Life Science Instruments
Filter
Showing 1231–1260 of 7558 results
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001 |
| Category | Imported |
| Distributor Type | Authorized Distributor |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | ECM2001 |
| Price Range | USD 14,000 – 43,000 |
| Product Category | Cell Analysis System |
| AC Parameters | Non-sinusoidal waveform, 1 MHz frequency, 0–75 V amplitude, 0–99 s duration, AC/DC inter-pulse interval 50 µs |
| DC Parameters (High-Voltage Mode) | 10–3000 V (10 V step), pulse width 1–99 µs (1 µs step) |
| DC Parameters (Low-Voltage Mode) | 10–500 V (10 V step), pulse width 1–99 ms (1 ms step) or 10–990 µs (10 µs step) |
| Pulse Count | 1–9 pulses per train |
| Inter-Pulse Interval | 1 s |
| Cycle Count | 0–9 cycles |
| Minimum Load Impedance | 20 Ω |
| Electrode Compatibility | All BTX electrodes except 35 mm dish electrodes |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001 |
| Type | Dual-Mode Electroporator/Electrofusion Instrument |
| Compliance | Designed for GLP-compliant cell manipulation workflows |
| Software Interface | Analog control with manual pulse parameter adjustment |
| Pulse Modes | AC pre-alignment, DC square-wave fusion, AC post-aggregation |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM 2001 |
| AC Waveform | Non-sinusoidal, 1 MHz |
| AC Voltage Range | 0–75 V |
| AC Pulse Duration | 0–99 s |
| Post-fusion AC Voltage | 10% of pre-fusion voltage |
| Post-fusion AC Duration | 1–9 s |
| AC/DC Interval | 50 µs |
| DC Mode — High-Voltage | 10–3000 V (10 V increments), Pulse Width: 1–99 µs (1 µs resolution) |
| DC Mode — Low-Voltage | 10–500 V (10 V increments), Pulse Width Options: 1–99 ms (1 ms resolution) or 10–990 µs (10 µs resolution) |
| Number of Pulses | 1–9 |
| Inter-pulse Interval | 1 s |
| Cycle Count | 0–9 |
| Minimum Load Impedance | 20 Ω |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001+ |
| Pulse Types | AC sine wave and DC square wave |
| High Voltage Range | 505–3000 V |
| Low Voltage Range | 5–500 V |
| Pulse Duration (DC) | 10 µs–999 ms |
| AC Frequency | 0.2–2.0 MHz |
| AC Voltage | 5–75 V |
| AC Pulse Time | 0–99 s |
| Capacitance | 2200 µF |
| Internal Resistance | 8 Ω |
| Max Discharge Cycles | 0–100 |
| Discharge Time | 7 s |
| Display | 7-inch color touchscreen |
| Preloaded Protocols | Cell fusion, somatic cell nuclear transfer (SCNT), hybridoma generation, electroporation for primary/stem cells |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM2001+ |
| High-Voltage Range | 505–3000 V |
| Low-Voltage Range | 5–500 V |
| Pulse Duration | 10 µs–999 ms |
| Resistance Setting | 1 Ω |
| Compliance | CE, FDA-listed device for research use only |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM399 |
| Type | Square-Wave & Exponential Decay Electroporator |
| Application Scope | Mammalian, Bacterial, Yeast, Plant & Primary Cell Transfection and Electrofusion |
| Brand | BTX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ECM 399 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ECM399 |
| Pricing | Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM630 |
| Voltage Range | 10–500 V (low-voltage mode), 50–2500 V (high-voltage mode) |
| Capacitance | 1 µF, 25–3275 µF (25 µF increments in low-voltage mode) |
| Resistance | 25–1575 Ω (25 Ω increments, high-voltage mode only) |
| Pulse Type | Exponential decay |
| Max. Current Limit | 6000 A (LV), 3000 A (HV) |
| Charge Time | ≤5 s |
| Safety | Short-circuit protection with 10 s max delay |
| Display | 20×4-character LCD |
| Dimensions | 31.8 × 31.1 × 14.0 cm (W×D×H) |
| Weight | 4.5 kg |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM 630 |
| High-Voltage Range | 505–3000 V |
| Low-Voltage Range | 5–500 V |
| Capacitance Range | 25–3275 µF |
| Resistance Range | 25–1575 Ω |
| Pulse Form | Exponential Decay |
| Pulse Duration | 133 ms–5 s |
| Voltage Resolution (LV) | 1 V |
| Voltage Resolution (HV) | 5 V |
| Capacitance Resolution (LV) | 25 µF |
| Resistance Resolution | 25 Ω |
| Max Time Constant | 5 s @ 500 V or 133 ms @ 3000 V |
| Programmable Protocols | >1,000 stored |
| Display | 7-inch color touchscreen |
| Charging Time (LV) | <7 s |
| Charging Time (HV) | <4 s |
| Arc Suppression | Yes |
| Short-Circuit Protection | Yes |
| Pre-Pulse Resistance Measurement | Yes |
| Current-Limiting Pulse Termination | Yes |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM630 |
| Pricing | Upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | ECM830 |
| High-Voltage Mode | 50–3000 V (5 V step), 56 Ω, 111 µF, pulse width 10–600 µs (1 µs resolution) |
| Low-Voltage Mode | 5–500 V (1 V step), 56 Ω, 4000 µF, pulse width 10–999 µs / 1–999 ms / 1–10 s (1 µs / 1 ms / 0.1 s resolution) |
| Pulse Number | 1–99 |
| Inter-Pulse Interval | 100 ms–10 s |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM 830 |
| High-Voltage Range | 505–3000 V |
| Low-Voltage Range | 5–500 V |
| Pulse Form | Square Wave |
| Capacitance | 3,775 µF (LV), 85 µF (HV) |
| Number of Pulses | 1–99 (or up to 120 in high-throughput mode) |
| Pulse Duration | 10 µs–10 s (LV: 10 µs–999 ms |
| HV | 10–600 µs) |
| Discharge Time | LV <7 s, HV <4 s |
| Resistance Check | Yes |
| Arc Suppression | Yes |
| Short-Circuit Protection | Yes |
| Display | 7-inch color touchscreen |
| Programmable Protocols | >1,000 stored methods |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Models | BTX 610, BTX 620, BTX 640 |
| Sterility | Gamma-Irradiated, Individually Packed |
| Electrode Material | Embedded Aluminum |
| Electrode Gap Options | 1.0 mm, 2.0 mm, 4.0 mm |
| Maximum Electric Field Strength | 25 kV/cm |
| Cap Design | Leak-Resistant Snap-On Cap |
| Volume Range per Cuvette | 20–800 µL |
| Packaging | 50 sterile units per box |
| Brand | BTX |
|---|---|
| Origin | United Kingdom |
| Model | F700 |
| Anesthetic Vaporizer | Imported precision vaporizer for isoflurane and sevoflurane |
| Animal Compatibility | Mice, rats, guinea pigs, and small rabbits |
| Oxygen Flush Rate | Up to 10 L/min |
| Anesthetic Concentration Range | 0–5% (adjustable in 0.1% increments) |
| Flowmeter Range | 1–4 L/min (configurable single/dual/penta-channel) |
| Circuit Type | Semi-closed and open systems |
| Exhaust Management | Active and passive scavenging options |
| Form Factor | Benchtop and mobile configurations |
| Standard Accessories | Anesthesia main unit, induction chamber, anesthesia tubing, CO₂ absorbent canister |
| Optional Accessories | Multi-channel flowmeters, rodent-specific masks (mouse/rat), large/small scavenging canisters, maintenance platform |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Gemini SC |
| Price Range | USD 68,000 – 109,000 |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | Gemini SC |
| High-Voltage Range | 510–3000 V |
| Low-Voltage Range | 10–500 V |
| Capacitance Range | 25–3275 µF |
| Pulse Form | Square Wave and Exponential Decay Wave |
| Pulse Duration | 50 µs – 100 ms |
| Number of Pulses | 1–99 |
| Discharge Time (LV) | <7 s |
| Discharge Time (HV) | <4 s |
| Resistance Range | 50–1000 Ω |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 505–3000 V (5 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1 ms–5.158 s |
| Pulse Duration (Exponential, HV) | 0.5 ms–133.875 ms |
| Pulse Count (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Count (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Inter-Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF |
| Capacitance (HV) | 85 µF |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 35, 50, 60, 75, 85 µF |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV), 50–1575 Ω (25 Ω step, HV) |
| Electrode Compatibility | BTX standard cuvettes, in vivo electrodes, MOS 96-well electroporation plates, footswitch |
| Software Control | USB and Ethernet interface for protocol download, storage, and remote execution |
| Safety Features | Arc suppression, short-circuit protection, real-time impedance monitoring |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| High-Voltage Range | ±3000 V |
| Low-Voltage Range | 5 V |
| Pulse Duration | 10 µs – 999 ms |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | Gemini X2 |
| High Voltage Range | 505–3000 V |
| Low Voltage Range | 5–500 V |
| Capacitance Range | 10–3275 µF |
| Resistance Range | 25–1575 Ω |
| Pulse Forms | Square Wave & Exponential Decay Wave |
| Pulse Duration | 10 µs–999 ms (LV), 10 µs–600 µs (HV) |
| Pulse Count | 1–99 per sample (up to 10 in high-throughput mode) |
| Discharge Time | <7 s (LV), <4 s (HV) |
| Pre-pulse Resistance Measurement | Yes |
| Built-in Protocol Library | Yes |
| Interface | 7-inch Touchscreen + PC Connectivity (USB) |
| Dimensions | 31.25 × 27.5 × 20 cm |
| Weight | 6.75 kg |
| Input Voltage | 100–250 V AC |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MOS High-Throughput Multiwell Electroporation System |
| Quotation | Available Upon Request |
| Pulse Generator Compatibility | ECM630 & ECM830 |
| MOS Plate Formats | 25-well & 96-well |
| MOS Plate Processor Models | HT-100 (manual column-by-column pulsing) & HT-200 (automated sequential column pulsing) |
| Voltage Range | 0–3000 V DC |
| Pulse Duration | 10 µs – 10 s |
| Number of Pulses | 1–99 |
| Electrode Architecture | Patented composite electrode array with cross-contamination mitigation design |
| Included Accessories | Sterile plate lid for contamination control |
| Brand | BTX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX High Throughput |
| Pricing | Upon Request |
| Pulse Generator Compatibility | ECM630, ECM830, Gemini X2 |
| Electrode Plate Types | 25-well and 96-well HT Microelectrode Plates |
| Pulse Voltage Range | 0–3000 V DC |
| Pulse Duration | 10 µs – 10 s |
| Number of Pulses | 1–99 |
| Electrode Plate Processor Models | HT-100 (manual column-by-column pulsing), HT-200 (automated sequential column pulsing) |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Hybrimune |
| Capacity Options | 2 mL (microscope-compatible transparent chamber) & 9 mL fusion chambers |
| AC Pre-Fusion Pulse | 0.2–2.0 MHz (0.2 MHz step), 5–75 V (0.1 V step), 0–60 s (1 s step), non-sinusoidal ramp-up waveform |
| AC Post-Fusion Pulse | same frequency/voltage range, ramp-down waveform |
| DC Fusion Pulse | square wave, 100–1000 V (5 V step), 20–1000 µs (10 µs step), 0–10 pulses, 0.125–10 s inter-pulse interval |
| Cycles | 1–10 sets |
| Operating Temperature | 20–30 °C |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hybrimune Large-Scale Fusion System |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BTX Hybrimune Large-Volume Electrofusion System |
| Pricing | Available Upon Request |
| AC Parameters | Sine-wave frequency (0.2–2.0 MHz, 0.2 MHz step), Voltage range (5–75 V, 5 V step), Amplitude factor (k = 0.1–20, unitless, 1-step increment), Pulse duration (0–60 s, 1 s step) |
| DC Parameters | Square-wave voltage (100–1000 V, 5 V step), Pulse width (20–1000 µs, 10 µs step), Number of pulses (0–10), Inter-pulse interval (0.125–10 s, 0.001 s step) |
| Fusion Chamber Dimensions | Volume capacity (2 mL and 9 mL configurations), Chamber height (5 mm and 18 mm), Outer diameter (45.72 mm), Inner diameter (38.10 mm), Electrode gap (3.81 mm) |
| Sterilization | Compatible with NaOH, ethanol, and Spor-Klenz for repeated use |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | BTX MAX Transfection System |
| Pricing | Available Upon Request |
| Electroporation Chamber Gap | 4 mm |
| Sample Volume Range | 2–6 mL |
| Voltage Range | 50–1200 V |
| Pulse Duration | 0.05–10 ms |
| Inter-Pulse Interval | 0.2–1000 ms (1 Hz–5 kHz) |
| Data Interface | USB Flash Drive Support |
| Control Interface | Capacitive Touchscreen |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 454 |
| Pricing | Available Upon Request |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Model 524 |
| Electrode Type | Reusable tweezer-style in vivo electroporation electrode |
| Electrode Disk Diameter Options | 7 mm (Model 520) or 10 mm (Model 523) |
| Adjustable Inter-Electrode Gap | <1 mm to >20 mm |
| Compatible Pulse Generators | BTX ECM 830, ECM 630, ECM T820, ECM 2001 |
| Electrode Material | Stainless steel |
| Sterilization Method | Ethanol or ethylene oxide |
| Connection | BTX Model 524 Cable |
| Compliance | Designed for GLP-compliant preclinical research workflows |