| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 810-00-1 |
| Pricing | Upon Request |
| Pressure Source | CO₂ |
| Sample Chamber Dimensions | 7.8 cm ID × 27.6 cm L |
| Sample Volume Capacity | 1000 mL |
| Screen Diameter | 50 mm |
| Overall Dimensions | 29 × 20 × 69 cm |
| Weight | 10.9 kg |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 175-60 / 175-60-6 |
| Price | Upon Request |
| Brand | atten2 |
|---|---|
| Origin | Spain |
| Model | OilCMS |
| Instrument Type | Online Lubricant Condition Monitor |
| Detection Parameters | Particle Contamination, Water Content (RH%), Oil Degradation State, Viscosity Estimation (up to 3000 cSt) |
| Compliance Standards | ISO 4406, SAE AS4059, NAS 1638 |
| Display | 10-inch capacitive touchscreen |
| Power | Integrated rechargeable lithium battery |
| Data Storage | Local database for up to 500 oil samples with trend aggregation |
| Flow Control | Built-in motorized pump with optional high-pressure adapter (compatible with real-time recirculation systems up to 350 bar) |
| Particle Analysis Method | Digital imaging with bubble suppression and morphological classification |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 500 |
| Price | Upon Request |
| Standards Compliance | ASTM D36, ASTM E28, EN 1427, IP 58, ISO 4625, DIN 52011, NF T 66-008, AASHTO T53, JIS K2207 |
| Temperature Range | 0–250 °C |
| Temperature Resolution | 0.06 °C |
| Temperature Accuracy | ±0.1 °C |
| Brand | Atten2 |
|---|---|
| Origin | Spain |
| Model | OilMoisture |
| Product Type | Online Instrument |
| Detection Parameter | Water Content |
| Compliance Standard | ASTM D6304 |
| Sensitivity | ppm-level |
| Power Supply | 24 V DC, <100 mA |
| Output Interface | Modbus RTU (RS-485) |
| Max Operating Pressure | 12 bar |
| Operating Temperature Range | 0–80 °C |
| Viscosity Compatibility | up to 680 cSt |
| Housing Material | Aluminum (stainless steel optional) |
| Optical Window | BK7 glass |
| Sealing Material | Fluoroelastomer (FKM) |
| Ingress Protection | IP65 |
| Certification | CE |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | OK-ATE-2 |
| Price | USD 2,700 (FOB Guangdong) |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | OK-BMS-1 |
| Price | USD 2,700 (est.) |
| Voltage Range | <1 mV |
| Voltage Measurement Accuracy | <1 mV |
| Max Output Power | ±40 W |
| Current Measurement Accuracy | ±2 µA |
| Max Output Current | ±5 A |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | OK-CFDX-1 |
| Price | USD 4,950 (FOB Guangdong) |
| Voltage Range | 0–1000 V (expandable) |
| Voltage Accuracy | ±0.05% FS |
| Voltage Resolution | 1 mV |
| Charge Current Range | 0–200 A (expandable) |
| Discharge Current Range | 0–300 A (expandable) |
| Current Accuracy | ±0.05% FS |
| Current Resolution | 10 mA |
| Internal Resistance Range | 0–200 mΩ |
| IR Accuracy | ±1% FS |
| IR Method | AC Impedance at 1 kHz |
| Capacity Range | 0–1000 Ah |
| Capacity Accuracy | ±0.1% FS |
| Operating Temperature | −20 °C to +60 °C (optional −40 °C to +85 °C) |
| Temperature Control Accuracy | ±1 °C |
| Sampling Rate | 10–1000 Hz (user-selectable) |
| Data Storage | ≥1 million records |
| Data Export Formats | CSV, Excel (.xlsx), PDF |
| Communication Interfaces | RS485, Ethernet, USB (CAN, Modbus, Profinet optional) |
| Channel Configurations | 1–64 independent channels (benchtop or cabinet-mounted) |
| Power Input | AC 380 V ±10%, 50 Hz or AC 220 V ±10%, 50 Hz |
| Enclosure Rating | IP30 (IP54 optional) |
| Compliance | GB/T 31485–2015, GB/T 31486–2015, IEC 62619 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OK-CFDX-2 |
| Voltage Range | 0–1000 V (expandable) |
| Current Range | Charge 0–200 A / Discharge 0–300 A (both expandable) |
| Voltage Accuracy | ±0.05% FS |
| Current Accuracy | ±0.05% FS |
| Voltage Resolution | 1 mV |
| Current Resolution | 10 mA |
| Internal Resistance Range | 0–200 mΩ |
| IR Accuracy | ±1% FS |
| IR Method | AC Impedance at 1 kHz |
| Capacity Range | 0–1000 Ah |
| Capacity Accuracy | ±0.1% FS |
| Test Modes | CC/CV/CP |
| Sampling Rate | 10–1000 Hz (adjustable) |
| Data Storage | ≥1,000,000 records |
| Output Formats | Excel, CSV, PDF |
| Communication Interfaces | RS485, Ethernet, USB (CAN/Modbus/Profinet optional) |
| Enclosure Options | Benchtop or Cabinet |
| Channel Configurations | 1–64 independent channels |
| Power Supply | AC 380 V ±10% / 220 V ±10%, 50 Hz |
| IP Rating | IP30 (IP54 optional) |
| Temperature Range | −20 °C to +60 °C (−40 °C to +85 °C optional) |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | OK-CFDX-3 |
| Voltage Range | 0–1000 V (expandable) |
| Voltage Accuracy | ±0.05% FS |
| Voltage Resolution | 1 mV |
| Charge Current Range | 0–200 A (expandable) |
| Discharge Current Range | 0–300 A (expandable) |
| Current Accuracy | ±0.05% FS |
| Current Resolution | 10 mA |
| Internal Resistance Range | 0–200 mΩ |
| IR Accuracy | ±1% FS |
| IR Method | AC Impedance at 1 kHz |
| Capacity Range | 0–1000 Ah |
| Capacity Accuracy | ±0.1% FS |
| Test Modes | CC/CV/CP |
| Sampling Rate | 10–1000 Hz (adjustable) |
| Data Storage | ≥1,000,000 records |
| Data Export | Excel, CSV, PDF |
| Communication Interfaces | RS485, Ethernet, USB (CAN/Modbus/PROFINET optional) |
| Enclosure Options | Benchtop or Cabinet |
| Channel Configurations | 2–64 independent channels |
| Power Supply | AC 380 V ±10% / 50 Hz or AC 220 V ±10% / 50 Hz |
| IP Rating | IP30 (IP54 optional) |
| Temperature Chamber Integration | -20 °C to +60 °C (optional -40 °C to +85 °C) |
| Temp Control Accuracy | ±1 °C |
| Compliance | GB/T 31485-2015, GB/T 31486-2015, IEC 62619 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OK-CFDX-5 |
| Price | USD 2,700 (approx.) |
| Voltage Range | 0–1000 V (expandable) |
| Voltage Accuracy | ±0.05% FS |
| Voltage Resolution | 1 mV |
| Charge Current Range | 0–200 A (expandable) |
| Discharge Current Range | 0–300 A (expandable) |
| Current Accuracy | ±0.05% FS |
| Current Resolution | 10 mA |
| Internal Resistance Range | 0–200 mΩ |
| IR Accuracy | ±1% FS |
| IR Method | AC Impedance at 1 kHz |
| Capacity Range | 0–1000 Ah |
| Capacity Accuracy | ±0.1% FS |
| Operating Temperature Range | −20 °C to +60 °C (optional −40 °C to +85 °C) |
| Temperature Control Accuracy | ±1 °C |
| Sampling Rate | 10–1000 Hz (adjustable) |
| Data Storage Capacity | ≥1 million records |
| Data Export Formats | Excel, CSV, PDF |
| Communication Interfaces | RS485, Ethernet, USB (optional CAN, Modbus, PROFINET) |
| Channel Configuration | 1–64 channels (benchtop or cabinet-mounted) |
| Power Supply | AC 380 V ±10%, 50 Hz or AC 220 V ±10%, 50 Hz |
| Enclosure Rating | IP30 (industrial indoor), optional IP54 |
| Compliance | GB/T 31485–2015, GB/T 31486–2015, IEC 62619 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | OK-ATE-1 |
| Price | USD 3,100 (FOB Guangdong) |
| Voltage Range | DC 0–1000 V (battery side), AC 220/380 V ±20% (grid side) |
| Accuracy | ±0.02% FS, Resolution: 1 mV |
| Current Range | DC charge/discharge 0–200 A, AC output 0–100 A |
| Accuracy | ±0.05% FS, Resolution: 10 mA |
| Power Rating | 0–200 kW |
| Accuracy | ±0.1% FS |
| Sampling Rate | 10–2000 Hz |
| Communication Interfaces | Standard CAN, RS485, Ethernet, USB |
| Compliance | GB/T 3048.1–2018, GB/T 20438–2017, GB/T 37408–2019, IEC 62116, IEC 61000 |
| Enclosure Rating | IP30 (standard), optional IP54 |
| EMC | GB/T 17626 series |
| Brand | Olfasense |
|---|---|
| Origin | Germany |
| Model | CSD30 |
| Type | Passive Continuous Sampling Device for Odor and Volatile Gas Collection |
| Sampling Duration | 30 min (default, adjustable) |
| Sampling Principle | Diffusion-driven passive collection into Tedlar® or FlexFoil® gas sampling bags |
| Compliance | Designed for EN 13725:2022-compliant odor sampling |
| Brand | Olfasense |
|---|---|
| Origin | Germany |
| Model | LiGaVa 4.0 |
| Type | Liquid-to-Gas Phase Vaporization System |
| Regulatory Designation | Import (EU-manufactured) |
| Distribution Channel | Authorized Distributor |
| Brand | Olfasense |
|---|---|
| Origin | Germany |
| Model | SET1, SET2, SET3 |
| Application | Human Olfactory Screening, Training & Threshold Calibration |
| Brand | Olfasense |
|---|---|
| Origin | Germany |
| Model | TO8 Evolution |
| Type | Dynamic Dilution Olfactometer |
| Application | Human Panel-Based Odor Assessment |
| Brand | OMICRON |
|---|---|
| Origin | Austria |
| Model | CMC 256plus |
| Input Voltage Range | 85–264 VAC, 45–65 Hz |
| Operating Temperature | 0–50 °C |
| Weight | 16.0 kg |
| Dimensions | 450 × 145 × 390 mm |
| Compliance | IEC 61000-4 (EMC), IEC 61010-1 (Safety), ISO 9001 |
| Output Accuracy Class | Up to 0.2 |
| Synchronization | GPS / IRIG-B (<1 µs typical timing error) |
| Communication Protocols | IEC 61850 (GOOSE, SV, MMS), IEEE C37.118-1/2 |
| Software Platform | OMICRON Control, Test Universe |
| Brand | OMNION |
|---|---|
| Origin | USA |
| Model | OSI-24 |
| Temperature Range | 40–220 °C |
| Sample Capacity | 24 positions |
| Compliance | AOCS Cd 12b-92, ISO 6886:2006, EN 14112, JOCS, GB/T 21121 |
| Temperature Accuracy | ±0.1 °C |
| Brand | Omnion |
|---|---|
| Origin | USA |
| Model | OSI-24 |
| Sample Capacity | 24 positions |
| Temperature Range | 40–200 °C |
| Measurement Principle | Oxygen Uptake by Conductometric Detection (OSI Method) |
| Compliance | ASTM D5768, ISO 6886, AOCS Cd 12b-92, EN 14112 |
| Data Output | Real-time oxygen consumption curves, automatic endpoint detection, ISO-compliant report generation |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OSI-6 |
| Price Range | USD 27,000 – 68,000 |
| Brand | Das-Nano |
|---|---|
| Origin | USA |
| Model | ONYX-1 |
| Instrument Type | Room-Temperature Hall Effect System |
| Current Source Range | 20 mA |
| Measurement Principle | Microwave Reflectometry-Based Carrier Profiling |
| Applicable Mobility Range | 100–3000 cm²/V·s |
| Sample Compatibility | Monolayer to multilayer graphene, graphene oxide, PEDOT:PSS, CNT dispersions, MoS₂, h-BN, ALD-ZnO, GaN-on-SiC epiwafers, spin-coated photoresists, powders, and inkjet-printed films |
| Brand | Open Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LUMiKON MAX |
| Trigger Mode | Steady-State |
| Camera Resolution | 61 MP |
| Pixel Size (with optional telecentric lens) | 3.6 µm/pixel |
| Uniformity | <5% |
| Sample Stage Compatibility | Si, Perovskite, Perovskite/Si Tandem (23 × 23 cm), Upgradable to Triple-Junction & III–V Devices |
| Illumination Range | 0.01–1.2 suns (AM1.5G equivalent) |
| Optional Features | Temperature-Controlled Stage, IBC-Compatible Stage, Lock-in Thermography (DLI-T), Point-Scan TRPL Spectroscopy, N₂ Enclosure with Real-Time Humidity/Temperature Monitoring |
| Software | Python-API Enabled, iVoc Imaging, Time-Normalized PL Analysis, iFF/iMPP/Pseudo-JV Extraction |
| Brand | Open Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LUMiKON MINI |
| Trigger Mode | Steady-State |
| Dimensions (W×H×D) | 32.5 × 37 × 20.8 cm |
| Imaging Sensor | 26 MP (upgradable to 61 MP) |
| Uniformity | >95% |
| Illumination Range | 0.01–1.2 suns (AM1.5G equivalent) |
| Core Output Metrics | Quantitative iVoc, iFF, iMPP, and PL intensity maps |
| Environmental Compatibility | Glovebox-integrated (O₂ < 0.1 ppm, H₂O < 0.1 ppm) |
| Calibration | Absolute radiometric PL calibration with NIST-traceable reference source |
| Brand | Open Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LUMiKON MINI |
| Trigger Mode | Steady-State |
| Dimensions (W×H×D) | 32.5 × 37 × 20.8 cm |
| Imaging Sensor | 26 MP monochrome scientific CMOS (upgradable to 61 MP) |
| Uniformity | >95% (±5% irradiance variation across FOV) |
| Illumination Range | 0.01–1.2 suns (AM1.5G-equivalent, calibrated broadband LED source) |
| Real-Time Outputs | Quantitative PL intensity, implied Voc (iVoc), implied Fill Factor (iFF), implied Maximum Power Point (iMPP) maps |
| Spectral Capability | Optional point-scanning mode for full PL spectra (bandgap & compositional mapping) |
| Environmental Integration | Glovebox-compatible (O₂ < 0.1 ppm, H₂O < 0.1 ppm), no sample transfer required |
| Brand | OPISIS |
|---|---|
| Origin | Sweden |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FB-120 |
| Price | Upon Request |
| Capacity | 6 samples per batch |
| Dimensions (W×H×D) | 655 × 325 × 475 mm |
| Weight | 25 kg |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % RH |
| Voltage | 190–240 VAC, 50–60 Hz |
| Max. Power Consumption | 2000 W |
| Fiber Method | Crude Fiber (CF) per Weende and AOAC/ISO-compliant protocols |
| Hydrolysis Compatibility | Samples with fat content 0.1–100 %, sample mass 0.5–3 g |
| Brand | Opsis |
|---|---|
| Origin | Sweden |
| Model | FB-300 |
| Sample Capacity | 27 per batch |
| Throughput | 108 CF / 135 NDF / 162 ADF samples per day |
| Sample Mass Range | 0.1–2.0 g |
| Measurement Range | 0–100% |
| Repeatability | ≤ 0.5% |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Accuracy | ±0.1 °C |
| Display | Color LCD touchscreen with bilingual (EN/CN) interface |
| Programmable Methods | Up to 50 user-defined protocols |
| Compliance | AOAC 978.10, AOAC 2002.04, AOAC 962.09, AACC 32–25, USP <281>, GB/T 6434–2006, GB/T 20806–2006, AAFCO Official Methods |
| Safety Systems | Dual liquid-level sensors, real-time temperature & pressure monitoring, mechanical pressure relief valve, lid interlock sensor |
| Software Integration | LabConnect LIMS-ready, optional balance & barcode scanner interface |
| Power Supply | 230 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 720 × 650 × 780 mm |
| Weight | 85 kg |
| Brand | Opsis |
|---|---|
| Origin | Sweden |
| Model | FB-310 |
| Sample Capacity | 27 per batch |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Repeatability | ≤0.5% RSD |
| Measurement Range | 0–100% |
| Display | Color LCD touchscreen with bilingual (English/Chinese) interface |
| Programmable Methods | Up to 50 user-defined protocols |
| Reagent Ports | 4 independent external connections (acid, base, neutral detergent, acid detergent) + dedicated amylase reservoir |
| Compliance | AOAC 978.10, AOAC 2002.04, AOAC 962.09, AACC 32–25, USP <281>, GB/T 6434–2006, GB/T 20806–2006, AAFCO Official Methods |
| Brand | OPTI |
|---|---|
| Origin | USA |
| Model | OPTI CCA |
| Measurement Principles | Fluorescence-based optical sensing (pO₂, pCO₂), Reflectance photometry (pH, tHb, SO₂), Ion-selective field-effect transistor (ISFET) for electrolytes (Na⁺, K⁺, Ca²⁺, Cl⁻), Enzymatic electrochemical detection (Glu) |
| Sample Volume | 95 µL whole blood (arterial, venous, capillary) |
| Test Time | ≤85 seconds |
| Calibration | Factory-calibrated disposable cartridges, no user calibration required |
| Data Storage | Internal memory for ≥10,000 patient results with timestamps, operator IDs, and QC records |
| Connectivity | USB, RS-232, optional HL7 v2.x over Ethernet |
| Regulatory Compliance | FDA 510(k) cleared, CE-IVD, ISO 13485 certified, CLIA-waived for certain test panels |
| Power | Rechargeable Li-ion battery (≥8 hours continuous operation), auto-switching AC/DC |
| Brand | Optimol |
|---|---|
| Origin | Germany |
| Model | 2Disk |
| Drive Speed Range | 1–3000 rpm |
| Applied Load Range | 10–5000 N |
| Maximum Test Duration | 999 h |
| Cooling | Optional Water-Cooled Drive Spindle |
| Temperature Monitoring | Integrated Spindle & Lubricant Temperature Sensors |
| Optional Measurements | Lubricant Film Thickness (Oil Gap), Electrical Resistance, Acoustic Emission (Noise), Wear Volume Quantification |
| Environmental Control Options | Heated Oil Bath, External Oil Circulation Pump |
| Software | Customizable LabVIEW- or Python-Based Control & Data Acquisition Suite |
| Brand | Optimol |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ETS |