| Brand | Shenkai |
|---|---|
| Origin | Shanghai, China |
| Model | SYP4302-II |
| Penetration Measurement Range | ≤620 dmm |
| Standard Needle Mass | 2.5 g ±0.05 g |
| Rod Mass | 47.5 g ±0.05 g |
| Standard Weight | 50 g ±0.05 g |
| Temperature Control Range (Water Bath) | 0.00–50.00 °C (with cooling up to 20 °C below ambient) |
| Temperature Stability | ≤±0.1 °C |
| Timing Range | 0–9 min 59 s |
| Timing Accuracy | ±0.1 s |
| Data Storage Capacity | 200 test records |
| Interface | USB port + thermal printer integrated |
| Sample Stage | Adjustable leveling mechanism |
| Illumination | Integrated focused LED lamp + magnifier |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | EZ Test |
| Price Range | USD 14,000 – 42,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | SMV-300/300RT |
| Mooney Viscosity Range | 0–200 M (extendable to 400 M) |
| Test Temperature Range | Ambient to 200 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Rotor Speed (SMV-300RT only) | 0.5–5 rpm |
| Rotor Type | L-shaped |
| Sample Dimensions | Ø ≈ 50 mm × Thickness ≈ 6 mm |
| Heating Method | Thin-film heater with optimized PID control |
| Compression Method | Pneumatic cylinder actuation |
| Viscosity Measurement Duration | 0–99 min 59 sec (up to 10 time points programmable) |
| Scorch Point Setting Range | 0–99.9 M (up to 10 points programmable) |
| Data Logging & Statistical Analysis | Built-in |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Product Type | Imported Instrument |
| Model | SNTR-8400AT |
| Instrument Category | Online Dissolution Tester |
| Number of Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 0–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Control Range | Ambient +5 °C to 60 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 17 L |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer | Shimadzu Corporation |
| Type | Imported |
| Model | SNTR-8600 |
| Instrument Type | Online Dissolution Tester |
| Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 0–250 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient +5 to 60 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 17 L |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Origin Category | Domestic (China) |
| Model | NJ-ZH-XP |
| Pricing | Available Upon Request |
| Brand | Shqigao |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-0923C-1 |
| Drum Diameter | 286 mm |
| Drum Depth | 39 mm |
| Tablet Drop Height | 156 mm |
| Rotation Count Range | 10–990 revolutions (default: 100) |
| Rotation Speed | 25 rpm ±1 rpm |
| Power Supply | 220 V / 50 Hz / 20 W |
| Dimensions (W×D×H) | 370 × 300 × 340 mm |
| Weight | 15 kg |
| Brand | SHqigao |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-7000 |
| Temperature Control Accuracy | 37 °C ± 0.3 °C |
| Temperature Set Range | 30–40 °C |
| Cylinder Dimensions | Ø52 mm × 60 mm (H) |
| Metal Rack Dimensions | Ø50 mm, Aperture Ø4 mm, Plate Spacing 30 mm |
| Inversion Angle | 180° |
| Disintegration Timings | P1 (30 min, inversion every 10 min), P2 (60 min, inversion every 10 min), P3 (30 min, no inversion) |
| Beaker Capacity | 5 L (3 units standard) |
| Heating Power | 1300 W |
| Power Supply | 220 V ± 10%, 50 Hz |
| Brand | SHqigao |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HSY-7000B |
| Price | Upon Request |
| Rack Units | 3 |
| Transparent Tube Dimensions | 60 mm height × 52 mm internal diameter |
| Stainless Steel Mesh Discs | 2 per rack, Ø50 mm, each with 9 × 4 mm apertures |
| Timing Range | 10–900 min |
| Timing Accuracy | ±0.5 min |
| Temperature Control Range | 20–45 °C |
| Temperature Stability | ±0.3 °C |
| Bath Vessel Capacity | 5 L × 3 |
| Power Supply | 220 V / 50 Hz / 1000 W |
| Brand | Shunso |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Region Category | Domestic (China) |
| Model | Shunso Z10 |
| Pricing | Upon Request |
| Origin | Switzerland |
|---|---|
| Type | Kinematic Viscosity Tester |
| Standards | ASTM D88, ASTM E102, FTM 791-0304, JIS K 2207 |
| Temperature Range (D88 mode) | 21–99 °C (70–210 °F) |
| Temperature Range (E102 mode) | 121–232 °C (250–450 °F) |
| Power Supply | 220 V AC, 50/60 Hz |
| Dimensions | 50 × 50 × 69 cm |
| Weight | 25 kg |
| Orifice Diameters | 1.76 mm (standard), 3.15 mm (furfural) |
| Sample Positions | 1, 2 or 3 (model-dependent) |
| Brand | SIELINS |
|---|---|
| Model | XLZ-1090 |
| Origin | Beijing, China |
| Gas Detection Principles | NDIR (CO, CO₂, CH₄), Electrochemical (O₂, H₂S), Thermal Conductivity (H₂) |
| Measurement Ranges | CO 0–40% vol, CO₂ 0–25% vol, CH₄ 0–10% vol, O₂ 0–25% vol, H₂ 0–25% vol, H₂S 0–1000 ppm |
| Resolution | 1 unit (per gas channel) |
| Zero Drift | ≤±1% FS / 7 days |
| Span Drift | ≤±1% FS / 7 days |
| Linearity Error | ≤±1% FS |
| Response Time (T90) | ≤15 s |
| Output Signals | 4–20 mA (isolated), RS485/RS232 (optional) |
| Power Supply | 220 ±22 VAC, 50 ±0.5 Hz |
| Power Consumption | 80 W |
| Operating Temperature | 0–45 °C |
| Weight | ~12 kg |
| Enclosure | Wall-mountable IP65-rated housing |
| Compliance | Designed for continuous emission monitoring in biogas upgrading, anaerobic digestion, and biomass gasification applications |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Eclipse |
| Pricing | Upon Request |
| Brand | Sievers (Veolia) |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Import Status | Imported |
| Model | Sievers Eclipse |
| Pricing | Available Upon Request |
| Brand | SIGAS (Schütz Mess- und Regeltechnik) |
|---|---|
| Origin | Germany |
| Model | AGS 35-50 |
| Supply Configuration | Dual-bank cylinder auto-switching with priority liquid oxygen inlet (AGS 80P compatible) |
| Pressure Monitoring | Continuous real-time differential pressure sensing |
| Control Logic | Automatic switchover triggered by user-defined high/low pressure thresholds |
| Compliance | Designed to meet ISO 8573-1 (compressed air quality), EN ISO 7396-1 (medical gas pipeline systems), and IEC 60601-1 (medical electrical equipment safety) |
| Brand | SIGAS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CMGS-2000 Series |
| Pricing | Available Upon Request |
| Brand | SIGAS |
|---|---|
| Origin | Germany |
| Product Type | Medical humidification and suction system |
| Model | SIGAS Humidification & Suction Device |
| Compliance | CE-marked per MDR 2017/745 |
| Vacuum Range | 0–80 kPa (0–0.8 bar) |
| Operating Pressure | 400–600 kPa compressed air supply |
| Humidification Principle | Bubble-through immersion tube with multi-orifice diffusion |
| Brand | SIGAS |
|---|---|
| Origin | Germany |
| Model | SIGAS-MAD Series |
| Type | Twin-Tower Desiccant Air Dryer |
| Inlet Pressure Range | 6–10 bar(g) |
| Dew Point | ≤ −40 °C (at pressure) |
| Flow Capacity | 10–2000 Nm³/h |
| Filtration Stages | Pre-filter (ISO 8573-1 Class 2, 2, 2), Coalescing + Activated Carbon Post-filter (Class 1, 1, 1) |
| Regeneration Method | Purge-air (heatless) or Blower-assisted (optional) |
| Compliance | ISO 8573-1:2010, ISO 7396-1:2016, EN 13544-1:2021, DIN SPEC 5000-2, VDI 2083 Part 10 |
| Brand | SIGAS (Schütz Measuring & Control) |
|---|---|
| Origin | Germany |
| Model | PR-Station |
| Inlet Pressure Range | 0.1–1.6 MPa |
| Outlet Pressure Range | 0.1–0.8 MPa (adjustable per circuit) |
| Construction | De-greased Oxygen-Service Copper Tubing (Φ15×1 mm or Φ22×1.2 mm standard |
| Configuration | Dual independent pressure-regulated circuits with isolation valves, digital pressure gauges (0–1.6 MPa), optional explosion-proof enclosure, optional safety valves, optional emergency door release mechanism, optional medical-grade audible/visual alarm with remote telemetry module |
| Brand | Eurotech |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D25–D35 |
| Price Range | USD 14,000 – 42,000 (FOB Italy) |
| Brand | EUROTECH |
|---|---|
| Origin | Italy |
| Model | XTR Series (with Vacuum Pump & Air-Cooled Strand Pelletizer) |
| Screw Diameter Options | 20 / 25 / 30 / 35 mm |
| Gearbox Design | Rear-Removable for Rapid Screw Extraction |
| Barrel | Bimetallic Construction |
| Screw | Special Surface-Coated Hardened Steel |
| Venting Configuration | Atmospheric or Vacuum-Connected (XTR-D Variant) |
| Application Focus | Polymer Processing, Recycled Material Compounding, Mineral-Filled Compound Extrusion |
| Brand | SITA |
|---|---|
| Model | CleanoSpector |
| Origin | Tianjin, China |
| Manufacturer | LEI-TECH Optics |
| Type | Handheld Fluorescence-Based Surface Contamination Analyzer |
| Measurement Principle | UV-Induced Fluorescence (365 nm excitation, 460 nm emission peak) |
| Units | RLU (Relative Light Units) and % Cleanliness |
| Range | 0.0 – 100.0 RLU |
| Sensitivity | <1 µg/m² non-volatile residue (e.g., oils, coolants, waxes) |
| Response Time | ~1 s per measurement |
| Probe Geometry | Fixed-focus coaxial optical head with 4.7 mm optimal working distance |
| Calibration | Auto-calibration on clean reference metal surface (steel, aluminum, copper, gold, etc.) |
| Power | Rechargeable Li-ion battery (8 h continuous operation) |
| Weight | 320 g (including probe and handle) |
| Data Storage | Internal memory for >5,000 timestamped measurements |
| Compliance | Designed for ISO 16232-C, VDA 19.1, ASTM D7215, and automotive OEM cleaning validation workflows |
| Brand | Skalar |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | SP2000 Beer |
| Instrument Category | Beer-Specific Analyzer |
| Application Environment | Laboratory |
| Cycle Time per Sample | 8 min |
| Alcohol Content Detection | Not Applicable |
| pH Range | –2.0 to +16.0 |
| Dimensions (L × W × H) | 75 × 70 × 121 cm |
| Weight | 90 kg |
| Brand | SKF |
|---|---|
| Origin | Austria |
| Model | SKF EMCOR |
| Standard Compliance | ASTM D6138, ISO 11007 (equivalent to SH/T 0700), DIN 51802 |
| Rotational Speed | 80 rpm |
| Test Positions | 8 |
| Test Bearing | SKF 1306K / 236725 |
| Test Duration | 8 h per cycle × 3 cycles |
| Rust Evaluation | Visual inspection and quantitative assessment of outer raceway corrosion using calibrated dial gauge |
| Optional Accessory | Wash-out spray unit |
| Mounting | Precision-engineered test bench with standardized grease application fixture |
| Origin | Austria |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROF+ |
| Pricing | Available Upon Request |
| Brand | SKF |
|---|---|
| Origin | Austria |
| Model | SKF ROF+ |
| Testing Speed Range | 5000–25,000 rpm |
| Operating Temperature Range | Ambient to 230 °C |
| Radial Load Range | 50–900 N |
| Axial Load Range | 100–1100 N |
| Test Stations | 5 |
| Compatible Bearings | ISO 6202, 6203, 6204, 608 |
| Compliance | ASTM D3336 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SKMBT |
| Pricing | Available Upon Request |
| Brand | Shenko |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2001-VIII |
| Distillation Method | SH/T 0165 |
| Temperature Range (Distillation) | 0–400 °C (vacuum) |
| Temp. Accuracy | ±0.1 °C |
| Receiving Bath Temp. Range | 0–80 °C |
| Temp. Stability | ±0.2 °C |
| Vacuum Control Range | 2–50 mmHg |
| Vacuum Stability | ±0.2 mmHg |
| Volume Measurement Accuracy | ±0.1 mL |
| Data Storage Capacity | ≥5000 test records |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Dimensions (W×D×H) | 780 × 395 × 590 mm |
| Net Weight | 63 kg |
| Brand | Shengkai |
|---|---|
| Origin | Shanghai, China |
| Model | SKY7200-II |
| Detection Method | High-Temperature Combustion UV Fluorescence |
| Detection Range | 0.5–10,000 mg/kg |
| LOD | 0.5 mg/kg |
| Repeatability | ≤ ±0.2 mg/kg (0.5–1.0 mg/kg), ≤ 10% RSD (1.0–10 mg/kg), ≤ 5% RSD (≥10 mg/kg) |
| Sample Type | Liquid (standard) |
| Sample Volume | 5–50 µL |
| Furnace Temp | RT–1075 °C ±25 °C |
| Gas Control | Mass Flow Controllers (Ar: 50–300 mL/min |
| O₂ | 250–500 mL/min |
| Pressure | 0.2 MPa) |
| Analysis Time | 1–3 min |
| Display | 17″ Color Touchscreen IPC |
| Data Storage | >5,000 test records |
| Power | ≥3 kW, AC220V±5%, 50 Hz |
| Dimensions | 595×510×410 mm (W×D×H) |
| Net Weight | 30 kg |
| Compliance | ASTM D5453, SH/T 0689, GB/T 34100 |
| Origin | United Kingdom |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Handheld Spectral Radiometer |
| Pricing | Available Upon Request |