Life Science Instruments
Filter
Showing 1291–1320 of 7558 results
| Brand | TSE Systems |
|---|---|
| Origin | Germany |
| Model | Cell Culture Units |
| Application | In Vitro Air-Liquid Interface (ALI) Inhalation Toxicity Testing |
| Construction | Stainless Steel Exposure Chambers, Borosilicate Glass Mixing/Dilution Modules |
| Aerosol Compatibility | Liquid aerosols, dry powder aerosols, vapors, cigarette smoke |
| Flow Control | Mass flow controllers (MFCs) with real-time monitoring |
| Software | DACO Inhalation Control Software (customized version) |
| Capacity | Up to 48 Transwell® inserts per exposure unit |
| Temperature Control | Integrated heating system for long-term ALI culture maintenance |
| Aerosol Delivery | Dual independent exposure chambers with shared or separate aerosol generation |
| Uniformity | Internal flow distribution plate ensures homogeneous aerosol deposition across insert membranes |
| Compliance | Designed for GLP-compliant in vitro inhalation studies |
| Origin | France |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | Cellen One |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | cellenONE F1.1 |
| Product Type | Automated Single-Cell Dispensing System |
| Application Domain | Research |
| Laser Excitation Efficiency | 95% |
| Detection Channels | 3 |
| Optical Resolution (Spatial) | 200 nm |
| Fluorescence Sensitivity Threshold | ≥10,000 cells/s |
| Cell Processing Throughput | 0.2 cells/s (single-cell validation rate) |
| Core Technology | Piezoelectric Acoustic Droplet Ejection (ADE) with Real-Time Optical Monitoring |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | cellenONE |
| Product Category | Flow Cytometry-Based Single-Cell Dispenser |
| Application Domain | Research |
| Laser Efficiency | 95% |
| Detection Channels | 3 |
| Optical Resolution | 200 nm |
| Fluorescence Sensitivity | 10,000 cells/s |
| Cell Dispensing Throughput | 0.2 wells/s |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F1.4 |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | f1.4 |
| Detection Channels | 3 |
| Fluorescence Sensitivity | 10,000 cells/s |
| Cell Analysis Speed | 0.2 mL/min |
| Detection Resolution | 200 µm |
| Laser Efficiency | 95% |
| Product Type | Flow Cytometry-Based Single-Cell Isolation Platform |
| Compatible Collection Formats | 96-well, 384-well, 1536-well, and custom microplates |
| Reagent Dispensing Precision | Nanoliter (nL)-level |
| Single-Cell Isolation Accuracy | ≥95% |
| Minimum Input Volume | 5 µL |
| Minimum Viable Cell Input | 50 cells |
| Cell Viability Post-Isolation | >90% (vs. typical FACS: 70–85%) |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X1 |
| Pricing | Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X1 |
| Pricing | Available Upon Request |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | cellenONE X1 |
| Pricing | Available Upon Request |
| Brand | CYSEA |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Dimensions | 40 × 31 × 20 cm |
| Operating Temperature Range | 15–30°C (50–86°F) |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CleavagePro |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Synthesis Scale | 1–10 μmol |
| Reaction Vessel Count | 48 |
| Reaction Vessel Capacity Options | 15 mL / 50 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Discover Hydrolysis |
| Quotation | Upon Request |
| Reaction Method | Single-Mode Microwave |
| Reaction Time | 10 minutes |
| Sample Volume per Vial | 300 µL (up to 10 vials) |
| Temperature Control Range | 0–300 °C |
| Hydrolysis Scale | 1 pmol – 1 fmol |
| Vial Format | HPLC-compatible glass autosampler vials (100–300 µL) |
| Temperature Sensor | In-situ fiber-optic probe (RT–300 °C) |
| Vacuum Level | 25 mmHg |
| Stirring Mechanism | Magnetic stirring |
| Atmosphere Control | Alternating vacuum/N₂ purging via integrated valve panel |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | DISCOVER SPS |
| Reaction Mode | Single-Mode Microwave |
| Max. Reaction Volume | 300 mL |
| Sample Throughput | 14 samples per run |
| Temperature Range | 0–300 °C |
| Typical Enzymolysis Temperature | 55 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Sensing | In-situ Fiber-Optic Probe |
| Mixing | Magnetic Stirring |
| Cooling | 5 PSI Forced Air |
| Sample Vial Format | 1.5 mL Microcentrifuge Tubes |
| Minimum Sample Volume | 30 µL |
| Hydrolysis Time (Typical) | 10–15 min |
| Enzyme-to-Protein Ratio Range | 1:100 to 1:10 |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | Liberty Lite 2.0 |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Synthesis Scale | 0.005–5 mmol |
| Reactor Count | 4 |
| Reactor Volume Range | 10–125 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Liberty Prime 2.0 |
| Quotation | Upon Request |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 0.0005–5 mmol |
| Number of Reactors | 3 |
| Reactor Volume Range | 10–125 mL |
| Syringe Pump Accuracy | ±0.01 mL |
| Crude Peptide Purity | >70% |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Liberty PRO |
| Pricing | Upon Request |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| Synthesis Scale | 15–1000 mmol |
| Reactor Count | 3 |
| Reactor Volume Options | 3 L, 8 L, 15 L (max. 15 L capacity) |
| Crude Peptide Yield per Batch | Up to 1 kg |
| Synthesis Purity | ≥99% |
| Temperature Control | NIST-Traceable Internal Sensor |
| Stirring Modes | Mechanical Agitation + N₂ Sparging |
| Regulatory Compliance | cGMP-Compliant Materials & Architecture |
| Key Patented Technologies | CarboMAX™ Coupling, HE-SPPS (High-Efficiency Solid-Phase Peptide Synthesis), No-Wash Deprotection/Coupling |
| Core Patents | US7393920 |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures, Role-Based Access Control |
| Validation Documentation | FAT, IQ/OQ, FDS/SDS, Leachables & Extractables Reports, ATEX Hazard Analysis |
| Brand | CEM |
|---|---|
| Origin | USA |
| Model | LibertyBlue 2.0 |
| Amino Acid Delivery | Automated |
| Reagent Delivery | Automated |
| User Authentication | Password + Facial Recognition |
| Audit Trail | Yes |
| Synthesis Scale | 0.005–5 mmol |
| Reactor Count | 4 |
| Reactor Volume Range | 10–125 mL |
| Brand | CEM |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | RAZOR |
| Amino Acid Addition | Automated |
| Reagent Addition | Automated |
| Operator Authentication | Password + Facial Recognition |
| Audit Trail | Yes |
| Brand | Loligo Systems |
|---|---|
| Origin | France |
| Model | CentriTower |
| Optical System | Telecentric lens assembly |
| Camera | 5.1 MP industrial sensor (2472 × 2064) |
| Frame Rate | 75 fps |
| Field of View | 137 mm × 102 mm |
| IR Backlight | 850 nm, 160 mm × 160 mm uniform illumination |
| Tower Dimensions | 380 mm × 370 mm × 575 mm (W × D × H) |
| Software | LoligoTrack behavioral analytics suite with ROI-based multi-animal tracking, kinematic point annotation, and batch processing |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cereplex Direct |
| Price Range | USD 14,000 – 70,000 |
| Brand | Cerillo |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Alto (Stratus Upgrade Edition) |
| Detection Method | Absorbance |
| Detection Mode | Optical Density (OD) |
| Measurable Range | 0.000–4.000 OD |
| Temperature Range | 0–50 °C |
| Wavelengths | 600 nm, 450 nm, and customizable monochromatic LED sources |
| Resolution | 0.001 OD |
| Accuracy | < ±1% or ±0.02 OD (0–2.500 OD, endpoint mode) |
| Repeatability | < ±0.25% or ±0.005 OD (0–2.500 OD, endpoint mode) |
| Plate Compatibility | 6-, 12-, and 96-well standard microplates |
| Dimensions (Analyzer) | 15.0 × 13.3 × 7.2 cm |
| Weight (Analyzer) | 800 g |
| Power Input | 5 V, 500 mA via USB-C |
| Operating Environment | 0–50 °C, 0–99% RH |
| Software OS Support | macOS 11/12, Windows 10/11 |
| Data Storage | 16 GB internal (expandable to 32 GB), CSV export |
| Wireless Capability | Optional Bluetooth/Wi-Fi module, up to 5 units daisy-chained, max range 15 m |
| Compliance | RoHS, REACH, FCC, CE |
| Intended Use | Research Use Only (RUO), not for diagnostic or clinical applications |
| Brand | Other brands |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | General distributor |
| Product Origin | Domestic (China) |
| Model | Cerillo |
| Price | Upon request |
| Measurement Mode | Endpoint and kinetic absorbance |
| Plate Compatibility | 6-, 12-, and 96-well plates |
| Dimensions | 15.0 × 13.3 × 7.2 cm (W × D × H) |
| Weight | 800 g |
| Power Supply | 5 V, 500 mA via USB-C |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–99% RH |
| Wavelengths | 450 nm and 600 nm (monochromatic LEDs) |
| Optical Density (OD) Resolution | 0.001 OD |
| OD Range | 0.000–4.000 OD |
| Linearity | < ±1% (0.000–2.500 OD) |
| Accuracy (Endpoint) | < ±1% and ±0.02 OD (0.000–2.500 OD) |
| Accuracy (Kinetic) | < ±0.25% and ±0.005 OD (0.000–2.500 OD) |
| Repeatability | < ±0.25% and ±0.005 OD (0.000–2.500 OD) |
| Membrane Material | Polycarbonate |
| Surface Treatment | PVP (polyvinylpyrrolidone) hydrophilic coating |
| Pore Size | 0.2 µm |
| Effective Membrane Area | 0.503 cm² |
| Membrane Diameter | 0.8 cm |
| Membrane Thickness | 25 µm |
| Data Storage | microSD card (up to 32 GB |
| OS Compatibility | macOS 11 (Big Sur) or later |
| Data Export Formats | .csv (on-device), .xlsx (via Labrador software) |
| Regulatory Compliance | RoHS, REACH, FCC, CE |
| Brand | CETONI |
|---|---|
| Origin | Germany |
| Model | Qmix TC-Heated Syringe & Heating Sleeve |
| Max. Heating Temperature | 200 °C |
| Heating Power | Syringe: 150 W, Sleeve: 70 W |
| Supply Voltage | 24 V DC |
| Construction Material | Stainless Steel (Syringe), Custom Polymer/Alloy Composite (Sleeve) |
| Compatible With | CETONI Qmix modular fluid control platform |
| Compliance | CE-marked, RoHS-compliant, Designed for Lab-Scale Process Integration |
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | CFX96 Deep Well Dx |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well format |
| Heating Rate | 2.5 °C/sec |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C |
| Excitation Channels | 5 + 1 (including reference channel) |
| Detection Method | Scanning-based fluorescence acquisition |
| Max Reaction Volume | 125 µL |
| LED Light Source Lifetime | >50,000 hours |
| Compliance | MIQE-guided software, FDA 21 CFR Part 11–ready audit trail, ISO 13485-aligned IVD design |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-0607 |
| Pricing | Upon Request |
| Operating Mode | Dual-channel |
| Filtration Method | Adjustable Vacuum Pump Suction |
| Filter Membrane | Glass Fiber, 0.65 µm Pore Size |
| Solvent | Trichloroethylene (TCE) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Power Consumption | ≤100 W |
| Ambient Operating Temperature | 15–35 °C |
| Relative Humidity | ≤85% |
| Dimensions (L×W×H) | 420 × 320 × 360 mm |
| Net Weight | 8.8 kg |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-0701 |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Aging Bath Temp Range | Room Temp to 120 °C |
| Aging Bath Temp Accuracy | ±0.5 °C |
| Filtration Bath Temp | 10 °C ±1 °C |
| Steam Pressure Output | 0–0.4 MPa |
| Vacuum Pump Ultimate Pressure | 200 mbar |
| Magnetic Stirrer Speed Range | 0–2400 rpm |
| Magnetic Stirrer Temp Range | Room Temp to 99.9 °C |
| Dimensions (L×W×H) | 570 × 320 × 560 mm |
| Net Weight | 15 kg |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-30011 |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Temperature Range | 0–520 °C |
| Temperature Control Accuracy | ±5 °C |
| Sample Capacity | 4 positions |
| Dimensions (L×W×H) | 600 mm × 260 mm × 550 mm |
| Net Weight | 21 kg |
| Compliance | SH/T 0170 |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-4508C |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Measurement Range | 1500 mm (±10 mm) |
| Temperature Control Range | 5 °C to 50 °C (adjustable), resolution 0.01 °C |
| Temperature Stability | ±0.1 °C |
| Pulling Speeds | 1 cm/min and 5 cm/min (dual fixed rates) |
| Measurement Accuracy | ±1 mm |
| Heating Power | 4500 W |
| Refrigeration | Compressor-based cooling |
| Bath Uniformity | Achieved via shielded hot-cold balanced pressurized circulation system |
| Data Processing | 32-bit ARM microcontroller with automatic ductility calculation and real-time display |
| Storage | Internal data logging with touchscreen-triggered record capture |
| Dimensions (L×W×H) | 2370 × 520 × 1000 mm |
| Net Weight | 285 kg |
| Max. Power Consumption | ≤5600 W |
| Operating Environment | 15–35 °C, RH ≤85% |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SYD-5096A |
| Price | Upon Request |
| Power Supply | AC (220 ± 10%) V, 50 Hz |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±1 °C |
| Sample Capacity | 4–12 copper strips (4 test bomb positions, each accommodating 1 bomb or up to 3 glass tubes) |
| Display | LCD temperature controller with integrated timer and audible alarm |
| Reference Standard | GB/T 5096 |
| Calibration Reference | NIST-traceable ASTM D130-compliant copper strip color chart (imported from USA) |
| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-6538 |
| Temperature Control Range | −50 °C to 100 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Stability | ±0.05 °C |
| Viscosity Measurement Range | 1200–27000 mPa·s |
| Shear Rate Range | 10⁴–10⁵ s⁻¹ |
| Refrigeration Capability | −50 °C to ambient |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Total Power Consumption | 2 kW |
| Dimensions (Main Unit) | 420 × 300 × 620 mm (L×W×H) |
| Dimensions (Cold Bath) | 500 × 530 × 615 mm (L×W×H) |
| Compliance | GB/T 6538, ASTM D5293 |