| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY02S |
| Instrument Type | Darkroom-Free Enclosed Transilluminator |
| Wavelengths | 254 nm (reflective), 302 nm (transmissive), 365 nm (reflective) |
| UV Filter Glass Dimensions | 200 × 150 mm |
| UV Lamp Power | 8 W (302 nm transmissive), 11 W (254 nm reflective), 11 W (365 nm reflective) |
| Overall Dimensions (L×W×H) | 435 × 295 × 490 mm |
| Net Weight | 16.9 kg |
| Lamp Type | Quartz UV Lamps |
| Viewing Chamber | Integrated dark-box design with ergonomic gel-cutting access port |
| Camera Mount | Adjustable vertical camera lift assembly (camera not included) |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JY04S-3C |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 1.4 MP (1280 × 1024) |
| Bit Depth | 10-bit |
| Dynamic Range | 0–4.8 OD |
| CCD Sensor Size | 2/3" |
| Detection Sensitivity | <20 pg double-stranded DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | F/1.2, 8–48 mm 6× zoom lens |
| UV Transillumination Area (W×L) | 250 × 200 mm |
| Visible Light Transillumination Area (W×L) | 250 × 210 mm |
| UV Transillumination Wavelength | 302 nm (8 W) |
| UV Reflectance Wavelengths | 254 nm & 365 nm (11 W each) |
| Dimensions (L×W×H) | 470 × 405 × 820 mm |
| Net Weight | 29.0 kg |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JY04S-3D |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 3.0 Megapixels |
| Bit Depth | 10-bit |
| CCD Sensor Size | 2/3-inch |
| Detection Sensitivity | <20 pg double-stranded DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens | 8–48 mm focal length, 6× zoom, f/1.2 aperture |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY04S-3E |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5 MP (2560 × 1920) |
| Bit Depth | 10-bit |
| CCD Sensor Size | 2/3" |
| Lens | F/1.2, 6× Motorized Zoom |
| UV Transillumination Wavelength | 302 nm |
| Reflective UV Wavelengths | 254 nm & 365 nm |
| Visible Light Transillumination Area | 250 × 210 mm |
| UV Transillumination Area | 250 × 200 mm |
| UV Lamp Power | 302 nm (8 W), 254/365 nm (11 W each) |
| Optical Filter | 590 nm Bandpass |
| Sensitivity | Detects <20 pg dsDNA stained with ethidium bromide |
| SNR | ≥56 dB |
| Dimensions (L×W×H) | 470 × 405 × 820 mm |
| Net Weight | 29.0 kg |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY1000E |
| Instrument Type | Nucleic Acid Electrophoresis Power Supply |
| Output Modes | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Voltage Range | 30–1000 V |
| Current Range | 1–500 mA |
| Power Range | 1–300 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (increment: 1 V·h) |
| Display | Backlit LCD |
| Output Terminals | 4 independent pairs |
| Dimensions (L×W×H) | 263 × 275 × 125 mm |
| Net Weight | 4.6 kg |
| Safety Protections | Overload, No-Load, Leakage Current, Short-Circuit |
| Memory Capacity | 100 pre-programmed methods |
| Stepwise Programming | Up to 10 sequential steps, each with independent voltage/current/power/timer settings |
| Pause & Real-Time Adjustment | Supported without compromising output stability or control accuracy |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY1600E |
| Output Type | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Output Range | 10–1600 V, 1–200 mA, 1–320 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (increment: 1 V·h) |
| Display | Backlit LCD |
| Output Ports | 4 pairs |
| Dimensions (L×W×H) | 263 × 275 × 125 mm |
| Net Weight | 4.4 kg |
| Safety Protections | Overload, Open-Circuit, Leakage Current, Thermal Shutdown |
| Control Architecture | Dual-core microprocessor with touch-sensitive keypad |
| Method Storage | 100 user-programmable electrophoresis protocols |
| Operational Modes | Standard, Timed, Volt-Hour, Stepwise (up to 10 sequential programs, each supporting up to 10 steps) |
| Pause & Real-Time Adjustment | Supported with full output stability retention |
| Auto Memory & Auto Shut-off | Enabled |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY200C |
| Instrument Type | Protein Electrophoresis Power Supply |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–200 V |
| Current Range | 1–2000 mA |
| Power Range | 1–200 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128 × 64 pixels) |
| Output Ports | 4 pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Safety Protections | Overload, No-Load, Leakage Detection |
| Memory Capacity | 10 Predefined Methods |
| Optional Functions | Power-Fail Recovery, Anti-Diffusion Electric Field Module |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY200E |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–200 V (1 V resolution) |
| Current Range | 1–2000 mA (1 mA resolution) |
| Power Range | 1–200 W (1 W resolution) |
| Timing Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (1 V·h increment) |
| Display | Backlit LCD |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Protection Features | Overload, Open-Circuit, Leakage Detection |
| Memory Capacity | 100 pre-programmed methods |
| Control Architecture | Dual-core microprocessor with touch-sensitive keypad |
| Operational Modes | Standard, Timed, Volt-Hour, Stepwise (up to 10 sequential programs, each with up to 10 steps) |
| Pause & Real-time Adjustment | Supported with maintained output stability |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY300 |
| Output Modes | Constant Voltage or Constant Current (continuously adjustable) |
| Voltage Range | 5–300 V |
| Current Range | 1–300 mA |
| Max Power | 90 W |
| Resolution | 1 V / 1 mA |
| Timer Range | 1 min – 9 h 59 min |
| Display | Dual LED digital display |
| Output Ports | 2 pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.0 kg |
| Safety Protections | Overload, no-load, and leakage current protection |
| Control System | Microprocessor-based intelligent control with touch keypad and molded chassis |
| Brand | Junyi |
|---|---|
| Model | JY3000E |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 20–3000 V (1 V resolution) |
| Current Range | 1–400 mA (1 mA resolution) |
| Power Range | 1–400 W (1 W resolution) |
| Timer Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (1 V·h increment) |
| Display | Backlit LCD |
| Output Ports | 4 independent channels |
| Dimensions (L×W×H) | 263 × 275 × 125 mm |
| Net Weight | 4.8 kg |
| Protection Features | Overload, No-Load, Leakage Detection, Short-Circuit, Thermal Shutdown |
| Memory Capacity | 100 pre-programmed methods |
| Stepwise Programming | Up to 10 sequential programs, each with up to 10 steps |
| Pause & Real-Time Adjustment | Supported with precision retention |
| Compliance | Designed for GLP-compliant electrophoresis workflows |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY300C |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 3–300 V (1 V resolution) |
| Current Range | 1–400 mA (1 mA resolution) |
| Power Range | 1–120 W (1 W resolution) |
| Timing Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128×64 pixels) |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 280×237×118 mm |
| Net Weight | 3.2 kg |
| Safety Protections | Overload, open-circuit, leakage current, thermal shutdown |
| Memory Capacity | 10 pre-programmed methods |
| Compliance | CE-marked design principles |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY300E |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–300 V (1 V resolution) |
| Current Range | 1–400 mA (1 mA resolution) |
| Power Range | 1–120 W (1 W resolution) |
| Timer Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (1 V·h increment) |
| Display | Backlit LCD |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Safety Protections | Overload, Open-Circuit, Leakage Current Detection |
| Memory Capacity | 100 user-defined methods |
| Step Programming | Up to 10 sequential programs, each with up to 10 steps |
| Pause & Real-Time Adjustment | Supported with precision retention |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY300HC |
| Instrument Type | Protein Electrophoresis Power Supply |
| Output Modes | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Voltage Range | 10–300 V |
| Current Range | 1–1500 mA |
| Power Range | 1–450 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128×64 pixels) |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Protection Features | Overload, No-Load, Leakage Current Protection |
| Optional Functions | Power-Fail Resume, Anti-Diffusion Electric Field Control |
| Compliance | CE-marked design principles |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY300HE |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 10–300 V (1 V resolution) |
| Current Range | 1–1500 mA (1 mA resolution) |
| Power Range | 1–450 W (1 W resolution) |
| Timer Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (1 V·h increment) |
| Display | Backlit LCD |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Protection Features | Overload, No-Load, Leakage Detection, Short-Circuit, Thermal Shutdown |
| Memory Capacity | 100 pre-programmed methods |
| Control Architecture | Dual-core microprocessor with real-time feedback loop |
| Operating Modes | Standard, Timed, Volt-Hour, Stepwise (up to 10 sequential programs, each with up to 10 steps) |
| Pause & Fine-Tune Functionality | Real-time parameter adjustment during pause without drift or stability loss |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY5000E |
| Output Type | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Output Range | 20–5000 V, 1–200 mA, 1–100 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timing Range | 1 min – 99 hr 59 min |
| Volt-Hour Range | 1–99999 V·hr (increment: 1 V·hr) |
| Display | Backlit LCD screen |
| Output Ports | 2 pairs |
| Dimensions (L×W×H) | 368 × 255 × 133 mm |
| Net Weight | 10.6 kg |
| Safety Protections | Overload, open-circuit, leakage current, thermal overload |
| Control Architecture | Dual-core microprocessor with touch-key interface |
| Method Storage | 100 user-programmable electrophoresis protocols |
| Advanced Functions | Stepwise program execution (up to 10 sequential steps, 10 sub-programs per step), real-time pause & fine-tuning, gel temperature monitoring (optional external sensor), auto-memory and auto-shutdown |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600 |
| Instrument Type | Protein Electrophoresis Power Supply |
| Output Modes | Constant Voltage or Constant Current |
| Voltage Range | 5–600 V (1 V resolution) |
| Current Range | 1–200 mA (1 mA resolution) |
| Maximum Power | 120 W |
| Timer Range | 1 min – 9 h 59 min |
| Display | Dual LED digital display |
| Output Ports | 2 pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.0 kg |
| Safety Protections | Overload, open-circuit (no-load), and leakage current protection |
| Control Logic | Microprocessor-based intelligent control with auto-memory and auto-shutdown functions |
| Operating Modes | Voltage- or current-prioritized output with real-time mode indication |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600C |
| Instrument Type | Protein Electrophoresis Power Supply |
| Output Modes | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Voltage Range | 10–600 V |
| Current Range | 1–500 mA |
| Power Range | 1–300 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128 × 64 pixels) |
| Output Ports | 4 pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Safety Protections | Overload, No-load, Leakage current |
| Memory | Stores up to 10 user-defined electrophoresis protocols |
| Additional Features | Auto-memory, auto-shutdown, timed run mode, intelligent mode prompts, optional power-resume and anti-diffusion field function |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600E |
| Instrument Type | Electrophoresis Power Supply |
| Output Modes | Constant Voltage / Constant Current / Constant Power (continuously adjustable) |
| Output Range | 10–600 V, 1–500 mA, 1–300 W |
| Resolution | 1 V / 1 mA / 1 W |
| Timer Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (increment: 1 V·h) |
| Display | Backlit LCD |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 280 × 237 × 118 mm |
| Net Weight | 3.2 kg |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600HC |
| Output Modes | Constant Voltage, Constant Current, Constant Power |
| Voltage Range | 10–600 V (1 V resolution) |
| Current Range | 1–1000 mA (1 mA resolution) |
| Power Range | 1–300 W (1 W resolution) |
| Timing Range | 1 min – 99 h 59 min |
| Display | Backlit LCD (128 × 64 pixels) |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 263 × 275 × 125 mm |
| Net Weight | 4.4 kg |
| Safety Protections | Overload, No-Load, Leakage Detection |
| Memory Capacity | 10 user-programmable methods |
| Optional Functions | Power-Fail Resume, Field Uniformity Enhancement (Anti-Diffusion Electrode Configuration) |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600HE |
| Output Modes | Constant Voltage / Constant Current / Constant Power |
| Voltage Range | 5–600 V (1 V resolution) |
| Current Range | 1–1000 mA (1 mA resolution) |
| Power Range | 1–300 W (1 W resolution) |
| Timing Range | 1 min – 99 h 59 min |
| Volt-Hour Range | 1–99999 V·h (1 V·h increment) |
| Display | Backlit LCD |
| Output Ports | 4 independent pairs |
| Dimensions (L×W×H) | 263 × 275 × 125 mm |
| Net Weight | 4.4 kg |
| Protection Features | Overload, Open-Circuit, Leakage Detection |
| Memory Capacity | 100 user-defined protocols |
| Stepwise Programming | Up to 10 sequential programs, each with up to 10 steps |
| Pause & Real-Time Adjustment | Supported without compromising output stability |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | JY600MCS-3 |
| Gel Tray Dimensions | 120 × 120 mm |
| Sample Capacity | 13 lanes (with 2.0 mm gel thickness) |
| Max Voltage Gradient | 9.5 V/cm (adjustable in 0.1 V/cm increments) |
| Max Current | 0.5 A |
| Max Power | 300 W |
| Pulse Angle | ±120° |
| Pulse Width | 1–9999 s (fixed) or 1–20 s (linear ramp) |
| Temperature Control Range | 10–30 °C (±0.5 °C stability) |
| buffer temperature sensing accuracy | ±0.1 °C |
| Buffer Volume | ~3000 mL |
| System Weight | 85.2 kg |
| Display | Backlit LCD (128 × 64 pixels) |
| Timing Range | 1 min – 99 h 59 min |
| Electrode Architecture | Hexagonal array with 18 independently addressable electrode segments |
| Cooling | Integrated recirculating chiller module |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | NZG-A |
| Gel Drying Area | 450 × 330 mm |
| Temperature Settings | 60 °C and 80 °C (dual fixed-point heating) |
| Timer Function | Yes |
| Dimensions (L×W×H) | 690 × 480 × 185 mm |
| Net Weight | 16.5 kg |
| Category | Gel Dryer for Electrophoresis Applications |
| Brand | Junyi |
|---|---|
| Origin | Beijing, China |
| Model | UV-II |
| Instrument Type | Portable (Handheld) |
| Wavelengths | 254 nm and 365 nm |
| Total Power | 8 W (4 W per lamp) |
| Reflective Illumination Area (W × L) | 200 × 50 mm |
| Dimensions (L × W × H) | 270 × 78 × 110 mm |
| Net Weight | 0.55 kg |
| Compliance | CE-marked for laboratory use (IEC 61010-1), RoHS compliant |
| Brand | JWINS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | JLGX-600B-LED |
| Illumination Method | Shelf-Mounted LED Array |
| Light Source | High-Efficiency SMD LED |
| Spectral Range | Visible Spectrum (400–700 nm) |
| Temperature Control Range | −15°C to +50°C |
| Temperature Fluctuation | ±0.5°C to ±1.0°C |
| Temperature Uniformity | ±0.5°C |
| Illuminance Range | 0–12,000 lx |
| Dimming Mode | Stepless Analog/Digital Control |
| Chamber Volume | 600 L |
| External Dimensions | 720 × 790 × 1920 mm |
| Brand | JWINS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | JMRC-450B-LED |
| Illumination Method | Shelf-Mounted LED Array |
| Light Source | High-Efficiency SMD LED Modules |
| Spectral Range | Visible Spectrum (400–700 nm PAR) |
| Temperature Control Range | 0–50 °C |
| Temperature Fluctuation | ±0.5–1.0 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 50–95% RH |
| Illuminance Range | 0–12,000 lux |
| Dimming Method | Continuous (0–100%) Analog/PWM Control |
| Chamber Volume | 450 L |
| External Dimensions | 720 × 670 × 1920 mm |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (PRC-manufactured) |
| Models | JY200C, JY300C, JY600C, JY1000C, JY1600C |
| Instrument Type | Protein Electrophoresis Power Supply |
| Gel Format Compatibility | Standard vertical mini-gels (e.g., 8 × 10 cm), horizontal gels, and blotting modules |
| Sample Capacity | Up to 10 samples per run |
| Output Range | 1–200 W (JY200C) to 1–300 W (JY600C/JY1000C) / 1–160 W (JY1600C) |
| Voltage Range | 5–200 V (JY200C) to 20–1600 V (JY1600C) |
| Current Range | 1–2000 mA (JY200C) to 1–1600 mA (JY1600C) |
| Resolution | 1 V / 1 mA / 1 W |
| Timer | 1 min – 99 h 59 min |
| Display | Backlit LCD (128 × 64 pixels) |
| Dimensions (L×W×H) | 28×24×11 cm (JY200C/JY300C), 27×26×12 cm (JY600C/JY1000C/JY1600C) |
| Weight | 3.2 kg (JY200C/JY300C), 6.8–7.7 kg (JY600C–JY1000C) |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Product Origin | Domestic (China) |
| Model | JY92-IIN |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 650 W |
| Operating Frequency | 22 kHz |
| Temperature Range | Ambient |
| Sample Volume | 0.5–600 mL |
| Sample Capacity | Single-sample processing |
| Duty Cycle | 0.1–99.9% |
| Input Voltage | 220 V / 110 V AC |
| Standard Probe | Φ6 mm titanium alloy horn |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | Kaluza |
| Product Type | Flow Cytometry Data Analysis Software |
| Intended Use | Research-Grade Flow Cytometry Data Processing |
| Minimum Display Resolution | 1440×900 |
| File Format Support | FCS 2.0/3.0/3.1, LMD |
| Operating System | Windows 7 (64-bit) and later |
| Brand | KeChenStarFly |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LumiFluor AVIS Faye A |
| Instrument Type | Optical In Vivo Imaging System |
| Price Range | USD 70,000 – 700,000 (approx.) |
| Imaging Modalities | Bioluminescence & Fluorescence |
| Brand | KECHENSTARFLY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Plant lumiScreen DIL |
| Price Range | USD 70,000 – 700,000 |