- All
- Favorite
- Popular
- Most rated
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Intepure-F 300 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC System |
| Flow Rate Range | 1–300 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ±1% |
| Maximum Operating Pressure | 500 psi |
| Wavelength Range | 200–400 nm or 200–800 nm |
| Wavelength Repeatability | ±0.5 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU (254 nm, Time Constant 0.75 s) |
| Data Acquisition Rate | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | NS4205 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–49.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Pressure | 25 MPa |
| Wavelength Range | 190–800 nm (±2 nm accuracy) |
| Wavelength Reproducibility | ±0.2 nm |
| Baseline Noise | ≤2×10⁻⁵ AU (254 nm, 1 s time constant) |
| Data Acquisition Rate | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NS9002S |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0–99.99 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 15 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 50 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Producer |
| Product Category | Domestic |
| Model | NS43300 |
| Application Level | Industrial Preparative |
| Instrument Type | High-Pressure Preparative HPLC |
| Flow Rate Range | 0.1–2999.9 mL/min |
| Flow Accuracy | RSD ≤ 1% |
| Flow Precision (Repeatability) | ≤ 1% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NS43100 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–599.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Operating Pressure | 15 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Reproducibility | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | NP7005-10C |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography System |
| Flow Accuracy | ±0.5% over full range (0.01–100 mL/min) |
| Flow Pulsation | <0.1% RMS (measured at 1 mL/min, 10 MPa) |
| Maximum Operating Pressure | 10 MPa |
| Display | 4.7-inch TFT LCD (320 × 240 pixels) |
| User Programs | 10 stored gradient methods |
| Communication Interface | Open ASCII-based RS-232/RS-485 protocol compliant with ASTM E1381 and IEEE 11073 standards |
| Column Cleaning Mode | Optional automated back-flush for piston and seal assembly |
| Seal Lifetime Extension | Enabled via programmable solvent rinse during idle and gradient hold phases |
| Brand | Hanbon |
|---|---|
| Model | NP-7000 Series |
| Type | High-Pressure Preparative Liquid Chromatography Pump |
| Flow Range (NP7030C) | 0.01–300.00 mL/min, Increment: 0.01 mL/min |
| Flow Range (NP7060C) | 0.01–600.00 mL/min, Increment: 0.01 mL/min |
| Flow Range (NP7100C) | 0.1–1000.0 mL/min, Increment: 0.1 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤0.5% |
| Pressure Pulsation | ≤0.5 MPa |
| Max Pressure (NP7030C) | 15 MPa |
| Max Pressure (NP7060C/NP7100C) | 10 MPa |
| Tubing Connection | 1/8″ Standard Fitting |
| Display | 320×240 LCD |
| Control Interface | Front-panel keypad + RS232/USB computer remote control |
| Power Input | 85–264 VAC |
| Power Consumption (NP7030C/NP7060C) | 500 W |
| Power Consumption (NP7100C) | 750 W |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NS4330 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.1–3000.0 mL/min |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 15 MPa |
| Wavelength Range | 0.5 nm |
| Wavelength Reproducibility | 0.1 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NS4360 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatography System |
| Flow Rate Range | 0.01–599.99 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision (RSD) | ≤1% |
| Maximum Pressure | 15 MPa |
| Wavelength Range | ±2 nm |
| Wavelength Repeatability | 0.2 nm |
| Baseline Noise | 2 × 10⁻⁵ AU (254 nm, TC = 1 s) |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Models | 200, 300, 450, 500, 600, 800, 1000 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 10 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU (at 254 nm) |
| Data Acquisition Frequency | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | NS9001S |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0–99.99 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 1 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | 0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 50 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | NS4210 |
| Price Range | USD 14,000 – 28,000 |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.01–100 mL/min |
| Flow Accuracy | ±0.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Pressure Rating | 20 MPa |
| Wavelength Range | 190–700 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU |
| Data Acquisition Frequency | 5 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CS-Prep 1600 |
| Application Level | Industrial Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 7 MPa |
| Wavelength Range | 190–800 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU @ 254 nm |
| Data Acquisition Frequency | 20 Hz |
| Regulatory Compliance | Designed and validated per GAMP5 |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Cs-Prep 1100, Cs-Prep 1200 |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | High-Pressure Preparative Liquid Chromatograph |
| Flow Rate Range | 0–300 L/h |
| Flow Accuracy | ±1.5% |
| Flow Precision (RSD) | ≤0.1% |
| Maximum Operating Pressure | 7 MPa |
| Wavelength Range | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Baseline Noise | ±0.5 × 10⁻⁵ AU at 254 nm |
| Data Acquisition Frequency | 20 Hz |
| Brand | Hanbon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Intepure-F 200 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative HPLC System |
| Flow Rate Range | 1–200 mL/min |
| Flow Accuracy | ±2% |
| Flow Precision (RSD) | ±2% |
| Maximum Operating Pressure | 200 psi |
| Wavelength Range | 200–400 nm or 200–800 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Baseline Noise | ±5 × 10⁻⁵ AU (254 nm, Time Constant 0.75 s) |
| Data Acquisition Rate | 20 Hz |