Built-in high-capacity rechargeable Li-ion battery |
| Processor | Multi-core 1.8 GHz ARM-based SoC |
| Data Output | Integrated thermal printer + external printer support |
| GPS | Built-in GNSS module for geotagging |
| Brand | Ocean Optics |
|---|---|
| Model | SpectrumTEQ-EQY-EL |
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Configuration Options | Integrated Enclosed Sphere (3.3″) or Probe-Station-Based (1.5″) |
| Measurement Capabilities | EQE, Luminance, CIE Chromaticity Coordinates, Dominant Wavelength, Radiant Flux, EQE vs. Current Density |
| Software Integration | TEQ Control Suite with Source Meter Synchronization |
| Compliance Support | ASTM E308, CIE 127, ISO/CIE 11664, GLP-relevant audit trail logging |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Manufacturer | Ocean Insight (formerly Ocean Optics) |
| Model | SpectrumTEQ-EQY-PL |
| Configuration | Benchtop, Glovebox-Compatible Modular PL Quantum Yield System |
| Calibration | NIST-traceable excitation source |
| Measurement Type | Absolute photoluminescence quantum yield (PLQY), CIE chromaticity coordinates, dominant wavelength, spectral radiance, radiant flux, luminous flux, PLQY vs. excitation power |
| Sample Environment | Inert-atmosphere glovebox compatible (O₂ < 1 ppm, H₂O < 0.1 ppm) |
| Optical Architecture | Integrating sphere-based, dual-detector (excitation + emission) with spectral deconvolution |
| Excitation Flexibility | Interchangeable bandpass filters (250–850 nm range) for laser or LED excitation sources |
| Stability | Mechanical rigidity optimized for repeatable sample positioning (±5 µm vertical repeatability via motorized Z-stage) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | SpectrumTEQ-PL, SpectrumTEQ-EL |
| Measurement Mode | AC |
| Spectrometer Options | QE Pro or QE65 Pro |
| Spectral Range | 350–1100 nm |
| Signal-to-Noise Ratio | 1000:1 |
| Optical Resolution (FWHM) | 2.5 nm |
| Dynamic Range | 85,000:1 (QE Pro, single acquisition) |
| 25,000 | 1 (QE65 Pro, single acquisition) |
| AD Conversion | 18-bit (QE Pro) |
| Integrating Sphere Diameter | 3.3″ (SpectrumTEQ-PL), 1.5″ or 3.3″ (SpectrumTEQ-EL) |
| Sphere Coating | Spectralon® |
| Excitation Source | Fiber-coupled high-power LEDs (365–880 nm), tunable intensity, typical FWHM = 14 nm @ 405 nm |
| Fiber Core Diameter | 1000 µm (interchangeable) |
| Calibration Light Source | HL-3P-INT-CAL (5 W electrical power, 50 lm output) |
| Software | Ocean QY (for PL), SpectrumTEQ-EL (for EL) |
| Sample Compatibility | Solid, liquid, powder |
| Compliance | Supports GLP/GMP-aligned data integrity workflows |
| Brand | OCS |
|---|---|
| Origin | Germany |
| Model | FSA-100 |
| Detection Resolution | down to 5 µm |
| Defect Classification Levels | 10 user-defined grades |
| Line Speed Independence | Yes (via roller-mounted encoder) |
| Imaging Sensor | High-speed line-scan camera |
| Light Source | Integrated uniform illumination module |
| Software Interface | Menu-driven, SAA-compliant GUI |
| Data Output | Real-time display, HDD storage, customizable PDF/printed reports (tabular & color bar chart formats) |
| User Access Control | Password-protected parameter profiles |
| Material Compatibility | Transparent (films, glass) and opaque (paper, aluminum foil, stainless steel, nonwovens) |