Life Science Instruments
Filter
Showing 5971–6000 of 7556 results
| Brand | Tanon |
|---|---|
| Model | VE-586 |
| Type | Semi-Dry Transfer Electrophoresis Cell |
| Origin | Shanghai, China |
| Compatible Power Supply | EPS-200 / EPS-300 / EPS-600 |
| Compatible Vertical Electrophoresis Units | VE-680 / VE-180 |
| Max Gel Capacity | 4 × standard mini-gels (e.g., 8.5 × 7.5 cm) |
| Electrode Design | Patented perforated electrode frame |
| Cooling | Passive heat dissipation via optimized electrode geometry and open-frame architecture |
| Accessories Supported | 586-1700 transfer filter paper, VE-10 single-well antibody incubation box, VE-110 multi-well antibody incubation box |
| Compliance | Designed for routine laboratory use in accordance with standard molecular biology workflows per ISO/IEC 17025-aligned practices |
| Brand | TATUNG |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | THI-150 / THI-250 |
| Heating Method | Air-jacketed |
| Cooling Method | Compressor-based |
| Humidification Water Reservoir | External |
| Temperature Range (with Humidification) | 4–60 °C |
| Temperature Range (without Humidification) | 0–60 °C |
| Temperature Fluctuation | ±1 °C |
| Temperature Uniformity | ±2.0 °C |
| Humidity Range | 55–90 %RH |
| Humidity Accuracy | ±5 %RH |
| Chamber Capacity | 250 L |
| External Dimensions (W×D×H) | 635 × 665 × 1765 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | TBI 0310 |
| Pricing | Available Upon Request |
| Impact Depth Range | 0–3.5 mm (adjustable in 0.01 mm increments) |
| Impact Velocity Range | 1.5–6.0 m/s (adjustable in 0.1 m/s increments) |
| Default Depth | 0.5 mm |
| Default Velocity | 3.5 m/s |
| Z-Axis Automated Travel Range | 102 mm |
| Manual X-Y Adjustment Range | 276 mm × 203 mm |
| Overall System Height | 736 mm |
| Actuation | Precision Pneumatic Cylinder (Bimba) |
| Brand | TCT (Xiamen Tongchuang) |
|---|---|
| Origin | Fujian, China |
| Instrument Type | Fully Automated |
| Detection Method | NDIR (CO₂, CH₄), NDUV (H₂S), Electrochemical or PMD Paramagnetic (O₂) |
| Measured Gases | CO₂, O₂, CH₄, H₂S |
| Accuracy | ≤ ±1.5% of reading or ±0.2% FS (CO₂/CH₄), ≤ ±1.5% of reading or ±1% FS (H₂S) |
| Zero Drift | CO₂ ≤ ±0.1%/8h |
| Span Drift | CO₂ ≤ ±0.1% FS/8h |
| Repeatability | CO₂ ≤ ±1% FS |
| Linearity | 0.99 ≤ slope ≤ 1.01 |
| Response Time (T90) | < 3 s (at inlet) |
| Sampling Frequency | 1 Hz |
| Gas Conditioning | Integrated electronic cooler (4–5°C), particulate filter, flow meter, condensate detection |
| Output | Standard Modbus RTU (RS-485), optional analog (0–5 V / 4–20 mA) |
| Channels | Configurable 1–12 multi-tank sequential sampling |
| Dimensions (W×H×D) | 450 mm × 370 mm × 310 mm |
| Weight | ~20 kg (EC-4 configuration) |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −25 to +65 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | 230 V AC |
| Warm-up Time | < 1 h (at 20 °C) |
| Ingress Protection | IP20 |
| Brand | TCT |
|---|---|
| Model | Ferment500 |
| Origin | Fujian, China |
| Instrument Type | Fully Automatic |
| Detection Method | Gas Sensing (Thermal Conductivity for CO₂ |
| Measured Parameters | CO₂, O₂, CER, OUR, RQ |
| Accuracy | ≤ ±1.5% FS |
| Sampling Frequency | ≥1 Hz |
| Dimensions | 355 mm × 195 mm × 436 mm |
| Channel Architecture | Four Independent Physical Channels with Dedicated Sensors |
| Environmental Compensation | Integrated Temperature, Humidity & Pressure Compensation |
| Gas Pre-treatment | Built-in Condensation-Based Moisture and Foam Removal System |
| Display | High-Resolution Touchscreen LCD |
| Calibration | Per-Channel Single-Point Calibration |
| Connectivity | Optional Ethernet/Wi-Fi with OTA Firmware Updates, Remote Diagnostics, Alarm Notification, Predictive Maintenance Logging |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | Fluent 480 Library Prep System |
| Sample Type | Purified Nucleic Acids |
| Throughput | 1–96 samples per run |
| Temperature Control Range (Deck Position) | 0–105 °C |
| Pipetting Range | 0.5–1000 µL |
| Deck Capacity | 30 positions (excluding expansion modules) |
| Kit Compatibility | Fully open platform — validated with >30 commercial NGS and third-generation library prep kits (Illumina, BGI, Element Biosciences, PacBio, Oxford Nanopore Technologies) |
| Cycle Time | Protocol- and input-volume dependent |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | DreamPrep NGS |
| Sample Type | Purified nucleic acid samples |
| Throughput | 1–96 samples per run |
| Temperature Control Range (Sample Deck) | 0–105 °C |
| Pipetting Range | 0.5–1000 µL |
| Deck Capacity | 48 positions (non-expandable) |
| Platform Compatibility | Fully open — validated with >30 commercial NGS library prep kits for Illumina, BGI, Element Biosciences, PacBio, and Oxford Nanopore platforms |
| Software Compliance | Supports audit trail, electronic signatures, and protocol versioning in accordance with FDA 21 CFR Part 11 and GLP/GMP requirements |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | Freedom EVO NAE Workstation |
| Category | Fully Automated Sample Preparation System |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Software Platform | FluentControl™ v5.x with audit trail (21 CFR Part 11 compliant configuration available) |
| Modularity | Configurable with Te-VacS Vacuum Module, Te-MagS Magnetic Separation Module, and robotic arm integration for plate handling |
| Kit Compatibility | Validated with Promega, Thermo Fisher Scientific (Life Technologies), MACHEREY-NAGEL, QIAGEN, and Roche nucleic acid isolation kits |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | Freedom EVO NGS |
| Sample Type | Purified Nucleic Acids |
| Throughput | 1–32 samples per run |
| Temperature Control Range for Sample Positions | 0–105 °C |
| Pipetting Range | 0.5–1000 µL |
| Deck Capacity | 20 or 28 positions (excluding optional expansion modules) |
| Open System Architecture | Compatible with third-party NGS library preparation kits from Illumina®, KAPA Biosystems, Thermo Fisher Scientific, and others |
| Software Interface | TouchTools™ (touchscreen-guided protocol execution) |
| Application Scope | NGS library construction, quantification, normalization, pooling, and integrated thermal cycling (with optional Covaris shearing and PCR instrument integration) |
| Brand | TECAN |
|---|---|
| Origin | Switzerland |
| Model | HydroFlex |
| Instrument Type | Multifunctional Microplate Washer |
| Wash Head Configuration | 8-channel or dual 8-channel (16-channel equivalent) |
| Wash Fluid Channels | 1, 2, or 4 selectable |
| Soaking Time | Programmable |
| Wash Cycles | 1–10 |
| Residual Volume per Well | ≤1.8 µL |
| Orbital Shaking | Linear, 3 adjustable speeds |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | HYDROFLEX™ |
| Instrument Type | Multifunctional Plate Washer |
| Application Scope | ELISA, Magnetic Bead-Based Assays, Vacuum Filtration, Adherent Cell Washing, Protein Microarray Processing |
| Control Options | Integrated Keypad & PC Software (HydroFlex Control Software) |
| Design Architecture | Modular |
| Liquid Handling Principle | Multi-point Aspiration, Drop-wise Dispensing |
| Vacuum System | Integrated Pressure-Sensing Vacuum Pump |
| Compliance Context | Designed to support GLP-compliant workflows |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | HYDROSPEED™ |
| Instrument Type | Multifunctional Plate Washer |
| Regulatory Compliance | EU IVD Directive 98/79/EC, FDA 21 CFR Part 11 (via HydroControl Software) |
| Key Features | Cell Protection™ Technology, Single-Well Dual-Magnet™ Bead Recovery, Anti-Clogging™ Needle Protection System |
| Design | Onboard Touchscreen Control, Integrated Sensors for Plate Detection & Automation Readiness |
| Plate Compatibility | 96-well and 384-well microplates |
| Application Flexibility | ELISA washing, gentle cell monolayer washing, magnetic bead-based assays, vacuum filtration (optional module) |
| Brand | Tecan |
|---|---|
| Origin | Shanghai, China |
| Model | Infinite E Plex (CN) |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Detection Technologies | Quad4™ Monochromator-Based Absorbance, Fluorescence, Luminescence (configurable per application) |
| Wavelength Range (Absorbance) | 230–1000 nm |
| Wavelength Accuracy | ±1.5 nm (260/280 nm verified) |
| Minimum Sample Volume (with NanoQuant Plate EP2045015) | 2 µL per well (16-well parallel measurement) |
| Optical Path | Quartz-fused silica microfluidic light path per sample position, factory-calibrated, no user recalibration required |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-ready software architecture |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Infinite F50 |
| Detection Method | Absorbance |
| Detection Technology | Photometric (LED-based) |
| Measurement Modes | Endpoint, Kinetic, Multi-Label (sequential absorbance reads) |
| Read Channels | 8-channel simultaneous detection |
| Automation Level | Semi-Automatic |
| Light Source | Long-life LED (no warm-up, no alignment required) |
| Software | Magellan v7.x with FDA 21 CFR Part 11 compliance modules |
| Regulatory Compliance | EU IVDR 2017/746 (formerly 98/79/EC IVD Directive), FDA 21 CFR Part 11 audit trail & electronic signature support |
| Vibration Control | Adjustable speed and duration |
| Optical Path Correction | Reference well normalization supported |
| Data Export | CSV, Excel, PDF, XML |
| Interface | USB 2.0, Ethernet |
| Plate Formats | 6–384-well microplates (standard footprint) |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | F50 |
| Function Type | Multimode |
| Automation Level | Semi-Automated |
| Detection Method | Absorbance (Photometric) |
| Wavelength Range | 400–750 nm |
| Absorbance Range | 0–4.00 OD |
| Linearity Range | 0.000–2.000 Abs |
| Optical Channels | 8-Channel Simultaneous Detection |
| Wavelength Accuracy | ±2 nm |
| Absorbance Resolution | 0.0001 OD |
| Read Speed | <10 sec per 96-well plate (single wavelength) |
| Light Source | High-Stability LED Array |
| Plate Formats | 6–384-well microplates, cuvettes (optional) |
| Compliance | ISO 13485:2016, FDA 21 CFR Part 11 (with Magellan Tracker), EU IVD Directive 98/79/EC, RoHS & WEEE |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Infinite® 200 PRO |
| Detection Modes | Up to 8 (Absorbance, Fluorescence Intensity, Time-Resolved Fluorescence, Fluorescence Polarization, Luminescence, AlphaScreen/AlphaLISA®, BRET, TR-FRET/HTRF) |
| Plate Formats | 6–384-well microplates, PCR plates, cuvettes |
| Wavelength Range | 230–1000 nm (monochromator-based) |
| Absorbance Linearity | < ±0.2% deviation |
| Z-axis Auto-Focusing | Yes |
| Gas Control Module (GCM) | Optional O₂/CO₂ regulation for live-cell assays |
| Detector Types | Photomultiplier tube (PMT) for fluorescence/luminescence |
| Software Compliance | Supports 21 CFR Part 11 audit trail, GLP/GMP data integrity features |
| Regulatory Alignment | Designed to support ISO/IEC 17025, CLSI EP12-A2, and USP <1033> validation protocols |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | MagicPrep NGS |
| Intended Use | Research Use Only (RUO) |
| Automation Level | Fully Integrated, Walk-Away Operation |
| Platform Compatibility | Illumina Sequencing Platforms |
| Throughput | Up to 96 samples per run |
| Setup Time | <10 minutes |
| Library Prep Workflow | Fragmentation, End Repair, A-Tailing, Adapter Ligation, PCR Amplification, Cleanup |
| Success Rate | >99% (based on internal validation studies under controlled lab conditions) |
| Regulatory Status | Not for clinical diagnostic use |
| Compliance | Designed in accordance with ISO 13485-aligned quality system principles for RUO instrumentation |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | T48 |
| Instrument Type | Fully Automated Western Blotting System |
| Automation Level | Fully Automated |
| Sample Capacity | Up to 48 samples per run |
| Incubation Temperature Control | Peltier-based active heating and cooling (range: 4–65 °C) |
| Wash Throughput | Simultaneous processing of up to 3 membrane strips |
| Reagent Delivery | Precision peristaltic pumps with auto-calibration |
| Waste Management | Dual-channel segregated waste collection (hazardous & biohazard) |
| Software | Blotware™ v5.x with audit trail, user access levels, and protocol scheduling |
| Compliance | Designed for GLP/GMP environments |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Spark Cyto |
| Automation Level | Fully Automated |
| Detection Modes | Fluorescence Imaging, Brightfield, Multimode Plate Reading (Absorbance, Fluorescence Intensity, Luminescence, Time-Resolved Fluorescence, FRET) |
| Imaging Capabilities | Widefield Epifluorescence, Full-Well Capture per Field, Z-Stacking, Kinetic Time-Lapse, 2D & 3D Cell Culture Compatibility |
| Objectives | 2×, 4×, 10× (Motorized, Auto-Focus Enabled) |
| Fluorescence Channels | 4 Independent Filter Sets (Configurable) |
| Software Platform | SparkControl™ MAGNA with Real-Time Experiment Control (REC), GLP-Compliant Audit Trail, FDA 21 CFR Part 11 Ready |
| Throughput Options | Standalone or Integrated with Tecan Fluent/Genesis Liquid Handling Platforms and Incubation Modules (e.g., Gas-Controlled Multi-Plate Incubator) |
| Brand | Tecan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Spark |
| Pricing | Available Upon Request |
| Brand | TECAN |
|---|---|
| Origin | Austria |
| Model | Spark |
| Function Type | Multimode |
| Automation Level | Fully Automated |
| Detection Modes | Absorbance (UV-Vis spectral scanning), Fluorescence Top/Bottom Read (including 3D fluorescence spectral scanning), Time-Resolved Fluorescence (TRF), TRF Spectral Scanning, Fluorescence Resonance Energy Transfer (FRET), Time-Resolved FRET (TR-FRET), Fluorescence Polarization (FP), Luminescence (Glow, Flash, Multicolor, High-Sensitivity Luminescence Spectral Scanning), AlphaScreen®/AlphaLISA®/AlphaPlex®, Real-Time Brightfield Cell Imaging (Cell Counting & Confluence Analysis) |
| Wavelength Range | 200–1000 nm |
| Additional Modules | Cuvette Port (Absorbance), NanoQuant Plate, Temperature Control (RT +3 °C to 42 °C), Integrated Liquid Handling with Heating & Stirring, CO₂ & O₂ Gas Control Module, Humidity Chamber (Volatile Compound Protection), Te-Cool™ Active Cooling (18–42 °C), Automatic Lid Lifting, Built-in QC Tools (IQ/OQ Support), Integrated Spark-Stack™ Microplate Stacker |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Model | Sunrise |
| Type | Absorbance Microplate Reader |
| Automation Level | Fully Automated |
| Measurement Methods | Single-/Multi-wavelength, Kinetic Assays |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0–3.0 OD (340–399 nm), 0–4.0 OD (400–750 nm) |
| Linearity | 0.000–2.0 OD |
| Detection Speed | Full-plate scan in 5 seconds (12-channel parallel detection) |
| Optical Resolution | 0.001 OD |
| Filter Options | 4-position, 6-position, or continuous monochromator (400–700 nm) |
| Compliance | FDA 21 CFR Part 11 (Magellan Tracker), EU IVD Directive 98/79/EC (Magellan Clinical) |
| Software Platform | Magellan™ (PC & embedded Windows CE versions) |
| Integration Capability | Compatible with Freedom EVO® and Freedom EVOlyzer® automated platforms |
| Brand | Tecan |
|---|---|
| Origin | Austria |
| Model | Sunrise |
| Detection Method | Absorbance |
| Function Type | Multifunctional |
| Automation Level | Fully Automated |
| Assay Modes | Endpoint, Kinetic, Scanning |
| Detector Type | Photodiode Array-Based Absorbance Detector |
| Regulatory Compliance | EU In Vitro Diagnostic Directive 98/79/EC |
| Software | Magellan™ v7.x (Multilingual: English, German, French, Italian, Spanish, Russian, Chinese) |
| Design | Modular Base System with Optional Upgrades (Variable Wavelength Selection, Precise Temperature Control, Barcode Reader, Plate Shaking) |
| Intended Use | Clinical Diagnostics, ELISA, Cytotoxicity Assays, Enzyme Kinetics, Quality Control in IVD Laboratories |
| Brand | Tecan |
|---|---|
| Origin | Switzerland |
| Platform | Freedom EVO-based modular system |
| Column Capacity | 96 RoboColumn® positions |
| Parallel Sample Processing | Up to 8 samples simultaneously |
| Compatible Columns | Atoll MediaScout® RoboColumns, GE Healthcare PreDictor™ RoboColumns |
| Application Scope | Expression screening, clone selection, media optimization, mAb purification condition scouting, resin evaluation, gradient method development, buffer exchange, desalting, concentration, and sample prep for crystallization or mass spectrometry |
| Brand | TECAN |
|---|---|
| Origin | USA |
| Model | Uno |
| Type | Fully Automated Benchtop System |
| Sample Volume | 20 µL |
| Throughput | 400 cells per run |
| Temperature Control | Ambient |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hybrigene HB-3D |
| Price | Upon Request |
| Brand | Techne |
|---|---|
| Origin | United Kingdom |
| Model | MSC |
| Speed Range | 0–80 rpm |
| Speed Accuracy | < ±3 rpm |
| Soft-Start/Stop Ramp Time | 20 sec acceleration/deceleration |
| Intermittent Mode | On-time 6 sec–5 min, Off-time 2 min–2 hr |
| Operating Environment | ≤40°C, ≤95% RH (non-condensing) |
| Power Supply | Dual-voltage 110/230 V, 50/60 Hz |
| Power Consumption | 2 W |
| Fuse Rating | 100 mA |
| Compatible Vessels | Pyrex® borosilicate glass flasks (125 mL–5 L), with 2 or 5 side necks |
| Stirrer Platforms | MCS-101L (1×3–5 L), MCS-102L (2×1 L), MCS-104S (4×500 mL), MCS-104L (4×1 L), MCS-104XL (4×5 L) |
| Material | Stainless steel base, siliconized stir rods, borosilicate glass vessels |
| Brand | Tekscan |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BPMS |
| Price Range | USD 14,000 – 70,000 |
| Brand | Tekscan |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Strideway |
| Pricing | Available Upon Request |
| Brand | Teleopto |
|---|---|
| Origin | Japan |
| Model | ELG-2 |
| Weight (Recorder) | 1.5 g |
| Battery Options | 1.2 g (mouse), 2.9 g (rat) |
| Recording Duration | 26 h (small battery), 70 h (large battery) |
| Channels | 2 differential inputs (EEG + EMG) |
| Sampling Rate | 100 Hz per channel |
| Input Range | ±5 mV |
| Resolution | 16-bit (0.2 µV step size at ±6.5 mV full scale) |
| High-Pass Filter | 0.1 Hz |
| Low-Pass Filter | 100 Hz |
| Data Storage | microSD card (binary format, MATLAB-compatible) |
| Electrode Interface | 5-pin, 1.27 mm pitch connector |
| Software | ELG-2 Viewer (FFT-based spectral analysis, sleep staging), EDF/TXT Converter (compliant with EDF+ standard) |